- AN-T-204Permanganate index in water
The permanganate index (PMI) is a sum parameter that indicates the total load of oxidizable organic and inorganic matter in water. The substances concerned are mainly humic materials/acids that are primarily formed when dead organic material present in soil is further broken down and released into water sources. As it is an indicator of the water quality, testing of the PMI for drinking water is obligatory in many countries.For the determination, it is necessary to heat the stabilized water sample to 95 °C and higher for a stipulated time. Afterwards, the amount of permanganate that has remained after the reaction with the sample is determined titrimetrically. This sample preparation step requires considerable manual effort.In this Application Note, a fully automated procedure for the determination of the PMI according to GB/T 11892 is described, including all sample preparation steps. The gains in productivity because of a reduced manual workload are considerable.
- AN-T-205OMNISによる完全自動の水質分析
電気伝導度、pH値、アルカリ度、カルシウム硬度、マグネシウム硬度、ならびに総硬度などといった物理的および化学的パラメータの測定は、水道水の水質検査において必要不可欠です。このような必須の複数の水質検査項目をOMNIS滴定システムなら1つのシステム内で並行して自動測定できます。
- AN-T-206Bromine index of petroleum-based hydrocarbons
The bromine index is an important parameter for the determination of aliphatic C=C double bonds in petroleum hydrocarbons. For the titration, a solvent mixture of glacial acetic acid, methanol, and dichloromethane is usually used.In this Application Note, the chlorinated solvent in the solvent mixture was replaced with toluene, resulting in a more environmentally beneficial method in comparison to ASTM D2710 and IP 299.
- AN-T-207ISO 1841-2準拠による肉製品中の塩化物の測定
この技術資料では、ISO 1841-2に基づく肉製品中の塩化物の自動滴定装置を使用して、Polytronホモジナイザーを使用した自動サンプル前処理工程をを含めて紹介しています。
- AN-T-208Nicotine in e-liquids
The vaping and electronic cigarette industries have grown impressively in the past decade. The mixtures used in these products are usually called «e-liquid», «e-fluid», or «e-juice». To ensure the quality of these e-liquids, testing the most important quality parameters, such as nicotine content, is required. Nicotine in tobacco is usually determined by gas chromatography or liquid chromatography. Aqueous acid base titration is a much more affordable alternative for this determination. As e-liquids do not contain other components which might interfere with the titration, the aqueous acid base titration presented in this Application Note can be applied for nicotine determination. This method is an affordable and reliable way to determine the nicotine content in e-liquids and their nicotine starting material, ensuring the quality of these products.
- AN-T-209エタノール、バイオエタノール、およびバイオ燃料中の電気伝導度 - DIN 15938 に準じた迅速かつ容易な電気伝導度測定
エタノール、バイオエタノール、ならびにバイオ燃料 (E85) は、石油系燃料の代わりとしてますます使われるようになってきています。これらの燃料は、保管中にしばしば、樽、タンクやその他の容器といった金属製物質や表面と接触します。保管中の燃料のイオン濃度が過剰になると、腐食を促進します。燃料マトリックス中に存在するイオン総濃度をモニタリングすることが、効果的な腐食防止策の第一歩であると言えます。イオン総量を測定するための容易で迅速な費用対効果の高いメソッドは、DIN 15938 に則った電気伝導度の測定によるものです。
- AN-T-210Assay of potassium carbonate and potassium bicarbonate
This Application Note presents a potentiometric titration method for a potassium bicarbonate and potassium carbonate assay meeting all USP General Chapter <1225> requirements.
- AN-T-211ワインの完全自動分析 - OIVに準じた遊離亜硫酸、総亜硫酸、還元剤、総酸度、pH値の測定
ワインの還元剤、遊離亜硫酸、総亜硫酸、pH値、総酸度の分析は、OIV-MA-AS323-04B、OIV-MA-AS313-01、OIV-MA-AS313-15を基盤としたOMNIS自動滴定システムにて完全自動で実施することができます。ワインの酸度は、ワインの色と味に影響を与える重要な品質パラメータです。ワインの総酸度およびpH値は、同一のシステムで測定することができます。
- AN-T-212発酵基質中の FOS/TAC 値 - 自動滴定装置によるバイオガスプラントをモニタリング測定
FOS/TAC値は、時にVFA/TAと呼ばれ、バイオガスプラントの消化装置における嫌気性消化プロセスの現在の状況と発展過程の両方を評価するのに重要なパラメータです。この値を知ることは、消化プロセス全体がコストのかかるクラッシュを起こしかねない酸性化の問題のリスクを抑えるのに役立つことがあります。そのため、FOS/TAC 値の正確かつ信頼度の高い測定は、効率的かつコストパフォーマンスが高い生産操業のために重要です。この値は、酸塩基滴定によって測定されます。Ecotrode plus 電極を装備したメトロームの自動滴定装置 Ecoタイトレータ―を用いることで、FOS/TAC 値の再現性がある正確な測定が可能となります。
- AN-T-213Ozone in water
Water treatment with ozone (O3) is a common procedure for the disinfection of swimming pools. It is important that a sufficient but not excessive amount of O3 is produced to disinfect the water. Otherwise, the remaining ozone could enter the swimming water, which could irritate the respiratory system or the skin of bathers.Ozone is also used in drinking and waste water treatment because it is significantly more effective than chlorine at inactivating or killing viruses and bacteria. This application note describes a method to determine the ozone concentration in water by potentiometric titration according to DIN 38408-3.
- AN-T-214Kjeldahl nitrogen in waste water
Nitrogen-based compounds are widely distributed in the environment and are essential growth nutrients for photosynthetic organisms. Therefore, it is important to monitor and control the amount of nitrogen compounds which are released into the environment.In this Application Note, a method to determine the nitrogen content in water by Kjeldahl digestion and distillation followed by a photometric or potentiometric titration according to ASTM D3590 is presented. The universality, precision, and reproducibility of the Kjeldahl method have made it the internationally recognized method for e.g. estimating the protein content in many matrices and it is the standard method to which all other methods are judged against.
- AN-T-215水酸化リチウムと炭酸リチウムの分析
リチウム塩(炭酸リチウムや水酸化リチウムなど)はリチウムイオン電池の電解質やカソード材料の製造など、様々なアプリケーションに使用されており、自動滴定装置を使用して製造工程の品質管理が行えます。 水酸化リチウムは、車や航空機の重要な潤滑剤であるステアリン酸リチウムの製造にも使用されています。さらに空気清浄剤としても使用されています。 炭酸リチウムは大半がアルミニウムの製造に使用されていますが、ガラスやセラミック業界でも使用されています。さらに鬱病や双極性障害などの精神疾患の治療薬にもなっています。 様々な製造工程で使用される高純度のリチウム塩の品質を把握しておくことが重要です。この資料ではOMNIS滴定装置を使用して水酸化リチウムおよび炭酸リチウムの測定例を紹介しています。
- AN-T-216硝酸リチウムの測定
硝酸リチウムは吸湿性の物質であるため、合成やその他の用途に使用する前に純度の検証が必要です。純度は全自動滴定システムを使用して簡単に測定できます。この分析は、エタノール溶液中でのリチウムとフッ化物の沈殿滴定によって行われます。滴定の利点は、ICP-MS などの他の技術のように、硝酸リチウムをエタノールに溶解した後に希釈する必要がないことです。
- AN-T-217Hypochlorite and sodium chloride in disinfectant
Sodium hypochlorite and sodium chloride can be effectively use as disinfectant for water and surfaces. The World Health Organization (WHO) recommends, depending on the application, concentrations in disinfectants of 1000 mg/L to 5000 mg/L NaOCl and up to 200 g/L NaCl.This Application Note demonstrates a reliable method to determine the hypochlorite and sodium chloride content in disinfectants by two subsequent argentometric titrations in the range recommended by the WHO.
- AN-T-218コバルト、ニッケル、マンガンからなるリチウムイオン電池正極材料の完全自動滴定
ニッケル、コバルト、マンガン酸化物の混合物である、いわゆる「NCM」は、酸化コバルトなどの従来の化合物に代わる正極材料として注目を集めています。焼結後の材料やリサイクル電池の品質分析は滴定で可能です。この技術資料ではOMNIS とオプションのピペッティングを組み合わせたシステムによる完全自動滴定システムでの測定例を紹介しています。
- AN-T-219pH value and TTA in flour, dough, and bread
In order to consistently manufacture high quality baked goods, it is critical to measure the pH value and acidity content in the raw materials and during the production steps. These factors have a major influence on the taste and storage lifetime of the final product. Consistent product quality is only possible with precise measurements during the process.This Application Note describes the measurement of pH value and the total titratable acidity in flour, dough, and bread using the Eco Titrator from Metrohm.
- AN-T-220Sodium chloride content in dough and bread
If consumed in excess, sodium may damage the cardiovascular system. It is therefore in the interest of food manufacturers to reduce the salt content and while preserving the flavor of the food.To ensure consistent quality, it is critical to know the exact salt content in the raw materials and the final products. This is only possible by performing precise measurements during the production process.This Application Note explains the determination of sodium chloride in dough and bread quickly according to AOAC 971.27 with the Eco Titrator equipped with an Ag Titrode.
- AN-T-221SET titration of HPLC mobile phases
This Application Note shows the automatic pH adjustment of a mixture of acetonitrile, water and amine using a Metrohm titrator.
- AN-T-222Sulfur dioxide content in traditional Chinese medicines
Traditional Chinese medicine (TCM) remedies are gaining popularity in other cultures. In some TCM, sulfur dioxide (SO2) is used as a preservative, antioxidant, and disinfectant. The products are treated by sulfurization with SO2 gas. However, sulfur dioxide is a very poisonous gas. Global health authorities have set strict limits for the content of SO2 in products. It is therefore of crucial importance to determine the sulfur dioxide content to comply with these limits. In this well-suited method, the SO2 content in different natural TCM products are analyzed reliably and accurately according to ISO 22590 using the Eco Titrator equipped with an Optrode and sodium hydroxide as titrant.
- AN-T-223自動滴定装置による電気めっき浴の完全自動分析
電気めっきは、製品の表面を腐食や摩耗から保護し、その使用寿命を大幅に延ばすために利用されています。電気めっき浴の代表的な例としては、アルカリ性の脱脂浴、銅、ニッケル、クロムなどの金属や、塩化物、シアン化物といった成分を含む酸性またはアルカリ性の浴液です。OMNIS サンプルロボットシステムは、自動的にサンプルをピペッティングし、分析を行うことで、手動滴定と比較してより信頼性の高い結果が得られ、複数のパラメータを並行して分析できるため、時間効率も向上します。
- AN-T-224Aluminum content in coagulants and flocculants for wastewater treatment
Coagulation and flocculation are an essential part of treating both drinking water and wastewater. Aluminum salts such as aluminum sulfate and polyaluminum chloride (PAC) are often used for this purpose. For the precise application and exact dosage of the flocculant, it is important to accurately determine its aluminum content. In this Application Note, the aluminum content is accurately and reliably analyzed based on ABNT NBR 11176 using the 859 Titrotherm equipped with a Thermoprobe HF and sodium fluoride as titrant.
- AN-T-225自動滴定装置によるコーヒー中のカフェイン、pH、酸度の自動分析
コーヒーの味に影響を与える主な要因の多くは、測定可能な化学的特性と相関しています。これには、pH、滴定酸度、屈折率、およびカフェインが含まれます。これらの分析の多くは、従来、時間のかかる液体クロマトグラフィー(LC)技術を使用した手間のかかる手動のサンプル準備プロセスを含んでいました。 この技術資料では、単一の滴定プラットフォームであるOMNISを使用して、コーヒーの主要な品質パラメータを分析するためのより速く、簡単な代替方法について説明します。
- AN-T-226Determination of functional groups in graphite and graphene oxide
Boehm titration is a quantitative analysis of functional groups on the surface of carbon materials based on their reactions with basic solutions of NaHCO3 (pKa = 6.4), Na2CO3 (pKa = 10.3), and NaOH (pKa = 15.7). This is a cost-efficient method that gives absolute values with high precision of the accessible, mainly oxygen-containing functional groups on the surface. Originally, Boehm titration was developed for carbon materials like conductive carbon black (CCB), activated carbon, porous carbon, and graphite. Modern carbon-based materials like graphene, graphene oxide (GO), or carbon nanotubes can also be analyzed this way.
- AN-T-227Determination of sodium lactate
Sodium lactate is a salt form of lactic acid used in many regulated industries—therefore an accurate determination of the lactate content is required and is already covered in several norms. One such monograph by the US Pharmacopoeia (USP) results in high accuracies and well-defined titration curves but uses titrants and solvents that are more costly than necessary. In comparison, the presented modified method from Metrohm requires a 1:1 mixture of water and acetone and uses aqueous hydrochloric acid as titrant, resulting in an estimated cost reduction of 40% per titration compared to the USP method (USP–NF 2021, Issue 2). Furthermore, the time needed for each analysis is reduced to just 12% of the USP method (excluding blank determination). This Application Note presents both methods to determine lactate content and shows the results obtained on an OMNIS system.
- AN-T-229甜菜ジュース中の石灰塩の測定 – 信頼性が高く、安価な錯滴定メソッド
この技術資料では、サトウキビのジュース中に含まれるカルシウム化合物を測定する方法を紹介しています。砂糖溶液中の石灰塩の濃度(特に薄液と濃厚液)の制御が重要です。これらのサンプル中の石灰塩の濃度を測定するために、錯滴定がしばしば用いられます。 自動滴定装置にイオン選択電極(ISE)を使用することで、色の変化の判断の主観性が排除されます。
- AN-T-230Quantification of 1,2-diols by iodometric redox titration
Mannitol content determination is an important aspect of quality control in the pharmaceutical and food industries. Selective oxidative cleavage can be used to quantify the amount of 1,2-diol groups in the analyte. Determining the 1,2-diol content by iodometric titration can be fully automated for the most accurate results using an automated titrator and the dPt Titrode from Metrohm.
- AN-T-231自動滴定装置による非水溶媒中のカフェインの測定
さまざまな非水製品(非水系溶媒中)のカフェイン含有量を、逆滴定ではなく、正滴定で正確に測定できます。dSolvotrode電極を使用した OMNIS 自動滴定装置は、高性能ソフトウェアと組み合わせた柔軟な分析により、カフェインの非水滴定を正確におこなえます。
- AN-T-232ヨウ素逆滴定法によるカフェインの測定
ヨウ素逆滴定は、さまざまな水性サンプル中のカフェイン含有量を正確に測定するために使用される正確な方法です。この技術資料では、dPt 電極を備えた OMNIS 滴定装置を使用したヨウ素逆滴定法により、水性サンプル中のカフェイン含有量を正確に測定しています。
- AN-T-233自動滴定装置によるピロリン酸塩の測定
この技術資料では、OMNIS サンプル ロボット S と dUnitrode電極を搭載したOMNIS 電位差自動滴定装置を使用して、水溶液中のピロリン酸塩含有量を正確に測定する方法を紹介しています。
- AN-T-234混合酸と TMAH の滴定で メトロームの滴定装置OMNIS と Titrando の比較実験
この技術資料は、メトロームの自動滴定装置OMNIS と 888タイトランドの両方を保有している台湾のお客様が、実際に比較実験して、アルミニウム エッチング浴中の硝酸、リン酸、酢酸の測定、水酸化テトラメチルアンモニウム (TMAH) の濃度定量をしたデータをいただいたものです。同一の分析パラメーターが使用され、OMNIS が他の滴定装置と同等またはそれ以上の結果をもたらすことが示されました。
- AN-T-235カーボンブラックのpH測定
この技術資料では、ASTM D1512およびISO 787-9、GB/T 1717に準拠したpH電極を装備した913 pHメーターを使用して、カーボンブラック中のpH値を正確かつ確実に分析します。
- AN-T-236電位差滴定による水酸化ナトリウム滴定溶液を用いた塩酸の定量
塩酸は強い無機鉱酸であり、化学工業において非常に重要な役割を担っています。塩酸を水酸化ナトリウムで電位差滴定する方法は、実験室で行われる最も重要かつ頻繁な分析の一つです。本アプリケーションノートでは、pH電極に統合されたPt1000温度センサーを用いて、最も正確な結果を得るためにNaOHで塩酸の濃度を測定する酸塩基滴定法をご紹介します。
- AN-T-237自動滴定装置を使用した水酸化ナトリウムによるリン酸の定量
リン酸は三価の無機酸で、多くの用途に使用されます。リン酸は、リン酸肥料の製造原料、洗剤、リン酸燃料電池の電解質、錆除去剤、鉄や亜鉛のパッシベーションによる防食などに用いられます。この技術資料では、リン酸の濃度を水酸化ナトリウムで滴定し、すべての解離可能なプロトンを含む濃度を測定する酸-塩基滴定の方法が紹介されています。
- AN-T-238水サンプルのアルカリ度(P-アルカリ度およびM-アルカリ度)の滴定
アルカリ度(時には水の酸消費量とも呼ばれる)は、酸を中和する能力の指標となります。主に炭酸水素塩や炭酸塩含有量に依存して決まります。したがって、総アルカリ度(M-アルカリ度)と炭酸塩アルカリ度(P-アルカリ度)の区別がなされます。 総アルカリ度(M-アルカリ度)は、塩酸を滴定溶液とした滴定によりpH 4.5まで行われます(pH4.5は、指示薬メチルオレンジの変色点となります。)。終点をpHが8.3とした場合は、炭酸塩アルカリ度(P-アルカリ度)となります。(pH 8.3は、指示薬フェノールフタレインの変色点となります。) この技術資料では、滴定による水のpHとアルカリ度の測定方法を解説しています。この手法は、EPA 310.1、標準方法2320 B(滴定法)、ASTM D1067、さらにEN ISO 9963-1と9963-2、上水試験法、JIS K 0400-15-10及び-20に準拠しています。(JIS k 0400-15-20 の終点は、pH5.4ですが、滴定装置の設定を変更することで対応できます。)
- AN-T-239過塩素酸による弱塩基の非水滴定
この技術資料は、アミンの非水過塩素酸滴定について紹介しています。トリエタノールアミン (TEA) の濃度は、ソルボトロード・イージークリーン (Solvotrode easyClean) 電極と塩化リチウム-エタノールを電解液(電極内部液)として用い、過塩素酸-氷酢酸溶媒で滴定します。
- AN-T-240導電率滴定法を用いた全酸価(TAN:Total Acid Number)の測定
全酸価(TAN:Total Acid Number)は、油類や燃料の酸性度を評価するうえで重要な指標です。本アプリケーションノートでは、導電率滴定法を用いてTANを測定します。
- AN-T-242ASTM D3242 に基づく航空タービン燃料の酸価
本アプリケーションでは、自動滴定装置と オプトロード を用いた光度滴定法により、ASTM D3242 に準拠したジェット燃料中の酸価を完全自動で測定する手法を説明します。
- AN-T-243ビート糖中の亜硫酸塩の測定
本実験では、OMNIS 電位差自動滴定装置と Pt ティトロードを電極として用いた、ビート結晶糖中の低濃度亜硫酸塩の電位差自動滴定について説明します。
- AN-T-244チオ硫酸ナトリウム滴定溶液の標定
本アプリケーションノートに示すように、Pt ティトロードを装備した OMNIS ティトレーターは、希釈された滴定液であっても濃度を正確かつ信頼性高く測定できます。
- AN-T-245二相滴定法によるイオン性界面活性剤の光度滴定
本研究で示すように、OMNIS システムを用いることで、Epton 二相滴定法によるイオン性界面活性剤の正確かつ信頼性の高い測定が可能です。
- AN-T-246硝酸銀滴定溶液を用いた沈殿滴定法によるカチオン性界面活性剤の純度測定
本アプリケーションでは、陽イオン性界面活性剤 TEGOtrant の標準化を、電位滴定法および近赤外分光法(NIRS)を用いて実施します。
- AN-T-247EN 14104 に準拠した光度滴定法によるバイオディーゼルの酸価
バイオディーゼルのような脂肪酸メチルエステル(FAME)の酸価は、OMNIS と Optrode を用いた光度滴定法により、EN 14104 に準拠して測定することができます。
- AN-T-249ISO 23597に基づく希土類元素の分析
このアプリケーションでは、ISO 23597に基づく希土類元素(REE)の純度分析を紹介しています。キシレノールオレンジを用いた絶対錯滴定法により、校正不要で約100%の回収率を達成。Optrode M2 センサーによる光度滴定は、高精度・高再現性・高効率な分析を実現します。
- AN-T-250自動滴定装置によるレアアーズ (REEs) の分析
このアプリケーションでは、希土類元素(REE)の定量に適したCu-ISEによる電位差逆滴定法を紹介しています。複雑なマトリックス中でも高い回収率で選択的な定量が可能で、ICPと同様の試料前処理に対応する、迅速かつ費用対効果に優れた絶対分析法です。
- AN-U-001Nickel, zinc, cobalt, iron(II), and manganese in lithium bromide using post-column reaction
Determination of nickel, zinc, iron(II), and manganese in lithium bromide using cation chromatography with UV/VIS detection (520 nm) after post-column reaction.
- AN-U-002Bromide and nitrate in 1% sodium chloride
Determination of bromide and nitrate in 1% sodium chloride solution using anion chromatography with UV/VIS detection (205 nm) after chemical suppression.
- AN-U-003Glycolic and lactic acid in the presence of N-methyl pyrrolidone
Determination of glycolic and lactic acid in the presence of N-methyl pyrrolidone used in drug delivery systems using ion-exclusion chromatography with UV/VIS detection.
- AN-U-008Trace anions in magnesium chloride (MgCl2) using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection
Determination of traces of fluoride, bromide, nitrate, phosphate, and sulfate using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection.
- AN-U-009Iodate, chlorite, bromate, and nitrite by suppressed ion chromatography using a post-column reaction (PCR) and UV/VIS detection
Determination of iodate, chlorite, bromate, and nitrite using suppressed anion chromatography with UV/VIS detection after post-column reaction.
- AN-U-010Nitrite, nitrate, and phosphate in seawater from a shrimp farm
Determination of nitrite, nitrate, and phosphate in seawater from a shrimp farm using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection.
- AN-U-011N-acetylcysteine in a medication against sinusitis according to USP
Determination of N-acetylcysteine and phenylalanine in tablets against sinusitis by anion chromatography with UV/VIS detection according to USP.
- AN-U-012Trace iodide in bottled water using anion chromatography with UV/VIS detection
Determination of traces of iodide in bottled water using anion chromatography with UV/VIS detection.
- AN-U-013HEDPA, PBTC, and NTP
Determination of HEDPA, PBTC, and NTP using anion chromatography with UV/VIS detection after post column reaction (PCR).
- AN-U-014Bromide in calcium chloride using UV detection
Determination of bromide in calcium chloride using anion chromatography with UV/VIS detection.
- AN-U-015Chromium(VI) in a leather extract
Determination of chromium(VI) (chromate) in leather extract using anion chromatography with UV/VIS detection after post-column reaction (PCR) and inline dialysis for sample preparation.
- AN-U-016Caffeine in cola soft drinks
Determination of caffeine in a cola soft drink using RP chromatography with UV/VIS detection.
- AN-U-018Bromate determination using post-column reaction (o-dianisidine method)
Determination of bromate in water using anion chromatography with UV/VIS detection after post-column reaction (PCR) with o-dianisidine reagent (described in EPA 317.0).
- AN-U-022Traces of nitrite in mineral water with UV detection
Determination of nitrite in mineral water using anion chromatography with UV detection.
- AN-U-023Nitrite, bromide, nitrate, and iodide in 10 g/L sodium chloride with UV detection
Determination of nitrite, bromide, nitrate, and iodide in 10 g/L sodium chloride using anion chromatography with UV detection.
- AN-U-024Vanadium speciation using ion chromatography with UV/VIS detection
Determination of vanadium(IV) and vanadium(V) in Benfield solution using anion chromatography with UV detection.
- AN-U-025Saccharin and its degradation products (benzamide, o-toluenesulfonamide) in a nickel electroplating bath
Determination of saccharin, benzamide, and o-toluenesulfonamide in a nickel electroplating bath using RP chromatography with UV detection.
- AN-U-026Phenylalanine, aspartame, caffeine, and benzoate in soft drinks
Determination of phenylalanine, aspartame, caffeine, and benzoate in a soft drink using RP chromatography with UV detection.
- AN-U-027System suitability test for cefazolin in accordance with USP
Determination of cefazolin in accordance with USP 28-NF 23 (Appendix 2) using RP chromatography and subsequent UV detection. Keyword: Antibiotics
- AN-U-028Salicylic acid impurity in aspirin tablets according to the USP method
Determination of salicylic acid and acetylsalicylic acid according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
- AN-U-029Analysis of cloxacillin sodium in accordance with USP
Determination of cloxacillin sodium in accordance with USP 28-NF 23 (Appendix 2) using RP chromatography and subsequent UV detection. Keyword: Antibiotics
- AN-U-030System suitability test for amoxicillin in accordance with USP
Determination of amoxicillin in accordance with USP 28-NF 23 (Appendix 2) using RP chromatography and subsequent UV detection. Keyword: Antibiotics
- AN-U-031Sulfur species in process water of the paper industry by simultaneous conductivity and UV detection
Determination of sulfide and thiosulfate in a process water using anion chromatography with UV/VIS detection after chemical suppression and conductivity detection.
- AN-U-032Sulfide in a raw sodium vanadate solution by UV detection
Determination of sulfide in a raw vanadate solution using anion chromatography with UV/VIS detection.
- AN-U-033Assay of theophylline tablets according to the USP method
Determination of theophylline and theobromine according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
- AN-U-034Chromatographic purity determination of ibuprofen according to USP
Determination of valerophenone and ibuprofen according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
- AN-U-035Chromatographic purity determination of thiamine hydrochloride according to USP
Determination of thiamine hydrochloride according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
- AN-U-036Assay determination of ranitidine HCl according to USP
Determination of ranitidine hydrochloride according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
- AN-U-037System suitability test for penicillin G potassium in accordance with USP
Determination of penicillin G potassium and 2-phenyl acetamide in accordance with USP 28-NF 23 (Appendix 2) using RP chromatography and subsequent UV detection. Keyword: Antibiotics
- AN-U-038Sulfide in mining wastewater
Determination of sulfide in mining wastewater using anion chromatography with UV detection.
- AN-U-039Polybromated flame retardant in polymers in accordance with the IEC 62321 method for RoHS testing
The determination of PBBE (tetrabromobisphenol A - TBBPA, octabromodiphenyl ether - OCTA and decabromodiphenyl ether - DECA) in a polymer sample was carried out with the Nucleosil EC - 250 mm column; for this purpose a methanol and phosphate buffer was used as an eluent and subjected to UV detection in accordance with the IEC 62321 method for RoHS testing.
- AN-U-040Chromium(VI) in colorless and colored chromate coating on metallic samples as per IEC 62321 method for RoHS testing
The determination of chromium in metal plate samples using anion exchange chromatography with UV/VIS detection after post-column reaction with diphenylcarbazide as per IEC 62321 method for RoHS testing. This method provides procedures for the determination of the presence of chromium(VI) in colorless and colored chromate coatings on metallic samples.
- AN-U-041Chromium(VI) in polymers as per IEC 62321 method for RoHS testing
The determination of chromium(VI) polymers using anion exchange chromatography with UV/VIS detection after post-column reaction with diphenylcarbazide as per IEC 62321 method for RoHS testing.
- AN-U-042Melamine in food using cation chromatography with UV/VIS detection
Determination of melamine in milk, diary products, eggs, and egg-based foodstuffs using cation chromatography.
- AN-U-043Sample determination of cefadroxil in accordance with USP
Determination of cefadroxil in accordance with USP 28-NF 23 (Supplement 2) using RP chromatography with UV detection. Keyword: Antibiotics
- AN-U-044Arsenite and arsenate in process water
Determination of arsenite and arsenate in process water using ion-exclusion chromatography with UV detection.
- AN-U-045Aluminum in phosphoric acid using UV/VIS detection after post-column reaction with catechol violet
Determination of aluminum in phosphoric acid using cation chromatography with UV detection after post-column reaction with catechol violet.
- AN-U-046Aluminum in an acid extract using UV/VIS detection after post-column reaction with Tiron
Determination of aluminum in an acidic extract containing metals (e.g., alkali, alkaline earth, iron, chromium, molybdenum, etc.) using cation chromatography with UV detection after post-column reaction with Tiron.
- AN-U-047サンプル自動前処理(インライン透析)を使用したイオンクロマトグラフィーによる冷却潤滑剤中の硝酸塩と亜硝酸塩の測定
イオンクロマトグラフでサンプル自動前処理システム(インライン透析)をを使用し、時間のかかるサンプル前処理工程を自動化して、冷却潤滑剤中の硝酸塩と亜硝酸塩を自動分析したアプリケーションです。
- AN-U-048Silicate and hexafluorosilicate
Determination of silicate and hexafluorosilicate (calculated) using anion chromatography with conductivity detection after chemical suppression (see AN S-277) and subsequent UV/VIS detection with post-column reaction. Hexafluorosilicate is hydrolyzed into fluoride and silicate. Both anion concentrations may be used for the calculation of the SiF62- concentration.
- AN-U-049Analysis of bromate in drinking water according to ISO 11206 and EPA 317
Ion chromatography with PCR and UV/VIS detection provides a highly specific and sensitive method for bromate analysis, meeting EPA Method 317 and ISO 11206 requirements.
- AN-U-052Transition metal cations applying UV/VIS detection after post-column reaction with PAR (4-(2-pyridylazo)resorcinol)
The Metrosep C 4 columns are mainly used for the separation of alkali and alkaline earth metal cations including ammonium and organic amines. Additionally transition metals may be determined.
- AN-U-053Chromate with 887 Professional UV/VIS Detector and 886 Professional Thermostat / Reactor
Chromate (Cr(VI)) or hexavalent chromium is carcinogenic. Its use is restricted. Chromate has to be analyzed in a large range of products starting with drinking water, wastewater (e.g., from leather production), over toys to RoHS-regulated substances. Besides ion chromatographic determination applying conductivity detection, the method described here is suitable especially for lower concentrations.
- AN-U-054Amino acids applying UV/VIS detection after post-column reaction with ninhydrin at 120 °C
The determination of amino acid is an important task in pharmaceutical and biochemical applications. A binary gradient separates in this example 17 amino acids of a commercially available standard solution. The post-column reaction with ninhydrin requires a temperature of 120 °C, while the samples need to be cooled for stability.
- AN-U-055Amino acids in cell culture growth medium applying UV/VIS detection after post-column reaction with ninhydrin at 120 °C
Cell culture growth media contain all required components to keep cells alive. Here the amino acid composition is analyzed. A binary gradient separates in this example amino acids. The post-column reaction with ninhydrin requires a temperature of 120 °C, while the samples need to be cooled for stability.
- AN-U-056Nitrite, bromide, and nitrate in artificial sea water applying direct UV/VIS detection
Seawater analysis with conductivity detection is difficult due to the high excess of chloride. Especially analyzing for nitrite and bromide, UV/VIS detection is preferred as chloride is not interfering with nitrite at 218 nm. This AN shows the determination of all three UV-absorbing anions in an artificial seawater.
- AN-U-057Chromate in drinking water by ion chromatography with PCR and UV/VIS detection, according to EPA Method 218.7.
Hexavalent chromium (chromate) is known to be carcinogenic if inhaled, and suspected to be carcinogenic if ingested. EPA Method 218.7 allows to determine chromate in drinking water down to the sub-µg/L range (method detection limit, MDL = 15 ng/L). Post-column reaction with 1,5-diphenylcarbazide and subsequent visible detection at 530 nm is applied.
- AN-U-058ポストカラム反応とそれに続くUV/VIS検出器を用いた染料サンプル中のクロム酸塩の定量
染料サンプル中の微量クロム酸を分析します。クロム酸(Cr(VI))は毒性があり、発がん性がある可能性があるため、濃度は可能な限り低く抑える必要があります。このサンプルはC18カートリッジで調製し、メトロームのインテリジェント前濃縮技術(MiPCT)を用いて注入します。注入のたびに、前濃縮カラムを洗浄してマトリックス効果を除去する必要があります。この目的には、800 Dosino以外の機器は必要ありません。このシステムは、20~2000 µLのサンプル量に最適化されています。ほとんどのサンプルでは、前濃縮カラムの洗浄は不要です。
- AN-U-059Transition metals in feedwater using post-column reaction and subsequent UV/VIS detection
Feedwater for steam generation in boiling water reactors (BWR) needs to be analyzed for corrosion products. Presence of transition metals, mainly nickel and iron, indicates corrosion problems. Traces of these ions are determined using Inline Preconcentration (MiPCT). After separation, post-column reaction with 4-(2-pyridylazo)resorcinol (PAR) allows VIS detection at 510 nm.
- AN-U-060Corrosion inhibitors in cooling water
In industrial cooling water systems, copper and its alloys are widely used because of their superior heat transfer properties. These materials are, however, susceptible to corrosion. Azoles are commonly used to protect copper and its alloys from corrosion. These corrosion inhibitors are quantified by ion chromatography with UV/VIS detection.
- AN-U-061Speciation of iron(II) and iron(III) applying post-column reaction and subsequent UV/VIS detection
Speciation analysis is an important tool in analytical chemistry giving information about the quantitative distribution of different oxidation states of one and the same metal ion. The speciation of iron(II) and iron(III) (Fe 2+/Fe 3+) is achieved by ion chromatographic separation of their anionic dipicolinic acid complexes. Afterwards, post-column reaction with 4-(2-)pyridylazo-resorcinol (PAR) allows VIS detection at 510 nm.
- AN-U-063Bromate in flour applying Inline Dialysis and conductivity as well as UV/VIS detection and PCR
Potassium bromate is used as a flour improver. The determination of the carcinogen bromate in flour requires extraction and additional sample preparation. In this application, Inline Dialysis is used after sonication and centrifugation of the extraction mixture. Bromate is detected by conductivity following suppression and UV/VIS detection and post-column reaction.
- AN-U-065Iodate and iodide in an electroplating bath applying direct UV/VIS detection
The determination of iodate and iodide in used electroplating baths is a demanding task due to the high concentration of other ions. Iodate is used as a stabilizer for the bath and needs to be checked for proper electroplating. The use of a sodium chloride eluent, the Metrosep A Supp 5 - 250/4.0 column and direct UV/VIS detection permits the analysis of these samples without matrix interferences.
- AN-U-066EN 13368-1に準拠したEDTA、HEDTA、DTPAの定量
キレート剤(錯化剤)は、コバルト、鉄、マンガンなどの微量栄養素と結合させるために肥料中で使用されています。 EN 13368-1 では、EDTA、HEDTA、および DTPA の定量方法が規定されています。サンプルの前処理として、これら3種のキレート剤と錯体を形成させるためにFe³⁺(三価鉄)を添加します。 生成された錯体は陰イオン交換カラム上で分離され、過塩素酸を添加した後に紫外可視吸光光度法(UV/VIS)により検出されます。
- AN-U-067Trace determination of transition metals with preconcentration (MiPCT), post-column reaction, and UV/VIS detection
The determination of transition metals by ion chromatography is possible with direct conductivity detection (see AN-C-137) as well as with UV/VIS detection after post-column reaction. Here, the cations are separated as anionic complexes and analyzed after post-column reaction with PAR with subsequent UV/VIS detection. Speciation determination of iron (separation of Fe(II) and Fe(III)) is possible with this procedure. For trace analysis, Metrohm Inline Preconcentration Technique (MiPCT) is applied.
- AN-U-068EU指令 2018/725 に準ずる玩具から泳動するクロム酸の測定
クロム酸 (Cr(VI)) は、発がん性、変異原性があり、DNA に損傷を与えるとみなされているため、Cr(VI) 濃度はできる限り低く保つべきだとされています。EU 玩具安全指令 2018/725 は、玩具から遊離するクロム酸の泳動限界値を定めています。「HCl 泳動溶液」は、マトリックス除去を伴う Metrohm インテリジェント予備濃縮技術 (MiPCT-ME) によって 2.000 µL が注入される前にバッファーにて希釈されます。測定は、ジフェニルカルバジドによる誘導体化に後続する VIS 検知によって実施されます。
- AN-U-069Chromate using post-column reaction and UV/VIS detection in accordance with EPA 218.7
Hexavalent chromium (Cr(VI)) is regarded as being toxic and potentially carcinogenic. Its concentration in drinking water should therefore be kept as low as possible. The determination of Cr(VI) is performed using ion chromatography. The separation takes place on the Metrosep A Supp 10 - 250/2.0 separation column. The presence of Cr(VI) is determined photometrically following post-column reaction (PCR) with diphenylcarbazide.
- AN-U-070Paracetamol in tablets with fully automatic sample preparation using 815 Robotic Soliprep for LC
Paracetamol is an effective antipyretic and analgesic. Its determination in tablets using reverse phase chromatography and UV detection is quick and easy with the sample preparation described in this Note. The 815 Robotic Soli Prep for LC does everything automatically: from dissolving the tablets, homogenizing and filtering, to 250-nL-Loop injection.
- AN-U-071UV/VIS検出器を用いた人工海水に含まれる亜硝酸塩、臭化物、および硝酸塩の測定
海水中の陰イオンのイオンクロマトグラフによるトレース分析は、高濃度の塩化物のため困難です。塩化物とは対照的に、亜硝酸塩、臭化物および硝酸塩は、波長域の低いUV照射を吸収し、これら3つの陰イオンのUV検出を可能にします。 この Application Note は、塩化ナトリウム溶液によるカラム型Metrosep Carb 2 - 100/4.0における分離について説明しています。これは、過剰塩化物による影響を最小限に抑え、低い検出限界を実現します。
- AN-U-072UV/VIS検出を用いた、ベンフィールド溶液中にEDTA錯体として含まれるバナジウム (IV) およびバナジウム (V) の種分化
ベンフィールド法は、石油および工業ガスからH2SおよびCO2を取り除くための手順としてよく知られています。五酸化バナジウムは腐蝕防止剤として添加され、V(IV)/V(V)が一定の比率にある際に最も効果を発揮します。そのため、V(IV)およびV(V)の種分化と測定は重要です。この種分化は、A Metrosep A Supp 5 - 50/4.0カラムにて、EDTAを溶離液として、282 nmのUV/VIS検出とともに容易に実施することができます。
- AN-U-073過塩素酸塩溶離液およびUV/VIS検出を適用するイオンクロマトグラフィーによる鉱山浸出液における硫黄の種分化
金鉱山では、青酸塩の浸出から、毒性のより低いチオ硫酸塩の浸出プロセスに切り替わる傾向があります。チオ硫酸塩の浸出は、金を最大限に回収し試薬の損失を抑えるための浸出反応の成分の更なる最適化を要する、慎重に取り扱うべきプロセスです。亜硫酸塩、チオ硫酸塩、チオシアン酸塩、およびテトラチオン酸塩は、Metrosep A Supp 5 - 250/4.0カラムにて分離されます。ほとんどの金属過塩素酸塩は水溶性であるため、過塩素酸が溶離液として選択されます。これにより、ICシステム中での金属の沈殿を防ぐことができます。
- AN-U-074UV/VIS検出を伴うイオンクロマトグラフィーによるタバコ中の亜硝酸塩および硝酸塩の測定
タバコに含まれる亜硝酸塩は、タバコ特有のニトロソアミンの解放を促進します。これらニトロソアミンの多くは発がん性を有します。そのため、タバコに含まれる亜硝酸塩の測定が必要とされます。この application では、タバコの酢酸抽出物における亜硝酸塩および硝酸塩の測定について説明しています。イオンクロマトグラフィーによる分離の後、連続サプレッションを伴うUV/VIS検出が実施されます。
- AN-U-075UV/VIS検出を伴うイオンクロマトグラフィーによるワクチン中のアルミニウム (Al3+) の測定
アルミニウムは (ゲルまたは塩で)、アジュバントとしてワクチンに用いられます。これは、免疫反応の増強を補助します。ワクチンに含まれるアルミニウムの量は、USP などによって規制されています。USP によれば、1回のワクチン投与量に含まれる Al3+ の最大量は 0.85 から 1.25 mg の間です。この記事では、UV/VIS 検出を伴うイオンクロマトグラフィーによる 8-ヒドロキシキノリン錯体としてのアルミニウムの測定について説明しています。
- AN-U-076USP 総則 <591>1)に準拠した酸化亜鉛の分析
USPは、総則<591>「亜鉛の測定」モノグラフを、分析のためのメソッドとしてイオンクロマトグラフィーを含むものと更新しています。酸化亜鉛は、様々なスキンケアクリーム、薬剤、製剤に使われています。イオンクロマトグラフィー分析は、例えばL91 (Metrosep A Supp 10)などを用いた亜鉛の分離に続いて、4-(2-ピリジルアゾ)レゾルシノール (PAR) 試薬を用いたポストカラム反応、および後続する波長 530 nm での検出を含みます。キーワード: USP<591>
- AN-U-077EN ISO 15192 (消化された土壌) および EN 16318 (肥料) に準じた強アルカリ消化溶液中のクロム酸塩
土壌中の六価クロム (クロム酸塩) は発がん性を有するため、最小限に抑える必要があります。クロム酸塩は、Cr(VI)を含む肥料を使用することで土壌に取り込まれる場合があります。このクロム酸の多くは、有機物の酸化にょってCr(III)に還元されます。残存するクロム酸塩は、1,5-ジフェニルカルバジドによるポストカラム反応およびそれに続く538 nmでの可視検出を伴うイオンクロマトグラフィーの後続するアルカリ消化により、ISO 15192に準じて測定されます。EN 16318の工程Bはアルカリ消化と、肥料と同じ分析工程を採用しています。
- AN-U-078冷却剤中のケイ酸塩の測定
スケールの形成は、オペレーションに莫大な損失を与えるシステムダメージを引き起こし得る冷却システムの重大な問題です。スケール形成において重要な成分の1つがシリカです。非晶質シリカと金属ケイ酸塩は、特にスケールを形成しやすい傾向があります。それゆえ、冷却剤中のシリカの濃度を知ることは重要です。UV/VIS検出およびPCRを伴うイオンクロマトグラフィーにより、遊離ケイ酸塩量および総ケイ酸塩量の両方を測定することができます。超純水でのサンプルの希釈、ならびに直接注入により、遊離ケイ酸塩の濃度が導き出されます。総ケイ酸塩量は、アルカリ性溶離液でのサンプル希釈による非結晶シリカの加水分解、ならびに分析前の反応時間 (例えば4時間など) 後の注入の後に測定されます。
- AN-U-079水中のクロム酸塩 (Cr(VI)) の測定
クロム酸塩および二クロム酸塩は、クロムの2つのオキソ陰イオンです。その両方に、クロムは六価の形 (Cr(VI)) で存在しています。水溶液中では、クロム酸塩はアルカリ性条件下に、二クロム酸塩は酸性条件下に存在します。六価クロムは高い有毒性と発がん性を有します。よってそれは、製造品、ならびに自然環境においても制限され、徹底的なモニタリングが要されます。DIN 38405-52 では、測光法による水、廃水、ならびに汚泥中の Cr(VI) の測定について説明されています。付属書Cの第C.6章では、イオンクロマトグラフィーの使用について説明されています。このANでは、飲料水サンプルにおけるメソッドのアプリケーションが示されています。
- AN-U-080Nitrite and nitrate in meat products
Nitrite and nitrate salts are used as preservatives for meat and meat products. Nitrate salts (labeled E 251 or E 252) have a low toxicity but long-term exposure is of concern, as the lower gut reduces them to nitrite, a precursor of nitrosamines (classified as carcinogenic). Nitrite itself is classified as probably carcinogenic to humans. The European Food Safety Authority (EFSA) lists the MPL (maximum permitted levels) after the manufacturing process for nitrite (labeled E 249 or E 250) as between 50–180 mg/kg, and for nitrate between 150–300 mg/kg, depending on the product. The European Commission (Regulation (EC) No 1333/2008) limits nitrate and nitrite salts in processed meat to less than 150 mg/kg. Ion chromatography with UV detection offers a robust and universal method for quality control of nitrite and nitrate in different meat matrices. Additional sample preparation techniques like Inline Ultrafiltration help to save time and costs as well as overcome analysis issues with difficult sample matrices.
- AN-V-001Iron, cadmium, lead, and copper in cobalt acetate solution
Determination of Fe, Pb, Cd, and Cu in Co(Ac)2 solution using the MME.
- AN-V-002Chromium, manganese, and titanium in polyterephthalic acid solution
Determination of Cr, Mn, and Ti in a PTA solution containing HCl.
- AN-V-003Nickel, cobalt, and iron in polyterephthalic acid solution
Determination of Ni, Co, and Fe in a PTA solution containing HCl.
- AN-V-004Zinc, cadmium, lead, copper, and chromium in triglyceride
Determination of Zn, Cd, Pb, Cu, and Cr in triglyceride.
- AN-V-006Cadmium, lead, and antimony in acetic acid
Determination of Cd, Pb, and Sb in acetic acid.
- AN-V-009Cadmium, lead, and copper in brine and sodium hydroxide
Determination of Cd, Pb, and Cu in brine and NaOH.
- AN-V-010Zinc, cadmium, lead, copper, iron, nickel, and cobalt in NaOH in one run
Simultaneous determination of Zn, Cd, Pb, Cu, Fe, Ni, and Co in 50% NaOH.
- AN-V-015Nickel, antimony, cadmium, thallium, and copper in a neutral, highly concentrated zinc solution
Determination of Ni, Sb, Cd, Tl, and Cu in a neutral, highly concentrated zinc solution from the plating industry.
- AN-V-016銀めっき液中のニッケル(Ni)、鉄(Fe)、銅(Cu)の濃度測定
銀めっき液中の ニッケル(Ni)、鉄(Fe)、銅(Cu)の濃度測定を紹介しています。
- AN-V-017銀めっき液中の クロム(Cr) とセレン( Se) の濃度測定
銀めっき液中の クロム(Cr) とセレン( Se) の濃度測定を説明します。
- AN-V-018有機酸めっき液中のスズ(Sn)と鉛(Pb)の濃度測定
有機酸めっき液中のスズ(Sn)と鉛(Pb)の濃度測定について説明します。
- AN-V-019無電解ニッケルめっき液中の鉛(Pb)の濃度定量
無電解ニッケルめっきは、様々な工業生産プロセスで使用されています。プリント回路基板の製造におけるENIG(無電解ニッケル、無電解金)プロセスとENEPIG(無電解ニッケル、無電解パラジウム、無電解金)プロセスは、無電解ニッケルめっきプロセスの最初のステップであるため、この工程の歩留まりに大きく関与しています。めっき不良による規格外製品の量を減らすことで、メーカーは大幅なコスト削減を実現できます。 ディファレンシャル・パルス・アノード・ストリッピング・ボルタンメトリーは、希釈後の活性鉛(Pb)濃度を測定するために使用することができます。ボルタンメトリーによる定量は、この用途において、簡便、高感度、選択的で干渉を受けない方法として確立されています。
- AN-V-022Antimony and bismuth in an alkaline zinc oxide solution in one run
Simultaneous determination of Sb and Bi in an alkaline ZnO solution.
- AN-V-023Aluminum in an alkaline zinc oxide solution
Determination of Al in alkaline ZnO solution with Eriochrome Blue Black R at 60 °C.
- AN-V-024エッチング液中の銅(Cu)とクロム(Cr)の濃度測定
エッチング液中の銅(Cu)とクロム(Cr)の濃度測定について説明します。マンガン(Mn)とニッケル(Ni)の濃度が高いため、銅(Cu)はEDTA錯体として、マンガン(Mn)はDTPA錯体として測定します。
- AN-V-026Iron and zinc in a nickel sulfate bath containing surfactants
Determination of Fe and Zn in a nickel sulfate bath containing surfactants after UV digestion.
- AN-V-027Copper in a nickel sulfate bath containing surfactants
Determination of Cu in a nickel sulfate bath containing surfactants after UV digestion.
- AN-V-028Zinc, cadmium, lead, nickel, and cobalt in hydrochloric acid
Determination of Zn, Cd, Pb, Ni, and Co in hydrochloric acid (37.8%).
- AN-V-029Zinc, cadmium, lead, nickel, and cobalt in Javelle water
Determination of Zn, Cd, Pb, Ni, and Co in Javelle water.
- AN-V-030Zinc, cadmium, lead, nickel, and cobalt in iron(III) chloride solution (40%)
Determination of Zn, Cd, Pb, Ni, and Co in FeCl3 solution of 40%.
- AN-V-031Coumarin and tartrazine in vodka
Determination of coumarin and tartrazine in vodka.
- AN-V-032Zinc, cadmium, lead, copper, iron, nickel, and cobalt in freeze-dried hops
Determination of Zn, Cd, Pb, Cu, Ni, Co, and Fe in freeze-dried hops after a wet digestion.
- AN-V-033Zinc, lead, copper, and iron in sugar
Determination of Zn, Pb, Cu, and Fe in sugar after wet digestion.
- AN-V-035Zinc, cadmium, lead, and copper in chili sauce after UV digestion
Determination of Zn, Cd, Pb, and Cu in chili sauce after digestion UV.
- AN-V-036Mercury in chili sauce after UV digestion
Determination of Hg in chili sauce after UV digestion.
- AN-V-038Aluminum in albumin lyophilizate after digestion
Determination of aluminum with Eriochrome Blue Black R at 60 °C in albumin lyophilizate after a wet digestion.
- AN-V-039Zinc, cadmium, lead, and copper in whiskey after UV digestion
Determination of Zn, Cd, Pb, and Cu in whiskey after UV digestion.
- AN-V-041Cadmium, lead, copper, nickel, and cobalt in soybean oil after digestion
Determination of Cd, Pb, Cu, Ni, and Co in soybean oil after extraction by boiling with HCl under reflux.
- AN-V-043Zinc in a herbal pharmaceutical drug against prostate cancer
Determination of zinc in a herbal pharmaceutical drug against cancer of the prostate.
- AN-V-044Boron in human plasma using Beryllon III as a ligand
Voltammetric determination of boron in plasma using Beryllon III as a ligand [L. Thunus (1996), Anal. Chim. Acta 318: 303–308].
- AN-V-045電気化学測定装置による飲料水中に含まれるウランの測定
飲料水中のウランは、ハンギング水銀ドロップ電極 (HMDE) での吸着ストリッピング ボルタンメトリー (AdSV) によって測定できます。 クロラニル酸は、キレート試薬として使用されます。
- AN-V-046Zinc, cadmium, lead, copper, nickel, and cobalt in vitamin tablets
Determination (after digestion) of zinc, cadmium, lead, copper, nickel, and cobalt in fabrication powder of vitamin tablets.
- AN-V-047Manganese, iron, and molybdenum in vitamin tablets
Determination of manganese, iron, and molybdenum (after digestion) in fabrication powder of vitamin tablets.
- AN-V-048Clotiapine in a standard sample
Determination of clothiapine in a pharmaceutical standard.
- AN-V-051Cadmium and lead in a herbicide
Determination of cadmium and lead in herbicide powder containing 37% copper after digestion.
- AN-V-053Artemisinin and artesunate in a standard sample
Determination of artemisinin and artesunate in a standard.
- AN-V-054Palladium in pharmaceutical products
The concentration of Pd in pharmaceutical products is determined by polarography after wet digestion.
- AN-V-055ß-Propiolactone in vaccine
Determination of ß-propiolactone in vaccine.
- AN-V-056Ascorbic acid in vitamin capsules
Determination of ascorbic acid (vitamin C) in vitamin capsules after sample digestion.
- AN-V-057Thiomersal in eye drops
Thiomersal (also called thimerosal) is a mercury containing organic molecule that has been widely used as preservative for vaccines and eye drops. It is very effective, even in very low concentrations, against a wide range of microorganisms and viruses. To reduce the risk for consumers the maximum concentration of mercury in the products is limited by the authorities. Polarography or voltammetry can be used to accurately determine the concentration of thiomersal in vaccines or other cosmetic and pharmaceutical solutions (such as eye drops). The method is simple to perform, specific, and free of interferences.
- AN-V-058Cysteine and cystine in an infusion solution
Determination of cysteine and cystine in an infusion solution.
- AN-V-0591-Methyl-nicotinamide hydrochloride in a standard solution
Determination of 1-methyl-nicotinamide hydrochloride in a standard using Na2CO3 as electrolyte.
- AN-V-060Cysteine and cystine in caseinate
Determination of cysteine and cystine in caseinate after sample preparation with NaOH.
- AN-V-061Iron speciation in water with the Multi-Mode Electrode pro
Accurate determination of Fe(II) and Fe(III) in water is crucial for many industries. Cathodic sweeping voltammetry (CSV) offers a robust, cost-effective solution.
- AN-V-0624-Carboxybenzaldehyde in polyterephthalic acid
4-Carboxybenzaldehyde can be reduced directly on the DME in a solution containing ammonium.
- AN-V-063Cyanide in gases resulting from the incineration of plastic insulating materials
Polarographic determination of cyanide in gases resulting from the incineration of plastic insulation materials after sample preparation.
- AN-V-064Free styrene in polystyrene and mixed polymers
Determination of styrene monomers in polystyrene. Free styrene is converted to a polarographically active pseudonitrosite.
- AN-V-065Tungsten in the organic phase
Determination of W(VI) in the organic phase after digestion
- AN-V-068Cadmium and lead in seawater
Cd and Pb can be determined in seawater samples in the ng/L concentration range by anodic stripping voltammetry on a mercury film electrode (MFE).
- AN-V-069Nickel and cobalt in seawater
Nickel and cobalt can be determined in seawater by adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-070Determination of iodide in glacial acetic acid
Iodide contamination in glacial acetic acid poses risks for downstream processes. Cathodic stripping voltammetry (CSV) at the HMDE offers reliable iodide measurement.
- AN-V-071Rhodium and platinum in drinking water
Rhodium and platinum can be determined in water samples after UV digestion and complexation by adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-072NTA and EDTA in wastewater
NTA and EDTA can be determined as their bismuth complexes at the DME.
- AN-V-073Ascorbic acid in orange juice
Ascorbic acid (vitamin C) can be determined in fruit and vegetable juices at the DME without sample preparation.
- AN-V-074Riboflavin in vitamin tablets
Riboflavin (vitamin B2) can be determined in vitamin preparations at the DME.
- AN-V-075Nicotinamide in vitamin tablets
Nicotinamide (vitamin B3, vitamin PP) can be determined in vitamin preparations at the DME.
- AN-V-076金めっき液中のコバルト(Co)の濃度測定
コバルト(Co)は、5-スルホサリチル酸を支持電解液に、ジメチルグリオキシム(DMG)を錯化剤として用い、滴下水銀電極(DME)で高濃度の金(Au)の存在下で測定できます。
- AN-V-077Nickel and cobalt in zinc plant electrolytes (concentrated zinc sulfate solutions)
Nickel can be determined in concentrated zinc solutions by adsorptive stripping voltammetry (AdSV) at the HMDE using ammonia buffer as supporting electrolyte and dimethylglyoxime (DMG) as complexing agent. The determination of cobalt does not work under these conditions as the very high Zn2+ concentration interferes with the Co signal. Therefore, an alternative complexing agent has to be used: α-benzil dioxime in ammonia buffer under addition of sodium nitrite.
- AN-V-078ボルタンメトリー (VA) による亜鉛電解液中の全アンチモン(Sb)の測定
亜鉛製錬プラントの電解液中の全アンチモン(Sb)濃度は、5 mol/L の塩酸中でアノードストリッピングボルタンメトリー(ASV)により測定されます。 0.6 mol/L の塩酸を使用した場合には、アンチモン(III)の濃度のみが選択的に定量できます。 過剰に存在する銅(Cu)による妨害は、銅を選択的に酸化することによって抑制されます。 それにもかかわらず、試料中の銅濃度は、定量に使用できる試料量の上限を制限します。
- AN-V-079めっき液中のゲルマニウム(Ge)の濃度測定
ゲルマニウム(Ge)は、支持電解液として酢酸バッファー、錯化剤としてカテコールを用い、HMDEで吸着 ストリッピング ボルタンメトリー(AdSV)により測定することができます。
- AN-V-080Germanium in lead
Germanium can be determined by adsorptive stripping voltammetry (AdSV) at the HMDE using acetate buffer as supporting electrolyte and catechol as complexing agent.
- AN-V-081Copper, iron, and vanadium in sodium chloride
Copper, iron, and vanadium can be determined in salt samples in the µg/kg concentration range by adsorptive stripping voltammetry (AdSV) at the HMDE. No sample preparation is necessary.
- AN-V-082Different chromium species in sea water
Cr(III) forms an electrochemically active complex with diethylenetriaminepentaacetic acid (DTPA), so does Cr(VI) after in situ reduction on the surface of the HMDE. Depending on the sample preparation procedure and the waiting time after the addition of the complexing agent, the different chromium species can be differentiated:Total active chromium [total concentration of Cr(VI) and free Cr(III)]:The measurement is carried out immediately after the addition of DTPA.; Cr(VI): Between the addition of DTPA and the start of the analysis a minimum waiting time of 30 min is necessary. During this waiting time the Cr(III)-DTPA complex becomes electrochemically inactive.; Cr(III): The difference between the total active Cr and Cr(VI).; Totalchromium: Determination of total active Cr after UV digestion.;
- AN-V-083Zinc, cadmium, lead, and copper in wastewater after UV digestion
Zinc, cadmium, lead, and copper can be determined in wastewater samples after UV digestion by anodic stripping voltammetry (ASV) according to DIN 38406 part 16.
- AN-V-084Total chromium in wastewater after UV digestion (DTPA method)
Total chromium can be determined in wastewater samples. UV digestion is necessary to remove interfering organic matter before the analysis. Complete oxidation of Cr(III) to Cr(VI) is guaranteed by an additional UV irradiation step at pH > 4.
- AN-V-085Elemental sulfur in gasoline
The concentration of elemental sulfur in gasoline is determined by polarography in acetate containing toluene/methanol electrolyte. The determination is linear up to 2 mg/L with respect to the concentration of elemental sulfur in the measuring vessel. Organic sulfur compounds are not detected with this method. The method is not suitable for diesel fuel, because diesel is not completely soluble in the electrolyte used. The gas wash bottle (6.2405.030) for inert gas supply has to be filled with supporting electrolyte.
- AN-V-086Cadmium, lead, and copper in drinking water
Cd, Pb, and Cu can be determined in one run in acetate buffer by anodic stripping voltammetry (ASV).
- AN-V-087Nickel and cobalt in drinking water
Nickel and cobalt can be determined in drinking water in one run by adsorptive stripping voltammetry (AdSV). Dimethylglyoxime (DMG) is used as complexing agent at a pH value of 9.3.
- AN-V-089Mercury in wastewater
Mercury can be determined in wastewater by anodic stripping voltammetry (ASV) on a gold rotating disk electrode (Au RDE). After the addition of hydrochloric acid and hydrogen peroxide, digestion is done by UV irradiation.
- AN-V-090飲料水中のマンガンの測定
飲料水中のマンガン(Mn)は、HMDE の陽極ストリッピング ボルタンメトリー (ASV) によって測定できます。 測定はアルカリ溶液中で行われ、金属間化合物による干渉を防ぐために亜鉛溶液を添加します。
- AN-V-092Nickel in white wine after UV digestion
For the determination of nickel in white wine, UV digestion is required to mineralize the sample. The determination is done by adsorptive stripping voltammetry (AdSV) at the HMDE in ammonia buffer with dimethylglyoxime (DMG).
- AN-V-093Zinc, cadmium, lead, and copper in red wine after UV digestion
Zinc, cadmium, lead, and copper can be determined in red wine after UV digestion by anodic stripping voltammetry (ASV).
- AN-V-094Platinum and rhodium in red wine after UV digestion
For the determination of heavy metals in wine, UV digestion is required to mineralize the sample. The determination of platinum and rhodium is carried out with adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-095Quinine in bitter lemon
Quinine can be determined by polarography at the DME using Britton-Robinson buffer at pH = 7.0 as supporting electrolyte.
- AN-V-096Platinum in urine after UV digestion
Platinum in urine can be determined by adsorptive stripping voltammetry (AdSV) after UV digestion of the sample.
- AN-V-097Chromium in sulfuric acid
Cr(VI) is determined with the complexant DTPA at pH 6.2 by adsorptive stripping voltammetry (AdSV) at the HMDE.
- AN-V-098Molybdenum in sulfuric acid
Mo is determined by polarography at the SMDE in nitric acid solution.
- AN-V-099Cadmium, lead, and copper in triphosphate
Cadmium, lead, and copper are determined by anodic stripping voltammetry (ASV) at the HMDE using aqueous nitric acid as supporting electrolyte.
- AN-V-100Nickel and cobalt in triphosphate
Ni and Co are determined in triphosphate by adsorptive stripping voltammetry (AdSV) in ammonia buffer at pH 9.5 with addition of dimethylglyoxime (DMG).
- AN-V-102三リン酸塩に含まれるマンガンの測定
三リン酸塩(トリホスフェート)中のマンガンは、HMDE の陽極ストリッピング ボルタンメトリー (ASV) で測定できます。 サンプルは最初に分解させ、次にアルカリ溶液中で測定します。
- AN-V-103Chromium in lime (CaCO3)
Cr(VI) is determined at the HMDE in an electrolyte containing ethylenediamine and acetate. Because Cr(III) is electrochemically inactive, all Cr has to be oxidised prior to analysis.
- AN-V-104Formaldehyde in metalworking lubricants
Formaldehyde is determined polarographically at the DME in alkaline solution.
- AN-V-105Thallium in the presence of an excess of cadmium in zinc plant electrolytes (concentrated ZnSO4 solutions)
Thallium and cadmium can be determined by anodic stripping voltammetry (ASV) at the HMDE (Tl) and polarography at the DME (Cd), respectively using aqueous hydrochloric acid as supporting electrolyte. Since Cd is present in high excess and would therefore interfere with the determination of thallium, a post electrolysis procedure is applied to remove the co-deposited metal from the mercury drop.
- AN-V-106Nickel and cobalt in wastewater after UV digestion
Determination of nickel and cobalt in wastewater samples through adsorptive Stripping Voltammetry (AdSV). The wastewater samples first undergo a UV digestion in accordance with DIN 38406 Part 16.
- AN-V-107ボルタンメトリー (VA)によるUV分解後の排水に含まれるスズ (TI) の測定
排水に含まれるスズ(TI)は、メチレンブルーを添加した後、シュウ酸緩衝液中でのアノードストリッピングボルタンメトリー(ASV)により定量できます。有機物を含む試料は、分析前にUV分解処理を行う必要があります。金属濃度が高い場合は、分解前に希釈してから測定を行います。
- AN-V-108Thallium in wastewater after UV digestion
Thallium in wastewater is determined in acetate buffer in presence of EDTA by anodic stripping voltammetry (ASV). Samples with organic substances have to undergo UV digestion before analysis.
- AN-V-109Selenium in wastewater after UV digestion
Selenium is determined by cathodic stripping voltammetry (CSV) at the hanging mercury drop electrode (HMDE). Se(IV) is deposited on the surface of the mercury drop in sulfuric acid electrolyte under addition of copper ions as Cu xSe y.Wastewater samples containing organic contaminants have to be digested by UV irradiation before analysis. In addition, the sample has to undergo a second irradiation step at pH 7−9 to reduce Se(VI) to Se(IV), since only Se(IV) is electrochemically active.
- AN-V-110Total chromium in wastewater after UV digestion (polarography method with ethylene diamine)
Cr(VI) is determined by polarography at the SMDE in acetate solution containing ethylene diamine to mask interfering copper ions.Only Cr(VI) is electrochemically active. It is for that reason that all chromium compounds must be present before the analysis as CR(VI), which is guaranteed by UV radiation with a pH > 4.