945 Professional Detector Vario – Conductivity & Amperometry
2.945.0030
-
- PEEK capillary 0.25 mm i.d. / 3 m
- 6.1831.010
- For all IC components.
- For all IC components.
- PCS
- 1
- PEEK capillary 0.75 mm i.d. / 3 m
- 6.1831.030
- For all IC components.
- For all IC components.
- PCS
- 1
- Cable USB A - USB B 1.8 m
- 6.2151.020
- USB connecting cable
- USB connecting cable
- PCS
- 1
- Connecting cable to 61257XXX
- 6.2165.000
- Connecting cable for amperometric detector cell.
- Connecting cable for amperometric detector cell.
- PCS
- 1
- Pressure screw 5x
- 6.2744.010
- With UNF 10/32 connection. For the connection of PEEK capillaries
- With UNF 10/32 connection. For the connection of PEEK capillaries
- PCS
- 1
- Dummy cell to the IC Amperometric Detector.
- 6.2813.040
- Dummy cell for performance tests.
- Dummy cell for performance tests.
- PCS
- 1
-
- 945 Professional Detector Vario – Conductivity & Amperometry
- 1.945.0030
- 高性能電気伝導度検出器IC導電率検出器および4つの測定モードDC、PAD、flexIPAD、CVを備えたICアンペロメトリック検出器が装備された、インテリジェントスタンドアローン検出器。インテリジェントIC装置と、または電気伝導度検出器およびアンペロメトリック検出器のための独立した検出器として使用できます。
- <p>高性能電気伝導度検出器IC導電率検出器および4つの測定モードDC、PAD、flexIPAD、CVを備えたICアンペロメトリック検出器が装備された、インテリジェントスタンドアローン検出器。インテリジェントIC装置と、または電気伝導度検出器およびアンペロメトリック検出器のための独立した検出器として使用できます。</p>
- PCS
- 1
- PEEK capillary 0.25 mm i.d. / 3 m
- 6.1831.010
- For all IC components.
- For all IC components.
- PCS
- 1
- PEEK capillary 0.75 mm i.d. / 3 m
- 6.1831.030
- For all IC components.
- For all IC components.
- PCS
- 1
- Cable USB A - USB B 1.8 m
- 6.2151.020
- USB connecting cable
- USB connecting cable
- PCS
- 1
- Connecting cable to 61257XXX
- 6.2165.000
- Connecting cable for amperometric detector cell.
- Connecting cable for amperometric detector cell.
- PCS
- 1
- Pressure screw 5x
- 6.2744.010
- With UNF 10/32 connection. For the connection of PEEK capillaries
- With UNF 10/32 connection. For the connection of PEEK capillaries
- PCS
- 1
- Dummy cell to the IC Amperometric Detector.
- 6.2813.040
- Dummy cell for performance tests.
- Dummy cell for performance tests.
- PCS
- 1
-
- Wall-Jet Cell
- 6.1257.010
- Amperometric detector cell with Wall-Jet geometry.
- <p>Amperometric detector cell with Wall-Jet geometry.</p>
- PCS
- 1
- Thin-Layer cell
- 6.1257.100
- Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).
- <p>Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).</p>
- PCS
- 1
- Au working electrode, 3 mm
- 6.1257.210
- Working electrode made of gold for amperometric detection, 3 mm diameter.
- Working electrode made of gold for amperometric detection, 3 mm diameter.
- PCS
- 1
- GC working electrode
- 6.1257.220
- Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.
- <p>Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.</p>
- PCS
- 1
- Pt working electrode
- 6.1257.230
- Platinum working electrode for amperometric detection, 3 mm diameter.
- Platinum working electrode for amperometric detection, 3 mm diameter.
- PCS
- 1
- Ag working electrode
- 6.1257.240
- Silver working electrode for amperometric detection, 3 mm diameter.
- Silver working electrode for amperometric detection, 3 mm diameter.
- PCS
- 1
- Au working electrode, 2 mm
- 6.1257.260
- Working electrode made of gold for amperometric detection, 2 mm diameter.
- Working electrode made of gold for amperometric detection, 2 mm diameter.
- PCS
- 1
- Cu working electrode, 2 mm
- 6.1257.270
- Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.
- <p>Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.</p>
- PCS
- 1
- Ag/AgCl reference electrode for 6.1257.xxx
- 6.1257.720
- Silver/silver chloride reference electrode for amperometric detection.
- <p>Silver/silver chloride reference electrode for amperometric detection.</p>
- PCS
- 1
- Pd reference electrode to 6.1257.xxx
- 6.1257.740
- Palladium reference electrode for amperometric detection.
- <p>Palladium reference electrode for amperometric detection.</p>
- PCS
- 1
- 50 µm spacer for the Wall-Jet cell.
- 6.1257.810
- 50 µm spacer for the amperometric Wall-Jet cell, 3 pcs.
- <p>50 µm spacer for the amperometric Wall-Jet cell, 3 pcs.</p>
- PCS
- 1
- 50 µm spacer to Thin-Layer cell
- 6.1257.820
- 50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.
- <p>50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.</p>
- PCS
- 1
- 25 µm spacer for the Wall-Jet cell
- 6.1257.830
- 25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.
- <p>25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.</p>
- PCS
- 1
- 25 µm spacer to Thin-Layer cell
- 6.1257.840
- 25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.
- <p>25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.</p>
- PCS
- 1
- 付属品キット: IC Amperometric Detector
- 6.5000.200
- 伝導性の低い溶液での測定のための IC Amperometric Detector のオプションとしての付属品セット。
- <p>伝導性の低い溶液での測定のための IC Amperometric Detector のオプションとしての付属品セット。</p>
- PCS
- 1
- IC equipment Wall-Jet cell: without electrodes
- 6.5337.000
- Equipment comprised of Wall-Jet cell with additional accessories, without electrode.
- <p>Equipment comprised of Wall-Jet cell with additional accessories, without electrode.</p>
- PCS
- 1
- IC equipment Wall-Jet cell: Carb (Au, Pd)
- 6.5337.010
- Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.
- <p>Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.</p>
- PCS
- 1
- IC equipment Wall-Jet cell: Cyanide (Ag, Pd)
- 6.5337.020
- Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.
- <p>Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.</p>
- PCS
- 1
- IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).
- 6.5337.030
- Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.
- <p>Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.</p>
- PCS
- 1
- IC equipment Thin-Layer cell: without electrodes
- 6.5337.200
- Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.
- <p>Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.</p>
- PCS
- 1
- IC機器: 薄層セル: Carb (Au、Pd)
- 6.5337.210
- 追加の付属品を含む薄層セルから構成される機器、金作用電極ならびにパラジウム参照電極による炭水化物分析のための電極付き。
- <p>追加の付属品を含む薄層セルから構成される機器、金作用電極ならびにパラジウム参照電極による炭水化物分析のための電極付き。</p>
- PCS
- 1