検索
プロダクトファミリー
プロダクトファミリー (73)製品モデル
製品モデル (716)アプリケーション
アプリケーション (2243)専門家によるトレーニングとウェビナー
イベント (2)電極
電極 (529)カラム
カラム (163)Accessories
スペアーパーツ (2308)ソフトウェア
ソフトウェア (355)取扱説明書&カタログ
文献 (2482)注目の技術情報
技術情報 (189)ニュース
ニュース (83)その他のコンテンツ
お問い合わせ (231)Industries
Industries (64)他にない保守&修理
Support & service (92)オンデマンド ウェビナー
ウェビナー (74)2.772.0020
Pump Unit 772 "Aspiration"Peristaltic pump for the aspiration of titrated solution and suspensions. The "Aspiration" version contains extensive accessories for aspiration. The pump can be actuated through a Relay Box 731. It is suitable for the conveyance of solvents.
2.772.0030
Pump Unit 772 "Rinse"Peristaltic pump for rinsing sample beakers and electrodes. The "Rinse" version contains extensive accessories for rinsing. The pump can be actuated through a Relay Box 731. It is suitable for the conveyance of solvents.
2.772.0110
772 Pump UnitPeristaltic pump for direct connection to Sample Processors.
2.772.0120
772 Pump Unit – aspiratePeristaltic pump for direct connection to Sample Processors. The "Aspiration" version contains extensive accessories for the aspiration of titered-out solutions.
2.772.0130
772 Pump Unit – rinsePeristaltic pump for direct connection to Sample Processors. The "Rinse" version contains extensive accessories for rinsing.
2.778.0010
778 Sample Processor (1 pump)Sample Processor with one work station and one pump for the automatic processing of small to medium numbers of routine samples in combination with Titrinos or pH/ion meters. Compact system thanks to built-in pump for rinsing the titration vessel. A peristaltic or membrane pump can be connected to the Sample Processor for aspirating off the titrated solution (optional). Direct connection and control of stirrers and Dosinos via MSB. Control takes place via a Controller or the tiamo PC software.
2.778.0020
778 Sample Processor (2 pumps)Sample Processor with one workstation and 2 pumps for the automatic processing of small to medium numbers of routine samples in combination with Titrinos or pH/ion meters. Compact system thanks to built-in pump for rinsing the titration vessel. A peristaltic or membrane pump can be connected to the Sample Processor for aspirating off the titrated solution (optional). Direct connection and control of stirrers and Dosinos via MSB. Control takes place via a Controller or the tiamo PC software.
2.778.0030
778 Sample ProcessorSample Processor with one work station and two pump connections for the automatic processing of small to medium numbers of routine samples in combination with Titrinos or pH/ion meters. Compact system thanks to built-in pump for rinsing the titration vessel. A peristaltic or membrane pump can be connected to the Sample Processor for aspirating off the titrated solution (optional). Direct connection and control of stirrers and Dosinos via MSB. Control takes place via a Controller or the tiamo PC software.
2.786.0010
786 Swing Head with transfer head leftAdditional equipment for Robotic Sample Processors XL for transferring / pipetting from small sample vessels into larger titration vessels on the rack or into an external titration cell; this can be located to the left of the work station.
2.786.0020
786 Swing Head with transfer head rightAdditional equipment for Robotic Sample Processors XL for transferring / pipetting from small sample vessels into larger titration vessels on the rack or into an external titration cell; this can be located to the right of the work station.
2.786.0030
786 Swing Head with titration swing arm, left- or right-swingingAdditional equipment for Robotic Sample Processors XL for direct titration in sample vessels of 75 mL and more.
2.786.0040
786 Swing HeadAdditional equipment for Robotic Sample Processors XL without titration or transfer heads.
2.786.0240
786 Swing Head, right-swinging, reinforcedStrengthened Swing Head for usage with Sample Processors.
2.791.0010
791 IC VA DetectorD
2.791.0020
791 VA DetectorAmperometric Detector for Ion Chromatography.Electrochemical (amperometric) detection with the 791 VA Detector is a very sensitive detection method used successfully in both HPLC and ion chromatography. This method is also characterized by its very high selectivity: Only easily oxidizable or reducible substances are detected - chloride or sulfate are not detected and do not interfere with the electrochemical determination, even in high concentrations.The detector can be used in series or in parallel with other detectors that are frequently used in IC or HPLC (e.g. conductivity or UV/VIS detectors).Numerous electrodes suitable for each amperometric application are available.
2.797.0010
797 VA Computrace トレース分析797VAコンピュートレース は、USBポートを経てパソコンに接続する最新の電気化学分析装置です。同梱のPCソフトウェアは測定を制御し、測定データを記録し、それを分析します。全体の構成が把握しやすいプログラムにより、操作がこの上なく容易です。内蔵されたガルバノスタット付きポテンショスタットにより、低減されたノイズにおける最高の感度を保証します。トレース分析および教育用のボルタンメトリーシステム。完全な測定システムのためのVAコンピュートレースソフトウェアおよび全ての電極を含む付属品一式: マルチ・モード電極プロ (Multi-Mode-Electrode, MME pro)、Ag/AgCl参照電極、白金補助電極。
2.797.0020
797 VA Computrace797VAコンピュートレース は、USBポートを経てパソコンに接続する最新の電気化学分析装置です。同梱のコンピューターソフトウェアは測定を制御し、測定データを記録し分析します。全体の構成が把握しやすいプログラムにより、操作が大変容易です。内蔵されたガルバノスタット付きポテンショスタットにより、低減されたノイズにおける最高の感度を保証します。トレース分析、CVS(サイクリックボルタンメトリックストリッピング)付き電気めっき浴内の有機添加物の測定、教育用のボルタンメトリーシステム。少数の付属品、電極なし
2.797.0030
797 VA Computrace CVS仕様797VAコンピュートレース は、USBポートを経てPCに接続する最新の電気化学分析装置です。同梱のPCソフトウェアは測定を制御し、測定データを記録し、それを分析します。全体の構成が把握しやすいプログラムにより、操作がこの上なく容易です。内蔵されたガルバノスタット付きポテンショスタットにより、低減されたノイズにおける最高の感度を保証します。CVS(サイクリックボルタンメトリックストリッピング)付き電気めっき浴内の有機添加物の測定のためのボルタンメトリーシステム。完全な測定システムのためのVAコンピュートレースソフトウェアおよび全ての電極を含む付属品一式: 白金回転ディスク電極 (RDE)、Ag/AgCl参照電極、白金補助電極。
2.797.3010
Power Pack Heavy Metals (Manual)Our basic package for the determination of the concentration of the critical heavy metals in all types of water-vapor circulation in thermal power generating stations by means of voltammetry. The system, comprised of a 797 VA Computrace and two 800 Dosinos, performs the determination of a single sample completely automatically. After preparing the sample manually, auxiliary solution and standard solution are added for calibration without user intervention with the aid of two dosing systems of the 800 Dosino type.
2.797.3110
Power Pack Heavy Metals (Automated)The ideal solution for the completely automated determination of the concentration of the critical heavy metals in all types of water-vapor circulation in thermal power generating stations by means of voltammetry in small sample series. The 797 VA Computrace in combination with the 863 Compact VA Autosampler permits the automatic processing of up to 18 samples. The addition of auxiliary and standard solutions for calibration is accomplished with the aid of three dosing systems of the 800 Dosino type. An 843 Pump Station ensures carry-over-free analysis results, thanks to which the measuring vessel is rinsed after each sample. The system is the optimum solution for water samples in which one or two analytes are to be determined.Our promotion offer for orders placed by June 30, 2014: During the promotion period, Metrohm will give you an 800 Dosino for free, which makes the addition of auxiliary or standard solutions even more flexible, as well as an 827 pH Lab for measuring the pH value in your sample or for setting the pH value of the measurement solution as needed.
2.800.0010
800 Dosino800 Dosino 高機能電動ビュレットのドージングユニット用書き込み・読み取り用ハードウェア付き駆動部。固定されたケーブル付き (長さ150 cm)。
2.800.0020
800 Dosino高機能電動ビュレットのドージングユニット用書き込み・読み取り用ハードウェア付き駆動部。固定されたケーブル付き (長さ 0.65 m)。
2.801.0010
801 StirrerMagnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus).
2.801.0040
801 Stirrer with standMagnetic stirrer including base plate, support rod and electrode holder for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimat and 780/781 pH meters as well as the 856 and 867 measuring modules. With permanently attached cable for MSB (Metrohm Serial Bus).
2.802.0010
727 Ti Stand 用 802 Stirrer個別のスピードコントローラ 6.2137.000 とプロペラスターラ 6.1909.010 を備えるロッドスターラ。
2.802.0011
802 Stirrer、110 V US110 V 用電源装置、US プラグ、スイッチングリングとスピードコントローラ付きロッドスターラ。
2.802.0014
802 Stirrer、220 V EU727 Titration Stand 用ロッドスターラ。220 V 用電源装置、EU プラグ、スイッチングリングとスピードコントローラ付きロッドスターラ。
2.802.0020
サンプルチェンジャー用 802 Stirrerサンプルチェンジャーおよび Sample Processor 用ロッドスターラ。6.1909.020 プロペラスターラ 104 mm と固定取付けされたケーブル付き。
2.802.0040
804 Ti Stand 用 802 Stirrerプロペラスターラ 6.1909.010 を備えるロッドスターラ。
2.803.0010
803 TI Stand with stirrer and pumpCompact titration stand with magnetic stirrer and built-in pump for solvent addition and aspiration of the titration vessel contents. Suitable for Karl Fischer titrations with Titrandos. MSB connection.Including comprehensive accessories, solvent bottle and waste bottle.
2.804.0010
804 Ti Stand without stand rodTitration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
2.804.0040
804 Ti Stand with standTitration stand and controller for 802 Rod Stirrer. The 804 Ti Stand together with the optional 802 Rod Stirrer provides an alternative to the magnetic stirrer. Ti Stand with base plate, support rod and electrode holder.
2.805.0010
805 DosimatDosing device for the Titrando and Sample Processors with read/write hardware for intelligent Exchange Units. With permanently attached cable. Without Exchange Unit.
2.810.0010
810 Sample Processor916 Ti-Touch または 915 KF Ti-Touch を用いたルーチンサンプルの自動分析のためのサンプルプロセッサー。少量から中量までの、連続した、カール フィッシャー滴定などの電位差滴定の自動処理のための、ワークステーションおよび内蔵式ダイヤフラムポンプ付きサンプルプロセッサー。内蔵式ポンプの他に、もう一つのポンプ(ダイヤフラムポンプもしくはペリスタリックポンプ)とリキッドハンドリングの作業のためのドージングデバイスを3つまで接続することができます。様々な用途に対応するため、ラック、スターラー、滴定ヘッド、スイングヘッド、サンプル容器などはアプリケーションに合わせて別途ご注文ください。
2.811.0024
811 Online IC Process Analyzer (2 チャンネル、230 V)サプレッションありおよびなし、超微量域までの陽イオンおよび陰イオンの同時測定のための、インラインキャリブレーションと濃縮を備えた 2 チャンネルオンラインイオンクロマトグラフ。独立した 10 のサンプルフロー。230 V。
2.813.0020
813 VA Compact AutosamplerAutosampler for the basic automation of the VA systems, with integrated peristaltic pump for sample transfer. The sample changer can be used in combination with the 746 VA Trace Analyzer or the 797 VA Computrace. Capacity: 18 samples.
2.814.0010
814 USB Sample Processor (1T/1P)小検体数から中検体数までのルーチンサンプルの連続自動処理のためのワークステーションおよび内蔵式ダイヤフラム ポンプ付きUSBサンプル・プロセッサー。LQH(リキッドハンドリング)作業のため、内蔵式ポンプの他に、ポンプをさらに1つ(ダイヤフラムポンプもしくはペリスタリックポンプ)とドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.814.0020
814 USB Sample Processor (1T/2P)小検体数から中検体数までのルーチンサンプルの連続自動処理のためのワークステーションおよび内蔵式ダイヤフラムポンプが2つ付いたUSBサンプルプロセッサー。LQH(リキッドハンドリング)作業のため、内蔵式ポンプの他に、ドージングデバイスを更に3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。 制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.814.0030
814 USB Sample Processor (1T/0P)少検体数から中検体数までのルーチンサンプルの連続自動処理のためのワークステーション付きUSBサンプルプロセッサー。LQH(リキッドハンドリング)作業のため、ポンプを2つまで(ダイヤフラムポンプもしくはペリスタリックポンプ)、ドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.814.0110
814 USB Sample Processor (2T/2P)少検体数から中検体数までのルーチンサンプルの連続自動処理のためのワークステーションが2つと内蔵式ダイヤフラム ポンプが2つ付いたUSBサンプルプロセッサー。LQH(リキッドハンドリング)作業のため、内蔵式のポンプの他に、ポンプを更に2つ(ダイヤフラムポンプもしくはペリスタリックポンプ)、ドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.814.0120
814 USB Sample Processor (2T/4P)少検体数から中検体数までのルーチンサンプルの連続自動処理のためのワークステーションが2つと内蔵式ダイヤフラム ポンプが4つ付いたUSBサンプルプロセッサー。LQH(リキッドハンドリング)作業のため、内蔵式ポンプの他に、ドージングデバイスを更に3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.814.0130
814 USB Sample Processor (2T/0P)少検体数から中検体数までのルーチンサンプルの連続自動処理のためのワークステーションが2つ付いたUSBサンプルプロセッサー。LQH(リキッドハンドリング)作業のため、ポンプを4つまで(ダイヤフラムポンプもしくはペリスタリックポンプ)、ドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.815.0010
815 Robotic USB Sample Processor XL (1T/1P)検体数が多量なルーチンサンプルの連続自動処理、複雑なサンプル前処理、並行作業のためのワークステーション1つおよび内蔵式ダイヤフラム ポンプが付いたロボテックUSBサンプルプロセッサーXL。LQH(リキッドハンドリング)作業のため、内蔵式ポンプの他に、ポンプをさらに1つ(ダイヤフラムポンプもしくはペリスタリックポンプ)、ドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、スイングアーム、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.815.0020
815 Robotic USB Sample Processor XL (1T/2P)検体数が多量なルーチンサンプルの連続自動処理、複雑なサンプル前処理、並行作業のためのワークステーション1つおよび内蔵式ダイヤフラムポンプが2つ付いたロボテックUSBサンプルプロセッサーXL。LQH(リキッドハンドリング)作業のためのドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、スイングアーム、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.815.0030
815 Robotic USB Sample Processor XL (1T/0P)検体数が多量なルーチンサンプルの連続自動処理、複雑なサンプル前処理、並行作業のためのワークステーション1つが付いたロボテックUSBサンプルプロセッサーXL。LQH(リキッドハンドリング)作業のため、ポンプを2つまで(ダイヤフラムポンプもしくはペリスタリックポンプ)、ドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、スイングアーム、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.815.0110
815 Robotic USB Sample Processor XL (2T/2P)検体数が多量なルーチンサンプルの連続自動処理、複雑なサンプル前処理、並行作業のためのワークステーションが2つと内蔵式ダイヤフラム ポンプが2つ付いたロボテックUSBサンプルプロセッサーXL。LQH(リキッドハンドリング)作業のため、内蔵式ポンプの他に、ポンプを更に2つまで(ダイヤフラムポンプもしくはペリスタリックポンプ)、ドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、スイングアーム、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNIS。
2.815.0120
815 Robotic USB Sample Processor XL (2T/4P)多量のルーチンサンプルの連続自動処理、複雑なサンプル前処理、並行作業のためのワークステーションが2つと内蔵式ダイヤフラムポンプが4つ付いたロボテックUSBサンプルプロセッサーXL。LQH(リキッドハンドリング)作業のためのドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、スイングアーム、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNISソフトウェア。
2.815.0130
815 Robotic USB Sample Processor XL (2T/0P)多量のルーチンサンプルの連続自動処理、複雑なサンプル前処理、並行作業のためのロボテックUSBサンプルプロセッサーXL。LQH(リキッドハンドリング)作業のため、ポンプを4つまで (ダイヤフラムポンプもしくはペリスタリックポンプ)、ドージングデバイスを3つまで接続することができます。様々な用途に対応するため、サンプルラック、スターラー、滴定ヘッド、スイングアーム、Swing Head、サンプル容器はアプリケーションに合わせて別途ご注文ください。制御はTouch Controlにより「スタンドアローン」で動作します。PC制御には以下のソフトウェア製品を選択することができます: 滴定ソフトウェアtiamo™、クロマトグラフィーソフトウェアMagIC Net、ボルタンメトリーソフトウェアviva、またはOMNISソフトウェア。
2.815.1110
815 Robotic Titration Soliprep815 Robotic Titrationは、滴定前に粉砕が必要な固体サンプルの完全自動前処理のためのシステムです。以下のもので構成されます:1 x 815 Robotic USB Sample Processor XL1 x 136 Polytron 電源装置付き2 x 772 Pump Unit2 x 786 Swing Head1 x 802 Rod stirrer
2.815.2110
815 Robotic Flexible Soliprep粉砕、ろ過、密閉式バイアルに充填する固体サンプル用自動前処理システム。以下のもので構成されます:1 x 815 Robotic USB Sample Processor XL1 x 136 Polytron 電源装置付き1 x 772 Pump Unit1 x 786 Swing Head1 x 786 Swing Head 強化型1 x 800 Dosino
2.815.3110
815 Robotic Filtration Soliprep815 Robotic Filtration Soliprep は、測定前に粉砕およびろ過が必要なサンプルの完全自動前処理のための完全なシステムです。以下のもので構成されます:1 x 815 Robotic USB Sample Processor XL1 x 136 Polytron 電源装置付き1 x 772 Pump Unit1 x 786 Swing Head1 x 786 Swing Head 強化型1 x 800 Dosino
2.815.4110
815 Robotic Soliprep for LC815ロボテックソリップレップLC用は、測定前に溶解、粉砕、希釈、濾過のいずれかを行わなければならないサンプルを完全自動で前処理を行う総合システムです。前処理の後、サンプルはクロマトグラフのインジェクターに直接転送されます。これは以下のもので構成されます。:1 x 815 ロボテック USB サンプルプロセッサ XL1 x 136 ポリトロン電源装置付き1 x 772 ポンプユニット2 x 786 スイングヘッド2 x 800 ドジーノ電動ビュレット
2.819.0110
819 Advanced IC Detector (PEEK)Top-class conductivity detector for measurements with and without chemical suppression. Temperature-stability better than 0.01 °C. Shielded by Faraday cage. Wet part and electronics clearly separated. Electronic suppression. PEEK version.
2.823.0010
823 Membrane Pump UnitMembrane pump for direct connection to Sample Processors.
2.823.0020
823 Membrane Pump Unit «aspirate»Membrane pump for direct connection to Sample Processors. The «Aspiration» version contains numerous accessories for aspirating off solutions.
2.823.0030
823 Membrane Pump Unit «rinse»Membrane pump for direct connection to Sample Processors. The «Rinsing» version contains numerous rinsing accessories.
2.824.0020
824 Easy Sample ChangerThe economic sample changer for routine use.Easy Sample Changer Micro: sample changer for titrations with smaller sample volumes. Up to 24 samples with a maximum volume of 75 mL can be processed in a single run. With the KFT equipment the Easy Sample Changer can be converted to a Karl Fischer sample changer.
2.826.0010
826 pH mobilePortable pH meter with IrDa interface, including carrying strap and batteries.
2.826.0020
826 pH mobile with PrimatrodePortable pH meter with IrDa interface, including carrying strap, batteries and 6.0228.020 Primatrode with NTC (IP67).
2.826.0110
826 pH mobile with carrying casePortable pH meter with IrDa interface. With carrying case, ample accessories for calibration, including 6.0228.020 Primatrode.
2.827.0014
pH Lab Irda 230 V EU2.827.0015
pH Lab Irda 120 V US2.827.0017
pH Lab Irda 240 V AUS2.827.0019
pH Lab Irda 230 V UK2.827.0114
827 pH lab; 230 V, EU with PrimatrodeLaboratory pH meter with IrDa interface and 6.0228.010 Primatrode
2.827.0115
827 pH lab; 120 V, US with PrimatrodeLaboratory pH meter with IrDa interface and 6.0228.010 Primatrode
2.827.0117
827 pH lab; 240 V, AUS with PrimatrodeLaboratory pH meter with IrDa interface and 6.0228.010 Primatrode
2.827.0119
827 pH lab; 230 V, UK with PrimatrodeLaboratory pH meter with IrDa interface and 6.0228.010 Primatrode
2.827.0214
827 pH lab; 230 V, EU with UnitrodeLaboratory pH meter with IrDa interface and 6.0258.600 Unitrode
2.827.0215
827 pH lab; 120 V, US with UnitrodeLaboratory pH meter with IrDa interface and 6.0258.600 Unitrode
2.827.0217
827 pH lab; 240 V, AUS with UnitrodeLaboratory pH meter with IrDa interface and 6.0258.600 Unitrode
2.827.0219
827 pH lab; 230 V, UK with UnitrodeLaboratory pH meter with IrDa interface and 6.0258.600 Unitrode
2.831.0010
831 KF Coulometer (2 液型電極付き)低価格なクーロメーターと、トレースレベルまでの水分測定のための2液型電極付きの発生電極が付いた滴定セル。高い信頼性、バックライト付きのグラフィック表示可能なディスプレイ、多言語対応のダイアログ、容易な操作性により、このクーロメーターは多くのラボにおいて欠かせない存在となっています。鮮明なディスプレイは重要な滴定パラメータを表示し、時間に対する水のµg数をカーブで表して、滴定の過程を明確に伝えます。推奨測定範囲: 水の絶対量 10 µg~200 mg
2.831.0110
831 KF Coulometer (1液型電極付き)低価格なクーロメーターと、トレースレベルまでの水分測定のための1液型電極付きの発生電極が付いた滴定セル。高い信頼性、バックライト付きのグラフィック表示可能なディスプレイ、多言語対応のダイアログ、容易な操作性により、このクーロメーターは多くのラボにおいて欠かせない存在となっています。鮮明なディスプレイは重要な滴定パラメータを表示し、時間に対する水のµg数をカーブで表して、滴定の過程を明確に伝えます。推奨測定範囲: 水の絶対量 10 µg~200 mg
2.831.2010
831 KF Coulometer および 860 KF Thermoprepこの滴定システムは、831 Coulometer (2液型電極付き) および 860 KF Thermoprep で構成されています。これによって直接のカールフィッシャー滴定に不適切なサンプルを分析することができます。ぴったりと気密されたサンプルバイアルびんを使用してサンプルを860 KF Thermoprep のオーブンに入れます。サンプルが加熱され、含まれている水が蒸発し、滴定セルに送られます。それから 831 Coulometer により、サンプルの水分が測定されます。
2.831.2110
831 KF Coulometer および 860 KF Thermoprepこの滴定システムは、831 Coulometerおよび 860 KF Thermoprep で構成されています。これによって直接のカールフィッシャー滴定に不適切なサンプルを分析することができます。ぴったりと気密されたサンプルバイアルびんを使用してサンプルを 860 KF Thermoprep のオーブンに入れます。サンプルが加熱され、含まれている水が蒸発し、滴定セルに送られます。それから 831 Coulometer により、サンプルの水分が測定されます。
2.833.0020
833 Advanced IC Liquid Handling Suppressor UnitChemical «packed bed anion suppressor. Patented MSM Metrohm Suppressor Module as stand-alone instrument or for retrofitting HPLC or IC systems. Solvent- and pressure-resistant. With two-channel pump for regeneration and rinsing solution.
2.833.0030
833 Advanced IC Liquid Handling Sample Preparation UnitMetrohm inline sample preparation for the analysis of anions. Optimal for inline neutralization of strong bases. Cation exchanger for universal use. Unlimited capacity thanks to offline regeneration and rinsing.
2.833.0040
833 Advanced IC Liquid Handling Dialysis UnitDialysis sample preparation module for the determination of anions and cations in difficult matrices such as milk, fruit juice, emulsions, suspensions, etc. Including 2-channel peristaltic pump. Cellulose acetate membrane 0.25 µm.
2.833.0050
833 IC Liquid Handling Ultra Filtration UnitFor inline ultrafiltration. Guarantees the reliable removal of particles from the sample. 2-channel peristaltic pump and separate ultrafiltration cell, for example for installation in the 820 IC Separation Center.
2.838.0010
838 Advanced IC Sample ProcessorAdvanced IC Sample Processor in the basic version.
2.838.0020
838 Advanced IC Injection Sample ProcessorAdvanced IC Sample Processor with six-way injector for applications that require an additional injector.
2.838.0110
838 Advanced IC Dialysis Sample ProcessorAdvanced IC Sample Processor for inline dialysis.
2.838.0120
838 Advanced IC Dilution Sample ProcessorAdvanced IC Dilution Sample Processor for inline sample dilution.
2.838.0210
838 Advanced IC Ultrafiltration Sample ProcessorAdvanced IC Sample Processor for inline ultrafiltration.
2.838.0310
838 Advanced VA Sample Processor838アドバンスドVAサンプルプロセッサは、CVS(サイクリックボルタンメトリックストリッピング)を797 VAコンピュートレースと共に使用して電気めっき浴内の有機添加物を完全自動で測定するためのサンプルチェンジャーです。ブライトナーまたはサプレッサーのシリーズは、監視無しで連続で分析することができます。同梱のサンプルラックには、最高11 mLもしくは最高50 mLのサンプルが56個まで入ります。838 アドバンスドVAサンプルプロセッサ には、ユーザーの需要に応じて分析の手順を調整できる柔軟性の高いメソッドエディタが装備されています。個別のキーボードにより、メソッドエディタおよびその他のあらゆる機器設定へのアクセスが可能となっています。サンプルシリーズを測定する間、838 アドバンスドVAサンプルプロセッサ は797 VAコンピュートレース によって遠隔制御されます。機器は付属品、サンプルラック、キーボード、ワークプレイス全体の組立のための付属品も含めて納品されますが、洗浄機器は含まれません。
2.843.0020
843 Pump Station (membrane)The 843 Pump Station (membrane) has two built-in membrane pumps. These can be controlled directly via the interface using remote signals or manually by pressing a button.
2.843.0030
843 Pump Station (membrane) - rinse/aspirate for Compact Sample ChangerThe 843 Pump Station (membrane) has two built-in membrane pumps. These can be controlled directly from the 869 Compact Sample Changer via remote signals. The Rinse / Aspirate version is provided with all the accessories needed for automatically emptying the titration beaker and rinsing the titration equipment. The accessories is defined for usage with the 869 Compact Sample Changer.
2.843.0040
843 VA Membrane Pump Station コンパクトVAシステム843ダイヤフラムポンプステーション には、リモート信号を介して797 VAコンピュートレース によって直接制御できる内蔵式ダイヤフラムポンプが2つ装備されています。このポンプは、797 VAコンピュートレースを接続した一部自動および完全自動のVAおよびCVSシステムの測定容器の洗浄および排出を自動で行います。電圧電流法のバージョンでは、測定容器の自動洗浄および自動排出のための付属品が完全装備されています。
2.843.0050
843 Pump Station (membrane) - rinse/aspirate for Sample ProcessorsThe 843 Pump Station (membrane) has two built-in membrane pumps. These can be controlled directly from the Sample Processor via pump commands. The Rinse / Aspirate version is provided with all the accessories needed for automatically emptying the titration beaker and rinsing the titration equipment. The accessories are intended for use with the 814 and 815 Sample Processors.
2.843.0120
843 Pump Station (peristaltic)The 843 Pump Station (peristaltic) has two built-in peristaltic pumps. These can be controlled directly via the interface using remote signals or manually by pressing a button.
2.843.0130
843 Pump Station (peristaltic) - rinse/aspirate for Compact Sample ChangerThe 843 Pump Station (peristaltic) has two built-in peristaltic pumps. These can be controlled directly from the 869 Compact Sample Changer via remote signals. The Rinse / Aspirate version is provided with all the accessories needed for automatically emptying the titration beaker and rinsing the titration equipment. The accessories are defined for usage with the 869 Compact Sample Changer.
2.843.0140
843 VA Peristaltic Pump Station for Compact VA systemsThe 843 Peristaltic Pump Station has two built-in peristaltic pumps that can be controlled directly by the 797 VA Computrace via the remote signal. It is used for the automatic rinsing and emptying of the measuring vessel in partly automated and fully automated VA and CVS systems with the 797 VA Computrace.The version for voltammetry is equipped with the complete accessories for the automatic rinsing and emptying of the measuring vessel.
2.843.0150
843 Pump Station (peristaltic) - rinse/aspirate for Sample ProcessorsThe 843 Pump Station (peristaltic) has two built-in peristaltic pumps. These can be controlled directly from the Sample Processors via pump commands. The rinse/aspirate version is provided with all the accessories needed for automatically emptying the titration beaker and rinsing the titration equipment. The accessories are intended for use with the 814 and 815 Sample Processors.
2.843.0230
Professional VA/CVS システム用 843 Peristaltic Pump Station843 Peristaltic Pump Station は、半自動および完全自動の Professional VA/CVS システムの測定容器の洗浄および排出を自動で行います。これらには、リモート信号によって制御できる内蔵式ペリスタリックポンプが 2 つ装備されています。VA と CVS のバリエーションには、測定容器の自動洗浄と排出用の付属品一式があります。接続ケーブルは別途ご注文ください。
2.843.0240
Professionl VA/CVSシステム用843 Membrane Pump Station843 Membrane Pump Stationは、一部自動および完全自動のProfessional VA/CVSシステムの測定容器の洗浄および排出を自動で行います。これらには、リモート信号を介して制御できる内蔵式ダイヤフラムポンプが2つ装備されています。VAとCVSのバリエーションには、測定容器の自動洗浄と排出用の付属品一式があります。
2.845.0010
845 Eluent Synthesizer with one DosinoThe 845 Eluent Synthesizer eliminates the time-consuming manual preparation of the eluents and standards used in ion chromatography. The 845 Eluent Synthesizer facilitates work in research, analysis and quality assurance. Automation helps to reduce costs. It allows using one main component, for example ultrapure water, and four concentrates.
2.845.0020
845 Eluent Synthesizer with two DosinosThe 845 Eluent Synthesizer eliminates the time-consuming manual preparation of the eluents and standards used in ion chromatography. The 845 Eluent Synthesizer facilitates work in research, analysis and quality assurance. Automation helps to reduce costs. It allows using one main component, for example ultrapure water, and four concentrates.
2.846.0010
846 Dosing InterfaceドージングおよびLQH作業のために、最高4つまで800 Dosino または805 Dosimatが接続できるUSB接続可能な制御ユニット。操作にはTouch Control、またはOMNISソフトウェア、tiamo™、MagIC Net、viva、あるいは797 VA Computraceがインストールされたパソコンとの接続が必要です。
2.846.1010
Dosing PackageThe Dosing Package is the practical and proven solution for precise, reliable Liquid Handling in accordance with directives, both in regulated and non-regulated environments.You can rely on the Dosing Package for:standard applications such as dosing, diluting, aliquoting, pipetting; the manufacture of standard solutions from any given sample size; the manufacture of mixtures from various stock solutions;
2.847.0010
847 USB Lab Link847 USB Lab Link - rapid network connection for the Titrando (only for 840 Touch Control).
2.848.0010
848 Titrino plus以下の滴定を行うコンパクトな自動滴定装置 - 当量点を自動で検出するダイナミック滴定 (DET)- 当量点を自動で検出する等量滴下滴定 (MET)- 終点設定滴定 (SET)
2.848.0110
848 Titropackage plusCompact and inexpensive system for the automation of potentiometric determinations in the smallest possible space.The 848 Titropackage plus contains everything required to enable rapid installation and direct entry into working with the system. A large number of pre-defined titration methods, combined with very simple operation, permits immediate use. The system is comprised of 848 Titrino plus, 869 Compact Sample Changer, 802 Stirrer (propeller stirrer), the Ecotrode Plus and additional accessories.
2.848.0120
Titropackage plus with printerCompact and economic system for automating potentiometric determinations on a minimum footprint. Includes the following instruments:1 x 848 Titrino plus1 x 802 Rod stirrer1 x 869 Compact Sample Changer1 x USB Thermodrucker NEO's
2.848.1010
Food/Beverage Titrino plus食品/飲料水向けティトリーノプラス は、食品、飲料水、ワインにおける一般的な分析を行うための完璧なパッケージをお客様に提供します。内容は、自動滴定装置、マグネチックスターラー、電極、電解液、水溶性酸/塩基の滴定に最適なpHガラス電極のエコトロードプラス (Ecotrode Plus) の保存液が入ったオールインワン・パッケージとなっています。キャリブレーションのためのバッファーももちろん含まれます。メトロームの60年以上にわたるアプリケーション・ノウハウをご利用いただけます。ご信頼いただけるおよそ100のメソッドが、お客様のご利用をお待ちしています。自動滴定装置のプログラミングは不要です。メソッドは同梱のUSBメモリスティックから簡単にダウンロードすることができます。メソッドは、以下の刊行物を参照して作成されました。:- Official Methods of Analysis of the Association of Official Analytical Chemists (AOAC, USA)- U.S. Environmental Protection Agency (EPA)- Schweizerisches Lebensmittelbuch (「スイスの食品事典」)- Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung (「浄水、下水、汚泥調査におけるドイツの標準メソッド」)
2.848.1020
Food/Beverage Titrino plus プリンター付きFood/Beverage Titrino plus は、食料品分析における一般的な分析を行うための完璧なパッケージをお客様に提供します。内容は、細部にまで説明がついた100以上の測定メソッドに加え、滴定のための付属品一式となっています。USB 感熱式プリンター Q3X を含みます。
2.848.2010
Salt Titrino plus塩分測定向けティトリーノプラス は多様なサンプルにおける塩分測定のためのパッケージをお客様に提供します。内容は、細部にまで説明がついた測定メソッドに加え、滴定のための付属品一式となっています。パッケージには滴定装置、マグネチックスターラー、銀ティトロード(Ag-Titrode)、硝酸銀を含む沈殿滴定のためのメンテナンス不要の電極が含まれています。
2.848.2020
Salt Titrino plus プリンター付きSalt Titrino plus は多様なサンプルにおける塩化物の分析のための完璧なパッケージをお客様に提供します。内容は、細部にまで説明がついた測定メソッドに加え、滴定のための付属品一式となっています。USB 感熱式プリンター Q3X を含みます。
2.848.3010
Oil Titrino plus油分測定向けティトリーノプラス は、油製品の酸価と塩基価の測定のためのパッケージをお客様に提供します。内容は、細部にまで説明がついた測定メソッドに加え、滴定のための付属品一式となっています。パッケージには滴定装置、プロペラスターラー、ソルボトロード・イージークリーン (Solvotrode easyClean)、非水溶性滴定に特化したpHガラス電極が含まれています。
2.848.3020
Oil Titrino plus プリンター付きOil Titrino plus は、油製品の酸価と塩基価の測定のための完璧なパッケージをお客様に提供します。内容は、細部にまで説明がついた測定メソッドに加え、滴定のための付属品一式となっています。USB 感熱式プリンター Q3X を含みます。
2.849.0010
849 Level ControlAdditional equipment for Sample Processors for monitoring the filling level of rinsing or waste canisters via Remote. Prevents pumps from running dry and/or canisters from overflowing and is suitable for use with aqueous solutions, solvents and suspensions.
2.849.0020
849 Level Control metal-free (for canisters)Additional equipment for Metrohm instruments. For monitoring the filling level of bottles for eluent, auxiliary or waste solutions via remote control. The 849 Level Control prevents pumps from running dry and/or canisters from overflowing and is suitable for use with aqueous solutions, solvents and suspensions.The metal-free sensor works in solutions with very low conductivity. Therefore it may be used in ion chromatography.
2.849.0030
849 Level Control メタルフリー (ボトル用)自動で «Inline Eluent Preparation» を行うため、そしてリモートで溶離液ボトルまたは補助溶液ボトルの充填レベルをモニタリングするための追加装備。849 Level Control は、ポンプの空運転、またはオプションで入手可能な «FULL Sensor» により、オーバーフローを防止します。同梱の «EMPTY Sensor» は、水溶液や溶媒、懸濁液での使用に適しており、ロッドの長さは 2 L の溶離液ボトルを想定しています。 メタルフリーのセンサーは、電気伝導度が非常に低い溶液で使用できます。このため、イオンクロマトグラフィーでの使用、特に超純水での使用にも適しています。
2.850.9020
IC Conductivity Detector MBCompact and intelligent high performance conductivity detector for intelligent IC instruments. Optimized for microbore columns. Outstanding temperature stability, the complete signal processing within the protected detector block and the latest generation of DSP – Digital Signal Processing – guarantee the highest precision of the measurement. No change of measuring ranges (not even automatic ones) is required, due to the dynamic working range.Typical areas of application:Anion or cation determinations with chemical suppression, sequential suppression or without suppression and conductivity detection; Optimized for microbore (2 mm) applications, ideally suitable for coupling techniques (IC-MS or IC-ICP/MS); Specification at a glance:0–15000 μS/cm without range switching; Cell volume: 0.3 μL; Ring-shaped electrodes made of stainless steel X2CrNiMo17-12-2 (316 L), compatible with MSA; Maximum operating pressure: 10.0 MPa (100 bar); Cell temperature: 20–50 °C in increments of 5 °C; Temperature stability: 0.001 °C; Baseline noise: 0.2 nS/cm typical for sequential suppression; Capillaries: ID 0.18 mm; Supported with MagIC Net 4.1 and higher
2.851.0010
851 Titrando(2液型電極付き)クーロメーター(2液型電極、801 Stirrer付き)。トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。851 Titrandoにより、電量滴定を容易かつ迅速に行うことができます。推奨測定範囲: 水の絶対量10 µg~200 mgOMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています(必要な場合)
2.851.0020
851 Titrando(Touch Controlおよび2液型電極付き)クーロメーター(2液型電極、Touch Control、801 Stirrer付き)。トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。851 Titrandoにより、電量滴定を容易かつ迅速に行うことができます。推奨測定範囲: 水の絶対量10 µg~200 mgOMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています(必要な場合)
2.851.0110
851 Titrando(1液型電極付き)クーロメーター(1液型電極付き)。トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。851 Titrandoにより、電量滴定を容易かつ迅速に行うことができます。推奨測定範囲: 水の絶対量10 µg~200 mg。OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています (必要な場合)。
2.851.0120
851 Titrando(Touch Controlおよび1液型電極付き)クーロメーター(1液型電極付き、Touch Controlなし)。トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。851 Titrandoにより、電量滴定を容易かつ迅速に行うことができます。推奨測定範囲: 水の絶対量10 µg~200 mg。OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています(必要な場合)
2.852.0050
852 Titrando(2液型電極付き)クーロメーター(2液型電極、801 Stirrer、完全な容量滴定セル付き)。トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。クーロメトリーで推奨される測定範囲: 水の絶対量10 µg~200 mg852 Titrandoでは電量滴定の他に容量滴定によるカール フィッシャー滴定も可能です。OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています (必要な場合)。
2.852.0060
852 Titrando(Touch Controlおよび2液型電極付き)クーロメーター(2液型電極、Touch Control、801 Stirrer、完全な容量滴定セル付き)。トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。クーロメトリーで推奨される測定範囲: 水の絶対量10 µg~200 mg852 Titrandoでは電量滴定の他に容量滴定によるカール フィッシャー滴定も可能です。OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています (必要な場合)。
2.852.0150
852 Titrando(1液型電極付き)クーロメーター(1液型電極付き、完全な容量滴定セルなし)トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。クーロメトリーで推奨される測定範囲: 水の絶対量10 µg~200 mg。852 Titrandoでは電量滴定の他に容量滴定によるカール フィッシャー滴定も可能です。OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています (必要な場合)。
2.852.0160
852 Titrando(Touch Controlおよび1液型電極付き)クーロメーター(1液型電極付き、完全な容量滴定セルおよびTouch Controlセルなし)。トレースレベル (水の絶対量10 µg~10 mg) の水分測定において、クーロメトリーは液体、固体、気体中での水分測定に理想的なメソッドです。更にクーロメトリーは絶対メソッドなので、試薬ファクター測定の必要がありません。クーロメトリーで推奨される測定範囲: 水の絶対量10 µg~200 mg852 Titrandoでは電量滴定の他に容量滴定によるカール フィッシャー滴定も可能です。OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています (必要な場合)。
2.855.0010
855 Robotic Titrosampler «Basic» (1T/1P)個々のお客様の状況に応じた、滴定におけるオートメーションの拡張機能の基本モデル。内蔵式Titrando、Swing Headを含むワークステーション、内蔵式ダイヤフラム ポンプが装備された省スペース型のロボテックサンプルプロセッサーXL。滴定溶液の吸引のため、外付けチューブもしくはダイヤフラム ポンプを接続することができます (オプション)。メソッドのプログラミングは、使い勝手の良いTouch Control滴定ソフトウェア tiamo™ またはOMNISによって行われます。
2.855.0020
855 Robotic Titrosampler «Basic» (1T/2P)個々のお客様の状況に応じた、滴定におけるオートメーションの拡張機能の基本モデル。内蔵式Titrando、Swing Headを含むワークステーション、内蔵式ダイヤフラムポンプが2つ装備された省スペース型のロボテックサンプルプロセッサーXL。メソッドのプログラミングは、使い勝手の良いTouch Control滴定ソフトウェア tiamo™、またはOMNISによって行われます。
2.855.0030
Robotic Titrosampler «Light» (1T/1P)中検体数までのサンプルのためのロボテックタイトロサンプラーのエントリーレベルモデル。内蔵式Titrando、ワークステーション、内蔵式ダイヤフラム ポンプが装備された省スペース型のロボテックサンプルプロセッサーXLは、滴定におけるアプリケーションに応じたオートメーションに合わせて、サンプルラックと電極の選択によって拡張できます。滴定溶液の吸引のため、外付けチューブもしくはダイヤフラム ポンプを接続することができます (オプション)。メソッドのプログラミングは、使い勝手の良いTouch Control滴定ソフトウェア tiamo™、またはOMNISによって行われます。サンプル量が増える場合、ロボテックタイトロサンプラー «Light» は容易かつ低コストで、当初のサンプルの何倍もの量を取り扱える «Basic» に拡張することが可能です。
2.855.0040
Robotic Titrosampler «Light» (1T/2P)中検体数までのサンプルのためのロボテックタイトロサンプラーのエントリーレベルモデル。内蔵式Titrando、ワークステーション、内蔵式ダイヤフラムポンプが2つ装備された省スペース型のロボテックサンプルプロセッサーXLは、滴定におけるアプリケーションに応じたオートメーションに合わせて、サンプルラックと電極の選択によって拡張できます。メソッドのプログラミングは、使い勝手の良いTouch Control滴定ソフトウェア tiamo™、またはOMNISによって行われます。サンプル量が増える場合、ロボテックタイトロサンプラー «Light» は容易かつ低コストで、当初のサンプルの何倍もの量を取り扱える «Basic» に拡張することが可能です。
2.855.1010
Robotic Chloride Analyzer塩化物測定のためのコンプリートパッケージには、最小スペース、最短時間で実行できる完全自動塩化物滴定のための全てのコンポーネントが含まれます。装置、付属品、ソフトウェア、アプリケーション・ノウハウなど、全てが含まれています。
2.855.1020
Robotic Acid-Base Analyzer酸および(または)塩基の測定のためのコンプリートパッケージには、最小スペース、最短時間で実行できる完全自動酸塩基滴定のための全てのコンポーネントが含まれます。装置、付属品、ソフトウェア、アプリケーション・ノウハウなど、全てが含まれています。
2.855.1030
OMNIS Software 搭載 Robotic Analyzer LightThe Robotic Analyzer Light package contains all the components for a fully automated titration or measurement in the smallest possible space in a minimum of time.In addition to the Robotic Titrosampler Basic with a rack for 22 samples in 120 mL PP beakers, the package also includes a rod stirrer, a peristaltic pump and a Dosino with 20 mL dosing unit and the OMNIS control software.Only electrode cables, sensors and additional dosing devices as needed must be added, so that it will be available for flexible use as Acid-Base, TAN/TBN, Chloride or Fluoride Analyzer.Should the number of samples increase, then the option also exists of expanding the system to the Robotic Analyzer Basic.
2.855.2010
Robotic TAN/TBN AnalyzerTAN および(または)TBNの測定のためのコンプリートパッケージには、最小スペース、最短時間で実行できる完全自動 TAN/TBN 滴定のための全てのコンポーネントが含まれます。装置、付属品、ソフトウェア、アプリケーション・ノウハウなど、全てが含まれています。
2.855.2020
Robotic Fluoride Analyzerフッ化物測定のためのコンプリートパッケージには、最小スペース、最短時間で実行できる完全自動フッ化物測定のための全てのコンポーネントが含まれます。装置、付属品、ソフトウェア、アプリケーション・ノウハウなど、全てが含まれています。
2.855.3010
OMNIS Software搭載Robotic Analyzer BasicThe Robotic Analyzer Basic package contains all the components for a fully automated titration or measurement in the smallest possible space in a minimum of time.In addition to the Robotic Titrosampler Basic with a rack for 59 samples in 120 mL PP beakers, the package also includes a rod stirrer, a peristaltic pump and a Dosino with 20 mL dosing unit and the OMNIS control software.Only electrode cables, sensors and additional dosing devices as needed must be added, so that it will be available for flexible use as Acid-Base, TAN/TBN, Chloride or Fluoride Analyzer.
2.855.3020
Robotic Transfer Analyzer非常に多量のサンプルにおける酸および塩基の含有量の測定のためのコンプリートパッケージには、最小スペース、最短時間で実行できる完全自動酸塩基滴定のための全てのコンポーネントが含まれます。装置、付属品、ソフトウェア、アプリケーション・ノウハウなど、全てが含まれています。
2.856.0120
856 Conductivity Module 電気伝導度測定セル(ステンレス製)を含むTouch Control付きハイエンドの電気伝導度測定器は900 タッチコントロール、電気伝導度測定セル(ステンレススチール製)、キャリブレーションスタンダードを含む856 導電率モジュールがベースとなっています。ステンレススチール製測定セルは、特に電気伝導度が低い場合の測定に適しています。導電率計モジュールには、プリンター、バーコードリーダーまたはサンプルチェンジャーを接続するUSBインターフェースが2つ、スターラーもしくはドジーノを接続するMSBインターフェースが4つ装備されています。900 タッチコントロールと接続することにより、856 導電率モジュールはGLPおよびFDA 21 CFR part 11の要求仕様を満たします。
2.856.0210
856 Conductivity Module、5-リング電気伝導度測定セルを含むtiamo™ light 付きソフトウェアtiamo™ light、5-リング電気伝導度測定セル、校正標準を含む、パソコンとの稼働用測定モジュール 電気伝導度です。856 Conductivity Module により、電気伝導度と温度だけでなく、TDSと塩分も測定することができます。最新テクノロジーの電気伝導度測定セル、5-リング測定セルがこれをサポートします。 Conductivity Module には、プリンター、バーコードリーダーまたはサンプルチェンジャーを接続するUSBインターフェースが2つ、スターラーまたは Dosino を接続するMSBインターフェースが4つ装備されています。tiamo™ full (2.0以降)と接続することにより、856 Conductivity ModuleはGLPおよびFDA 21 CFR part 11の要求仕様を満たします。
2.856.0220
856 Conductivity Module、tiamo™ light付き、導電率測定セル(ステンレススチール製)付きハイエンドの導電率測定器はtiamo™、導電率(電気伝導度)測定セル(ステンレス製)、キャリブレーションスタンダードを含む856 導電率モジュールがベースとなっています。ステンレススチール製測定セルは、特に電気伝導度が低い場合の測定に適しています。導電率計モジュールには、プリンター、バーコードリーダーまたはサンプルチェンジャーを接続するUSBインターフェースが2つ、スターラーもしくはドジーノを接続するMSBインターフェースが4つ装備されています。tiamo™ (ab 2.0) と接続することにより、856 導電率モジュールはGLPおよびFDA 21 CFR part 11の要求仕様を満たします。
2.856.1210
Conductometric TitratorIP 400に準じた石油製品中の塩基価の測定などといった電導度滴定のための完全なパッケージ。856 Conductivity Module、801 マグネチックスターラ、800 Dosino、807 Dosing Unit (20 mL)、電気伝導度測定セルおよびtiamo™ lightを含む。
2.856.2210
Conductometric Titrator + SolventIP 400に準じた石油製品中の塩基価の測定などといった電導度滴定のための完全なパッケージ。溶媒の自動添加のための追加の2つ目のビュレット付き。856 Conductivity Module、801 マグネチックスターラ、2 x 800 Dosino、2 x 807 Dosing Unit (20 mL および 50 mL)、電気伝導度測定セルおよびtiamo™ lightを含む。
2.856.3210
Conductometric Titrator、Exchange Unit付きComplete package for conductometric titration for the determination of alpha acids in hop products in accordance with EBC 7.4.Including 856 Conductivity Module, 801 Magnetic Stirrer, 805 Dosimat, 20 mL exchange unit, conductivity measuring cell, and tiamo™ light.
2.858.0110
858 Professional Sample Processor for VA and CVS858 Professional Sample Processor for VA and CVSは、Professional VA/CVS装置およびvivaと共に「Cyclic Voltammetric Stripping: サイクリックボルタンメトリーストリッピング」(CVS) を使用して、ブライトナー (「Brightenern」) やサプレッサー (「Suppressoren」) など電気めっき浴における有機添加剤の大量のサンプルシリーズの完全自動処理を可能にします。システムはvivaソフトウェアによって直接制御され、多様な測定方法の中から、自動的にメソッドを変更することができます。一緒に納品されるサンプルラックには、サプレッサー測定用に最高11 mLのサンプルを56個、ブライトナー測定用に最高50 mLのサンプルを28個収容します。858 Professional Sample Processor for VA and CVSでは、内蔵式ロボットアーム、ワークプレイス全体の組立のための付属品、サンプルラック、接続ケーブルも含めて納品されますが、洗浄機器は含まれません。
2.858.0120
サンプル移送のための 858 Professional Sample Processor CVS、Dosino 付きサンプル移送用の Dosino 付き 858 Professional Sample Processor CVS は、Professional VA/CVS 装置および viva と共に「Cyclic Voltammetric Stripping: サイクリックボルタンメトリーストリッピング」(CVS) を使用して、ブライトナー (「Brightener」) やサプレッサー (「Suppressor」) など電気めっき浴における有機添加剤の大量のサンプルシリーズの完全自動処理を可能にします。システムは viva ソフトウェアによって直接制御され、多様な測定方法の中から、自動的にメソッドを変更することができます。一緒に納品されるサンプルラックは、サプレッサー測定用に最高 11 mL のサンプルを 56 個、ブライトナー測定用に最高 50 mL のサンプルを 28 個収容します。測定容器へのサンプル移送には Dosino が使用されます。必要なサンプル量を減らし、自動的に計量できます。サンプル移送用の Dosino 付き 858 Professional Sample Processor CVS は、付属品を含む内蔵式スイングアーム、Dosino、サンプルラック、ワークプレイス全体の組立のための接続ケーブルとともに納品されますが、洗浄機器は含まれません。
2.858.0130
抗酸化物質のための 858 Professional Sample Processor VA抗酸化物質用 858 Professional Sample Processor VA は、Professional VA 装置および viva と組み合わせることで、抗酸化物質濃度を測定するための潤滑剤のサンプルシリーズの完全自動処理を可能にします。システムは viva ソフトウェアによって直接制御されます。同梱のサンプルラックは 24 のサンプルを収容し、これらのサンプルはサンプルチェンジャーでサンプル前処理のため、測定前に自動的に抽出されます。抗酸化物質用 858 Professional Sample Processor for VA は、内蔵式スイングアーム、付属品、サンプルラック、マグネチックスターラ、ワークプレイス全体の組み立てのための接続ケーブルとともに納品されますが、洗浄機器は含まれません。
2.859.0010
859 Titrotherm温度測定の滴定のためのコンピューター制御による滴定モジュール。付属品なし。
2.859.1010
859 Titrotherm komplett (tiamo™付き)温度滴定のためのPC制御による自動滴定装置。 温度滴定のための付属品一式を含む(10 mLのビュレット、プロペラスターラー付き滴定スタンド、サーモプローブ、滴定容器、tiamo™ light)。
2.860.0010
860 KF Thermoprep860 KFサーモプレップはカール フィッシャー水分測定におけるサンプルの加熱による前処理に使用します。多くの物質は、不溶性であったり、カールフィッシャー試薬に反応したり、物質そのものに含まれる水がごくゆっくりと、またはは高温下ではじめて気化したりするために、直接のカール フィッシャー滴定には適していません。ぴったりと気密されたサンプルバイアルびんを使用してサンプルをオーブンに入れ、その後それぞれの容量または電量法カールフィッシャー水分計によって測定します。
2.862.0010
862 Compact Titrosampler862 コンパクトタイトロサンプラ : 自動滴定装置とサンプルチェンジャーが一体化したシステム は、市販の分析天秤のスタンド面の付いた完全自動化された滴定ステーションです。最小スペースで当量点自動検出を含むダイナミック滴定 (DET)および等量滴下滴定 (MET) および終点設定滴定 (SET) を自動で実行するための、コンパクトかつ経済的な装置。計12のポジションにて異なる滴定を完全自動で行い、電極を洗浄、保管することができます。大きく全体像の掴みやすいライブディスプレイによって滴定曲線をひと目ですぐに確認し、サンプルシリーズの直近のステータスを即座に把握することができます。緊急のサンプルは、いつでも優先的に分析を行うことができます。
2.862.0110
862 Compact Titrosampler プリンター付き最小スペースで当量点自動検出を含む変動滴下量当量点滴定(DET)および等量滴下当量点滴定(MET)および終点滴定(SET)を自動で実行するための、コンパクトかつ経済的な装置。2009年IBOデザイン賞にて銀賞を受賞!内容:1 x 862 Compact Titrosampler1 x 802 Stirrer1 x USB 感熱式プリンター Q3X
2.862.1010
862 Food/Beverage Compact Titrosampler862 食品/飲料水向けコンパクトタイトロサンプラ は、食品分野で電位差測定による分析を自動で行うのに非常に適しています。最小スペースで当量点自動検出を含むダイナミック滴定 (DET)、等量滴下滴定 (MET)、および終点設定滴定 (SET) を自動で実行する、滴定装置とサンプルチェンジャーが1つに組み合わされた装置です。862 食品/飲料水向けコンパクトタイトロサンプラ には測定に必要な付属品が装備されており、直ちにご使用いただけます。計12のポジションにて異なる滴定を完全自動で行い、電極を洗浄、保管することができます。大きく全体像の掴みやすいライブディスプレイによって滴定曲線をひと目ですぐに確認し、サンプルシリーズの直近のステータスを即座に把握することができます。緊急のサンプルは、いつでも優先的に分析を行うことができます。
2.862.1110
862 Food/Beverage Compact Titrosampler プリンター付き食品分野におけるほとんどすべての電位差分析を自動で実施するためのコンパクトかつ安価な装置。862 Food/Beverage Compact Titrosampler には包括的な付属品が装備されており、直ちに使用する準備が整っています。2009年IBOデザイン賞にて銀賞を受賞!内容:1 x 862 Compact Titrosampler1 x 802 Stirrer1 x 800 Dosino1 x USB 感熱式プリンター Q3X
2.862.2010
862 Salt Compact Titrosampler862 塩分向けコンパクトタイトロサンプラは、様々なサンプルを電位差測定による塩化物分析を自動で行うのに非常に適しています。最小スペースで当量点自動検出を含むダイナミック滴定 (DET)、等量滴下滴定 (MET)、および終点滴定 (SET) を自動で実行する、滴定装置とサンプルチェンジャーが1つに組み合わされた装置です。862 塩分向けコンパクトタイトロサンプラ には広範囲にわたる付属品が装備されており、直ちにご使用いただけます。計12のポジションにて異なる滴定を完全自動で行い、電極を洗浄、保管することができます。大きく全体像の掴みやすいライブディスプレイによって滴定曲線をひと目ですぐに確認し、サンプルシリーズの直近のステータスを即座に把握することができます。緊急のサンプルは、いつでも優先的に分析を行うことができます。
2.862.2110
862 Salt Compact Titrosampler プリンター付き862 Salt Compact Titrosampler は多様なサンプルにおける塩化物の分析のための完璧なパッケージから構成されています。含まれている付属品はこのアプリケーション向けぴったりに調整されており、簡単かつ迅速な設置と、同梱のUSBプリンターによる明瞭な結果の記録を可能にします。2009年IBOデザイン賞にて銀賞を受賞!内容:1 x 862 Compact Titrosampler1 x 802 Stirrer1 x 800 Dosino1 x USB 感熱式プリンター Q3X
2.863.0020
863 Compact VA Autosampler863 コンパクトICオートサンプラ は、797 VAコンピュートレースを含むボルタンメトリーによる微量成分分析におけるVAシステムを容易に自動化するための、省スペースかつ低コストのオートサンプラーです。本製品で、5~11mLの似通ったサンプルの小さなシリーズを最高18件まで高精度で測定することが可能です。サンプル転送のための内蔵式ペリスタリックポンプを使用します。デバイスは、ワークプレイス全体の組立のための内蔵式サンプルラック、多数の付属品、接続ケーブルが標準で含まれます。
2.864.1130
864 Robotic Balance Sample Processor TAN/TBNロボテックバランスサンプルプロセッサ TAN/TBNにより、石油化学製品の迅速かつ簡単な前処理および分析が可能です。サンプル量は全自動で滴定ビーカーにて秤量され、溶媒に混ぜ合わされ、その後TAN値またはTBNの値が滴定によって測定されます。分析後、滴定ビーカーを空にして、電極を洗浄、調整します。ロボテックバランスサンプルプロセッサで直接前処理をすることによりトレーサビリティは保証され、別個に前処理しておいたサンプルとの取り違えを防ぎます。システム全体は、高機能性が実証済みの滴定および制御ソフトウェア tiamo™ によって管理され、そのデータベースは前処理の各段階(計量を含む)および滴定結果がひと目で分かりやすくなっており、またそれぞれのサンプルは個別に記録されます。
2.865.0010
865 Dosimat plusラボでの滴定および分注作業用ユニバーサルディスペンサー。手動による分注制御のためのプッシュボタンケーブルおよび交換ユニット20 mL 6.3026.220を含む。ドジマットプラスのUSBインターフェースには多数の機器を、しかもUSBハブだけではなく同時に複数のもの(キーボード、マウス、USBコンパクトプリンタまたはUSB DIN A4プリンタ、メソッドおよびデータのバックアップのためのUSBメモリースティック)を接続することができます。オプションのUSB/RS232 アダプターボックス 6.2148.030により、ラボ天秤との接続やパソコンを使用しての制御が可能です。その4つのドージングモードにより、ドジマットプラスは様々な用法が可能となります。:DOS (Dosing) – キーを押してドージングこのモードは特にインジケータによる手動の滴定の実施に適しています。ドージングされた容量から結果が自動的に算出され、結果レポートが印刷されます。XDOS (Extended dosing) – 制御ドージング- 容量指定のドージング: 容量と吐出速度を設定します。- 時間指定のドージング: 容量と時間を設定します。- 吐出速度によるドージング: 吐出速度と時間を設定します。中断無しで持続的なドージングが必要な場合、865 ドジマットプラスを 805 ドジマットと一緒にタンデムモードで稼働させることができます。CNT D (Content dosing) – 標準液およびその他の溶液の生成原物質のサンプル量(固形物もしくは倍液)および指定された目標濃度に基づき、溶媒のドージング量が自動的に算出されます。LQT (Liquid transfer) – 液体をピペットで吸い、希釈します。
2.867.0210
867 pH Module、tiamo™ light付きハイエンドpH/イオン計測器は、tiamo™ light、854 iコネクト、インテリジェントなpHガラス電極 《iユニトロード》 を含む867 pH モジュールをベースとしています。pH モジュールは、pH、温度、mV、Ipol、Upol、濃度の他に 標準添加 (manual、dos、autodos) およびリキッドハンドリング(add、prep、empty) を実施することができます。このモジュールにより、測定のための従来のセンサーおよびインテリジェントセンサーの使用が可能です。ソフトウェアにはGLP準拠の自動のpH電極テストも組み込まれています。pH モジュールには、プリンター、バーコードリーダーまたはサンプルチェンジャーを接続するUSBインターフェースが2つ、スターラーもしくはドジーノを接続するMSBインターフェースが4つ装備されています (予備溶液の添加もしくは標準添加のため)。tiamo™ (2.0以降) に組み入れることにより、GLPおよびFDA 21 CFR part 11の要求仕様を満たします。
2.869.0010
869 Compact Sample Changer869 コンパクトサンプルチェンジャー により、狭い空間でのティトリーノプラスアプリケーションの迅速かつ簡単に自動化できます。このサンプルチェンジャーは、少数の複数測定や小さなサンプルシリーズに適しています。計12のポジションにて異なる滴定を完全自動で行い、電極を洗浄、保管することができます。大きく全体像の掴みやすいライブディスプレイによって、サンプルシリーズの直近のステータスを直接把握し、重要なサンプルはいかなるときでも優先的に分析することができます。様々なメソッドテンプレートをベースとして、アプリケーション特有のメソッドを作成し、保存することができます。コンパクトサンプルチェンジャーとティトリーノプラス 間のコミュニケーションは、追加の制御ボックスやパソコンを要すること無く、遠隔制御信号にて行われます。
2.870.0010
870 KF Titrino plus低価格の870 KFティトリーノプラスは、容量法KF水分測定装置です。この装置により、個体、液体、気体のサンプルの微量なppmから100%までの水分を確実かつ精密に測定することができます。ルーチンユーザーに合わせて作られたユーザーインタフェースにより、870 KFティトリーノプラス は操作も容易で、ごく短い時間で習熟することができます。また頑丈なので、この装置はルーチン測定には理想的な滴定装置です。滴定容器および電極は納品内容に含まれます。
2.870.1010
870 KF Titrino plus completeThe inexpensive 870 KF Titrino plus is a KF titrator for volumetric water content determination. With it, water contents from a few ppm to 100% can be determined reliably and precisely in solid, liquid and gaseous samples.With its user interface, which is tailored to routine users, the 870 Titrino plus is so simple to operate that only brief orientation periods are required. It is the ideal titrator for routine determinations, also because of its robustness. Stirrer, titration vessel, 10 mL exchange unit and electrode are included in the scope of delivery.
2.870.1020
870 KF Titrino plus プリンター付きローコストの870 KF Titrino plus は、容量滴定方式の水分測定のためのカールフィッシャー滴定装置です。この装置により、固体、液体、気体のサンプルの微量なppmから100%までの水分を確実かつ精密に測定することができます。ルーチンユーザーに合わせて調整されたユーザーインタフェースにより、870 Titrino plus は操作も容易で、ごく短い時間で習熟することができます。また頑丈なので、この装置はルーチン測定には理想的な滴定装置です。スターラ、滴定容器、10 mL 交換ユニット、USB 感熱式プリンター Q3X および電極が納品内容に含まれます。
2.870.2010
870 KF Titrino plus and 860 KF ThermoprepThis titration system is comprised of an 870 KF Titrino plus and an 860 KF Thermoprep. This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 860 KF Thermoprep. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 870 KF Titrino plus.
2.871.0010
871 Advanced BioscanPulsed amperometric detector for the highly sensitive determination of sugars, sugar alcohols and sugar acids, polysaccharides and other oxidizable substances. The 871 Advanced Bioscan extends the IC program from Metrohm by adding carbohydrate analysis to the capabilities of ion chromatography. The heart of the 871 Advanced Bioscan is the pulsed amperometric detector with built-in injector and column heater. The system is controlled by the Metrodata IC Net software.Besides carbohydrates the 871 Advanced Bioscan is used to determine oxidizable inorganic anions. There are different measuring cells with either gold, silver, platinum or glassy carbon as electrode material available.
2.874.0120
874 Oven Sample Processor874 Oven Sample Processor はカール フィッシャー滴定のサンプルの加熱自動前処理に使用されます。気化法は特に、高温下においてはじめて水分が気化するサンプルや、難溶性のサンプル、カールフィッシャー試薬に反応するサンプルに適しています。
2.874.0130
874 Oven Sample Processor専用バイアル874 Oven Sample Processorはカール フィッシャー滴定のサンプルの加熱自動サンプル前処理に使用されます。気化法は特に、高温下においてはじめて水分が気化するサンプルや、難溶性のサンプル、カールフィッシャー試薬に反応するサンプルに適しています。この装置は、カスタマイズされたサンプル容器に適合させることが可能です。詳細情報をご希望の場合はメトローム代理店にご連絡ください。
2.875.9020
KF Gas Analyzer (TFT液晶モニター付き)875 KF ガスアナライザー は完全設定された分析システムです。装置には、滴定ソフトウェア tiamo™ full を搭載したコンピューター、キーボードとマウスパッドの付いたモニター、電量法で自動水分測定するための 851 タイトランド が含まれています。液化ガスおよび永久ガスの水分測定のための定義済みメソッドにより、875 KF ガスアナライザーによる作業が簡単に行えます。ガス中の水分測定に加え、システムは液体および固体のサンプルにおける水分測定にも使用することができます。
2.875.9050
875 KF Gas Analyzer モニターなし875 KF Gas Analyzer は完全設定された分析システムです。装置には、滴定ソフトウェアtiamo™ fullがインストールされたコンピューター、自動電量水分測定のための851 Titrandoが含まれています。液化ガスおよび永久ガスの水分測定のための定義済みメソッドにより、875 KF Gas Analyzerによる作業が簡単に行えます。ガス中の水分測定に加え、システムは液体および固体のサンプルにおける水分測定にも使用することができます。規格: ASTM D7995 - 19: 液化ガスサンプラーおよびカールフィッシャー電量滴定を用いた液体ブタン中の水分測定のための標準試験法の要件を完全に満たしています
2.876.0010
876 Dosimat plus手動滴定およびドージングのためのユニバーサルディスペンサー。手動のドージング操作のためのプッシュボタンケーブルおよび交換ユニット20 mLを含みます。ドジマットプラスのUSBインターフェースには多数の機器を、しかもUSBハブだけではなく同時に複数のもの(キーボード、マウス、USBコンパクトプリンタもしくはUSB DIN A4プリンタ、メソッドおよびデータのバックアップのためのUSBメモリースティック)を接続することができます。オプションのUSB/RS232 アダプターボックス 6.2148.030により、ラボ天秤との接続やパソコンを使用しての制御が可能です。その両方のドージングモードにより、ドジマットプラスは以下のような用法が可能となります。:DOS (Dosing) – キーを押してドージングこのモードは特にインジケータによる手動の滴定の実施に適しています。ドージングされた容量から結果が自動的に算出され、結果レポートが印刷されます。XDOS (Extended dosing) – 制御ドージング- 容量指定のドージング: 容量と吐出速度を設定します。- 時間指定のドージング: 容量と時間を設定します。- 吐出速度によるドージング: 吐出速度と時間を設定します。
2.876.0110
876 Manual Titrator plus手動滴定およびドージングのための結果算出機能を含む手動滴定装置 手動のドージング操作のためのマグネチックスターラー、プッシュボタンケーブルおよび交換ユニット20 mLを含みます。ドジマットプラスのUSBインターフェースには多数の機器を、しかもUSBハブだけではなく同時に複数のもの(キーボード、マウス、USBコンパクトプリンタもしくはUSB DIN A4プリンタ、メソッドおよびデータのバックアップのためのUSBメモリースティック)を接続することができます。オプションのUSB/RS232 アダプターボックス 6.2148.030により、ラボ天秤との接続やパソコンを使用しての制御が可能です。その両方のドージングモードにより、ドジマットプラスは以下のような用法が可能となります:DOS (Dosing) – キーを押してドージングこのモードは特にインジケータによる手動の滴定の実施に適しています。ドージングされた容量から結果が自動的に算出され、結果レポートが印刷されます。XDOS (Extended dosing) – 制御ドージング- 容量指定のドージング: 容量と吐出速度を設定します。- 時間指定のドージング: 容量と時間を設定します。- 吐出速度によるドージング: 吐出速度と時間を設定します。
2.877.0010
877 Titrino plus以下の滴定を行えるコンパクトな自動滴定装置 - ポテンショメーターによる終点設定滴定 (SET)- 当量点を自動で検出する等量滴下滴定 (MET)
2.881.3030
881 Metrohm Combustion ICThe 881 Metrohm Combustion IC enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion with subsequent ion chromatography determination (Combustion IC). It comprises all required components, e.g. the Combustion Module from Analytik Jena (2.136.0700), the 920 Absorber Module, the 881 Compact IC pro - Anion - MCS and the MagIC Net™ software. If necessary, the 881 Metrohm Combustion IC package can be supplemented with an Autosampler for solid or liquid samples (MMS 5000 Autosampler). The entire analysis, including sample input and sample digestion, is completely automated and is completely controlled by MagIC Net™.
2.884.0010
884 Professional VA884 Professional VA は、Professional-VA/CVS 装置シリーズへのユニバーサルなエントリーレベル装置です。適切な計測ヘッドおよび適切な電極セットと組み合わせて、マルチモード電極 pro、scTRACE Gold、滴下ビスマス電極を使用したボルタンメトリーおよびポーラログラフィーによる微量分析の測定、またはCVS(サイクリックボルタンメトリーストリッピング)、CPVS(サイクリックパルスボルタンメトリーストリッピング)、CP(クロノポテンショメトリー)による電気めっき浴内の有機添加物の測定を実施することができます。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が新たな展望を開きます。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。交換可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。884 Professional VA は、付属品は少なくなっており、測定ヘッドと電極は付属せずに納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.884.0110
マルチモード電極 (MME) のための 884 Professional VA manualマルチモード電極 (MME) のための 884 Professional VA manual は、マルチモード電極 pro、scTRACE Gold または滴下ビスマス電極を使用したボルタンメトリーおよびポーラログラフィーによるハイエンド微量分析へのエントリーレベル装置です。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が重金属の測定に新たな展望を開きます。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。この装置と組み合わせることで、例えばCVS (サイクリックボルタンメトリーストリッピング)、CPVS (サイクリックパルスボルタンメトリーストリッピング)、CP (クロノポテンショメトリー) による電気めっき浴内の有機添加物の測定など、回転ディスク電極による測定を実施することも可能となります。交換可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。884 Professional VA manual MME仕様は、多数の付属品およびマルチモード電極 pro のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.884.0210
884 Professional VA manual CVS 仕様884 Professional VA manual CVS 仕様は、CVS (サイクリックボルタンメトリーストリッピング)、CPVS (サイクリックパルスボルタンメトリーストリッピング)、CP (クロノポテンショメトリー) による電気めっき浴内の有機添加物のハイエンド測定、または回転ディスク電極によるボルタンメトリー重金属測定へのエントリーレベル装置です。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が CVS に新たな展望を開きます。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。内蔵式温度電極インプット口により、測定中の溶液温度のモニタリングが可能です。この装置により、ボルタンメトリー測定を実施することも可能です。交換可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。884 Professional VA manual CVS仕様は、多数の付属品および回転ディスク電極のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.884.1110
マルチモード電極 (MME) のための 884 Professional VA semiautomated、Dosinos 2 台付きマルチモード電極 (MME) のための 884 Professional VA semiautomated は、マルチモード電極 pro もしくは scTRACE Gold を使用したボルタンメトリーおよびポーラログラフィーによる微量測定のための実用的なハイエンドルーチンアナライザーです。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が重金属の測定に新たな展望を開きます。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。この装置と組み合わせることで、例えばCVS (サイクリックボルタンメトリーストリッピング)、CPVS (サイクリックパルスボルタンメトリーストリッピング)、CP (クロノポテンショメトリー) による電気めっき浴内の有機添加物の測定など、回転ディスク電極による測定を実施することも可能となります。交換可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。同梱の 2 台の 800 Dosino により、例えば電解液、バッファー、標準液など、測定中に予備溶液を自動的に添加させることが可能です。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。マルチモード電極 (MME) のための 884 Professional VA semiautomated は、多数の付属品およびマルチモード電極 pro のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.884.1210
CVS のための 884 Professional VA semiautomated、Dosino 2台付きCVS アプリケーションのための 884 Professional VA semiautomated は、「サイクリックボルタンメトリーストリッピング」(CVS)、「サイクリックパルスボルタンメトリーストリッピング」(CPVS)、クロノポテンショメトリー (CP) による電気めっき浴内の有機添加物の測定、または回転ディスク電極によるボルタンメトリー法重金属測定のための実用的なハイエンドルーチンアナライザーです。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が CVS に新たな展望を開きます。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。内蔵式温度電極インプット口により、測定中の溶液温度のモニタリングが可能です。この装置により、ボルタンメトリー測定を実施することも可能です。交換可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。同梱の 2 台の 800 Dosino により、例えば VMS、標準液や希釈滴定技術 (DT) のためのサンプルなど、測定中に補助溶液を自動的に添加させることが可能です。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。CVS アプリケーションのための 884 Professional VA semiautomated は、多数の付属品および回転ディスク電極のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.884.1310
CVS のための 884 Professional VA semiautomated、Dosino 3台付きCVS アプリケーションのための 884 Professional VA semiautomated は、「サイクリックボルタンメトリーストリッピング」(CVS)、「サイクリックパルスボルタンメトリーストリッピング」(CPVS)、クロノポテンショメトリー (CP) による電気めっき浴内の有機添加物の測定、または回転ディスク電極によるボルタンメトリー法重金属測定のための実用的なハイエンドルーチンアナライザーです。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が CVS に新たな展望を開きます。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。内蔵式温度電極インプット口により、測定中の溶液温度のモニタリングが可能です。この装置により、ボルタンメトリー測定を実施することも可能です。交換可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。同梱の 3 台の 800 Dosino により、例えば VMS、標準液や希釈滴定技術 (DT) のためのサンプルなど、測定中に補助溶液を自動的に添加させることが可能です。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。CVS アプリケーションのための 884 Professional VA semiautomated は、多数の付属品および回転ディスク電極のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.885.0010
885 Compact Oven Sample Changer885 コンパクトオーブンサンプルチェンジャーはカールフィッシャー水分測定の加熱前処理に使用します。オーブン内でサンプルは最高250℃まで加熱されます。その際に水が蒸発し、水は乾燥したキャリアガスによって分析の行われる滴定セルに運ばれます。
2.888.0010
888 Titrandoハイエンド滴定装置(内蔵式ビュレットドライブ付き)付属品なし; 900 Touch Control または OMNIS Software による操作; 変動滴下量当量点滴定 (DET)、等量滴下当量点滴定 (MET)、終点滴定 (SET)、カール フィッシャー滴定 (KFT、OMNISソフトウェアによる操作の場合のみ); 4 つの MSB コネクタ; 絶縁処理の施された測定インターフェース (インテリジェント電極「iTrodes」用にも); USB コネクタ;
2.888.0110
888 Titrando (Touch Control付き)内蔵式ビュレットドライブ付きハイエンド滴定装置- 900 タッチコントロール、マグネチックスターラー 801スターラ、交換ユニット 20 mL、pHガラス電極 《エコトロードプラス》 の組み合わせを含む- ダイナミック滴定 (DET)、等量滴下滴定 (MET)、終点設定滴定 (SET)- 4つのMSBコネクタ- 絶縁処理の施された測定インターフェース (インテリジェントの電極 《I トロード》用にも)- USBコネクタ
2.888.0310
888 Titrando、OMNIS SW付き内蔵式ビュレットドライブ付きハイエンド滴定装置• OMNISスタンドアローンライセンス、マグネチックスターラ801 Stirrer、交換ユニット20 mLおよび複合pHガラス電極 «Ecotrode plus» を含む• 変動滴下量当量点滴定 (DET)、等量滴下当量点滴定 (MET)、終点滴定 (SET)、カール フィッシャー滴定 (KFT)• 4つのMSBコネクタ• 滴定用に2つ目のビュレット(オプション)• 絶縁処理の施された測定インターフェース (インテリジェント電極 «iTrode» 用にも)•USBコネクタ
2.889.0030
889 IC Sample Center Basic889 IC Sample Center Basic は、多くのサンプルを扱うことのできる頑丈なオートサンプラーであり、最新分析ラボの難度の高い作業に最適です。x-y-z原則にもとづいて作動します。二本針システムにより、容器のキャップと隔壁に貫通させることが可能です。メトロームのインテリジェント可変注入テクニックなどを使用して、IC システム内のペリスタリックポンプまたは 800 Dosino でサンプルの搬送を行ないます。MagIC Net 4.1 以上に対応。
2.889.0040
889 IC Sample Center Basic - cool889 IC Sample Center Basic – cool は、使用できるサンプルがごく少量である場合の適切なオートメーションのソリューションです。889 IC Sample Center Basic に対して本製品は更に冷却機能を有しているので、生化学的に重要な、または熱化学的に不安定なサンプルに理想的なサンプルチェンジャーです。メトロームのインテリジェント可変注入テクニックなどを使用して、IC システム内のペリスタリックポンプまたは 800 Dosino でサンプルの搬送を行ないます。MagIC Net 4.1 以上に対応。
2.890.0010
890 Titrandoハイエンド滴定装置 (内蔵式ドージングデバイス付き)、容量滴定方式のカールフィッシャー滴定用。4 つのMSBコネクタ、絶縁処理の施された測定インターフェース、USBコネクタ。900 Touch Control または OMNIS Software による操作KF 滴定容器および KFT 用ダブルポイントリング電極、803 Ti Stand および交換ユニットなし。
2.890.0110
890 Titrando(Touch Control付き)890 タイトランドは、容量法カールフィッシャー水分計です。装置には内蔵式ビュレットドライブ、MSBコネクタが4つ、絶縁処理された測定インターフェース、USBコネクタが1つ装備されています。タイトランドの制御のための接触感度の高い画面を有するタッチコントロール、803 Ti スタンド、10 mLの交換ユニットが同梱されています。
2.890.0310
Titrando KF、OMNIS SW付き890 Titrando は、容量滴定方式のカールフィッシャー滴定のためのハイエンド滴定装置です。装置には内蔵式ビュレットドライブ、MSBコネクタが4つ、絶縁処理された測定インターフェース、USBコネクタが1つ装備されています。タイトランドコントロール用滴定ソフトウェアOMNIS、803 Ti Stand、10 mLの交換ユニットが同梱されています
2.891.0010
891 Professional Analog Out891 プロフェッショナルアナログアウトプットは、様々なクロマトグラフィーデータをアナログ信号として外部のデータ処理システムに伝達するのを可能にするインテリジェントIC機器の追加モジュールです。
2.894.0210
894 Professional CVS manual894 Professional CVS manual は、CVS(サイクリックボルタンメトリーストリッピング)、CPVS(サイクリックパルスボルタンメトリーストリッピング)、CP(クロノポテンショメトリー)による電気めっき浴内の有機添加物のハイエンド測定へのエントリーレベルの装置です。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が CVS に新たな展望を開きます。交換が可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。内蔵式温度電極インプット口により、測定中の溶液温度のモニタリングが可能です。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。894 Professional CVS manual は、多数の付属品および回転ディスク電極のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.894.1210
894 Professional CVS semiautomated、Dosino 2 台付き894 Professional CVS semiautomated は、CVS (サイクリックボルタンメトリーストリッピング)、CPVS (サイクリックパルスボルタンメトリーストリッピング)、CP (クロノポテンショメトリー) による電気めっき浴内の有機添加物の測定のための実用的なハイエンドルーチンアナライザーです。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が CVS に新たな展望を開きます。交換が可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。内蔵式温度電極インプット口により、測定中の溶液温度のモニタリングが可能です。同梱の 2 台の 800 Dosino により、例えば VMS、標準液や希釈滴定技術 (DT) のためのサンプルなど、測定中に補助溶液を自動的に添加させることが可能です。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。894 Professional CVS semiautomated は、多数の付属品および回転ディスク電極のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.894.1310
894 Professional CVS semiautomated、Dosino 3 台付き894 Professional CVS semiautomated は、CVS (サイクリックボルタンメトリーストリッピング)、CPVS (サイクリックパルスボルタンメトリーストリッピング)、CP (クロノポテンショメトリー) による電気めっき浴内の有機添加物の測定のための実用的なハイエンドルーチンアナライザーです。高性能のポテンショスタット/ガルバノスタットと、非常に柔軟な viva ソフトウェアとのコンビネーションにおける熟練した Metrohm の電極技術が CVS に新たな展望を開きます。交換が可能な測定ヘッドにより、異なる電極を持つ様々なアプリケーション間の迅速な交換が可能となります。性能が認証されたキャリブレータの付いたポテンショスタットは、各測定前に自動的に新たに調整を行い、可能な限り高い精度を保証します。内蔵式温度電極インプット口により、測定中の溶液温度のモニタリングが可能です。同梱の 3 台の 800 Dosino により、例えば VMS、標準液や希釈滴定技術 (DT) のためのサンプルなど、測定中に補助溶液を自動的に添加させることが可能です。コントロール、データ処理および評価のためにソフトウェア viva が必要となります。894 Professional CVS semiautomated は、多数の付属品および回転ディスク電極のための測定ヘッドを付属して納品されます。電極セットおよび viva ライセンスは別途ご注文ください。
2.898.0110
898 XYZ Sample Changer 82 x 120 mL898 XYZ サンプルチェンジャーは、その速度と監視無しでも処理できるサンプル数でご納得いただける製品です。それぞれ41×120mLビーカーを有するサンプルラックを2つサンプルチェンジャー上に置き、絶え間なく処理作業を行うことができます。1つ目のサンプルラックの処理が終了するとすぐに、新たなサンプルが入ったラックと交換することができます。ダイヤフラムポンプ付き内蔵式洗浄ステーションにより、使用されるセンサーは常に最適な状態に保たれます。滴定ソフトウェア tiamo™を使用して、パソコン操作で制御が行われます。
2.898.0210
898 XYZ Sample Changer 48 x 250 mL898 XYZ サンプルチェンジャーは、その速度と監視無しでも処理できるサンプル数でご納得いただける製品です。それぞれ24の250mLビーカーを有するサンプルラックを2つサンプルチェンジャー上に置き、絶え間なく処理作業を行うことができます。1つ目のサンプルラックの処理が終了するとすぐに、新たなサンプルが入ったラックと交換することができます。ダイヤフラムポンプ付き内蔵式洗浄ステーションにより、使用されるセンサーは常に最適な状態に保たれます。滴定ソフトウェア tiamo™を使用して、パソコン操作で制御が行われます。
2.899.0010
899 Coulometer(2液型電極付き)スターラーが組み込まれているので、899 クーロメータがラボの卓上で必要とするのはA4サイズ以下のスペースだけです。そのコンパクトなサイズにも関わらず、電量法KF水分計の能力は変わりません。水分が少ない場合でも、トレースレベルまで精密に測定することができます。2液型の指示電極および発生電極が同梱されています。推奨される測定範囲: 水分の絶対量10 µg~200 mg クーロメトリーは液体、固体、気体のトレースレベルにおける水分測定に理想的なメソッドです。更にクーロメトリーは完全なメソッドなので、KF試薬力価測定が必要ありません。
2.899.0110
899 Coulometer(1液型電極付き)スターラーが組み込まれているので、899 クーロメータ がラボの卓上で必要とするのはA4サイズ以下のスペースだけです。そのコンパクトなサイズにも関わらず、電量法KF水分計の能力は変わりません。水分が少ない場合でも、トレースレベルまで精密に測定することができます。2液型の指示電極および発生電極が同梱されています。推奨される測定範囲: 水分の絶対量10 µg~200 mg 電量法カールフィッシャー水分測定法は液体、固体、気体のトレースレベルにおける水分測定に理想的なメソッドです。電量法は完全なメソッドなので、KF試薬力価測定が必要ありません。
2.899.1010
899 Coulometer(2液型電極付き)およびUSB 感熱式プリンター Q3Xスターラーが組み込まれているので、899 Coulometer がラボの卓上で必要とするのはDIN A4の書類以下のスペースだけです。そのコンパクトなサイズにも関わらず、クーロメーターの能力は変わりません。水分が少ない場合でも、トレースレベルまで精密に測定することができます。2液型の指示電極、発生電極、ならびに USB 感熱式プリンター Q3X が同梱されています。推奨測定範囲: 水の絶対量10 µg~200 mgクーロメトリーは液体、固体、気体のトレースレベルにおける水分測定に理想的なメソッドです。更にクーロメトリーは完全なメソッドなので、試薬ファクター測定の必要がありません。
2.899.1110
899 Coulometer(2液型電極付き)およびUSB 感熱式プリンター Neo'sスターラーが組み込まれているので、899 Coulometer がラボの卓上で必要とするのはDIN A4の書類以下のスペースだけです。そのコンパクトなサイズにも関わらず、クーロメーターの能力は変わりません。水分が少ない場合でも、トレースレベルまで精密に測定することができます。1液型の指示電極、発生電極、ならびに USB 感熱式プリンター Q3X が同梱されています。推奨測定範囲: 水の絶対量10 µg~200 mgクーロメトリーは液体、固体、気体のトレースレベルにおける水分測定に理想的なメソッドです。更にクーロメトリーは完全なメソッドなので、試薬ファクター測定の必要がありません。
2.899.2110
899 Coulometer with generator electrode without diaphragm and 860 KF ThermoprepThis titration system is comprised of an 899 Coulometer and an 860 KF Thermoprep.This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 860 KF Thermoprep. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 899 Coulometer.
2.899.3110
899 Coulometer with generator electrode without diaphragm and 885 Compact Oven SCThis titration system is comprised of an 899 Coulometer and an 885 Compact Oven Sample Changer. It offers automated thermal sample preparation with subsequent water content determination in the smallest of spaces.This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 885 Compact Oven Sample Changer. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 899 Coulometer.
2.900.0010
900 Touch Controlタイトランド用オペレーションユニット、USBサンプルプロセッサー、856導電率モジュール、867 pHモジュール、846 ドージングインターフェース。接触感度が高く、高解像度のカラーディスプレイ、メソッドへ直接アクセスするためのお気に入りメニューによる直管的な操作。インターネットに直接繋げるための内蔵式イーサネットインターフェース、USBプリンターまたはUSBメモリースティックと接続するためのUSBインターフェースを含む。ダイアログ言語: ドイツ語、英語、中国語、フランス語、スペイン語、ポルトガル語、ロシア語、韓国語、ポーランド語、イタリア語。
2.901.0010
901 Titrando最新の滴定ラボのためのカール フィッシャーTitrandoハイエンド滴定装置には、カールフィッシャーモード(KFT)の他にもSETモードがあるので、事前に定義した終点へと滴定を行うことができます。「iTrode ready」: 高解像度かつ絶縁処理の施された測定インターフェース(現在は新たにインテリジェント電極«iTrodes»のために追加されたデジタル電極インプット口も含む)により、pH測定を最高精度で実施することが可能です。MSBコネクタが4つあるので、Dosinoを4つまで901 Titrandoに接続することができます。これらは滴定の他、サンプル、標準サンプル、可溶化剤などといった補助溶液の自動添加にも使用することができます。更にあらゆるLQHコマンドが使用できるので、使用済み試薬の吸引と新しい溶媒の添加も自動化させることが可能です。OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用。GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています(必要な場合)
2.902.0010
902 Titrando終点滴定 (SET) のための電位差ハイエンド滴定装置、測定インターフェースを備えた酵素滴定および pH STAT 滴定 (STAT)。 タイプ 800 Dosino のドージングデバイスシステムが 4 つまで; モニタリング、LQH、およびタンデム吐出を備えたドージング機能; 追加スターラーまたはドージングデバイスシステムのための 4 つの MSB コネクタ; 追加の測定インターフェースにより拡張可能; USB コネクタ; OMNIS Software、tiamo ソフトウェアもしくは Touch Control を適用; GMP/GLP 基準および FDA 基準 21 CFR Part 11 の要件を満たしています(必要な場合);
2.904.0010
904 Titrando測定インターフェースおよび内蔵ビュレットドライブを備えた電位差滴定のためのハイエンド滴定装置。 内蔵ビュレットドライブ; 変動滴下量当量点滴定 (DET)、等量滴下当量点滴定 (MET)、終点滴定 (SET); イオン選択性電極を用いた測定 (MEAS CONC); モニタリング、LQHを備えたドージング機能; 追加スターラーまたはドージングシステムのための4つのMSBコネクタ; インテリジェント電極「iTrode」; USB コネクタ; OMNISソフトウェア、tiamoソフトウェアもしくはTouch Controlを適用; GMP/GLP基準およびFDA 基準21 CFR Part 11の要件を満たしています(必要な場合);
- AB-177AB-177石油製品中の臭素価および臭素指数の自動測定
臭素価および臭素指数は、石油製品中の脂肪族 C = C二重結合の測定において重要な品質管理パラメータです。いずれの指標からも、臭素と反応する物質の含有量に関する情報を知ることができます。両指標の違いは、臭素価はサンプル100gあたりの臭素の消費をグラムで、臭素指数は100gあたりの消費量をミリグラムで示すことです。このApplication Bulletinでは、ASTM D1159、ISO 3839、BS2000-130、IP 130、GB/T 11135 および DIN-51774-1に準じた臭素価の測定について説明されています。脂肪族炭化水素のための臭素指数測定は、ASTM D2710、IP 299、GB/T 11136 および DIN 51774-2に準じて説明されています。芳香族炭化水素のためには、臭素指数の測定はASTM D5776 および SH/T 1767に準じて説明されています。UOP 304は、その滴定溶媒に塩化第二水銀が含まれるため、臭素価または臭素指数の測定には推奨されません。
- AB-178AB-178完全自動の水質分析
電気伝導度、pH値、p値およびm値 (アルカリ度)、塩化物含有量、カルシウムおよびマグネシウム硬度、総硬度、ならびにフッ化物含有量などといったか物理的および化学的パラメータの測定は、水質評価において必要不可欠です。この bulletin では、上記のパラメータを、一度の分析実行でいかに測定できるかが説明されています。水質分析においてさらに重要なパラメータは、過マンガン酸塩指数 (PMI) および化学的酸素要求量 (COD) です。そのため、この Bulletin では、EN ISO 8467に準じたPMIの完全自動測定、ならびにDIN 38409-44に準じたCODの測定についても説明しています。
- AB-179AB-179Polarographic determination of maleic and fumaric acid alone or in mixtures
Maleic and fumaric acid can be reduced electrochemically to succinic acid. In acidic solutions a differentiation of the two acids is not possible since both are reduced at the same potential. On the other hand, separation at pH 7.8...8.0 is easily possible since fumaric acid is now more difficult to reduce at the lower proton concentration (as a result of cis-trans isomerism) than maleic acid.
- AB-180AB-180Automatic determination of the formol number in fruit and vegetable juices
The formol number represents a further parameter for the characterization of fruit and vegetable juices. As this is merely an index (the formalin number does not deal with the molecular size, nor with the quantity of amino acids), the conditions of the titration can be adapted to meet practical needs. This concerns mainly the pH value of the endpoint of the SET titration (pH = 8.5, pH = 9.0, pH = 9.2, etc.).
- AB-181AB-181Automatic potentiometric titration of aluminum and magnesium in the same solution
Mixtures of aluminum and magnesium ions can be analyzed automatically using potentiometric titration. The excess DCTA is back-titrated with copper(II) sulfate solution after the addition of 1,2-diaminocyclohexanetetraacetic acid (DCTA) and complex formation. The ion-selective copper electrode is used here as the indicator electrode. First, the aluminum is determined in acidic solution and then the magnesium in alkali solution.
- AB-186AB-186Determination of aluminum in water samples by adsorptive voltammetry
This Bulletin describes the voltammetric determination of aluminum in water samples down to a concentration of 1 μg/L. An aluminum complex is formed with alizarin red S (DASA) and enriched at the HMDE. The following determination employs differential pulse adsorptive stripping voltammetry (DP-AdSV). Disturbing Zn ions are eliminated by addition of CaEDTA.
- AB-188AB-188pH measurement technique
This Bulletin, using practical examples, indicates how the user can achieve optimum pH measurements. As this Bulletin is intended for actual practice, the fundamentals - which can be found in numerous books and publications - are treated only briefly.
- AB-190AB-190ポーラログラフィーによるテレフタル酸中の4-カルボキシベンズアルデヒドの測定
4-カルボキシベンズアルデヒド (以下4-CBA) は、アンモニア性溶液において滴下水銀電極 (DME) で直接還元することができます。ごく簡単なサンプル前処理後、ポーラログラフィーによってppmを下回る範囲まで、テレフタル酸中の4-CBA濃度を迅速かつ正確に測定することが可能です。
- AB-191AB-191ポーラログラフィーによるシステインおよびシスチンの同時測定
生体サンプル (例えば牛乳や羊毛など) の劣化後は、しばしばシステイン/シスチン比率の確認が重要です。このApplication Bulletinでは、2種類のアミノ酸のポーラログラフィーによる同時測定について説明しています。この測定は DME で過塩素酸溶液にて実施されます。タンパク質含有量の高いサンプルでは、測定をアルカリ性溶液で行う必要性があります。
- AB-192AB-192ポーラログラフィーおよびカソードストリッピングボルタンメトリーによる低いmg/Lおよびµg/L範囲におけるチオ尿素の測定
チオ尿素は、水銀と共に不溶性の高い化合物を形成します。その結果生じる陽極波はチオ尿素のポーラログラフィー測定に用いられます。ごく少量 (µg/L) の分析にはカソードストリッピングボルタンメトリー (CSV) が用いられます。示差パルス測定モードはいずれのケースにも用いられます。
- AB-195ニッケルめっき浴中の遊離ホウ酸および テトラフルオロホウ酸の滴定法
このアプリケーションは、ニッケルめっき浴中の遊離ホウ酸および遊離テトラフルオロホウ酸の同時電位差滴定法について解説しています。
- AB-196AB-196ポーラログラフィーによるホルムアルデヒドの測定
ホルムアルデヒドは DME で還元的に測定することが可能です。サンプル組成によって、サンプルでホルムアルデヒドを直接測定できるかどうかは異なります。干渉が生じる場合、吸収、抽出、または蒸留などのサンプル前処理が必要となります。ここでは2つのメソッドについて説明します。1つ目のメソッドでは、ホルムアルデヒドはアルカリ性溶液にて直接還元されます。高濃度のアルカリ度またはアルカリ土類金属は干渉します。このような場合は、2つ目のメソッドを使用することができます。ホルムアルデヒドは、酸性溶液にてポーラログラフィーによって測定することのできるヒドラゾンを形成するヒドラジンを用いて誘導体化されます。
- AB-199AB-199ポーラログラフィーによる硫化物および亜硫酸塩の測定
硫化物および亜硫酸塩は、全く問題なくポーラログラフィーによって測定することができます。硫化物ではポーラログラフィーはアルカリ性溶液にて実施され、亜硫酸塩では弱酸性の一次溶液にて実施されます。このメソッドは医薬品 (輸液)、廃水や排ガス水、写真現像液などの分析に適しています。
- AB-200ポリウレタン原料であるポリオールの酸価、ヒドロキシル価、イソシアネート価 - 様々な規格に準じた自動電位差滴定による測定
ポリウレタンは、最も一般的によく用いられるプラスチックの1種です。これは原料ポリオールのイソシアネートとの反応によって製造されます。この技術資料では、ASTM E1899 および DIN 53240-3に準じた測定について説明されています。
- AB-204AB-204Oxidation stability of oils and fats – Rancimat method
This document outlines Rancimat testing for both liquid and solid food samples, including direct and PEG methods, for oxidation stability QC in the food industry.
- AB-205AB-205Thermostability of PVC and other chlorine-containing polymers
This Application Bulletin describes the determination of the thermostability of PVC in accordance with ISO 182 Part 3 using the dehydrochlorination method with the 895 Professional PVC Thermomat. The instrument permits fully automatic determination of the stability time. The test is suitable for monitoring the manufacture and processing of PVC products manufactured in the injection molding process, for their final clearance, characterization and for the comparison of PVC products and for testing the effectiveness of heat stabilizers.
- AB-206AB-206Titer determination in potentiometry
This Bulletin provides an overview of the potentiometric titer determination of current titrants. Many publications only describe methods with color indicators. However, the titration conditions chosen for the titer determination should resemble those used for the actual analysis as closely as possible. The tables contain suitable titrimetric standard substances and electrodes for selected titrants as well as additional information. Following this, an example is given to show what an SOP for a titer determination could look like.
- AB-207AB-207カーボンRDEを用いたアノードストリッピングボルタンメトリーによる銀の測定
このApplication Bulletinでは、グラッシーカーボンチップ (GC) または超微量グラファイトチップを用いた回転ディスク電極 (RDE) における Ag のストリッピング分析について説明しています。通常操作では銀の測定限界はおよそ 10 μg/L ですが、作業を慎重に行うことで 5 μg/L まで達することも可能です。適切な分解後は、有機成分の含有比率が比較的高いサンプル (例えばワインや食料品など) における銀の測定も可能です。このメソッドは、主に水のサンプル (井戸、地下水および廃水、写真産業における脱銀液) のために開発されたものです。
- AB-209AB-209絶縁油、炭化水素、ならびにその製品に含まれる水分 - カール フィッシャー滴定による正確かつ信頼性の高い測定
カールフィッシャー電量滴定のみが、低水分を充分な精度で測定することができます。このApplication Bulletinでは、ASTM D6304、ASTM E1064、ASTM D1533、ASTM D3401、ASTM D4928、EN IEC 60814、EN ISO 12937、ISO 10337、DIN 51777 および GB/T 11146に準じた直接測定について説明されています。Ovenの技術は、ASTM D6304、EN IEC 60814 および DIN 51777に準じて説明されています。
- AB-211AB-211Sample preparation for ion chromatography
The sample preparation for ion chromatography is divided into steps which should generally be implemented to preserve the column and into steps which should be performed to obtain an improved chromatogram. The goal is to have the test substance in ionic form in solution without the presence of interfering substances.
- AB-213AB-213ポーラログラフィーによるニコチン酸アミドの測定
このApplication Bulletinでは、ビタミンB群の1つであるニコチン酸アミド (ビタミンPP) の測定について説明しています。溶液 (フルーツジュースなど)、ビタミンカプセルおよびマルチビタミン剤における測定のための手引きが示されています。測定の直線性の範囲も指定されています。ニコチン酸アミドの検出限界はおよそ 50 μg/L です。
- AB-215AB-215ポーラログラフィーによる葉酸の測定
このApplication Bulletinでは、ビタミンB群の1つであり、ビタミンB9またはBCとして知られる葉酸の、ポーラログラフィーによる測定について説明されています。溶液 (フルーツジュースなど)、ビタミンカプセルおよびマルチビタミン剤における測定のための手引きが示されています。測定の線形範囲も指定されています。葉酸の検出限界はおよそ 75 μg/L です。
- AB-218AB-218ポーラログラフィーによるチアミン (ビタミンB1) の測定
このApplication Bulletinでは、チアミン (ビタミンB1) のポーラログラフィーによる測定について説明しています。この手順により、モノビタミンの製剤における分析が可能となります。測定の線形範囲も示されています。チアミンの検出限界はおよそ 50 µg/L です。
- AB-219AB-219ポーラログラフィーによるリボフラビン (ビタミンB2) の測定
このApplication Bulletinでは、リボフラビン (ビタミンB ) のポーラログラフィーによる測定について説明されています。この手順により、モノビタミンの製剤における分析が可能となります。測定限界はおよそ 100 μg/L です。
- AB-220AB-220吸着ストリッピングボルタンメトリーによる超微量域の白金およびロジウムの測定
このApplication Bulletinは…
- AB-221AB-221水質分析の標準的な方法
この会報は、水分析の分野からの標準的な方法の調査を提供します。また、それぞれの決定に必要な分析機器と、対応するメトロームアプリケーション速報およびアプリケーションノートへの参照もあります。次のパラメータが処理されます:電気伝導率、pH値、フッ化物、アンモニウムおよびケルダール窒素、イオンクロマトグラフィーによる陰イオンおよび陽イオン、ボルタンメトリーによる重金属、化学酸素需要(COD)、水の硬度、遊離塩素も他のいくつかの水の成分として。
- AB-223AB-223Fully automated determination of uranium
This Bulletin describes the fully automated determination of uranium according to the method of Davies and Gray: Uranium(VI) is reduced in concentrated phosphoric acid solution with iron(II) to form Uranium(IV). With molybdenum as a catalyst, the excess iron(II) is oxidized with nitric acid. The nitrous acid that is formed is destroyed with sulfamic acid before uranium(IV) is titrated with a potassium dichromate solution in the presence of a vanadium catalyst.
- AB-224AB-224ポーラログラフィーによるピドリキシン (ビタミンB6) の測定
このApplication Bulletinでは、ピドリキシン (ビタミンB6) のポーラログラフィーによる測定について説明しています。ここで示されているメソッドにより、モノビタミンおよびいくつかのマルチビタミン製剤における測定が可能となります。分析の線形範囲も指定されています。ピドリキシンHCIの検出限界はおよそ 100 µg/L です。
- AB-225AB-225Simple wine analysis
The Bulletin describes the determination of the following parameters in wine: pH value, total titratable acid, free sulfurous acid, total sulfurous acid as well as ascorbic acid (vitamin C) and other reductones.
- AB-226AB-226Determination of arsenic by stripping voltammetry at the rotating gold electrode
This Bulletin describes the determination of arsenic by anodic stripping voltammetry (ASV) at the rotating gold electrode. A determination limit of 0.5 μg/L can be achieved with 10 mL sample solution. A differentiation between the As(III) concentration and the total arsenic concentration can be made by appropriate selection of the deposition potential. The analyses are performed with a special gold electrode whose active surface is located laterally; c(HCl) = 5 mol/L is used as supporting electrolyte. For the determination of the total arsenic content, As(III) and As(V) are reduced at -1200 mV by nascent hydrogen to As0, which is preconcentrated on the electrode surface. If the deposition is carried out at -200 mV then only As(III) is reduced; this allows the differentiation between total arsenic and As(III). During the subsequent voltammetric determination the preconcentrated As0 is again oxidized to As(III).
- AB-230AB-230Potentiometric determination of nonionic surfactants based on polyoxyethylene adducts with the NIO electrode
The titrimetric determination of nonionic surfactants on the basis of polyoxyethylene adducts (POE adducts) is described in the Bulletin. The basis for the determination is the transfer of the nonionic surfactant into a pseudo-cation compound and its precipitation titration with sodium tetraphenylborate (Na-TPB). The NIO electrode is used for the indication of the potentiometric titration. This Bulletin describes determinations in raw products, formulations and wastewater and draws attention to special features, possibilities, limits and disruptions.
- AB-231AB-231DIN 38406-16に則したアノードおよび吸着ストリッピングボルタンメトリーによる、水サンプルに含まれる亜鉛、カドミウム、鉛、銅、タリウム、ニッケル、およびコバルトの測定
DIN 38406 Part 16 を条件とした標準メソッドでは、飲料水、地下水、地表水、および降水 (雨水など) に含まれるZn、Cd、Pb、Cu、Tl、Ni、およびCoの測定について説明しています。水サンプル中に含まれる有機物質は電圧電流法による測定に強い干渉を与え得るため、過酸化水素を用いたUV分解による前処理が必要となります。この分解により、ブランク値の導入なしですべての有機物質を確実に除去することができます。これらのメソッドはもちろん、例えばシリコンベースの半導体チップの製造における微量分析など、他の物質の微量分析にも応用することができます。Zn、Cd、Pb、Cu、およびTlはアノードストリッピングボルタンメトリー (ASV) を用いてHMDEで測定され、NiおよびCoは吸着ストリッピングボルタンメトリー (AdSV) を用いて測定されます。
- AB-232AB-232Determination of antioxidant activity in accordance with the Rancimat method
The effectiveness of antioxidants can be expressed as antioxidant activity. It can be readily determined using the Rancimat method. This is accomplished by first determining the induction time of a mixture made up of hog fat and the antioxidant to be investigated and then by determining the corresponding time for hog fat alone. The quotient expresses the efficiency of the respective antioxidant and is referred to as the antioxidant activity index (AAI).This Application describes the determination of the antioxidant activity index of five common antioxidants.
- AB-233AB-233Potentiometric determination of anionic and cationic surfactants with surfactant electrodes
Anionic surfactants can be titrated with cationic surfactants and vice-versa. The Bulletin describes a multitude of substances that can be determined in this fashion and specifies the respective working conditions and parameters. In contrast to the classic two-phase titration in accordance with Epton, the titration with the anionic and cationic surfactants electrodes can be performed without chloroform. Furthermore, the equivalence point of the titration is difficult to determine in some cases with the Epton method and the titration cannot be automated.In many cases, a surfactant ISE is a remedy that is both environmentally friendly and suitable here. It was developed specially for application with potentiometrically indicated surfactant determinations.
- AB-235AB-235Potentiometric titration of calcium (magnesium) in dairy products
This Bulletin describes a simple method for the determination of the calcium content in dairy products. The use of CuEGTA and the ion-selective copper electrode (Cu ISE) as indicator electrode allows the determination to be performed without time-consuming sample preparation. If the complexing agent EDTA is used as titrant instead of EGTA, the sum of calcium and magnesium is obtained. The magnesium content can then be calculated from the difference between the results of the two titrations.
- AB-237AB-237Determination of the stability index of solid foods with the Rancimat method
Determination of the oxidation stability of foods with a low fat content is a challenge. As an alternative, the oxidation stability can be specified indirectly. To accomplish this, a determination is made as to the extent that a sample that has been mixed with a fat as a standard solution, e.g., hog fat, will change the oxidation stability of that standard solution. This is accomplished by first determining the induction time of the mixture made up of hog fat and the sample and then by determining the corresponding time for the lard alone. The quotient is referred to as the stability index (SI).
- AB-241AB-241Determination of cadmium and lead by anodic stripping voltammetry at a mercury film electrode
This Application Bulletin describes the determination of cadmium and lead at a mercury film electrode (MFE) by anodic stripping voltammetry (ASV). The mercury film is plated ex situ on a glassy carbon electrode and can be used for up to one day. With a deposition time of 30 s, the limit of detection is ß(Cd2+) = 0.02 µg/L and ß(Pb2+) = 0.05 µg/L. The linear working range for both elements goes up to approx. 50 μg/L using the same deposition time.
- AB-242AB-242超微量グラファイトRDEを用いたアノードストリッピングボルタンメトリーによるタングステンの測定
ここで説明されているメソッドにより、0.2~50 µg/L (ppb) 範囲の微量の W(VI) を測定することが可能となります。サンプル (天然水など) に含まれる微量の有機化合物は干渉します。それらはUV分解によって除去しなければなりません (705 UV Digester など)。100 mg/L までの濃度のFe(III) による干渉は、アスコルビン酸を用いた Fe(lI) への還元によって除去します。もしサンプル中の Cu(II) の量が係数200またはそれ以上で W(VI) の量を上回る場合、Cuイオンはチオ尿素によって固定されなければなりません。さらに、Cu(II) 濃度が 5 mg/L を超えてはなりません。測定はDPモードにおいて吸着ストリッピング分析によって実施されます。
- AB-243AB-243超微量グラファイトRDEを用いた吸着ストリッピングボルタンメトリーによるクロムの測定
このメソッドでは、1~250 μg/L の間の範囲の微量 Cr の測定について説明しています。このメソッドは超微量グラファイト回転ディスク電極 (RDE) におけるCr(lll)-ジフェニルカルバゾナト錯体の吸着をベースとしています。サンプル (天然水など) に含まれる有機化合物は強い干渉効果を有します。そのため、それらはUV分解などによって除去しなければなりません。測定はDC (直流) 測定モードで吸着ストリッピングボルタンメトリーによって実施されます。窒素パージは不要です。測定は、高塩濃度溶液においても良く機能します。
- AB-249AB-249DIN EN ISO 7393-1 および APHA 4500-Cl に基づく遊離残留塩素の測定
塩素は、消毒目的で飲料水にしばしば添加されます。塩素の反応性および濃度によっては、その際に毒性のある消毒副生成物 (DBP) が放出されることがあります。そのため、飲料水の塩素濃度を厳しく管理する必要があります。この Application Bulletin では、DIN EN ISO 7939-1、APHA 4500-Cl メソッド B、および APHA 4500-Cl メソッド I の3つの標準メソッドに従ってどのように塩素濃度を測定するかが示されています。
- AB-250AB-250Polarographic determination of diazepam in body fluids and pharmaceutical preparations
Diazepam belongs to the 1,4-benzodiazepine group of compounds, which are used for medical purposes as tranquilizers and antidepressants. This Bulletin describes the determination of diazepam in tablets and body fluids (blood, serum, urine) by means of differential pulse polarography. If a Britton-Robinson buffer pH = 2.8 with a methanol volume fraction of 20% is used as the supporting electrolyte then a pronounced reduction peak is obtained at -0.73 V; this allows diazepam concentrations even below 0.05 µg/mL to be determined in blood. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-251AB-251Polarographic determination of cinchocaine (dibucaine) in pharmaceutical preparations
Cinchocaine (dibucaine) is used in the form of ointments or injection solutions as a local anaesthetic. Its base is soluble in diethyl ether; its hydrochloride, on the other hand, is insoluble in diethyl ether but easily soluble in water. This Bulletin describes the determination of cinchocaine in ointments, creams and injection solutions by means of differential pulse polarography. An acetate buffer pH = 4.8 is used as the supporting electrolyte. The limit of quantitation and the linear working range of the method are given. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-254AB-254水銀膜電極でのアノードストリッピングボルタンメトリーによる亜鉛、カドミウム、および鉛の測定
このApplication Bulletinでは、水銀膜電極 (MFE) での亜鉛の測定について説明しています。亜鉛は、カドミウムおよび鉛と同時に測定することもできます。MFE での銅の測定はできません。水銀膜は GC 電極上にエクスシトゥ(ex-situ)でめっきされており、半日から1日の間使用することができます。亜鉛は、アノードストリッピングボルタンメトリー (ASV) によって水銀膜電極で測定することができます。多くのサンプルに自然に含まれている銅の存在は、金属間化合物形成の理由から、測定に影響を及ぼします。その結果、測定された亜鉛濃度が低過ぎることになります。ガリウムと銅の金属間化合物は亜鉛と銅の化合物より安定性が高いため、ガリウムを添加することで、干渉をある程度取り除くことができます。蒸着時間 10 秒の場合、検出限界は β(Zn2+) = 0.15 μg/L です。線状の稼動範囲はおよそ 300 μg/L までになります。蒸着時間 10 秒の場合、メソッドは亜鉛含有量 10 μg/L から 150 μg/L のサンプルに適しています。濃度の比較的低いサンプルでは、蒸着時間が例えば 30 秒まで増加した場合に、より信頼度の高い結果が得られます。濃度のより高いサンプルは希釈しなければなりません。
- AB-264AB-264Titrimetric methods for the determination of betains
The two potentiometric titration methods described here allow the determination of the content of commercial betaine solutions. Neither method is suitable for determining the betaine content of formulations. The possibilities and limits of both methods are described and distinctive features and possible sources of interference are mentioned. The Bulletin explains the most important theoretical principles and is intended to help users to develop their own product-specific titration methods.
- AB-265AB-265Hamilton PRP-X100 IC anion column (6.1005.000)
This Bulletin describes the determination by ion chromatography of anions, particularly fluoride, chloride, nitrite, bromide, nitrate, and sulfate using the Hamilton PRPX100 IC anion column without chemical suppression.
- AB-266AB-266吸着ストリッピングボルタンメトリーによるチタンの測定
このApplication Bulletinでは、マンデル酸を錯化剤として用いた吸着ストリッピングボルタンメトリー (AdSV) によるチタンの測定について説明しています。このメソッドは、チタン濃度が重要とされる地下水、飲料水、海水、地表水、および冷却水の分析に適しています。このメソッドはもちろん、他のマトリックスの微量分析にも用いることができます。検出限界はおよそ 0.5 µg/L です。
- AB-268AB-268界面活性剤および医薬品の電位差滴定 - 概要
このBulletinでは、電位差滴定を用いて測定できる数多くの界面活性剤および医薬品の概要をご覧いただけます。Metrohmは滴定の終点を示す5つの異なる界面活性剤電極、すなわちイオン界面活性剤電極、High Sense、Surfactrode Resistant、Surfactrode Refill、NIO界面活性剤電極を提供しています。それぞれの滴定試薬の製造およびそれらの試薬ファクター測定については、詳細に説明されています。 それに加え、このBulletinには、界面活性剤および医薬品分析の分野からの、170を超える数のテスト済みアプリケーションを表形式にした概要が含まれています。このガイドラインは、お客様を確実に目的地までご案内します: どの界面活性剤電極、および、どの滴定試薬がお客様の製品に最も適しているか、この表によって、ひと目でご覧いただけます。
- AB-269AB-269Potentiometric determination of ionic surfactant through two-phase titration with the Surfactrode
On the basis of a multitude of practical examples, this Bulletin describes the potentiometric two-phase titration of ionic surfactants in raw materials and many other formulations.Two surfactant electrodes – the Surfactrode Resistant and the Surfactrode Refill – make it possible to perform this type of surfactant titration, analogous to the classic "Epton titration", with a high degree of automation. The achieved results correlate very well with those of Epton titration. The toxic, carcinogenic and environmentally hazardous chloroform can be replaced by other solvents such as methyl iosbutyl ketone or n-hexane.
- AB-275AB-275Potentiometric two-phase titration of anionic surfactants in washing powder and liquid detergent
Two-phase titration with potentiometric indication is a universal method for the determination of ionic surfactants in detergents. The results obtained are comparable to those with the classic two-phase titration in accordance with Epton (mixed indicator system disulfine blue / dimidium bromide). The present Bulletin addresses various parameters that could have an influence on potentiometric surfactant titration. The information provided makes it possible for the user to determine precisely the anionic surfactant content in practically all formulations.
- AB-280AB-280874 Oven Sample Processor による自動カールフィッシャー水分測定
ガス採取や気化法は原則として、加熱によってその水分を放出するあらゆるサンプルにおいて使用することができます。サンプルに測定の妨げとなる成分が含まれていることにより、またはサンプルの密度の濃さが原因で滴定容器に流入させにくいか、まったく流入させられないことによって、直接的な容量または電量によるカールフィッシャー滴定が不可能な場合には、気化法は不可欠です。既存のApplication Bulletinでは、食品工業やプラスチック工業、ならびに薬品、石油化学のサンプルを例に、気化技術とカールフィッシャー電量滴定による水分の自動測定について説明しています。
- AB-298AB-298Sodium determination in various foods with thermometric titration
In an acidic solution (containing NH4F * HF, Al(NO3)3 / KNO3) sodium forms NaK2AlF6 which precipitates in an exothermic solution, enabling analysis by thermometric titration. Several foods were analyzed, namely bouillon, gravy, tomato ketchup, corn chips, pretzel sticks as well as crackers. The reproducibility of the results was good. After weighing in and adding solutions, samples were crushed with a polytron to ensure homogeneity in the measuring solution. Relative standard deviations were between 0.08% and 3.75%. In addition to this application bulletin, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AB-304AB-304Titration of whole blood and blood plasma for acid-base analysis according to Joergensen and Stirum
The presented Application Bulletin describes the apparatus and methods that are used for acid-base analysis of whole blood and blood plasma by Joergensen and Stirum. Evaluation of the measured data is performed with a software sold by Komstar AG.
- AB-305AB-305界面活性剤測定用電極の検査
この Application Bulletin では、界面活性剤の滴定に使用される界面活性剤測定用電極を検査するためのメソッドについて説明しています。イオン性界面活性剤の滴定のための界面活性剤測定用電極 (Ionic Surfactant electrodes イオン性界面活性剤電極) では、TEGO®trant を用いてドデシル硫酸ナトリウム (SDS または SLS) の測定がおこなわれます。陽イオン性界面活性剤の滴定に使用される界面活性剤測定用電極 (Cationic Surfactant electrodes 陽イオン性界面活性剤電極) では、逆に SDS を用いて TEGO®trant を滴定します。非イオン性界面活性剤の滴定用の電極 (NIO surfactant electrode 非イオン性界面活性剤電極) では、テトラフェニルホウ酸ナトリウム (sodium tetraphenylborate、STPB) を用いて PEG 1000 を滴定します。電極 Surfactrode Resistant および Surfactrode Refill を検査するためには、TEGOtrant を用いて SDS を滴定します。適切な検査基準は、ポテンシャルステップの高さと滴定曲線の形状です。キーワード: NaPh4B
- AB-307AB-307Determination of sulfate in granular phosphate fertilizers with thermometric titration
Sulfate can be rapidly and easily titrated thermometrically using a standard solution of Ba2+ as titrant. In industry, the widespread procedure is applied to the determination of sulfate in wet-process phosphoric acid. This bulletin deals with the determination of sulfate in granular fertilizers such as MAP (monoammonium phosphate), DAP (diammonium phosphate) and TSP (triple superphosphate). Results are reported as percentage of elemental sulfur, %S.
- AB-308AB-308Determination of sulfate in phosphoric acid (liquid fertilizer samples) with thermometric titration
Sulfate can be rapidly and easily titrated thermometrically using a standard solution of Ba2+ as titrant. In industry, the widespread procedure is applied to the determination of sulfate in wet-process phosphoric acid.
- AB-313AB-313Analysis of Bayer process liquors using thermometric titration
The determination of the total causticizer, sodium carbonate and aluminum oxide contents in (Bayer) process liquors can be accomplished with high precision and speed by using the 859 Titrotherm in a thermometric acid-base titration. A complete titration takes approximately 5 minutes.The procedure is an automated adaptation of the traditional Watts-Utley method, and is similar to the VanDalen-Ward thermometric titration method, but with the added advantage that the analysis can also be performed for the carbonate content of the liquor.
- AB-314AB-314Determination of total phosphate in phosphoric acid and phosphate fertilizers with thermometric titration
Phosphate can be rapidly and easily titrated thermometrically using a standard solution of Mg2+ as titrant. The phosphate-containing solution is basified and buffered with NH3/NH4Cl solution before titration. The formation of insoluble MgNH4PO4 is exothermic. The method is a titrimetric adaptation of a classical gravimetric procedure. This bulletin deals with the determination of phosphate in phosphoric acid and granular fertilizers such as MAP (monoammonium phosphate), DAP (diammonium phosphate) and TSP (triple superphosphate). Results are reported as percentage of P and P2O5.
- AB-315AB-315Determination of free fatty acids (FFA) in edible oils with 859 Titrotherm
In titration, the titrant reacts with the analyte either exothermically (gives off heat) or endothermically (absorbs heat). The Thermoprobe measures the temperature change during titration. When all of the analyte has reacted with the titrant, the temperature of the solution will change, and the endpoint of the titration is indicated by an inflection in the temperature curve. Catalytically enhanced titrations using paraformaldehyde as catalyst are based on the endothermic hydrolysis of the paraformaldehyde in the presence of excess hydroxide ions. Edible oils are dissolved in a mixture of toluene and 2-propanol (1:1) and titrated with standardized TBAH (0.01 mol/L) in 2-propanol to a catalytically enhanced endpoint.
- AB-316AB-316Determination of phosphoric acid in liquid fertilizer with thermometric titration
The phosphoric acid content can be easily titrated with a standardized solution of 2 mol/L NaOH. The interfering calcium content in phosphoric fertilizer can be eliminated by adding a saturated oxalate solution.
- AB-317AB-317ポーラログラフィーによる µg/L 範囲での鉄の測定
このApplication Bulletinでは、マルチモード電極での鉄の測定のための2つのメソッドについて説明しています。DMEを用いたポーラログラフィーによる測定であるメソッド1は、濃度が β(Fe) > 200 μg/L である場合に推奨されます。このメソッドにおいて線形範囲は β(Fe) = 800 μg/L 以下です。濃度 < 200 μg/L の場合HMDE を用いたボルタンメトリーによる測定であるメソッド2が推奨されます。このメソッドの検出限界は β(Fe) = 2 μg/L で、定量下限は β(Fe) = 6 μg/L です。沈殿物によってメソッドの感度が高まることはありません。鉄(II) および鉄(III) の感度は、いずれのメソッドにおいても同じです。このメソッドは、水サンプルに含まれる鉄の測定のために開発されました。例えば海水などの高濃度のカルシウムおよびマグネシウムが含まれる水サンプルでは、対応する金属水酸化物の沈殿を防ぐために、わずかに修飾された電解質が用いられます。このメソッドは、適切な分解を行った後に、有機物負荷を伴うサンプル (廃水、飲料、生体液、医薬品、または原油製品) にも用いることができます。
- AB-322AB-322ASTM E1899およびDIN EN ISO 4629-2に準じたヒドロキシル価 (HN) の完全自動電位差測定
ここで紹介する滴定システムは、ASTM E1899およびEN ISO 4629-2に準じたヒドロキシル価 (HN) の完全自動測定にも用いることができます。このメソッドにより、還流下の沸騰またはその他のサンプル前処理もなくポリオールおよびオキソ油を測定できるようになり、これにより多くのサンプルスループットに対処しなければならないラボにとって大きなメリットとなります。EN 15168およびDIN 53240-3規格は、ASTM E1899にあるのと同じ分析メソッドに引き継がれます。
- AB-340AB-340Bromine index (BI) by coulometric titration
This bulletin describes a procedure to determine the bromine index (BI) using coulometric titration. The bromine index is the fraction of reactive unsaturated compounds (mostly C=C double bonds) in hydrocarbons encountered in the petrochemical industry. The double bonds are split with the attachment addition of bromine.
- AB-342AB-342Automated determination of calcium and magnesium in milk with thermometric titration
This bulletin deals with the automated determination of calcium and magnesium in commercially available finished milk products using a 859 Titrotherm and a 814 USB Sample Processor. Calcium and magnesium in milk can be rapidly and easily titrated thermometrically using a standard solution of Na4EDTA as titrant.Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamo (software) using the SLO command. Results are reported as mg Ca and Mg/100 mL.
- AB-343AB-343Automated determination of sodium in milk with thermometric titration
This bulletin discusses automated determination of sodium in milk products available to the public using a 859 Titrotherm and a 814 USB Sample Processor. The sodium content of milk can be rapidly and easily titrated thermometrically with a standard solution of Al3+ as titrant. Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamoTM (software) with the SLO command. Results are reported as mg Na/100 mL. In addition to this application bulletin, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AB-344AB-344Automated analysis of etch acid mixtures for silicon substrates with thermometric titration
This bulletin deals with the automated determination of mixtures of HNO3, HF and H2SiF6 in the range of approximately 200-600 g/L HNO3, 50-160 g/L HF, and 0-185 g/L H2SiF6 using thermometric titration.Etch acid mixtures containing HNO3, HF and H2SiF6 from the etching of silicon substrates can be analyzed in a sequence of two determinations using the 859 Titrotherm. The first determination involves a direct titration with standard c(NaOH) = 2 mol/L, followed by a back titration with c(HCl) = 2 mol/L. This determination yields the H2SiF6 content plus a value for the combined (HNO3+HF) contents. The second determination consists of a titration with c(Al3+) = 0.5 mol/L to determine the HF content. For freshly made up mixtures of HNO3 and HF containing no H2SiF6, a linked two-titration sequence is employed. Results from the two determinations are used by tiamoTM to yield individual results for HNO3, HF and H2SiF6.
- AB-358AB-358Analysis of residual moisture in a lyophilized pharmaceutical product by near-infrared spectroscopy (NIRS)
This Application Bulletin describes the method of near-infrared spectroscopy in diffuse reflection for the purpose of determining residual moisture in a lyophilized pharmaceutical product. Numerous sample vials containing freeze-dried pharmaceuticals were spiked with varying amounts of water for calibration purposes. The resulting differences in the absorption wavelengths of the OH-oscillation were correlated with the water content determined by Karl Fischer titration using the algorithm of multiple linear regression (MLR).
- AB-404AB-404石油製品中の全酸価の測定
全酸価 (TAN) の測定は、石油製品の分析において重要な役割を果たします。この 技術資料では、様々なタイプの滴定を使用した石油製品の全酸価の測定について説明しています。電位差測定は ASTM D664、分光光度測定は ASTM D974、そして温度滴定は ASTM D8045 に準じて解説しています。
- AB-405AB-405Total base number titration of petroleum products
This Application Bulletin shows the determination of the total base number in petroleum products by applying different titration types according to various standards.
- AB-407AB-407MATi 10システム 容量法カールフィッシャー水分測定を全自動化
メトロームのMATi 10 カールフィッシャー水分測定システム(容量法)は、液体や固体サンプルの水分量を全自動で測定できます。 最大 24 サンプルラックに 75 mL のサンプル容器を秤量後セットすれば、あとはシステムが自動で水分測定します。 サンプル容器をアルミホイルでカバーしたままでオートサンプラーにセットおけば、測定待ちの状態での水分蒸発を防いで自動測定が可能です。
- AB-408AB-408ランシマット法による固形食品の酸化安定性試験
ランシマット法は、固形食品の酸化安定性(OSI)および酸化安定指数(SI)を評価する手法である。OSIの測定は、直接測定、抽出した単離脂質を用いた測定、あるいはポリエチレングリコール法によって行うことができる。SIは、サンプルを抗酸化物質を含まない基準脂質と混合することで測定可能である。
- AB-409AB-409Analysis of chemicals using near-infrared spectroscopy
The present Application Bulletin contains NIR applications and feasibility studies for NIRSystems devices in the chemical industry. Qualitative and quantitative analyses of a wide variety of samples are part of this bulletin. Each application describes the instrument that was originally used for the analysis, as well as the system recommended for the analysis and the results that were achieved thereby.
- AB-410AB-410Pharmaceutical analysis using near-infrared spectroscopy
The present Application Bulletin contains NIR applications and feasibility studies using NIRSystems devices in the pharmaceutical industry. Qualitative and quantitative analyses of a wide variety of samples are part of this bulletin. Each application describes the instrument that was originally used for the analysis, as well as the system recommended for the analysis and the results that were achieved thereby.
- AB-411AB-411Analysis of lacquers and paints using near-infrared spectroscopy
Near-infrared spectroscopy is used for a wide range of analyses. Thanks to its fast and non-destructive determination, NIRS is outstandingly suited to quality control of products and raw materials, whether during production or on the finished product. This Application Bulletin shows NIR applications and feasibility studies from the lacquer and paint industry performed using NIRSystems devices.
- AB-412AB-412Pulp and paper analyses using near-infrared spectroscopy
The present Application Bulletin contains NIR applications for the determination of important parameters for pulp and paper quality analysis. Each application describes the instrument that was originally used for the analysis, as well as the system recommended for the analysis and the results that were achieved thereby.
- AB-413AB-413Textile analysis using near-infrared spectroscopy
The present Application Bulletin describes applications that use near-infrared spectroscopy. Each application describes the used and alternatively deployable spectrometer as well as analysis conditions and results and, where available, information on feasibility studies.
- AB-414AB-414Polymer analyses using near-infrared spectroscopy
The present Application Bulletin elucidates several applications for the polymer industry that can be carried out with the aid of NIR instruments. This Bulletin contains analyses of a wide range of parameters in a very large array of samples. The hydroxyl number is one of the best-known of the parameters that can be determined rapidly using near-infrared spectroscopy. The determination of the hydroxyl number in different areas and in different polyol types is also a part of this Bulletin. Each application describes the sample and the instrument that was originally used for the analysis, as well as the recommended instruments and the results.
- AB-416AB-416Determination of arsenic in water with the scTRACE Gold
This Application Bulletin describes the determination of arsenic in water samples by anodic stripping voltammetry using the scTRACE Gold sensor. This method makes it possible to distinguish between As(total) and As(III). With a deposition time of 60 s, the limit of detection for As(total) is 0.9 µg/L, for As(III) it is 0.3 µg/L.
- AB-417AB-417MATi 11システムによる容量法カールフィッシャー水分測定の全自動化
メトロームのMATi11システムは、付属のホモジナイザーでサンプルを自動粉砕して均質化させてからカールフィッシャー水分測定が行えます。 最大 53検体 のサンプルを 120 mL の滴定ビーカーで直接水分測定できます。 サンプルは滴定ビーカーと一緒に秤量後アルミホイルとホイルホルダーで密封させて、サンプルを均質化するための Polytron PT 1300 D が含まれています。 最大 53 のサンプルが 120 mL の滴定ビーカーで直接測定できます。 サンプルは滴定ビーカーで秤量後、水分を失ったり吸収したりしないようにアルミホイルとホイルホルダーで密封してターンテーブルにセットすれば、全自動でサンプル前処理後水分測定できます。
- AB-420AB-420動的加算ボリュームを使用したキャリブレーション手法«smartDT»を使用したCVSによるサプレッサーの決定
Application Bulletinは、smartDTによる酸性銅浴中のサプレッサーの測定について説明しています。希釈滴定(DT)によるサプレッサーの測定には、評価比に到達するための標準溶液またはサンプルの多数の添加が含まれます。通常、固定された等距離の追加ボリュームが使用されます。smartDTでは、ソフトウェアによって動的に計算される可変加算量が使用されます。最初は、ボリュームが大きくなっています。評価率に向けて、添加量を少なくし、精度の高い結果を保証します。オペレーターは、使用する最初の最小の追加ボリュームを定義します。その間のすべてのボリュームは、決定の進行状況を考慮してソフトウェアによって計算されます。追加ボリュームが固定された従来のDTと比較して、smartDTを使用すると、最大40%の時間を節約できます。 smartDTは、線形補間だけでなく、非線形回帰と2次回帰にも適しています。酸性銅浴、スズおよびスズ鉛浴のサプレッサーの測定に使用でき、1、2、および3mmのPt作用電極で機能します。サプレッサー標準またはサンプルの自動追加には、800Dosinoが必要です。この方法は、完全に自動化されたシステムでも使用できます。
- AB-421AB-421Automated coulometric Karl Fischer titration
MATi 4 (Metrohm Automated Titration) is a configured system for automated water content determination in liquid samples using coulometric Karl Fischer titration. The maximum sample volume is 5 mL. Up to 160 samples are filled in glass vials and sealed with lids. This ensures that the water content in the samples remains constant. The samples are aspirated and transferred into the coulometric cell through a needle. The tiamo™ software controls the system.
- AB-422AB-422scTRACE Gold を用いた水に含まれる水銀の測定
この Application Bulletin では、水銀を使用しないVA用電極scTRACE Gold センサーを用いた陽極ストリッピング電圧電流法による水のサンプルに含まれる無機水銀の測定について説明しています。蒸着時間 90 秒の場合、キャリブレーションは 30 µg/L 以上の濃度で線状となり、検出限界はおよそ 0.5 μg/L です。
- AB-423AB-423Improvement of optical focusing properties in mobile Raman systems for pharmaceutical analysis
This Application Bulletin compares the unique focusing technology of the portable Metrohm Raman system "Mira" with conventional methods. The method described here is called Orbital Raster Scan (ORS). Experiments show the advantages of ORS technology, using determination and quantification of medicines as an example. It improves the reproducibility of the Raman signals from targeted, active, pharmaceutical ingredients (APIs) in effervescent, cold medicines. Shorter analysis times and an improved, consistent assignment of spectra of the known medicine with the help of a spectral library are further advantages of ORS technology.
- AB-424AB-424容量法 カールフィッシャー水分測定における力価測定
本アプリケーションは、カールフィッシャー水分測定における力価測定について、特に力価測定に適した水標準品とその正しい取り扱いに関することを説明します。 カールフィッシャー水分測定では、空気中の湿度によって力価が変化するため、力価測定が不可欠です。力価測定の頻度は、滴定溶液と測定システムの気密性の度合いにより異なります。 力価の単位は、mg/mLです。力価測定で計算される値は、滴定溶液 1 mLに対して何 mg の水が反応するかを示します。
- AB-427AB-427Acid number in petroleum products with thermometric titration
This Application Bulletin describes the determination of the total acid number in various oil samples by catalytic thermometric titration as per ASTM D8045.
- AB-428AB-428USP<645>に準拠した導電性のごく低い水サンプルにおける自動電気伝導度測定
この Bulletin ではUSP<645>に準拠した導電性のごく低い水サンプルにおける自動電気伝導度測定について説明しています。電気伝導度測定は、主に製薬分野における注射用の溶液の製造に使われる超純水を例に詳しく説明されています。
- AB-429AB-429scTRACE Gold による水に含まれる銅の測定
銅は、そのままの金属の形で自然界に存在する数少ない金属物質の一つです。さらに融解が比較的容易という事もあり、青銅器時代から既にこの金属は広く使われてきました。今日では、その電気伝導度の高さおよびその他の物理的特性から、銅はこれまで以上に重要となってきています。植物や動物には不可欠な微量元素である一方で、微生物にとっては有毒です。この技術資料では、スクリーンプリント電極であるscTRACE Gold 電極を用いた陽極ストリッピング電圧電流法 (ASV) による銅の測定について紹介しています。蒸着時間 30 秒の場合、検出限界はおよそ 0.5 μg/L です。
- AB-430AB-430DIN 38406-17に則した吸着ストリッピングボルタンメトリーによるウランの測定
このApplication Bulletinでは、DIN 38406 part 17に則した吸着ストリッピングボルタンメトリー (AdSV) によるウランの測定のためのメソッドついて説明しています。このメソッドは、ウラン濃度が重要とされる地下水、飲料水、海水、地表水、および冷却水の分析に適しています。このメソッドはもちろん、他のマトリックスの微量分析にも用いることができます。ウランはクロラニル酸錯体として測定されます。塩化物濃度が低いサンプルでの検出限界はおよそ50 ng/Lで、海水ではおよそ1 µg/Lです。塩化物含有量の高いマトリックスでは、硫酸塩をロードしたイオン交換体を用いて塩化物濃度を下げた後でなければ分析をおこなうことができません。
- AB-431AB-431吸着ストリッピングボルタンメトリーによる鉄、銅、およびバナジウムの測定
このApplication Bulletinでは、鉄、銅、およびバナジウムの成分のボルタンメトリー測定について書かれています。FeもCuもVも、吸着ストリッピングボルタンメトリー (AdSV) によるHMDEでカテコール錯体として測定することができます。Fe(II)およびFe(III)は、リン酸緩衝液またはPIPES電解質にて、いずれの種にも同感度でFe(total) として測定されます。CuおよびVはPIPES緩衝液で測定されます。メソッドは、これらの金属濃度が重要とされる地下水、飲料水、および地表水の調査に主に適しています。しかしこのメソッドは、もちろん他のマトリックスでの微量分析にも用いることができます。PIPES緩衝液におけるこの3つ全ての成分の検出限界は、0.5~1 µg/Lであり、リン酸緩衝液における鉄の検出限界はおよそ5 µg/Lです。
- AB-432AB-432アノードストリッピングボルタンメトリーによる スズ(II) の測定
この Application Bulletin では、アノードストリッピング電圧電流法 (ASV) によるSn(IV)に存在するSn(II)の測定について説明しています。フッ化物の含まれる電解質を用いると、Sn(IV)は何の反応も示さないため、化学種同定が可能となります。検出限界は2.5 µg/Lです。
- AB-433AB-433銀膜によって修飾されたscTRACE Gold による水に含まれる鉛の測定
鉛は強い毒性を有すること、鉛塩は生物に吸収されやすいことで知られています。酵素反応の干渉により、鉛は人体のあらゆる部分に影響を及ぼし得ます。これは脳および腎臓に重大な損傷を与える原因となり、また血液脳関門を通過する可能性があります。水道管システムに使われる鉛地金によって引き起こされる慢性鉛中毒のケースは、よく知られています。そのため、飲料水に含まれる鉛含有量の管理は大変重要です。多くの国々では (EUやアメリカなど) 飲料水に含まれる鉛の限度は10~15 μg/Lと定められています。このApplication Bulletinにて説明されているメソッドにより、これらの濃度を確実に測定することができます。測定は、scTRACE Gold電極に施された銀被膜におけるアノードストリッピングボルタンメトリーによって行われれます。
- AB-434カールフィッシャー水分計によるリチウムイオン電池材料の水分測定
リチウムイオン電池には水が含まれていてはいけません。なぜなら水がLiPF6などの導電性塩と反応してフッ化水素酸を生成してしまうからです。 リチウムイオン電池に使用される材料のなかには、電量法カールフィッシャー水分計で含水量が正確に、高い信頼性で測定できるものがあります。 このアプリケーションでは、以下の材料の測定を取り上げます︓ 1)リチウムイオン電池の原材料(電解質用溶媒、カーボンブラック/グラファイト等) 2)アノードとカソードの電極コーティング剤(スラリー) 3)アノードおよびカソードの被膜とセパレーター膜ならびに複合材料 4)リチウムイオン電池の電解質
- AB-438AB-438滴下ビスマス電極を用いたアノードストリッピングボルタンメトリーによる水サンプルに含まれるカドミウムおよび鉛の測定
重金属、特にカドミウムや鉛は人体にとって毒性が高いことで知られています。そのため、飲料水に含まれるカドミウムと鉛の含有量の管理は大変重要です。多くの国々で飲料水に含まれるカドミウムの限度は3 ~ 5 μg/L、鉛は5 ~ 15 µg/Lと定められています。このApplication Bulletinにて説明されているメソッドにより、これらの微量濃度を確実に測定することができます。測定は、弱酸性電解質における無毒性の滴下ビスマス電極を用いたアノードストリッピングボルタンメトリー (ASV) によって行われれます。
- AB-439AB-439滴下ビスマス電極を用いた水サンプルに含まれる鉄のボルタンメトリー測定
鉄は人間の食事に不可欠な要素で、多くの天然水や処理水中に含まれています。そのため、世界保健機関 (WHO) は健康をベースとした鉄の指針値を発表していません。地表水中に高濃度の鉄が含まれている場合、産業排水の存在、あるいは他の事業や汚染源からの流出を指し示している可能性があります。このため、環境サンプルや産業サンプルにおける正確かつ迅速で高精度な低濃度の鉄の測定は非常に重要です。これは、このApplication Bulletinにて説明されているメソッドによって実施することができます。
- AB-440AB-440滴下ビスマス電極を用いた吸着ストリッピングボルタンメトリーによる水サンプルに含まれるニッケルおよびコバルトの測定
コバルトはビタミンB12の成分であるため、人体に必要不可欠な要素です。コバルト化合物を少し過剰摂取するだけなら人体への毒性はわずかですが、一日25~30 mgを超える多量摂取は、皮膚、肺、胃の疾患、ならびに肝臓、心臓、腎臓に損傷を与えたり、がん腫を発生させたりすることさえあります。同様のことは、高濃度の場合に炎症を引き起こし得るニッケルについても言えます。ニッケルを含む水を多量摂取すると、不快感や吐き気を催すことがあります。EUでは法令に飲料水中のニッケル濃度の限界値が0.02 mg/Lであることが明示されています。この濃度は、このApplication Bulletinにて説明されているメソッドにより、確実に測定することができます。
- AB-441AB-441ピリチオン錯体のアッセイ – 電位差滴定による信頼性が高い完全自動測定
ジンクピリチオン (ZnPT)、銅ピリチオン (CuPT)、ナトリウムピリチオン (NaPT) などといったピリチオン錯体は、防カビ剤や殺菌剤として使用されます。ZnPTは、脂漏性皮膚炎またはフケといった皮膚症状の治療において使用されます。さらに、ZnPTは藻類やカビの生育を防ぐために塗料中で抗菌剤として使用されることもあります。CuPTは、主として水中に沈んでいる表面の生物付着を防ぐための殺生物剤として使用されます。一方、NaPTは水虫などの真菌症を治療するための抗真菌剤として使用されます。 様々なピリチオン錯体は、ヨウ素滴定で測定できます。この技術資料では、自動滴定装置によりPt Titrode電極を使用して、ピリチオン錯体のヨウ素滴定をおこなったアプリケーションを紹介しています。
- AN_RA-010スクリーン印刷電極を用いた農薬のSERS検出
EC-SERSは、電気化学的に活性化した金スクリーン印刷電極(Au SPEs)を用いることでラマン感度を向上させ、複雑な前処理や装置を必要とせずに迅速かつ簡便に農薬を検出することを可能にします。
- AN-AUT-001AN-AUT-001NOVA: オートラボ (Autolab) と リキッドハンドリングを組み合わせた自動サンプルハンドリングと分析
多数のサンプルに対するルーチン測定においては、自動サンプル処理および分析は非常に便利です。メトロームは、高性能なリキッドハンドリング装置を幅広く提供しており、これらはオートラボ (Autolab) 製品シリーズと組み合わせて使用することができ、NOVAソフトウェアによって直接制御することできます。
- AN-AUT-002AN-AUT-002NOVAによる自動サンプル処理と分析:メトローム800ドジーノによる標準添加法
メトローム 800ドジーノは、自動液体処理システムにおける中核的なデバイスです。本デバイスは、NOVAソフトウェアと容易に連携でき、オートラボ8 (Autolab) システムによって行われる電気化学測定にもスムーズに統合することができます。
- AN-AUT-003AN-AUT-003NOVAシステムを用いた、サンプルの自動処理と電気化学分析 ハイスループットに対応します
858プロフェッショナルサンプルプロセッサーは、大量のサンプルを自動処理できるロボット式液体ハンドリングシステムです。NOVAソフトウェアから直接制御できるプラットフォームにより、オートラボ (Autolab) ポテンショスタット/ガルバノスタットと組み合わせることで、ハイスループットの電気化学測定を自動化することができます。
- AN-BAT-001AN-BAT-001High voltage measurements: Characterization of NiMH batteries with Autolab PGSTAT302N in combination with voltage multiplier
A nickel metal hydride battery, abbreviated NiMH, is a type of rechargeable battery similar to a nickel-cadmium (NiCd) battery but, for the anode, instead of cadmium, it has a hydrogen absorbing alloy. Like in NiCd batteries, nickel is the cathode. The voltage output of such packs is directly proportional to the number of single cells in the pack. In some cases, the total voltage can exceed the maximum of 10 V that is measurable by the Autolab potentiostat/galvanostat. To apply and measure voltages greater than 10 V, we have developed a voltage multiplier that increases the voltage range of the Autolab.
- AN-BAT-002AN-BAT-002Galvanostatic charge-discharge of a Li-ion battery with Autolab
Lithium-ion (Li-ion) batteries are one of the most important energy storage devices in the market. A typical Li-ion battery is usually composed of one or more cells. Characterization of Li-ion cells and batteries usually involves the galvanostatic charge and discharge during various cycles.
- AN-BAT-003リチウムイオン電池におけるガルバノスタティック間欠滴定法(GITT)
本アプリケーションノートでは、リチウムイオン電池の反応速度、開回路電圧(OCV)、および拡散挙動を評価するための重要な手法である GITT について、制御および解析を効率化する INTELLO を用いて概説しています。
- AN-BAT-004AN-BAT-004ポテンショスタット間欠滴定法(定電圧間欠滴定法 ;PITT)
リチウムイオン電池 (Li-ion電池) の充電と放電中、リチウムイオンは一方の電極から電解質を通って他方の電極へと輸送されます。電極材料の化学拡散係数を知ることは非常に重要です。ポテンシオスタット間欠滴定法(PITT)は、電極活性材料の拡散係数に関する洞察を得るために最もよく使用される技術の一つです。
- AN-BAT-006Determination of the MacMullin number
The main components of a battery are the positive and negative electrodes, together with the electrolyte, which provides only the ionic conductivity. The most common electrolytes are in the liquid state. Therefore, a separator is needed to provide a physical separation between the electrodes. The separator is soaked with electrolyte. The MacMullin number is a parameter used to determine the quality of a separator, in terms of ionic conductivity, when soaked with an electrolyte. The MacMullin number can be calculated, using the results of data fitting of two EIS experiments and the geometric factors of the measurement cells. In this application note, a commercial electrolyte is employed, together with a porous filter, used as a separator.
- AN-BAT-007AN-BAT-007空気または湿気に敏感な測定のための電気化学的セルを用いて行われるシンプルな CV および EIS テスト測定
TSC SW closed および TSC バッテリーセルは、充電式バッテリーに使われる材料のような空気や湿気に敏感な材料の測定のために開発されたコンパクトなシステムです。これらのセルは、平面配列のメタル電極と接触する、固形物およびゲル状物質の温度管理された測定のために、よく管理された環境を提供します。たとえば、電池活物質、イオン導電性固体状電解質、およびバッテリーセパレータは、これらのセルを用いてテストすることができます。この実験では、セルの効果を理解するために、もしあれば、測定にて、100 Ωの標準抵抗が両方のセルにて用いられます。
- AN-BAT-008AN-BAT-008Metrohm Autolab DuoCoin Cell Holder with EIS measurements on a commercial battery
The DuoCoin Cell Holder is introduced. EIS measurements on a commercial coin cell battery are performed. Differences in impedance between the four-terminal configuration and two-terminal configuration is highlighted, putting in evidence the importance of having a direct four-terminal configuration, when low-impedance DUTs are investigated.
- AN-BAT-009AN-BAT-009バッテリー内部液の二元拡散係数の測定
このApplication Noteでは、定電流パルス分極メソッドに基づいた、民生用液体二元リチウムイオンバッテリー内部液の二元拡散係数の測定方法について紹介しています。
- AN-BAT-010AN-BAT-010固体電解質の界面構造ならびに動力学の研究
このApplication Noteでは、典型的な有機電池電解質と接触した平板GC電極に形成された固体電解質界面のモデルの構造を研究するためのEISおよびCV実験からの、実験詳細および最も重要な発見をご紹介します。
- AN-BAT-011AN-BAT-011リン酸鉄リチウム対称セルにおける EIS による電池電極の厚み方向トーチオシティの測定
この Application Note では、電気化学インピーダンス分光法 (EIS) に基づく、市販リチウムイオン電池正極材料の既知の多孔性と膜厚による厚み方向トーチオシティ τ の測定法をご紹介します。
- AN-BAT-012AN-BAT-012VLF-EIS による電池電解質のリチウムイオン輸率の測定
この Application Note では、超低周波電気化学インピーダンス分光法 (VLF-EIS) に基づいた、市販液体バイナリリチウムイオン電池電解質のリチウムイオン輸率の測定法をご紹介します。
- AN-BAT-013Simultaneous EIS measurements of a Li-ion battery cathode and anode
In battery research, electrochemical impedance spectroscopy (EIS) is a necessary tool to investigate the processes occurring at the electrodes. With a common three-electrode battery, EIS can be performed sequentially first at one electrode and then at the other electrode.
- AN-BAT-014Constant current constant voltage (CCCV) cycling with INTELLO
This Application Note explains how researchers can determine the underlying chemistry and potential failure mechanisms from cycle testing batteries with INTELLO.
- AN-BAT-015INTELLOを使用した電池研究での微分容量解析(DCA)
この技術資料では、微分容量解析(DCA)と電池性能向上への応用について解説しています。この実験では、メトロームの電気化学測定装置 INTELLOを使用しています。
- AN-BAT-016EIS at different states of charge with INTELLO
This application shows how EIS, combined with INTELLO and NOVA, tracks changes in internal battery resistance across SOC levels to study performance and aging mechanisms.
- AN-C-008AN-C-0083-Dimethylamino-1-propylamine in cocoamidopropyl betaine
Determination of 3-dimethylamino-1-propylamine in cocoamidopropyl betaine using cation chromatography with direct conductometric detection.
- AN-C-022AN-C-022Sodium, potassium, calcium, and magnesium in a drip feeding formula using dialysis for sample preparation
Determination of sodium, potassium, calcium, and magnesium in a drip feeding formula using cation chromatography with direct conductivity detection and dialysis as sample preparation.
- AN-C-028AN-C-028Four cations in an instant baby milk powder using dialysis for sample preparation
Determination of sodium, potassium, calcium, and magnesium in instant baby milk powder using cation chromatography with direct conductivity detection and dialysis for sample preparation.
- AN-C-031AN-C-031Calcium and magnesium in high-purity sodium chloride
Determination of calcium and magnesium in high-purity sodium chloride using cation chromatography with direct conductivity detection.
- AN-C-032AN-C-032732 IC検出器を使用したノンサプレッション イオン クロマトグラフィのノイズ低減 - メトローム オート ゼロ / フルスケール アプローチの利点
732 IC 検出器のゼロ機能と適切なフルスケールを併用することで、ベースライン ノイズが大幅に最小限に抑えられます。 はるかに低い検出限界が達成されます。
- AN-C-038AN-C-038Five cations in 4% boric acid
Determination of sodium, ammonium, potassium, calcium, and magnesium in 4% boric acid using cation chromatography with direct conductivity detection.
- AN-C-040AN-C-040Calcium and magnesium in rock extracts
Determination of calcium and magnesium in rock extracts using cation chromatography with direct conductivity detection.
- AN-C-049AN-C-049Trace cations in power plant feed water stabilized with 7 ppm monoethanolamine (MEA)
Determination of zinc, lithium, cobalt, sodium, ammonium, potassium, manganese, magnesium, and calcium in power plant feed water stabilized with 7 ppm monoethanolamine using cation chromatography with direct conductivity detection.
- AN-C-051AN-C-051Determination of aluminum using post-column reaction and UV detection
Determination of aluminum using cation chromatography, post-column reaction and UV detection.
- AN-C-055AN-C-055Determination of lead, zinc, indium, cadmium, cobalt, ammonium, potassium, manganese, magnesium, and calcium
Determination of lead, zinc, indium, cadmium, cobalt, ammonium, potassium, manganese, magnesium, and calcium using cation chromatography with direct conductivity detection.
- AN-C-056AN-C-056Sodium, ammonium, methylamine, guanidine, and aminoguanidine in wastewater
Determination of sodium, ammonium, methylamine, guanidine (Gu), and aminoguanidine (Agu) in wastewater using cation chromatography with direct conductivity detection.
- AN-C-059AN-C-059Sodium, ammonium, and potassium in polyethers
Determination of sodium, ammonium, and potassium in polyethers using cation chromatography with direct conductivity detection.
- AN-C-060AN-C-060Magnesium, strontium, and barium in produced water (11 g/L sodium)
Determination of magnesium, strontium, and barium in produced water using cation chromatography with direct conductivity detection.
- AN-C-061AN-C-061Zinc and manganese in the presence of standard cations in an extract of a zinc compound
Determination of zinc, sodium, ammonium, and manganese in the presence of magnesium and calcium in an extract of a zinc compound using cation chromatography with direct conductivity detection.
- AN-C-062AN-C-062Five cations including iron in monoethylene glycol (MEG)
Determination of sodium, potassium, iron(II), magnesium, and calcium in an extract of monoethylene glycol using cation chromatography with direct conductivity detection.
- AN-C-063AN-C-063Five cations in lithium bromide using post-column reaction
Determination of nickel, zinc, cobalt, iron(II), and manganese in lithium bromide using cation chromatography with UV/VIS detection (520 nm) after post-column reaction with PAR.
- AN-C-064AN-C-064Five cations in betaine
Determination of sodium, ammonium, potassium, calcium, and magnesium in betaine using cation chromatography with direct conductivity detection.
- AN-C-066AN-C-066Four cations in the water soluble fraction of a washing powder
Determination of sodium, potassium, calcium, and magnesium in the water soluble fraction of a washing powder using cation chromatography with direct conductivity detection.
- AN-C-067AN-C-067Cations in grapefruit soft drink using inline dialysis
Determination of sodium, ammonium, potassium, calcium, and magnesium in a grapefruit soft drink using cation chromatography with direct conductivity detection after advanced dialysis for inline sample preparation.
- AN-C-068AN-C-068Cations in functional fruit juice using inline dialysis
Determination of sodium, ammonium, potassium, calcium, and magnesium in a functional fruit juice using cation chromatography with direct conductivity detection after advanced dialysis for inline sample preparation.
- AN-C-069AN-C-069Zinc, sodium, calcium, and magnesium in an industrial bath
Determination of zinc, sodium, calcium, and magnesium in an industrial bath containing cooling lubricants using cation chromatography with direct conductivity detection.
- AN-C-070AN-C-070Cations and biogenic amines in wine
Determination of sodium, potassium, calcium, magnesium, putrescine, cadaverine, and histamine in a wine sample using cation chromatography with direct conductivity detection.
- AN-C-071AN-C-071Choline in a saline solution
Determination of sodium, potassium, DMEA (dimethylethanolamine), calcium, choline, and magnesium in a saline solution using cation chromatography with direct conductivity detection.
- AN-C-073AN-C-073Calcium and magnesium in dolomite
Determination of calcium and magnesium in a dolomite sample using cation chromatography with direct conductivity detection.
- AN-C-074AN-C-074Trimethylamine in hydrogen peroxide (H2O2)
Determination of trimethylamine in hydrogen peroxide (31 %) using cation chromatography with direct conductivity detection after inline matrix elimination, inline preconcentration, and inline calibration.
- AN-C-078AN-C-078Ethanolamines in the presence of alkali metal and alkaline earth cations
Determination of mono-, di-, and trimethanolamine (MMA, DMA, TMA respectively), in the presence of lithium, sodium, ammonium, potassium, magnesium, cesium, calcium, and strontium using cation chromatography with direct conductivity detection.
- AN-C-082AN-C-082Ammonium, magnesium, and calcium in fertilizer
Determination of ammonium, magnesium, and calcium in a fertilizer using cation chromatography with directconductivity detection.
- AN-C-083AN-C-083Online monitoring of trace levels of cations in boiler feed water
Determination of trace levels of lithium, sodium, ammonium, potassium, magnesium, and calcium in boiler feed water using cation chromatography with direct conductivity detection.
- AN-C-084AN-C-084Ammonium, magnesium, and calcium in liquid fertilizer
Determination of ammonium, potassium, magnesium, and calcium in a liquid fertilizer using cation chromatography with direct conductivity detection..
- AN-C-085AN-C-085Betaine in an Echinacea product
Determination of betaine in the presence of standard cations in an Echinacea product using cation chromatography with direct conductivity detection.
- AN-C-086AN-C-086Zinc and standard cations in infusion solutions
Determination of zinc, sodium, potassium, magnesium, and calcium in an infusion solution using cation chromatography with direct conductivity detection.
- AN-C-090AN-C-090Traces of zinc and iron(II) in the presence of the standard cations
Determination of traces of zinc and iron(II) in the presence of lithium, sodium, ammonium, potassium, calcium, and magnesium in boiler water using cation chromatography with direct conductivity detection.
- AN-C-091AN-C-091Magnesium, manganese, and zinc in zinc sulfate solution
Determination of magnesium, manganese, and zinc in a zinc sulfate solution using cation chromatography with direct conductivity detection.
- AN-C-092AN-C-092Amines in fish
Determination of dimethylamine (DMA), trimethylaminoxide (TMAO), trimethylamine (TMA), putrescine, cadaverine, and histamine in a fish sample using cation chromatography with direct conductivity detection.
- AN-C-093AN-C-093Four amines in the presence of standard cations with preconcentration
Determination of traces of methylamine, isopropylamine diethylethanolamine, and diethylamine in the presence of lithium, sodium, ammonium, potassium, magnesium, and calcium using cation chromatography with direct conductivity detection.
- AN-C-095AN-C-095Methylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA) in methylpyrrolidone using Metrohm Inline Matrix Elimination
Determination of traces of methylamine, dimethylamine, and trimethylamine in methylpyrrolidone using cation chromatography with direct conductivity detection.
- AN-C-096AN-C-096Trace analysis of monovalent cations in an ethanolamine matrix (secondary cycle of a pressurized water reactor) using Metrohm Inline Sample Preparation with an 800 Dosino for liquid handling
Methylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA) in methylpyrrolidone using Metrohm Inline Matrix Elimination.
- AN-C-097AN-C-097Cations in ethanol used as biofuel
Determination of traces of lithium, sodium, ammonium, potassium, calcium, and magnesium in ethanol using cation chromatography with direct conductivity detection after Metrohm Inline Matrix Elimination.
- AN-C-098AN-C-098イオンクロマトグラフィによるレアアースを含むレアメタルの微量定量
陽イオンクロマトグラフィによる、ルテチウム、イッテルビウム、ツリウム、エルビウム、テルビウム、ガドリニウム、サマリウム、ネオジム、プラセオジム、セリウム、ランタンの微量定量を紹介したアプリケーションになります。
- AN-C-099AN-C-099イオンクロマトグラフィによる鉱物に含まれるレアアースを含むレアメタルの微量定量
陽イオンクロマトグラフィによる、ガドリニウム、サマリウム、ネオジム、セリウム、ランタンの微量定量を紹介したアプリケーションです。
- AN-C-100AN-C-100Choline in infant milk powder using online dialysis
Determination of choline in infant milk powder using cation chromatography with direct conductivity detection applying Metrohm Inline Dialysis.
- AN-C-101AN-C-101Cations in biodiesel with fully automated aqueous extraction and subsequent dialysis
Determination of potassium, magnesium, and calcium in biodiesel using cation chromatography with direct conductivity detection applying automated extraction and subsequent Metrohm Inline Dialysis.
- AN-C-102AN-C-102Standard cations in orange juice
Determination of sodium, potassium, magnesium, and calcium in orange juice using cation chromatography with direct conductivity detection applying automated dilution and subsequent Metrohm Inline Ultrafiltration.
- AN-C-103AN-C-103Standard cations in lake water on the Metrosep C 3 - 250/4.0 column
Determination of lithium, sodium, potassium, magnesium, and calcium in lake water using cation chromatography with direct conductivity detection.
- AN-C-104AN-C-104Low levels of ammonium in the presence of standard cations on the Metrosep C 3 - 250/4.0 column
Determination of traces of ammonium in the presence of sodium, potassium, magnesium, and calcium using cation chromatography with direct conductivity detection.
- AN-C-105AN-C-105Copper, zinc, iron(II), and manganese in wine by ion chromatography with post-column reaction and UV/VIS detection
Determination of copper, zinc, iron(II), and manganese in red wine using cation chromatography with UV/VIS detection after post-column reaction with PAR.
- AN-C-106AN-C-106Lanthanides by ion chromatography with post-column reaction and UV/VIS detection
Determination of traces of lutetium, ytterbium, thulium, erbium, terbium, gadolinium, samarium, neodymium, praseodymium, cerium, and lanthanum using cation chromatography with gradient elution and UV/VIS detection after post-column reaction with Arsenazo III.
- AN-C-107AN-C-107Hydroxylamine, ethanolamine, triethanolamine, and hydrazine on the Metrosep C 3 - 250/4.0 cation column
Determination of hydroxylamine, ethanolamine, triethanolamine, and hydrazine using cation chromatography with direct conductivity detection.
- AN-C-108AN-C-108Methylamine in the presence of standard cations on the Metrosep C 3 - 250/4.0 cation column
Determination of methylamine in the presence of sodium, ammonium, potassium, magnesium, and calcium using cation chromatography with direct conductivity detection.
- AN-C-109AN-C-109Trans-4-methylcyclohexylamine in a pharmaceutical product
Determination of trans-4-methylcyclohexylamine in a pharmaceutical product using cation chromatography with direct conductivity detection.
- AN-C-110AN-C-110Tributylamine in gabapentine
Determination of tributylamine in a pharmaceutical product (gabapentine) using cation chromatography with direct conductivity detection.
- AN-C-111AN-C-111N-methylpyrrolidone impurity in Cefepime Hydrochloride
Determination of N-methylpyrrolidone (N-MP) in a pharmaceutical product (Cefepime Hydrochloride) using cation chromatography with direct conductivity detection.
- AN-C-112AN-C-112Inline eluent preparation for cation analysis
Long-term determination of standard cations with automatic inline eluent preparation using Dosino and Level Control instruments and cation chromatography with direct conductivity detection.
- AN-C-113AN-C-113Determination of lysine and standard cations in a lysine sample
Determination of lysine as well as sodium, ammonium, potassium, and calcium in bulk lysine using cation chromatography with direct conductivity detection.
- AN-C-114AN-C-114Semi-continuous determination of cations in aerosol using PILS-IC
Determination of sodium, ammonium, potassium, magnesium, and calcium in an ambient aerosol (PM2.5) using aerosol sampling with the PILS (Particle Into Liquid Sampler) and cation chromatography with direct conductivity detection.
- AN-C-115AN-C-115Five cations in tap water
Determination of lithium, sodium, potassium, calcium, and magnesium in tap water using cation chromatography with direct conductivity detection.
- AN-C-116AN-C-116Sodium and potassium in toothpaste
Determination of sodium and potassium in toothpaste using cation chromatography with direct conductivity detection.
- AN-C-117AN-C-117MiPT – Metrohm intelligent Partial Loop Technique
Calibration of lithium, sodium, ammonium, zinc, potassium, magnesium, and calcium using the partial loop technique and cation chromatography with direct conductivity detection. This technique allows a calibration range of 1:100 (e.g. 1 μg/L to 100 μg/L corresponding to 2 μL to 200 μL injected volume) out of 1 calibration solution. Applying the full range of partial loop injection to the samples one calibration covers a sample concentration range of 1 to 10'000 e.g. 2 μL of a 10 mg/L solution corresponds to the highest calibration level (100 μg/L) while 200 μL of a 1 μg/L solution corresponds to the lowest calibration level.
- AN-C-118AN-C-118Impurities in syringe filters – Cations
Determination of lithium, sodium, ammonium, zinc, potassium, magnesium, and calcium impurities in syringe filters using cation chromatography with direct conductivity detection.
- AN-C-119AN-C-119イオンクロマトグラフィによる錠剤中の塩化ベタネコール、ナトリウム、カルシウムの測定
イオンクロマトグラフによる錠剤中の塩化ベタネコール、カルシウム、ナトリウムの測定
- AN-C-120AN-C-120Bethanechol chloride and HPTA (2-hydroxy-propyl-trimethyl ammonium chloride) in the presence of sodium and calcium (Metrosep C 4 - 150/4.0)
Determination of Bethanechol Chloride and HPTA (2-hydroxy-propyl-trimethyl ammonium chloride) besides sodium and calcium using cation chromatography with direct conductivity detection.
- AN-C-121AN-C-121Strontium and barium in monoethylene glycol
Determination of strontium and barium in monoethylene glycol using cation chromatography with direct conductivity detection.
- AN-C-122AN-C-122Cations including total iron content in antifreeze (monoethylene glycol)
Determination of sodium, potassium, iron(II), magnesium and calcium in antifreeze (monoethylene glycol) using cation chromatography with direct conductivity detection. Ascorbic acid reduces iron(III) to iron(II). In this way total iron is determined as iron(II).
- AN-C-123AN-C-123Cations including strontium in brine
Determination of lithium, sodium, ammonium, potassium, calcium, magnesium, and strontium in brine using cation chromatography with direct conductivity detection.
- AN-C-124AN-C-124Ethanolamines in the presence of standard cations (Metrosep C 4 - 150/4.0)
Determination of monoethanolamine (MEA), diethanolamine (DEA), and triethanolamine (TEA) in the presence of lithium, sodium, ammonium, potassium, calcium, and magnesium using cation chromatography with direct conductivity detection.
- AN-C-125AN-C-125Methylamines in the presence of standard cations including cesium (Metrosep C 4 - 150/4.0)
Determination of monomethylamine (MMA), dimethyl-amine (DMA), and trimethylamine (TMA) in the presence of lithium, sodium, ammonium, potassium, cesium, calcium, and magnesium using cation chromatography with direct conductivity detection.
- AN-C-126AN-C-126Methylamines and ethanolamines (Metrosep C 4 - 150/4.0)
Determination of monomethylamine (MMA), dimethylamine (DMA), trimethylamine (TMA), monoethanolamine (MEA), diethanolamine (DEA), and triethanolamine (TEA) using cation chromatography with direct conductivity detection.
- AN-C-127AN-C-127Benzylamine in a beta blocker
Determination of benzylamine in a beta blocker (Nebivolol) using cation chromatography with direct conductivity detection. A step gradient for fast elution of the main component is applied.
- AN-C-128AN-C-128Dimethylamine in Metformin
Determination of dimethylamine in Metformin (N,N-dimethylimidodicarbonimidic diamide, anti-diabetic drug) using cation chromatography with direct conductivity detection.
- AN-C-129AN-C-129Nine cations on the Metrosep C 4 - 150/4.0 column
Determination of lithium, sodium, ammonium, potassium, manganese, calcium, magnesium, strontium, and barium using cation chromatography with direct conductivity detection.
- AN-C-130AN-C-130Cations in offshore effluent
Determination of lithium, sodium, ammonium, potassium, manganese, calcium, magnesium, strontium, and barium in an offshore effluent using cation chromatography with direct conductivity detection.
- AN-C-131AN-C-131Magnesium, cadmium, and iron in phosphoric acid
Determination of magnesium, cadmium, and iron in phosphoric acid using cation chromatography with direct conductivity detection.
- AN-C-132AN-C-132Traces of lithium, sodium, and ammonium in the presence of ethanolamine (Metrosep C 4 - 250/4.0)
Determination of lithium, sodium, ammonium, and monoethanolamine (MEA) using cation chromatography with direct conductivity detection and Metrohm Inline Preconcentration and Inline Calibration.
- AN-C-133AN-C-133Tap water analysis for anions and cations using Metrohm intelligent Partial Loop Technique (MiPT)
Partial loop injection is a well known way of sample introduction to HPLC. In ion chromatography, it is not yet used to a large extent. Liquid handling with Metrohm's Dosino technology now enables to use partial loop injection on a highly reproducible and accurate level. It includes multi-level calibration out of one standard solution. This Application Note shows its use for parallel anion and cation determination in tap water applying one single Sample Processor. The anion results are shown in Application Note S–287.
- AN-C-134AN-C-134Cation Inline Eluent Preparation using an 849 Level Control.
Eluent preparation on demand (EPOD) is the convenient and flexible way of automatic eluent preparation. The 849 Level Control together with an 800 Dosino equipped with a 50 mL dosing unit are used to dilute an eluent concentrate to the required eluent concentration. The use of eluent concentrates is suitable for any eluent. This facilitates unattended operation of the system over several weeks (see AN S-296 for anion eluent preparation).
- AN-C-135AN-C-135Cations in drinking water using Metrosep C 4 - 150/4.0 column according to ISO 14911.
Drinking water analysis is strongly regulated by standards. In this Application Note, the cation determination according to ISO 14911 is shown. The Metrosep C 4 - 150/4.0 is the optimum separation column for this purpose.
- AN-C-136AN-C-136Metrohm intelligent Partial Loop Technique (MiPT) – a single standard calibration: 2 mL vs. 5 mL Dosing Unit
Metrohm intelligent Partial Loop Technique (MiPT) is a versatile injection mode in IC. In this application, injection volumes range from 4 to 200 µL (corresponding to 0.5 - 10 mg/L) using the 250 µL loop. Here, the use of 2 and 5 mL Dosing Units are compared.
- AN-C-137AN-C-137Copper, nickel, zinc, and common cations in the water-steam cycle of a boiling water reactor (BWR)
Water chemistry of the water-steam cycle is crucial for maintaining plant reliability and for ensuring optimal plant operational conditions. Impurities such as corrosion products in ionic, colloidal, or oxide forms are ubiquitous in feedwater, condensate, and reactor coolant. This application shows the determination of sub-ppb levels of Cu, Ni, Zn and standard cations (e.g., Na +, NH 4+, Mg 2+, Ca 2+) in the water-steam cycle of a BWR.
- AN-C-138AN-C-138Zinc, nickel, calcium, and magnesium in borated water of a pressurized water reactor (PWR)
In pressurized water reactors (PWRs), light water is used as primary coolant. Boron (as boric acid) readily absorbs neutrons and is added to the coolant to control reactivity. Lithium hydroxide assures a pH value greater than 7 to prevent corrosion. This application allows to measure sub-ppb levels of zinc, nickel, calcium, and magnesium besides high boric acid and lithium hydroxide concentrations.
- AN-C-139AN-C-139Cations and amines in the water-steam cycle
Water in steel-based cooling systems requires a pH value slightly above 7 to prevent corrosion. Often ammonium or organic amines are applied for pH adjustement. This application shows the separation of typical amines besides inorganic cations. Sample preconcentration applies combined Inline Preconcentration and Matrix Elimination (MiPCT-ME).
- AN-C-140AN-C-140Lithium in borated water of a pressurized water reactor (PWR)
In pressurized water reactors (PWRs), light water is used as coolant in the primary side. Boron (as boric acid) is added to the coolant to absorb neutrons, thus controlling reactivity. Lithium hydroxide assures the alkaline pH value to prevent corrosion. This application allows to measure lithium content besides high boric acid concentrations. AN-C-138 shows the respective trace metal determination on the same system setup.
- AN-C-141AN-C-141Cations in small sample volumes by using the intelligent Pick-up Injection Technique (MiPuT)
The determination of cations in tap water is a simple IC application. Here it is used to present Metrohm's intelligent Pick-up Technique (MiPuT). MiPuT enables the injection of volumes of minimum size from very small sample quantities. In the present case, two volumes of 10 µL from a sample 100 µL in size are used for anion and cation analysis, respectively. The calibration takes place through the injection of various volumes of a single standard solution. AN-S-302 describes the corresponding anion determination.
- AN-C-142AN-C-142Separation of the standard cations on the high-capacity Metrosep C 6 separation columns
The Metrosep C 6 columns have a higher capacity than those of the Metrosep C 4. The present Application Note describes the exceptional separating efficiency for standard cations with the three Metrosep C 6 column lengths available. The outstanding sodium-ammonia separation is particularly noteworthy.
- AN-C-143AN-C-143Ammonia in addition to standard cations in maritime pore water
Maritime pore water contains sodium in the percentage range. The analysis of ammonia in this kind of sample requires a high column capacity and an exceptionally good separation of sodium and ammonia. These requirements are completely fulfilled by a 2 µL injection to the high-capacity Metrosep C 6 - 250/4.0 column.
- AN-C-144AN-C-144微量カチオン測定のためのマトリックス除去を含む可変インライン前濃縮 (MiPCT-ME)
マトリックス除去を伴うメトローム インライン前濃縮技術 (MiPCT-ME) は、前濃縮、マトリックス除去、およびマルチレベル校正を組み合わせた強力な方法です。このアプリケーション ノートでは、この方法論が 2 mg/L アンモニアに加えて微量のナトリウムの測定に適用されます。Metrosep C 6 - 250/4.0 カラムは、選択性の理由から使用されます。
- AN-C-145AN-C-145Ammonium traces besides excess sodium using 940 Professional IC Vario and direct conductivity detection
The determination of low ammonium concentrations besides excess sodium is demanding due to the small retention time difference of these two cations. This Application Note shows direct conductivity detection as an ideal means to detect ammonium in a wastewater sample containing 400 mg/L sodium. AN-S-313 shows the analysis of nitrite traces.
【日本語ウェビナー】イオンクロマトグラフで何が測れるの?
お見積書
Metrohm Japan Office location
White paper: Handheld Raman for RMID in pharma and other regulated industries
Download our free tutorials to learn how simple raw material identification and verification (RMID) can be with MIRA P, even for nontechnical professionals.
White paper: Simplified sulfite determination with ion chromatography
Faster, easier, and more reliable sulfite determination in food and beverage matrices with ion chromatography (amperometric and conductivity detection). Application notes on anion and cations in beer, quality assurance in instant coffee, and more.
ご隠居たちのIC四方山話シーズン4 その13
イオンクロマトグラフィーの試料調製に関わるピーク面積変動について、試料の調製ミスと測定環境からの汚染が原因となる事例について、ご隠居さんがわかりやすく解説します。
Determination of adsorbable organically bound halogens by combustion ion chromatography (DIN 38409-59)
Combustion ion chromatography is a fast and robust method to assess the AOCl, AOBr, AOI, and AOF content in water samples according to DIN 38409.59.
White paper: Creating pipe-flow conditions using a rotating cylinder electrode
Download this White Paper to learn more about simulating pipe-flow conditions using a Rotating Cylinder Electrode.
White paper: Virus detection: Fast, sensitive, and cost-effective with electrochemical testing
Learn more about the possibilities for rapid, widespread testing during pandemic outbreaks using electrochemical techniques for virus detection.
White paper: A guide to Li-ion battery research and development
Free white paper discussing the role of electrochemistry in battery research and development.
White paper: Faster corrosion research results using electrochemical instrumentation
Free white paper describes the effective use of electrochemical techniques to measure corrosion and the effectiveness of inhibitors.
White paper: Experimental versatility and no limits on your cell choice with VIONIC powered by INTELLO
This free white paper demonstrates the multiple setups that are possible with VIONIC powered by INTELLO's Selectable Floating feature.
ホワイトペーパー:化粧品中の天然油脂を酸化安定性試験装置で品質管理
With the Rancimat test, producers of vegetable oils and fats can measure the oxidation stability of their products and guarantee their quality to customers from the cosmetics industry.
White paper: Robust multiparameter analysis of infant and follow-on formulas with ion chromatography (IC)
Free white paper gives comprehensive overview of how to reliably assess the quality of infant formula with ion chromatography.
White paper: When HPLC fails: unleashing the potential of ion chromatography
HPLC is not suitable for analyses of standard ions or cations in water and various foods. For these analyses, ion chromatography (IC) is the method of choice.
White paper: Determination of polyribosylribitol phosphate (PRP) in Haemophilus influenzae vaccine
Download this free white paper to learn more about ion chromatography with pulsed amperometric detection for determining polyribosylribitol phosphate (PRP) in Haemophilus influenzae vaccine.
ご隠居たちのIC四方山話シーズン4 その12
イオンクロマトグラフィにおいて,水は必須条件であり根源です。ということで,今回は水の話をしましょう。純水の品質や取り扱いはピーク面積値の変動においても重要な話題です。
イベント情報
電気化学測定とラマン分光分析を1システムに統合
メトロームグループの2社Autolab社とB&W Tek社は、電気化学測定とラマン分光分析を組み合わせたシステムを作りました。このシステムで材料に関する構造と機能を同時に調べることがでいます。
Thank you
Thank you
お問合せフォーム
メトロームジャパン 会社情報
Thanks mail
Contact
Thank you
Imprint
thankyou
Thank you
Thank you
Thank you
6.6071.640
HazMasterG3 ソフトウェア HazMasterG3®HazMasterG3®は、167000以上の化学物質 (有毒産業用化学物質 (TIC)、有毒産業用物質 (TIM)、化学兵器 (CWA)、出発原料、ブランド名など) に関する不可欠な洞察と重要な指針を提供します。
6.6071.660
Mira DS ラマンスペクトルライブラリ – 化学兵器製剤一般的な化学兵器製剤および前駆物質を含みます。
SERSスペクトルライブラリ - 禁止物質
SERS spectral library of illicit materials commonly encountered by law enforcement in street samples, including heroin, cocaine, methamphetamine, MDMA and more.
SERSスペクトルライブラリ - 禁止物質、デモ
SERS spectral library of illicit materials commonly encountered by law enforcement in street samples, including heroin, cocaine, methamphetamine, MDMA and more.
SERSスペクトルライブラリ - 食品添加物
SERS spectral library of illegal additives and adulterants commonly found in food.
SERSスペクトルライブラリ - 食品添加物、デモ
SERS spectral library of illegal additives and adulterants commonly found in food.
SERSスペクトルライブラリ - 着色料
SERS spectral library of natural and artificial dyes commonly found in food.
SERSスペクトルライブラリ - 着色料、デモ
SERS spectral library of natural and artificial dyes commonly found in food.
SERSスペクトルライブラリ - 殺虫剤
SERS spectral library of pesticides commonly found in food.
SERSスペクトルライブラリ - 殺虫剤、デモ
SERS spectral library of pesticides commonly found in food.
66071700
MIRA 包括的ラマンライブラリMIRA Metrohm 包括的ラマンライブラリは、29,000 件以上もの化学薬品、鉱物、有機化合物、溶媒、ポリマー、染料および顔料、TIC、TIM、無機化合物および有機金属系、パーソナルケア製品、違法物質のスペクトルのエントリをカバーしています。
66071710
MIRA MCRL - ポリマーおよびポリマー添加剤Metrohm 包括的ラマンライブラリ (MCRL) ポリマー及びポリマー添加剤、MIRA 用。
66071720
MIRA MCRL - 無機物および有機金属Metrohm 包括的ラマンライブラリ (MCRL) 無機物および有機金属、MIRA 用。
66071730
MIRA MCRL - 染料、顔料、着色剤Metrohm 包括的ラマンライブラリ (MCRL) 染料、顔料、着色剤、MIRA 用。
66071740
MIRA MCRL - パーソナルケア製品Metrohm 包括的ラマンライブラリ (MCRL) パーソナルケア製品、MIRA 用。
66071750
MIRA MCRL - 有機物Metrohm 包括的ラマンライブラリ (MCRL) 有機物、MIRA 用。
66071760
MIRA MCRL 有機物 - ハロゲン化合物Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - ハロゲン化合物、MIRA 用。
66071770
MIRA MCRL 有機物 - 窒素含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 窒素含有基、MIRA 用。
66071780
MIRA MCRL 有機物 - 酸素含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 酸素含有基、MIRA 用。
66071790
MIRA MCRL 有機物 - 硫黄含有基Metrohm Comprehensive ラマンライブラリ (MCRL) 有機物 - MIRA 用硫黄含有基。
66071800
MIRA Minerals LibraryMetrohm Minerals library for MIRA XTR
66071810
MIRA MCRL - 農薬Metrohm 包括的ラマンライブラリ (MCRL) 農薬、MIRA 用。
66071820
MIRA MCRL - 生化学Metrohm Comprehensive ラマンライブラリ (MCRL) MIRA 用生化学。
66071830
MIRA MCRL - APIMetrohm 包括的ラマンライブラリ (MCRL) 医薬品有効成分 (API)、MIRA 用。
6.6072.150
ポリマープリキャリブレーションのためのバウチャープリキャリブレーションのためのバウチャー。ポリマープリキャリブレーションの要求権限付き (PP、PE、PPまたはポリアミド)
6.6072.151
石油プリキャリブレーションのバウチャープリキャリブレーションのためのバウチャー。石油プリキャリブレーションのご注文にお使いいただけます (ディーゼル、ガソリン、灯油)
6.6072.152
ポリオール・プリキャリブレーションのためのバウチャー6.6072.201
Vision Air 2.0Vision Air - 汎用性に優れた分光法ソフトウェアVision Air は操作の容易な最新のソフトウェアソリューションです。Vision Air の利点の概要: 調整済みのユーザーインターフェースを伴う個別のソフトウェアアプリケーションにより、直観的かつ容易な操作が保証されます。; 作業手順の容易な作成およびメンテナンス; 安全かつ容易なデータ管理のための SQL データベース; バージョン Vision Air (66072201) には以下のアプリケーションが含まれています: 装置管理およびデータ管理のためのアプリケーション; ルーチン分析のためのアプリケーション; メソッド開発のためのソフトウェアを既にお持ちのお客様は、このバージョンをお選びください(Vision、PLS_Toolbox または Unscrambler®)。
6.6072.202
Vision Air 2.0 PharmaVision Air - 汎用性に優れた分光法ソフトウェアVision Air Pharma は、規制環境下での使用のための、操作の容易な最新のソフトウェアソリューションです。Vision Air Pharma の利点の概要: 調整済みのユーザーインターフェースを伴う個別のソフトウェアアプリケーションにより、直観的かつ容易な操作が保証されます。; 作業手順の容易な作成およびメンテナンス; 安全かつ容易なデータ管理のための SQL データベース; Title 21 CFR Part 11の全ての要求を満たします。; バージョン Vision Air Pharma (66072202) には以下のアプリケーションが含まれています: 装置管理およびデータ管理のためのアプリケーション; ルーチン分析のためのアプリケーション; メソッド開発のためのソフトウェアを既にお持ちで(Vision、PLS_Toolbox または Unscrambler®)、規制環境下で作業を行う場合は、このバージョンをお選びください。
6.6072.203
Vision Air 2.0 Network PharmaVision Air - 汎用性に優れた分光法ソフトウェアVision Air Pharma Network Complete は、規制環境下での使用のための、操作の容易な最新のソフトウェアソリューションです。 ネットワークバージョンでは、セントラルデータバンクを伴うグローバルなサーバークライアントネットワークの構築が可能となります。Vision Air の利点の概要: 調整済みのユーザーインターフェースを伴う個別のソフトウェアアプリケーションにより、直観的かつ容易な操作が保証されます。; 一元化されたデータ管理および装置管理; 少ない手順で複数の装置を容易にコンフィグレーション、アップデート; Title 21 CFR Part 11の全ての要求を満たします。; バージョン Vision Air Network Pharma (66072203) には以下のアプリケーションが含まれています: 装置管理およびデータ管理のためのアプリケーション; ルーチン分析のためのアプリケーション; メソッド開発のためのソフトウェアを既にお持ちで(Vision、PLS_Toolbox または Unscrambler®)、規制環境下で作業を行う場合は、このバージョンをお選びください。
6.6072.204
Vision Air 2.0 Serverバージョン Vision Air Server は、Vision Air Network(注文番号: 6.6072.206)を伴うサーバークライアントネットワークの構築に1回限り必要となります。
6.6072.205
Vision Air 2.0 Server Pharmaバージョン Vision Air Server ソフトウェアは、Vision Air Network(注文番号: 6.6072.203)を伴うサーバークライアントネットワークの構築に1回限り必要となります。規制環境下での使用の際はこのバージョンをお選びください。
6.6072.206
Vision Air 2.0 NetworkVision Air - 汎用性に優れた分光法ソフトウェアVision Air Network は操作の容易な最新のソフトウェアソリューションです。ネットワークバージョンでは、セントラルデータバンクを伴うグローバルなサーバークライアントネットワークの構築が可能となります。Vision Air の利点の概要: 調整済みのユーザーインターフェースを伴う個別のソフトウェアアプリケーションにより、直観的かつ容易な操作が保証されます。; 一元化されたデータ管理および装置管理; 少ない手順で複数の装置を容易にコンフィグレーション、アップデート; バージョン Vision Air Network (66072206) には以下のアプリケーションが含まれています: 装置管理およびデータ管理のためのアプリケーション; ルーチン分析のためのアプリケーション; メソッド開発のためのソフトウェアを既にお持ちのお客様は、このバージョンをお選びください(Vision、PLS_Toolbox または Unscrambler®)。
6.6072.300
木材産業のためのプリキャリブレーション近赤外分光法による砕木パルプのカッパー価、密度、破裂強度、引張強度、圧縮強度の測定のためのプリキャリブレーション。
6.6072.301
ポリオール分析のためのプリキャリブレーション近赤外分光法によるポリオール中の水酸基価の測定のためのプリキャリブレーション。
6.6072.302
粗パーム油分析のためのプリキャリブレーション粗パーム油中のヨウ素価、水分、および遊離脂肪酸の測定。
6.6072.303
粗パーム核油分析のためのプリキャリブレーション粗パーム核油中のヨウ素価、水分、および遊離脂肪酸の測定。
6.6072.304
RBD パーム油分析のためのプリキャリブレーションRBD パーム油中のヨウ素価、水分、および遊離脂肪酸の測定
6.6072.305
ディーゼル分析のためのプリキャリブレーションディーゼルのセタン指数とセタン価、密度、ろ過性限界、引火点、および硫黄の測定。
6.6072.306
ガソリン分析のためのプリキャリブレーションガソリンのオクタン価、AKI、ベンゼン、芳香族、アルケン、酸素、および密度の測定。
6.6072.307
ケロシン分析のためのプリキャリブレーションケロシンのセタン指数、芳香族、密度、引火点、水素、粘度、およびその他のパラメータの測定。
6.6072.308
ポリエチレン (PE) のプリキャリブレーション近赤外分光法による、ポリエチレン中の固有粘度と密度の測定のためのプリキャリブレーション。
6.6072.309
ポリプロピレン (PP) のプリキャリブレーション近赤外分光法による、ポリプロピレン中のメルトフローインデックスの測定のためのプリキャリブレーション。
6.6072.310
PETのプリキャリブレーション近赤外分光法による、ポリエチレンテレフタレート (PET) 中の固有粘度と酸価、ジエチレングリコール含有量、イソフタル酸含有量の測定のためのプリキャリブレーション。
6.6072.311
ポリアミド (PA 6) のプリキャリブレーションPre-calibration for determination of relative viscosity, carboxyl end-group content, and amine end-group content in polyamides (PA 6) using NIR spectroscopy.
6.6072.312
イソシアネートのプリキャリブレーション近赤外分光法によるイソシアネート中のNCO数測定のためのプリキャリブレーション。
6.6072.313
大麻のプリキャリブレーションNIRS 分光法を使用した、すりつぶして乾燥させた大麻の花の THC、CBD、CBG および水分測定のプリキャリブレーション。
6.6072.314
ヒト排泄物検体用プリキャリブレーションPre-calibration for the determination of the dry mass of the fat content, the nitrogen content, the water content, and the calorie content using NIR spectroscopy
6.6072.315
リフォーメート用プリキャリブレーションPre-calibration for the determination of RON, density, olefins and aromatic compounds in reformate.
66079000
Metrohm TacticID-1064 ST Comprehensive ラマンライブラリMetrohm TacticID-1064 ST 用の Metrohm Comprehensive ラマンライブラリは、29,000 件以上もの化学薬品、鉱物、有機化合物、溶媒、ポリマー、染料および顔料、TIC、TIM、無機化合物および有機金属系、パーソナルケア製品、違法物質のスペクトルエントリをカバーしています。
66079010
Metrohm TacticID-1064 ST 違法物質および一般化学薬品ライブラリMetrohm TacticID-1064 ST 用の Metrohm 違法物質および一般化学薬品ラマンライブラリには、薬物、TIC、TIM、前駆物質、一般化学薬品が含まれています。
66079020
Metrohm TacticID-1064 ST MCRL - 無機物および有機金属Metrohm TacticID-1064 ST 用の Metrohm Comprehensive ラマンライブラリ (MCRL) 無機物および有機金属。
66079030
Metrohm TacticID-1064 ST MCRL - 有機物Metrohm TacticID-1064 ST 用 Metrohm Comprehensive ラマンライブラリ (MCRL) 有機物。
66079040
Metrohm TacticID-1064 ST MCRL - パーソナルケア製品Metrohm TacticID-1064 ST 用の Metrohm Comprehensive ラマンライブラリ (MCRL) パーソナルケア製品。
66079050
Metrohm TacticID-1064 ST MCRL - ポリマーおよびポリマー添加剤Metrohm TacticID-1064 ST 用 Metrohm Comprehensive ラマンライブラリ (MCRL) ポリマーおよびポリマー添加剤。
66079060
Metrohm TacticID-1064 ST MCRL - 染料、顔料、着色剤Metrohm TacticID-1064 ST 用 Metrohm Comprehensive ラマンライブラリ (MCRL) 染料、顔料、着色剤。
66079070
TDL-EXP: Metrohm TacticID-1064 ST 爆発物ライブラリTDL-EXP: Metrohm TacticID-1064 ST 用爆発物ライブラリ
66079080
TDL-XM-CWA: Metrohm TacticID-1064 ST CWA ライブラリTDL-XM-CWA: Metrohm TacticID-1064 ST用 化学兵器 (CWA) ライブラリ。
66079090
Metrohm TacticID-1064 ST MCRL 有機物 - ハロゲン化合物Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - ハロゲン化合物、Metrohm TacticID-1064 ST 用。
66079100
Metrohm TacticID-1064 ST MCRL 有機物 - 窒素含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 窒素含有基、Metrohm TacticID-1064 ST 用。
66079110
Metrohm TacticID-1064 ST MCRL 有機物 - 酸素含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 酸素含有基、Metrohm TacticID-1064 ST 用。
66079120
Metrohm TacticID-1064 ST MCRL 有機物 - 硫黄含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 硫黄含有基、Metrohm TacticID-1064 ST 用。
66079130
Metrohm TacticID-1064 ST 鉱物ライブラリMetrohm 鉱物ライブラリ、Metrohm TacticID-1064 ST 用。
6.6079.140
SpecSuiteソフトウェアライセンス - 基本ライセンスSpecSuiteソフトウェアの基本ライセンス
6.6079.150
SpecSuiteソフトウェアライセンス - ラボソフトウェア識別識別のためのSpecSuiteライセンス。ライブラリ管理モジュールと識別モジュールを含みます。
66079160
SpecSuiteソフトウェアライセンス - ラボソフトウェア定量化定量化のためのSpecSuiteライセンス。定量モデル開発モジュールと日常的な分析予測を含みます。
66079170
SpecSuiteソフトウェアライセンス - 規制適合規則FDFA 21 CFRパート11 規制適合規則のためのSpecSuiteライセンス。
66079180
SpecSuite ComprehensiveライブラリSpecSuite Metrohm Comprehensiveラマンライブラリ - 27.700件以上もの化学薬品、鉱物、有機化合物、溶媒、ポリマー、染料および顔料、TIC、TIM、無機化合物および有機金属系、パーソナルケア製品、違法物質のスペクトルのエントリをカバーしています。
66079190
SpecSuite MCRL無機物および有機金属 有機金属ライブラリSpecSuiteソフトウェア用Metrohm Comprehensiveラマンライブラリ (MCRL) 無機物および有機金属。
66079200
SpecSuite MCRL有機物完全ライブラリSpecSuiteソフトウェア用Metrohm Comprehensive ラマンライブラリ (MCRL) 有機物。
66079210
SpecSuite MCRLパーソナルケア製品 製品ライブラリSpecSuiteソフトウェア用Metrohm Comprehensiveラマンライブラリ (MCRL) パーソナルケア製品。
66079220
SpecSuite MCRLポリマーおよびポリマー添加剤 添加剤ライブラリSpecSuiteソフトウェア用Metrohm Comprehensiveラマンライブラリ (MCRL) ポリマーおよびポリマー添加剤。
66079230
SpecSuite MCRL染料、顔料、着色剤ライブラリSpecSuiteソフトウェア用Metrohm Comprehensiveラマンライブラリ (MCRL) 染料、顔料、着色剤。
66079240
SpecSuite鉱物ライブラリSpecSuiteソフトウェア用Metrohm鉱物ライブラリ。
66079250
SpecSuite Comprehensive USPライブラリSpecSuite用Metrohm Comprehensive USPラマンライブラリ、追跡可能な認定物質を最大900品目までカバー。
66079260
SpecSuite Illicit and General ChemicalsライブラリSpecSuiteソフトウェア用Metrohm Illicit and General Chemicalsラマンライブラリ。薬物、TIC、TIM、前駆物質、一般的な化学物質を含みます。
66079270
SpecSuite 爆発物ライブラリSpecSuite ソフトウェア用 爆発物ライブラリ。
66079280
SpecSuite CWA(化学兵器)ライブラリSpecSuite ソフトウェア用 化学兵器 (CWA) ライブラリ。
66079290
Metrohm TacticID-1064 ST MCRL - 農薬Metrohm 包括的ラマンライブラリ (MCRL) 農薬、Metrohm TacticID-1064 ST 用。
66079300
Metrohm TacticID-1064 ST MCRL - 生化学Metrohm 包括的ラマンライブラリ (MCRL) 生化学、Metrohm TacticID-1064 ST 用。
66079310
Metrohm TacticID-1064 ST MCRL - APIMetrohm 包括的ラマンライブラリ (MCRL) 医薬品有効成分 (API)、Metrohm TacticID-1064 ST 用。
66079320
TacticID Mobile MCRL - 農薬Metrohm 包括的ラマンライブラリ (MCRL) 農薬、TacticID Mobile 用。
66079330
TacticID Mobile MCRL - 生化学Metrohm 包括的ラマンライブラリ (MCRL) 生化学、TacticID Mobile 用。
66079340
TacticID Mobile MCRL - APIMetrohm 包括的ラマンライブラリ (MCRL) 医薬品有効成分 (API)、TacticID Mobile 用。
66079350
TacticID-1064/ST MCRL - 農薬Metrohm 包括的ラマンライブラリ (MCRL) 農薬、BWT TacticID-1064 および BWT TacticID-1064 ST 用。
66079360
TacticID-1064/ST MCRL - 生化学Metrohm 包括的ラマンライブラリ (MCRL) 生化学、BWT TacticID-1064 および BWT TacticID-1064 ST 用。
66079370
TacticID-1064/ST MCRL - APIMetrohm 包括的ラマンライブラリ (MCRL) 医薬品有効成分 (API)、BWT TacticID-1064 および BWT TacticID-1064 ST 用。
66079380
TacticID-N Plus MCRL - 農薬Metrohm 包括的ラマンライブラリ (MCRL) 農薬、TacticID-N Plus 用。
66079390
TacticID-N Plus MCRL - 生化学Metrohm 包括的ラマンライブラリ (MCRL) 生化学、TacticID-N Plus 用。
66079400
TacticID-N Plus MCRL - APIMetrohm 包括的ラマンライブラリ (MCRL) 医薬品有効成分 (API)、TacticID-N Plus 用。
66079410
NanoRam-1064 MCRL - 染料、顔料、着色剤Metrohm 包括的ラマンライブラリ (MCRL) 染料、顔料、着色剤、NanoRam-1064 用。
66079420
NanoRam-1064 MCRL - 無機物および有機金属Metrohm 包括的ラマンライブラリ (MCRL) 無機物および有機金属、NanoRam-1064 用。
66079430
NanoRam-1064 MCRL 有機物 - ハロゲン化合物Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - ハロゲン化合物、NanoRam-1064 用。
66079440
NanoRam-1064 MCRL Organics - 窒素含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 窒素含有基、NanoRam-1064 用。
66079450
NanoRam-1064 MCRL Organics - 酸素含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 酸素含有基、NanoRam-1064 用。
66079460
NanoRam-1064 MCRL 有機物 - 硫黄含有基Metrohm Comprehensive ラマンライブラリ (MCRL) 有機物 - NanoRam-1064 用硫黄含有基。
66079470
NanoRam-1064 MCRL - パーソナルケア製品Metrohm 包括的ラマンライブラリ (MCRL) パーソナルケア製品、NanoRam-1064 用。
66079480
NanoRam-1064 MCRL - ポリマーおよびポリマー添加剤Metrohm 包括的ラマンライブラリ (MCRL) ポリマーおよびポリマー添加剤、NanoRam-1064 用。
66079490
NanoRam-1064 MCRL - 生化学Metrohm 包括的ラマンライブラリ (MCRL) 生化学、NanoRam-1064 用。
66079500
NanoRam-1064 MCRL - APIMetrohm 包括的ラマンライブラリ (MCRL) 医薬品有効成分 (API)、NanoRam-1064 用。
66079510
NanoRam-1064 MCRL - 農薬Metrohm 包括的ラマンライブラリ (MCRL) 農薬、NanoRam-1064 用。
66079520
NanoRam-1064 違法物質および一般化学薬品ライブラリNanoRam-1064 用の Metrohm 違法物質および一般化学薬品ラマンライブラリには、薬物、TIC、TIM、前駆物質、一般化学薬品が含まれています。
66079530
NanoRam-1064 包括的ラマンライブラリMetrohm 包括的ラマンライブラリは, 29,000 件以上もの化学薬品、鉱物、有機化合物、溶媒、ポリマー、染料および顔料、TIC、TIM、無機化合物および有機金属系、パーソナルケア製品、違法物質のスペクトルのエントリをカバーしています。NanoRam-1064 用。
6.6080.100
OpenLab CDS のための Metrohm IC Driver 1.0Agilent 社の「OpenLab CDS」(バージョン2.3、2.4、2.5、2.6、2.7および2.8) にMetrohm IC装置を接続するためのソフトウェアドライバー。コンピューター 1 台につき 1 つのライセンスにより、「OpenLab CDS」 におけるICシステムを稼働させる権限が与えられます。IC と質量分析計の結合についての詳細
6.6081.010
Eco Titrator用のUSBスティックEco Titrator用のデータ記憶媒体
6.6081.020
Eco KF Titrator用のUSBスティックEco KF Titrator用の保存デバイス
6.6081.030
Eco Coulometer 用USBスティックStorage medium for Eco Coulometer
6.6082.000
Portable VA Analyzer ソフトウェア 1.1PC program for the 946 Portable VA Analyzer. The range of functions of the software include instrument and measuring stand control, data acquisition and evaluation, calculation of results and generation of reports.Easy-to-operate method editor; Method templates for all important applications; Display of measurement and calibration curves and analysis result; Dialog languages: English, Chinese; Supplied on USB memory stick;
6.6090.100
Metrohm IC Driver 1.0、ICP-MS MassHunterSoftware drivers for integrating Metrohm IC instruments in Agilent's ICP-MS MassHunter Software 5.3 and higher.Learn more about the coupling of IC and mass spectrometers
BWT-810000044
BWSpec ソフトウェアBWSpec® は、リアルタイムによるピークとトレンドの分析を含む装置のコントロール、データ取得に適したB&W Tekの分光法ソフトウェアです。BWSpec は、あらゆるB&W Tek ポータブルラマンシステムおよびスペクトロメーター製品のご購入時に含まれる操作用ソフトウェアです。広範囲なアプリケーションのための機能を含み、ボタン 1 つで複雑な測定および計算を行ないます。複数のデータ型式に対応し、積分時間やレーザー出力コントロール等、測定パラメータを最適化するためのオプションが含まれています。データ取得およびデータ処理に加え、自動ダーク除去、スペクトルスムージング、ベースライン補正、ピークモニタリングおよびトレンド分析といった各種機能を提供しています。
BWT-840000126
BWID 標準ラマン ID ソフトウェアユーザーが作成したライブラリ、著作権で保護された B&W Tek のライブラリ、ならびに第三者プロバイダのライブラリに基づく材料の迅速な識別または検証を可能にする、B&W Tek 社製 携帯型ラマンスペクトロメーターのためのデータ記録、材料識別、およびレポート作成のためのソフトウェア。システムの性能検査を含みます。ユーザーライセンスを包括。購入日より1年間の無料アップグレードを含みます。
BWT-840000127
BWID Pharma ラマン ID ソフトウェアユーザーが作成したライブラリ、著作権で保護された B&W Tek のライブラリ、ならびに第三者プロバイダのライブラリに基づく材料の迅速な識別または検証を可能にする、B&W Tek 社製 携帯型ラマンスペクトロメーターのためのデータ記録、および材料識別のためのソフトウェア。アメリカ合衆国政府機関 FDA による 21 CFR Part 11 に準ずるすべての要件を、システムアクセスセキュリティ、データ活動監査証跡、ならびにシステムの性能検査も含めて満たしています。ユーザーライセンスを包括。購入日より1年間の無料アップグレードを含みます。
BWT-840000172
炭化水素のラマンスペクトルライブラリBWID ソフトウェアでの使用のための炭化水素のラマンスペクトルライブラリ (携帯型装置); 576のスペクトル。
BWT-840000280
ソフトウェア GemIDB&W Tek社製の携帯型ラマンスペクトロメーターを用いた宝石と鉱石の分析のためのデータ記録、同定ソフトウェア。GemExpertならびにJapan Germany Gemmological Laboratory(日独宝石研究所)からの、450以上の宝石のためのラマンスペクトルライブラリおよび画像を含みます。ユーザーライセンスを包括。購入日より1年間の無料アップグレードを含みます。
BWT-840000305
NanoRam IDソフトウェアNanoRamアカウントの管理、テスト結果のチェック、ならびにテストレポートへのアクセスと Audit Trail のためのPC用のNIDソフトウェア。
BWT-840000591
化学物質のラマンスペクトルライブラリ一般に流通する化学物質、麻酔薬、爆薬、溶媒、および合成物質の約1150のスペクトルを含む携帯型ラマン装置のための化学薬品のラマンスペクトルライブラリ。バージョン 2.02 以降のBWIDにてサポートされています。
BWT-840000843
宝石のラマンスペクトルライブラリGemExpertならびにJapan Germany Gemmological Laboratory(日独宝石研究所)からの450以上のスペクトルを含む BWID および携帯型ラマン装置のための宝石のラマンスペクトルライブラリ。バージョン 2.02 以降の BWID によってサポートされるライブラリです。
BWT-840000847
爆薬のラマンスペクトルライブラリ180以上のスペクトルを含む携帯型ラマン装置のための爆薬ラマンスペクトルライブラリ。バージョン 2.02 以降のBWIDにてサポートされています。注意: この商品は、一部の地域では輸出管理規制の対象となっています。
BWT-840000848
化学物質および麻酔薬のラマンスペクトルライブラリ一般に流通している有毒化学物質、麻酔薬、溶媒、および合成物質の1100以上のスペクトルを含む携帯型ラマン装置のための化学物質ラマンスペクトルライブラリ。バージョン 2.02 以降のBWIDにてサポートされています。
BWT-840000939
TID-EX ソフトウェアドライバーおよび製品ハンドブックTaticID-1064 PC ソフトウェア、TID-EX インストールパッケージ、ならびにTacticID-1064 Plus製品ハンドブックの入ったUSBスティック。
BWT-840000971
NanoRam-1064 ソフトウェアおよび製品ハンドブックNanoRam-1064 付属品: NID-EX ソフトウェアインストールパッケージ入りのUSBスティック、NanoRAM-1064 製品ハンドブック (PDF) および NID EX 設置ガイド (PDF)。
BWT-840000974
ラマンスペクトル完全ライブラリ (TacticID Plus)一般に流通している化学物質、麻酔薬、溶媒、および合成物質の10000以上のスペクトルを含む TacticID Plus のためのラマンスペクトル完全ライブラリ。NFPA704 および GHS の安全に関する注意事項を含む。
BWT-840000975
一般に流通する化学物質、麻酔薬、爆薬、溶媒、および合成物質のラマンスペクトルライブラリ (TacticID Plus)一般に流通している化学物質、麻酔薬、爆薬、溶媒、および合成物質の1200以上のスペクトルを含む TacticID Plus のためのラマンスペクトルライブラリ。NFPA704 および GHS の安全に関する注意事項を含む。輸出管理規制の対象となっていることがあります。
BWT-840000976
一般に流通する化学物質、麻酔薬、溶媒、および合成物質のラマンスペクトルライブラリ (TacticID Plus)一般に流通している化学物質、麻酔薬、溶媒、および合成物質の1180以上のスペクトルを含む TacticID Plus のためのラマンスペクトルライブラリ。NFPA704 および GHS の安全に関する注意事項を含む。
BWT-840000977
爆薬のラマンスペクトルライブラリ (TacticID Plus)180以上のスペクトルを含む TacticID Plus のための爆薬のラマンスペクトルライブラリ。NFPA704 および GHS の安全に関する注意事項を含む。注意: この商品は、一部の地域では輸出管理規制の対象となっています。
BWT-840000978
宝石のラマンスペクトルライブラリ (TacticID Plus)467 のスペクトルを含む TacticID Plus のための宝石のラマンスペクトルライブラリ。
BWT-840000979
化学兵器のラマンスペクトルライブラリ (TacticID Plus)TacticID Plus のための化学兵器のラマンスペクトルライブラリ。NFPA704 および GHS の安全に関する注意事項を含む。注意: この商品は、一部の地域では輸出管理規制の対象となっています。
BWT-840000981
TacticID PlusソフトウェアUSB flash drive containing TacticID Plus TID software for PC, TID installation package and TacticID Plus Product Manuals.
BWT-840001136
Vision Pharma 4.1Vision Pharma is data acquisition and method development software solution for spectroscopic analysis and control of B&W Tek portable Raman instruments, Metrohm XDS laboratory and process NIRS instruments. A user-friendly graphical analysis interface enables a simple application of chemometric algorithms for creating identification, qualification, and quantification methods and running them in real-time. With Vision you can store, manage, reprocess and exchange data. Vision Pharma is complies with the US FDA's 21 CFR Pt 11 regulations for electronic signatures and records.
BWT-840001137
Vision 4.1Vision is data acquisition and method development software solution for spectroscopic analysis and control of B&W Tek portable Raman instruments, Metrohm XDS laboratory and process NIRS instruments. A user-friendly graphical analysis interface enables a simple application of chemometric algorithms for creating identification, qualification, and quantification methods and running them in real-time. With Vision you can store, manage, reprocess and exchange data.
BWT-840001155
TID-1064のためのフェンタニル化合物のラマンスペクトルライブラリTacticID-1064およびTacticID-1064 STのためのフェンタニル化合物の拡張ラマンスペクトルライブラリTDL-EX-FEN
BWT-840001183
TacticID Mobileを含むラマンスペクトルライブラリ一般的な化学薬品、麻薬、爆発物、溶媒、およびプラスチックの1200を超えるスペクトルを含むラマンスペクトルライブラリ。NFPA704ならびにGHS安全情報を含みます。これは、TacticID Mobileを含む標準ライブラリですTDL-XM-CNESP
BWT-840001184
TacticID Mobileのための1000を超える化合物を含むラマンスペクトルライブラリ一般的な化学薬品、麻薬、溶媒、およびプラスチックの1000を超えるスペクトルを含むラマンスペクトルライブラリ。NFPA704ならびにGHS安全情報を含みます。TacticID Mobileを伴う使用向け。TDL-XM-CNSP
BWT-840001187
TacticID Mobileを伴う使用のためのフェンタニル化合物のラマンスペクトルライブラリTacticID Mobileのためのフェンタニル化合物の拡張ラマンスペクトルライブラリ。200を超えるフェンタニル関連のスペクトルを含みます。TDL-XM-FEN
BWT-840001188
TacticID Mobileを伴う使用のための12000を超えるラマンスペクトルライブラリ一般的な化学薬品、麻薬、溶媒、TIC、およびTIMなどの12000を超えるスペクトルを含むラマンスペクトルライブラリ。NFPA704ならびにGHS安全情報を含みます。TacticID Mobileと互換性があります。TDL-XM-TPJ
BWT-840001190
TacticID Mobile CWA ライブラリ化学兵器 (CWA) ライブラリ、TacticID Mobile 用。
BWT-840001226
TacticID Mobile 爆発物ライブラリTacticID Mobile 用の爆発物ライブラリ。
BWT-840001251
TacticID Illicit and General Chemicals LibraryTacticID N Plus 違法物質ライブラリには、薬物、TIC、TIM、前駆物質、一般化学薬品が含まれています。
BWT-840001252
TacticID Mobile Illicit and General Chemicals LibraryTacticID Mobile 違法物質ライブラリには、薬物、TIC、TIM、前駆物質、一般化学薬品が含まれています。
BWT-840001253
TacticID-1064/ST Illicit and General Chemicals LibraryTacticID-1064/ST 違法物質ライブラリには、薬物、TIC、TIM、前駆物質、一般化学薬品が含まれています。
BWT-840001254
BWID Illicit and General Chemicals LibraryBWID 違法物質ライブラリには、薬物、TIC、TIM、前駆物質、一般化学薬品が含まれています。
BWT-840001263
NanoRam-1064 Comprehensive USP ラマンライブラリMetrohm Comprehensive USP ラマンライブラリ、NanoRam-1064 用、追跡可能な認定物質を最大 900 品目までカバー。
BWT-840001266
TacticID Mobile Comprehensive ラマンライブラリTacticID Mobile Metrohm Comprehensive ラマンライブラリは、29'000 件以上もの化学薬品、鉱物、有機化合物、溶媒、ポリマー、染料および顔料、TIC、TIM、無機化合物および有機金属系、パーソナルケア製品、違法物質のスペクトルのエントリをカバーしています。TDL-XM-MCRL
BWT-840001294
TacticID Mobile MCRL - 有機物 & 有機金属Metrohm 包括的ラマンライブラリ (MCRL) 無機物および有機金属、TacticID Mobile 用。
BWT-840001298
TacticID Mobile MCRL - 有機物Metrohm 包括的ラマンライブラリ (MCRL) 有機物、TacticID Mobile 用。
BWT-840001302
TacticID Mobile MCRL - パーソナルケア製品Metrohm 包括的ラマンライブラリ (MCRL) パーソナルケア製品、TacticID Mobile 用。
BWT-840001306
TacticID Mobile MCRL - ポリマーおよびポリマー添加剤Metrohm 包括的ラマンライブラリ (MCRL) ポリマーおよびポリマー添加剤、TacticID Mobile 用。
BWT-840001310
TacticID Mobile MCRL - 染料、顔料、着色剤Metrohm 包括的ラマンライブラリ (MCRL) 染料、顔料、着色剤、TacticID Mobile 用。
BWT-840001319
TacticID Mobile MCRL 有機物 - ハロゲン化合物Metrohm Comprehensive ラマンライブラリ (MCRL) 有機物 - TacticID Mobile 用ハロゲン化合物。
BWT-840001320
TacticID Mobile MCRL 有機物 - 窒素含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 窒素含有基、TacticID Mobile 用。
BWT-840001321
TacticID Mobile MCRL 有機物 - 酸素含有基Metrohm Comprehensive ラマンライブラリ (MCRL) 有機物 - TacticID Mobile 用酸素含有基。
BWT-840001322
TacticID Mobile MCRL 有機物 - 硫黄含有基Metrohm 包括的ラマンライブラリ (MCRL) 有機物 - 硫黄含有基、TacticID Mobile 用。
BWT-840001323
TacticID Mobile 鉱物ライブラリMetrohm 鉱物ライブラリ、TacticID Mobile 用。
NOVA
Advanced software for electrochemical researchNOVA is the package designed to control all the Autolab instruments with USB interface.Designed by electrochemists for electrochemists and integrating over two decades of user experience and the latest .NET software technology, NOVA brings more power and more flexibility to your Autolab potentiostat/galvanostat.NOVA offers the following unique features:Powerful and flexible procedure editor; Clear overview of relevant real-time data; Powerful data analysis and plotting tools; Integrated control for external devices like Metrohm Liquid Handling devices; Download the latest version of NOVA
SDK
Software development kitThe Autolab Software Development Kit (Autolab SDK) is designed to control the Autolab instrument from different external applications such as LabVIEW, Visual Basic for Applications (VBA), scripting etc. With the Autolab SDK the external application can be used to measure complete procedures or control individual Autolab modules.In order to use the Autolab SDK from other applications, these applications must have the possibility to use .NET assemblies or in the case of 'older' applications to use COM assemblies. How to integrate these assemblies is explained in the manual of the application.The Autolab SDK is compatible with Autolab NOVA however it does not require NOVA to be installed.
6.0257.600
Pt1000付きAquatrode Plus低濃度イオンの水性溶媒 (例えば飲料水、プロセス水など) におけるpH測定/滴定のためのPt1000温度センサー内蔵の複合pH 電極、またこのようなサンプルにおいて著しく迅速な応答時間を示します。固定グランドジョイントダイアフラムは汚れに対して耐性があります。ブリッジ内部液として c(KCl) = 3 mol / L を使用する場合、保存液中での保存が推奨されます。ブリッジ内部液は、塩化物フリーの内部液 (例えば硝酸カリウム c(KNO3) = 1 mol/L (6.2310.010)) と交換することができ、使用する内部液にて保管します。
6.0258.010
Pt1000付きUnitrode (固定式ケーブル 1.2 m、2 mm)内蔵Pt1000温度センサーおよび固定式ケーブル (1.2 m、バナナプラグ直径 2 mm) 付き複合pH電極。これは、特に以下の用途に適しています:困難なサンプル、粘性のあるサンプル、またはアルカリ性のサンプルにおけるpH測定および滴定; 高温時; 長期測定; 固定グランドジョイントダイアフラムは汚れに対して耐性があります。参照内部液: c(KCl) = 3 mol/L、保存液で保存。代替: T>80°Cでの測定用参照内部液: イドロライト、イドロライトで保管。
6.0258.600
Pt1000付きUnitrodepH 電極/滴定のためのPt1000温度センサー内蔵の複合pH電極。これは、特に以下の用途に適しています:困難なサンプル、粘性のあるサンプル、またはアルカリ性のサンプルにおけるpH測定および滴定; 高温時; 長期測定; 固定グランドジョイントダイアフラムは汚れに対して耐性があります。参照内部液: c(KCl) = 3 mol/L、保存液で保存。代替: T>80°Cでの測定用参照内部液: イドロライト、イドロライトで保管。
6.0259.100
UnitrodepH滴定のための複合pH 電極。これは、特に以下の用途に適しています:困難なサンプル、粘性のあるサンプル、あるいはアルカリ性のサンプルにおけるpH滴定; 高温時; 固定グランドジョイントダイアフラムは汚れに対して耐性があります。参照内部液: c(KCl) = 3 mol / L、保存液で保管。代替: T>80°Cでの滴定用参照内部液: イドロライト、イドロライトで保管。
6.0260.010
Unitrode easyClean、Pt1000付き (固定式ケーブル1.2 m)easyCleanダイヤフラム、および内蔵Pt1000-温度センサー付きの複合pH 電極および固定式ケーブル (1.2 m)。特に適しているのは以下のとおりです:困難なサンプル、粘性のあるサンプル、またはアルカリ性のサンプルでのpH測定および滴定; 高温時; 長期測定; easyCleanダイアフラムは、強度な汚れのサンプルの場合でも簡単に洗浄することができます。参照内部液: c(KCl) = 3 mol/L、保存液で保存。代替: T>80°Cでの測定用参照内部液: イドロライト、イドロライトで保管。Pt1000付きUnitrode easyCleanについては、製品番号6.0260.020の固定ケーブル長2.0mも入手可能です。
6.0260.020
Unitrode easyClean、Pt1000付き (固定式ケーブル 2 m)easyCleanダイアフラム、および内蔵Pt1000温度センサー付きの複合pH 電極および固定式ケーブル (2.0 m)。これは、特に以下の用途に適しています:困難なサンプル、粘性のあるサンプル、またはアルカリ性のサンプルにおける自動化されたpH測定および滴定; 高温時; 長期測定; easyCleanダイアフラムは、強度な汚れのサンプルの場合でも簡単に洗浄することができます。参照内部液: c(KCl) = 3 mol / L、保存液で保管。代替: T>80°Cでの測定用参照内部液: イドロライト、イドロライトで保管。
6.0262.100
Ecotrode plus水性酸/塩基滴定のための複合pH 電極。固定グランドジョイントダイアフラムは汚れに対して耐性があります。参照内部液: c(KCl) = 3 mol/L、保存液で保管。
6.0269.100
EtOH-Trode非水媒質における pH 測定 (例えばエタノール中の pH eなど) のためのダブルジャンクションシステムを備えた複合 pH 電極。電極は、汚れに耐性のある固定グランドジョイントダイアフラムを装備しており、塩橋は自由に選択することができます (水性または非水性)。塩橋として c(KCl) = 3 mol/L を使用する場合、保存液中での保存が推奨されます。その他の塩橋を使用する場合、使用するそれぞれの電解液中での保存が推奨されます。出荷時、参照内部液 ("INNER FILLING") と塩橋 ("OUTER FILLING") 用の両方のチャンバには、c(KCl) = 3 mol/l が充填されています。
6.0277.300
Pt1000付きiAquatrode Plus低濃度イオンの水性溶媒 (例えば飲料水、プロセス水など) におけるpH測定/滴定のためのセンサーデータのメモリーチップおよびPt1000温度センサーが内蔵されたインテリジェントな複合pH電極。この電極は、これらのサンプルにおいて非常に速い応答時間を有します。固定グランドジョイントダイアフラムは汚れに対して耐性があります。ブリッジ内部液としてc(KCl) = 3 mol / Lを使用する場合、保存液中での保存が推奨されます。ブリッジ内部液は、塩化物フリーの内部液 (例えば、硝酸カリウム c(KNO3) = 1 mol/L (6.2310.010)) と交換することができます。使用される内部液にて保管します。iTrodeはTitrando、Ti-Touch、または913/914 メーターにて使用することが可能です。
6.0278.300
Pt1000付きiUnitrodeセンサーデータのメモリーチップおよびPt1000温度センサーが内蔵されたインテリジェントな複合pH電極。この電極は、特に以下の用途に適しています:困難なサンプル、粘性のあるサンプル、またはアルカリ性のサンプルにおけるpH測定および滴定; 高温時; 長期測定; 固定グランドジョイントダイアフラムは汚れに対して耐性があります。参照内部液: c(KCl) = 3 mol/L、保存液で保存。代替: T>80°Cでの測定用参照内部液: イドロライト、イドロライトで保管。iTrodeはTitrando、Ti-Touch、またはは913/914 メーターにて使用することが可能です。
6.0279.300
iSolvotrodeあらゆる酸/塩基の非水滴定のためのセンサーデータのメモリーチップが内蔵されたインテリジェントな複合pH 電極。ガラスメンブランは導電性の低い溶液のために最適化されており、フレキシブルなグランドジョイントダイアフラムにより、この電極は汚れの酷いサンプルにも適しています。電極は、非水性参照内部液 (塩化リチウムまたはTEABr) と共に用いることができます。適切な参照内部液にて保管します。iTrodeはTitrando、Ti-Touch、または913/914 メーターにて使用することが可能です。
6.0280.300
iEcotrode Plusセンサーデータのメモリーチップが内蔵されたインテリジェントな複合pH電極。この電極は、水性酸/塩基滴定に適しています。固定グランドジョイントダイアフラムは汚れに対して耐性があります。参照内部液: c(KCl) = 3 mol / L、保存溶液にて保管します。iTrodeはTitrando、Ti-Touch、または913/914 メーターにて使用することが可能です。
6.0301.100
分離Ptワイヤ電極Ptワイヤ製の電極チップ。この電極は微分電位差のAEとして用いられます。
6.0309.100
ダブルPtシート電極酸化還元滴定のために分極化されるプラチナシート(0.15 x 8 x 8 mm)を2つ伴うガラスシャフト電極(バイボルタンメトリー滴定)。この電極は以下の用途に非常に良く適しています: ビタミンCの測定; 窒素の電量測定; 臭素指数; ワインに含まれる亜硫酸 (SO2); Winkler(ウィンクラー)法による酸素含有量;
6.0331.000
分離Ptロッド電極このメタル電極は参照電極 (参照電解質としてのc(KCl) = 3 mol/ L) と一緒に使用しなければならず、以下の用途に適しています: 酸化還元滴定のため; 微分電位差のAEとして; ポリプロピレン製の頑丈なシャフトおよびメタルロッドは、個々に交換することができます。
6.0331.010
分離Agロッド電極このメタル電極は参照電極 (参照電解質としてのc(KNO3) = 1 mol/ L) と一緒に使用しなければならず、沈殿滴定 (滴定試薬硝酸銀) に適しています。ポリプロピレン製の頑丈なシャフト、およびメタルロッドは、個々に交換することができます。
6.0331.010BR
AgBrコーティング付きの分離Agロッド電極このメタル電極は参照電極 (参照電解質としてのc(KNO3) = 1 mol/ L) と一緒に使用しなければならず、沈殿滴定 (滴定試薬硝酸銀) に適しています。ポリプロピレン製の頑丈なシャフトおよびメタルロッドは、個々に交換することができます。銀ロッドは、感度を高めるため臭化物のコーティング(AgBr)が施されています。
6.0331.010S
Ag2Sコーティングされた分離Agロッド電極このメタル電極は参照電極 (参照電解質としてのc(KNO3) = 1 mol/ L) と一緒に使用しなければならず、沈殿滴定 (滴定試薬硝酸銀) に適しています。ポリプロピレン製の頑丈なシャフト、およびメタルロッドは、個々に交換することができます。銀ロッドは、感度を高めるため硫化物のコーティング(Ag2S)が施されています。
6.0338.100
容量滴定用ダブルPtワイヤ電極カール フィッシャー容量滴定に用いられる指示電極。
6.0340.000
サンプルチェンジャー用ダブルPtワイヤ電極 (固定式ケーブル)自動カール フィッシャー滴定に用いられる指示電極 (直径 = 5.3 mm、固定式ケーブル 2 m)。
6.0341.100
クーロメトリー用ダブルPtワイヤ電極カール フィッシャー電量滴定に用いられる指示電極。
6.0343.100
分離Ptロッド電極電圧電流法およびCVSのための白銀AE。
6.0343.110
分離スチール電極CVS のための スチール製AE
6.0344.100
発生電極(2液型電極付き)カール フィッシャー電量滴定用の発生電極(2液型電極付き)、すり合わせ 29/22。この発生電極は特に以下の用途に適しています: 絶対水分 < 50 ppm の非常に低いサンプル; オイルサンプルにおける電量法水分測定; ケトン試薬を用いる用途; 低導電性試薬が用いられる用途 (クロロホルム、キシレンの追加 >10%);
6.0345.100
発生電極(1液型電極付き)カール フィッシャー電量滴定用の発生電極(1液型電極付き)、すり合わせ 29/22。この発生電極は、サンプルがアルコールによく溶解するアプリケーションのほとんどに適しています。
6.0346.000
ビスマス滴電極水サンプル中の微量の金属イオンをボルタンメトリー測定するためのビスマス滴電極。これは作用電極(WE)として 884 Professional VA に用いることができます。
6.0351.100
分離Ptリング電極この白金リング電極は参照電極 (参照電解質としてのc(KCl) = 3 mol/ L) と一緒に使用しなければならず、以下の用途に適しています: ヨウ素滴定またはセリウム滴定のような酸化還元滴定; 微分電位差のAE;
6.0352.100
分離Auリング電極この金リング電極は参照電極 (参照電解質としてのc(KCl) = 3 mol/ L) と一緒に使用しなければならず、例えば以下のような酸化還元滴定に適しています: Hg(NO3)2による滴定; クロムまたは鉄が存在する滴定;
6.0421.100
アンチモン複合電極Sb複合電極。この電極は、以下のマトリックスにおけるpH滴定に最も適しています: フッ化水素酸を含むマトリックス; 吸湿性の高いマトリックス ; 頑丈で耐破損性のPP製プラスチックシャフトにより、機械的に非常に耐性の高い電極となっています。
6.0430.100
Ag Titrode参照電極としての、pHガラスメンブランを含む複合銀リング電極。このメンテナンスフリーの電極は、例えば以下のような一定したpH値 (滴定試薬硝酸塩) での沈殿滴定に適しています: 塩化物、臭化物、ヨウ化物; 硫化物; 硫化水素; メルカプタン; シアン化物; この電極は蒸留水で保管されます。用途に応じて、注文可能な、コーティングされた (AgBr、AgClまたはAg2Sコーティング) Ag Titrodeの使用を推奨しています。
6.0430.100S
硫化物コーティング付きAg Titrode参照電極としての、pHガラスメンブランを含む複合銀リング電極。シルバーリングは、感度を高めるため、またより優れた検出限界のために硫化物 (Ag2S) でコーティングされています。このメンテナンスフリーの電極は、例えば以下のような一定したpH値 (滴定試薬硝酸塩) での沈殿滴定に適しています: 塩化物、臭化物、ヨウ化物; 硫化物; 硫化水素; メルカプタン; シアン化物; この電極は蒸留水で保管されます。
6.0431.100
Pt-Titrode参照電極としての、pHガラスメンブランを含む複合白金リング電極。このメンテナンスフリーの電極は、例えば以下のような一定したpH値での酸化還元滴定に適しています: ヨウ素滴定; クロム酸滴定; セリウム滴定; 過マンガン酸塩滴定; この電極は蒸留水で保管されます。
6.0433.110
マイクロAg Titrode参照電極としてpHガラスメンブランを含む複合銀リング電極、直径6.4mmに先細りになっています。このメンテナンスフリーの電極は、例えば以下のような一定したpH値 (滴定試薬硝酸塩) での沈殿滴定に適しています: 塩化物、臭化物、ヨウ化物; 硫化物; 硫化水素; メルカプタン; シアン化物; この電極は蒸留水で保管されます。用途に応じて、注文可能なAg2Sコーティングの施されたAg Titrodeの使用を推奨しています。
6.0434.110
マイクロPt Titrode (取り付け長さ 17.8 cm)参照電極としての、pHガラスメンブランを含む複合白金リング電極、取り付け長さ = 17.8 cm、直径 6.4 mmに先細りになっています。このメンテナンスフリーの電極は、例えば以下のような一定したpH値での酸化還元滴定に適しています: ヨウ素滴定; クロム酸滴定; セリウム滴定; 過マンガン酸塩滴定; この電極は蒸留水で保管されます。
6.0435.110
マイクロAu Titrode (取り付け長さ 17.8 cm)参照電極としての、pHガラスメンブランを含む複合金リング電極、取り付け長さ = 17.8 cm、直径 6.4 mmに先細りになっています。このメンテナンスフリーの電極は、例えば以下のような一定したpH値での酸化還元滴定に適しています: 化学的酸素要求量(COD、鉄(II)滴定)の測定; ペニシリンおよびアンピシリンの測定; Hg(NO3)2による滴定; クロムまたは鉄が存在する滴定; この電極は蒸留水で保管されます。
6.0450.100
複合Agリング電極セラミックピンダイアフラム付き複合銀リング電極。この電極は、例えば以下のような様々なpH値 (滴定試薬硝酸塩) での沈殿滴定に適しています: 塩化物、臭化物、ヨウ化物; 硫化物; 硫化水素; メルカプタン; シアン化物; 参照電解質として、および保管用にc(KNO3) = 1 mol/Lが使用されます。用途に応じて、注文可能な、コーティングされた (AgBrまたはAg2Sコーティング) Ag Titrodeの使用を推奨しています。
6.0450.300
複合 iAg リング電極センサーデータのためのメモリーチップが内蔵された、インテリジェントな複合銀リング電極。この電極は、例えば以下のような、様々な pH 値 (滴定試薬硝酸銀) での沈殿滴定に適しています: 塩化物、臭化物、ヨウ化物; 硫化物; 硫化水素; メルカプタン; シアン化物; c(KNO3) = 1 mol/L は参照内部液として、そして保管用に使用されます。iTrode は、Titrando か Ti-Touch、または 913/914メーターにて使用できます。
6.0451.100
複合Pt リング電極セラミックピンダイアフラム付き複合白金リング電極。この電極は、例えば以下のような様々なpH値での酸化還元滴定に適しています: Winkler(ウィンクラー)法による酸素含有量; KMnO4を用いた過酸化水素の測定; ジアゾ化滴定; 参照電解質として、および保管用にc(KCl) = 3 mol/Lが使用されます。
6.0451.300
複合 iPt リング電極センサーデータ用のメモリーチップが内蔵された、インテリジェントな複合白金リング電極。この電極は、例えば以下のような様々な pH 値での酸化還元滴定に適しています: Winkler(ウィンクラー)法による酸素含有量; KMnO4 を用いた過酸化水素の測定; ジアゾ化滴定; c(KCl) = 3 mol/L は参照内部液として、そして保管用に使用されます。iTrode は、Titrando か Ti-Touch、または 913/914メーターにて使用できます。
6.0452.100
複合Au リング電極セラミックピンダイアフラム付き複合金リング電極。この電極は、例えば以下のような様々なpH値での酸化還元滴定に適しています: Hg(NO3)2による滴定; クロムまたは鉄が存在する滴定; 参照電解質として、および保管用にc(KCl) = 3 mol/Lが使用されます。
6.0470.300
iAg-Titrode参照電極としての pH ガラスメンブランを備え、センサーデータ用のメモリーチップが内蔵された、インテリジェントな複合銀リング電極。このメンテナンスフリーの電極は、例えば以下のような、一定した pH 値 (滴定試薬硝酸銀) での沈殿滴定に適しています: 塩化物、臭化物、ヨウ化物; 硫化物; 硫化水素; メルカプタン; シアン化物; この電極は蒸留水で保管されます。用途に応じて適宜注文可能な、コーティングされた (AgBr- または Ag2S コーティング) Ag Titrode の使用が推奨されます。iTrodes は、Titrando、Ti-Touch、または 913/914 メーターにて使用できます。
6.0470.300S
Ag2S コーティング付き iAg Titrode参照電極としての pH ガラスメンブランを備え、センサーデータ用のメモリーチップが内蔵された、インテリジェントな複合銀リング電極。シルバーリングは、感度を高めるため、またより優れた検出限界のために硫化物 (Ag2S) でコーティングされています。このメンテナンスフリーの電極は、例えば以下のような、一定した pH 値 (滴定試薬硝酸銀) での沈殿滴定に適しています: 塩化物、臭化物、ヨウ化物; 硫化物; 硫化水素; メルカプタン; シアン化物; この電極は蒸留水で保管されます。iTrode は、Titrando か Ti-Touch、または 913/914 メーターにて使用できます。
6.0471.300
iPt-Titrode参照電極として pH ガラスメンブランを備え、センサーデータ用のメモリーチップが内蔵された、インテリジェントな複合白金リング電極。このメンテナンスフリーの電極は、例えば以下のような、一定した pH 値での酸化還元滴定に適しています: ヨウ素滴定; クロム酸滴定; セリウム滴定; 過マンガン酸塩滴定; この電極は蒸留水で保管されます。iTrode は、Titrando か Ti-Touch、または 913/914 メーターにて使用できます。
6.0501.100
ナトリウム選択性ガラス電極ナトリウム選択性皮膜ガラスおよびすり合わせを有するガラス電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています: Na+ (10-5~1 mol/L) のイオン測定; 滴定; この電極は、果汁・野菜飲料のような困難なマトリックス、塩素酸塩または過塩素酸塩を含むサンプルに適しています。
6.0502.100
イオン選択性電極、Br結晶皮膜を有する臭化物選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:Br- (5*10-6~1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 滴定; 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。同梱の研磨セットにより、電極表面の洗浄および再生が簡単になります。
6.0502.120
イオン選択性電極、Cl結晶皮膜を有する塩化物選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:Cl- (5*10-5~1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 滴定; 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。同梱の研磨セットにより、電極表面の洗浄および再生が簡単になります。
6.0502.130
イオン選択性電極、CN結晶皮膜を有するシアン化物選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:CN- (8*10-6~10-2 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 滴定; 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。同梱の研磨セットにより、電極表面の洗浄および再生が簡単になります。
6.0502.140
イオン選択性電極、Cu結晶皮膜を有する銅選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:Cu2+ (10-8~0.1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); CuEDTAを用いた錯滴定; 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。同梱の研磨セットにより、電極表面の洗浄および再生が簡単になります。
6.0502.150
イオン選択性電極、F結晶皮膜を有するフッ化物選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:F- (10-6mol/Lから飽和点まで) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 滴定; 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。
6.0502.160
イオン選択性電極、I結晶皮膜を有するヨウ化物選択性電極:このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:I- (5*10-8~1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 滴定; 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。同梱の研磨セットにより、電極表面の洗浄および再生が簡単になります。
6.0502.170
イオン選択性電極、Pb結晶皮膜を有する鉛選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:Pb2+ (10-6~0.1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 滴定 (例えば硝酸鉛を用いた硫酸の測定のためなど); 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。同梱の研磨セットにより、電極表面の洗浄および再生が簡単になります。
6.0502.180
イオン選択性電極、Ag/S結晶皮膜を有する銀および硫化物選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています:Ag+ (10-7~1 mol/L) のイオン測定; S2- (10-7~1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 滴定; 頑丈で耐破損性のEP製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。同梱の研磨セットにより、電極表面の洗浄および再生が簡単になります。
6.0506.100
NH3選択性ガス皮膜電極 (低濃度)10-2 mol/Lの低濃度のためのアンモニア選択性複合ガス皮膜電極、例えば: 飲料水中; ボイラー給水中; ミネラルウォーター中; 皮膜モジュール全体は、必要に応じて簡単に交換することができます。これらは個々に試験、認証されます。
NH3選択性ガス皮膜電極 (高濃度)
10-4 mol/Lより高い濃度のためのアンモニア選択性複合ガス皮膜電極、例えば 廃水中; 油分を含むサンプル中; 長時間の測定において; 汚れた皮膜は、低コストで個別に交換することができます。
6.0507.010
NIO界面活性剤電極この界面活性剤電極は参照電極と組み合わせて使用しなければならず、以下のような用途に適しています: 水性マトリックスにおける非イオン界面活性剤の滴定; ポリオキシエチレン付加物を基盤とした界面活性剤の滴定; テトラフェニルホウ酸ナトリウムによる原薬の滴定;
6.0507.120
イオン界面活性剤電極この界面活性剤電極は参照電極と組み合わせて使用しなければならず、以下のような用途に適しています: 水性マトリックスにおける陰イオン界面活性剤の滴定; 水性マトリックスにおける陽イオン界面活性剤の滴定; 電極は、皮膜に固定されたイオノフォア(イオン透過担体)により、優れた応答挙動を示します。
6.0507.130
Surfactrode Resistantこの界面活性剤電極は参照電極と組み合わせて使用しなければなりません。この長寿命の界面活性剤電極は、陰イオンおよび陽イオン界面活性剤の測定に使用することができ、また洗浄が容易です。電極は以下の用途に適しています: 非水性マトリックスでの界面活性剤の滴定 (クロロホルムを含む); 二相滴定 (pH 10); 冷却潤滑剤、穿孔油、切削油、油分を含むシャワージェルなどの困難なサンプル;
6.0507.140
Surfactrode Refillこの界面活性剤電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています: 非水系マトリックスでのイオン性界面活性剤の滴定 (クロロホルムは不可); 二相滴定 (pH > 10); 再生可能な電極表面のお陰で、この電極の寿命にはほぼ制限がなく、主に洗剤または石鹸などのサンプルのために用いられます。
6.0507.150
陽イオン界面活性剤電極この界面活性剤電極は参照電極と組み合わせて使用しなければならず、以下のような用途に適しています: 水性マトリックスにおける陰イオン界面活性剤の滴定; 水性マトリックスにおける陽イオン界面活性剤の滴定; 電極は、皮膜に固定されたイオノフォア(イオン透過担体)により、優れた応答挙動を示し、陽イオン界面活性剤に最適化されています。
6.0508.100
分離ポリマー皮膜電極、Naポリマー皮膜を有するナトリウム選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています: 水性溶液におけるNa+ (10-6~1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 水性溶液での滴定; 頑丈で耐破損性のPVC製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。
6.0508.110
分離ポリマー皮膜電極、Caポリマー皮膜を有するカルシウム選択性電極。このイオン選択性電極は参照電極と組み合わせて使用しなければならず、以下の用途に適しています: 水性溶液におけるCa2+ (5*10-7~1 mol/L) のイオン測定; ごく少量のサンプルでのイオン測定 (最小浸漬深度 1 mm); 錯(逆)滴定 (例えば水の硬度の測定など); 頑丈で耐破損性のPVC製プラスチックシャフトにより、これは機械的に非常に耐性の高いセンサーとなっています。
6.0510.100
複合ポリマー皮膜電極、Caポリマー皮膜を有するカルシウム選択性複合電極。このイオン選択性電極は以下の用途に適しています: 水性溶液におけるCa2+ (5*10-7~1 mol/L) のイオン測定; 錯(逆)滴定 (たとえば水の硬度の測定など) ; 頑丈で耐破損性のポリプロピレン製合成樹脂シャフト、および高分子膜のための衝撃保護により、これは機械的に非常に耐性の高いセンサーとなっています。参照電解質としては、c(NH4NO3) = 1 mol/L で使用されます。
6.0510.110
複合ポリマー皮膜電極、Kポリマー皮膜を有する複合カリウム選択性電極。このイオン選択性電極は以下の用途に適しています: 水性溶液におけるK+ (10-7~1 mol/L) のイオン測定; 水性溶液での滴定; 頑丈で耐破損性のポリプロピレン製合成樹脂シャフト、および高分子膜のための衝撃保護により、これは機械的に非常に耐性の高いセンサーとなっています。参照電解質としては、c(CH3COOLi) = 1 mol/L で使用されます。
6.0724.140
Ag/AgCl参照システムPTFE (6.1240.000) またはガラス (6.1240.020) 製の参照電解質容器と組み合わされたモジュール式参照システムのためのすり合わせ14/15を有する銀/塩化銀参照システム。
6.0726.100
Ag/AgCl参照電極 (長さ 12.5 cm)ダブルジャンクションシステムを備えた銀/塩化銀参照電極、取り付け長さ10 cm。すり合わせ14/15により簡単に取り付けることができ、また、汚れに耐性のあるフレキシブルなグランドジョイントダイアフラムといつでも取り換えることが可能です。参照電解質およびブリッジ電解質は、用途に応じて自由に選択でき、また容易に交換することができます。このセンサーは、電解質充填なしで納品されます。
6.0726.107
Ag/AgCl参照電極(KCl) (長さ 12.5 cm)ダブルジャンクションシステムを備えた銀/塩化銀参照電極、取り付け長さ10 cm。すり合わせ14/15により簡単に取り付けることができ、また、汚れに耐性のあるフレキシブルなグランドジョイントダイアフラムといつでも取り換えることが可能です。参照電解質およびブリッジ電解質は、用途に応じて自由に選択でき、また容易に交換することができます。このセンサーには、参照電解質およびブリッジ電解質としてc(KCl) = 3 mol/Lが事前に充填されています。
6.0726.110
Ag/AgCl参照電極 (長さ 16.2 cm)ダブルジャンクションシステムを備えた銀/塩化銀参照電極、取り付け長さ13.8 cm。この参照電極は、自動化されたアプリケーションに非常に良く適しています。すり合わせ14/15により簡単に取り付けることができ、また、汚れに耐性のあるフレキシブルなグランドジョイントダイアフラムといつでも取り換えることが可能です。参照電解質およびブリッジ電解質は、用途に応じて自由に選択でき、また容易に交換することができます。このセンサーは、電解質充填なしで納品されます。
6.0728.000
電解液無しの Ag/AgCl 参照電極ガラス製電解液容器 6.1245.000 を伴う使用のための内部参照システム、電解液なし、端子ねじ付き。
6.0728.100
電解液無しの Ag/AgCl 参照電極内部参照システム、電解液なし、プラグコンタクト 5.5 mm 付き、ガラス製電解液容器 6.1245.000 を伴う使用向け。
6.0728.110
電解液無しの Ag/AgCl 参照電極内部参照システム、電解液なし、プラグコンタクト 5.5 mm 付き、プラスチック製電解液容器 6.1245.010 を伴う使用向け。
6.0728.120
Ag/AgCl参照電極c(KCl) = 3 mol/Lの内部液付き内部参照システム。プラスチック製内部液容器 6.1245.010 を伴う使用のため。
6.0728.130
CVSのためのLL-Ag/AgCl参照電極c(KCl) = 3 mol/Lの内部液付き内部参照システム。プラスチック製内部液容器 6.1245.010 を伴う使用のため。
6.0729.100
Ag/AgCl 参照電極 (長さ 12.5 cm)個別に保護され、かつダブルジャンクションシステムを備えた銀/塩化銀参照電極、取り付け長さ 10 cm。この参照電極は以下の用途に非常に良く適しています:非水系サンプル; 微分電位差; すり合わせ 14/15 により簡単に取り付けることができ、また、汚れに耐性のあるフレキシブルなグランドジョイントダイアフラムといつでも取り換えることが可能です。参照電解質および塩橋は、用途に応じて自由に選択でき、また容易に交換することができます。センサーは、電解質充填なしで納品されます。
6.0729.110
Ag/AgCl 参照電極 (長さ 16.2 cm)個別に保護され、かつダブルジャンクションシステムを備えた銀/塩化銀参照電極、取り付け長さ 13.8 cm。この参照電極は以下の用途に非常に良く適しています:自動アプリケーション; 非水系サンプル; 微分電位差; すり合わせ 14/15 により簡単に取り付けることができ、また、汚れに耐性のあるフレキシブルなグランドジョイントダイアフラムといつでも取り換えることが可能です。参照電解質および塩橋は、用途に応じて自由に選択でき、また容易に交換することができます。センサーは、電解質充填なしで納品されます。
6.0730.100
完全なLL Ag/AgCl(ゲル) 参照電極電圧電流法用のメンテナンスフリーのダブルジャンクションAg/AgCl参照電極。ガラス製、c(KCl) = 3 mol/L (ゲル) の内部液付き、pH値0~8。自動化システムおよびオンライン装置での連続運転における使用に適しています。
6.0733.100
Ag/AgCl参照電極参照電解質としてc(KCl) = 3 mol/Lを含む銀/塩化銀参照電極。この参照電極は水性アプリケーションに適しており、すり合わせ14/15により、取り付けが簡単です。
6.0736.110
Ag/AgCl参照電極 (長さ 18.5 cm)銀/塩化銀参照電極、取り付け長さ16.8 cm。この参照電極は、自動アプリケーションに非常に良く適しています。汚れに耐性のあるフレキシブルなグランドジョイントダイアフラムといつでも取り換えることが可能です。参照電解質としては、c(KCl) = 3 mol/L が推奨されます。このセンサーは、電解質充填なしで納品されます。
6.0750.100
LL ISE 参照電極ダブルジャンクションシステムを備えた銀/塩化銀参照電極。この参照電極は以下の用途に非常に良く適しています:自動アプリケーション; イオン測定; 界面活性剤滴定; 汚れに耐性のあるグランドジョイントダイアフラムにより、再現性のある一定した電解質流出が得られます。加えて、より優れた信号安定性のため、参照電解質がゲル化します。センサーはブリッジ電解質としてc(KCl) = 3 mol/Lが充填されて納品されますが、これは用途に応じて自由に選択し、交換することができます。
6.0901.040
電気伝導度測定セル c = 0.1 cm-1 (固定式ケーブル)セル定数c = 0.1 cm-1の電気伝導度測定セル、内蔵温度センサーなし、固定式ケーブル付き (2 x B (4 mm))。このセンサーは、脱イオン水などでの低い電気伝導度 (0.1 µS/cm から 10 mS/cm) の測定に適しています。センサーは、856 Conductivity Moduleにてアダプターボックス (6.2103.160) と共に用いることができます。
6.0901.260
電気伝導度測定セル c = 10 cm-1 (固定式ケーブル)セル定数c = 10 cm-1の電気伝導度測定セル、内蔵温度センサーなし、固定式ケーブル付き (2 x B (4 mm))。このセンサーは、以下のような液体などにおける非常に高い電気伝導度 (1 S/cmまで) の測定に適しています: 海水; 洗浄水; 生理溶液; センサーは、856 Conductivity Moduleにてアダプターボックス (6.2103.160) と共に用いることができます。
6.0908.110
電気伝導度測定セル c = 0.8cm-1Pt100付き (固定式ケーブル)セル定数c = 0.8 cm-1の電気伝導度測定セル、内蔵Pt100温度センサーおよび固定式ケーブル付き (4x B (4 mm))。このセンサーは、以下のような液体などにおける中程度の電気伝導度 (1 S/cmから100 mS/cm) の測定に適しています: 飲料水; 表面水; 廃水;
6.0910.120
電気伝導度測定セル c = 0.9 cm-1セル定数c = 0.9 cm-1の電気伝導度測定セル、内蔵温度センサーなし。このセンサーは、以下のような液体などにおける中程度の電気伝導度 (1 µS/cmから100 mS/cm) の測定に適しています: 飲料水; 表面水; 廃水; このセンサーは、サンプルチェンジャーでの使用に適しています (すり合わせ 14/15を含む)。
6.0912.110
電気伝導度測定セル c = 0.8cm-1Pt1000付き (固定式ケーブル)セル定数c = 0.8 cm-1の電気伝導度測定セル、内蔵Pt1000温度センサーおよび固定式ケーブル付き (4x B (4 mm))。頑丈かつ耐破損性に優れたPP製のプラスチックシャフトおよび衝撃保護により、このセンサーは機械的に非常に耐性が高く、以下のような液体などにおける中程度の電気伝導度 (1 µS/cm から 100 mS/cm) の測定に適しています: 飲料水; 表面水; 廃水; センサーは、856 Conductivity Moduleにてアダプターボックス (6.2103.160) と共に用いることができます。
6.0913.130
Measuring vessel cover for stability measuring instrumentsWith built-in conductometric measuring cell.
6.0914.040
電気伝導度測定セル c = 0.1cm-1Pt1000付き (固定式ケーブル)セル定数c = 0.1 cm-1のステンレス製電気伝導度測定セル、内蔵Pt1000温度センサーおよび固定式ケーブル付き (4x B (4 mm))。このセンサーは、脱イオン水などでの低い電気伝導度 (0 から 300 mS/cm) の測定、またはUSP 645>に則した測定に適しています。センサーは、856 Conductivity Moduleにてアダプターボックス (6.2103.160) と共に用いることができます。
6.0915.100
5リング電気伝導度測定セル c = 0.7cm-1Pt1000付き (固定式ケーブル)セル定数c = 0.7 cm-1 (指針値)の5リング電気伝導度測定セル、内蔵Pt1000温度センサーおよび856 Conductivity Moduleとの接続のための固定式ケーブル (1.2 m) 付き。このセンサーは、以下のような液体などにおける中程度の電気伝導度 (5 µS/cmから20 mS/cm) の測定に適しています:飲料水; 表面水; 廃水;
6.0915.130
5リング電気伝導度測定セル c = 1.0cm-1Pt1000付き (固定式ケーブル)セル定数c = 1.0 cm-1 (指針値)の5リング電気伝導度測定セル、内蔵Pt1000温度センサーおよび856 Conductivity Moduleとの接続のための固定式ケーブル (1.2 m) 付き。このセンサーは、以下のような液体などにおける中程度の電気伝導度 (5 µS/cmから100 mS/cm) の測定に適しています:飲料水; 表面水; 廃水;
6.0916.040
電気伝導度測定セル c = 0.1cm-1Pt1000付き (固定式ケーブル)セル定数c = 0.1 cm-1 (指針値)のステンレス製電気伝導度測定セル、内蔵Pt1000温度センサーおよび856 Conductivity Moduleとの接続のための固定式ケーブル (1.2 m) 付き。このセンサーは、脱イオン水などでの低い電気伝導度 (0 から 300 µS/cm) の測定、またはUSP 645>に則した測定に適しています。
6.0917.080
電気伝導度測定セル c = 0.5cm-1Pt1000付き (固定式ケーブル)セル定数c = 0.5 cm-1 (指針値)の4導体電気伝導度測定セル、内蔵Pt1000温度センサーおよび912/914メーターへの接続のための固定式ケーブル付き。頑丈かつ耐破損性に優れたPEEK製のプラスチックシャフトにより、このセンサーは機械的に非常に耐性が高く、以下の液体などにおける中程度の電気伝導度 (15 µS/cm から 250 mS/cm) の測定に適しています:飲料水; 表面水; 廃水;
6.0918.040
電気伝導度測定セル c = 0.1cm-1Pt1000付き (固定式ケーブル)セル定数c = 0.1 cm-1 (指針値) のステンレス製電気伝導度測定セル、内蔵Pt1000温度センサーおよび912/914メーターとの接続のための固定式ケーブル付き。このセンサーは、脱イオン水などでの低い電気伝導度 (0 から 300 µS/cm) の測定に適しています。
6.0919.140
電気伝導度測定セル c = 1.6cm-1Pt1000付き (固定式ケーブル)セル定数c = 1.6 cm-1 (指針値)の3導体電気伝導度測定セル、内蔵Pt1000温度センサーおよび912/914メーターへの接続のための固定式ケーブル付き。このセンサーは、以下のような液体などにおける高い電気伝導度 (0.1から1000 mS/cm) の測定に適しています:海水; 洗浄水; 生理溶液;
6.0920.100
5リング電気伝導度測定セル c = 0.7cm-1Pt1000付き (固定式ケーブル 2 m)セル定数c = 0.7 cm-1 (指針値)の5リング電気伝導度測定セル、内蔵Pt1000温度センサーおよびサンプルチェンジャーと組み合わせた856 Conductivity Moduleとの接続のための固定式ケーブル (2.0 m) 付き。このセンサーは、以下のような液体などにおける中程度の電気伝導度 (5 µS/cmから20 mS/cm) の自動測定に適しています:飲料水; 表面水; 廃水;
6.0920.130
5リング電気伝導度測定セル c = 1.0cm-1Pt1000付き (固定式ケーブル 2 m)セル定数c = 1.0 cm-1 (指針値)の5リング電気伝導度測定セル、内蔵Pt1000温度センサーおよびサンプルチェンジャーと組み合わせた856 Conductivity Moduleとの接続のための固定式ケーブル (2.0 m) 付き。このセンサーは、以下のような液体などにおける中程度の電気伝導度 (5 µS/cmから100 mS/cm) の自動測定に適しています:飲料水; 表面水; 廃水;
6.09331.110
ProTrode 200 センサーProTrode 200 センサーは、バイオテクノロジーや製薬プロセスのインライン pH 測定を行うために設計された Pt1000 内蔵の複合型 pH センサーです。この非加圧センサーは 0~12 pH の測定範囲を持ち、独自のスライドスリーブダイアフラム設計により、プロセスフローに依存しない短い応答時間で、非常に正確な pH 測定を可能にします。付属の Ag ガードにより、プロセスへの銀の混入、硫化物またはタンパク質を含むプロセスでのダイヤフラムの詰まりを防ぎます。
6.09331.210
ProTrode 300 センサーProTrode 300 センサーは、バイオテクノロジーや製薬プロセスのインライン pH 測定を行うために設計された Pt1000 内蔵の複合型 pH センサーです。加圧センサーは、測定範囲が 0~12 で、セラミックピンダイアフラム設計により、正確な pH 測定が可能で、応答速度も良好です。付属の Ag スカベンジャーにより、プロセスへの銀の混入、硫化物またはタンパク質を含むプロセスでのダイヤフラムの詰まりを防ぎます。
6.09331.310
ProTrode 250 センサーProTrode 250 センサーは Pt1000 を内蔵した複合型 pH センサーで、厳しいセンサー仕様が要求される化学プロセス(例:爆発性雰囲気)においてインライン pH 測定を行うために設計されています。加圧型インライン pH センサーは、測定範囲が 0~14 pH で、独自のスライドスリーブダイアフラム設計により、プロセスフローに依存しない短い応答時間で、非常に正確な pH 測定を可能にします。
6.09331.410
Protrode 350 センサーProTrode 350 センサーは Pt1000 を内蔵した複合型 pH センサーで、厳しいセンサー仕様が要求される化学プロセス(例:爆発性雰囲気)においてインライン pH 測定を行うために設計されています。加圧型インライン pH センサーは、測定範囲が 0~14 pH で、セラミックピンダイアフラム設計により、プロセスフローに依存しない短い応答時間で、非常に正確な pH 測定を可能にします。
6.09331.510
ProTrode 400 センサーProTrode 400 センサー は、化学プロセスのインライン pH 測定のために設計された Pt1000 内蔵の複合型 pH センサーです。この非加圧型センサーの測定範囲は 0 から 14 pH までです。オープンジャンクションダイヤフラム設計は、詰まりのリスクを低減します。これにより、スラリーなど、粒子の含有量が高い媒体での性能が向上します。ProTrode 400 には、高アルカリの H ガラスが使用されており、高い pH 値での精度の高い測定を実現します。
6.09332.010
ProTrode DO センサーProTrode 溶存酸素 (DO) センサーは、最先端の光学技術を使用して正確なリアルタイム測定を実現する、進化した光学溶存酸素 (ODO) センサーです。堅牢な構造により、CIP (定置洗浄)、SIP (定置滅菌)、およびオートクレーブプロセスとの互換性を実現し、過酷なバイオプロセス環境に最適な製品となっています。溶存酸素を連続モニタリングすることで酸素濃度を精密にコントロールできるため、変動を低減し、バッチ間の一貫性を向上させ、規制順守を支援すると同時に、ダウンタイムとメンテナンス要件の両方を最小限に抑えます。 ProTrode DO は、0 ~ 250% の空気飽和度の範囲で信頼性の高い測定を提供する、メンテナンスの手間がからないインライン溶存酸素センサーです。高い衛生基準に基づいて設計されており、CIP および SIP プロセスに耐えることができます。PTFE 強化シリコン皮膜は、容易に交換でき、安定した性能と最小限のダウンタイムを保証します。
6.09339.010
ProTrode pCO2 センサーProTrode pCO₂ センサーは、セバリングハウス原理に従って稼働するインライン溶存二酸化炭素センサーです。この溶存二酸化炭素センサーは、重炭酸電解液が充填されたメンブレンキャップ中のガラス pH 電極で構成されています。二酸化炭素はガス透過膜を通過して飛散し、pH 値を変化させます。グレード 2 のチタン (3.7025) 製メンブレンキャップは耐食性です。6~10 回の高圧蒸気滅菌サイクル終了後、反応時間が長くなり始めたら、交換できます。ProTrode pCO₂ センサーは、医薬品やバイオテクノロジーの製造プロセスに信頼性の高い測定を提供します。耐久性を考慮して設計されたこの溶存二酸化炭素センサーは、定置洗浄 (CIP)、定置滅菌 (SIP)、高圧蒸気滅菌法に対応しており、長期間にわたる耐久性をお約束します。
6.09395.014
Glassy carbon electrode tipElectrode tip made of glassy carbon (GC) for Autolab RDE, electrode disk diameter 3 mm, M4 thread connection. Temperature range: 0 - 40 °C.
6.09395.024
Platinum electrode tipElectrode tip made of platinum (Pt) for Autolab RDE, 3 mm electrode disc diameter, M4 thread connection. Temperature range: 0 - 40°C.
6.09395.034
Gold electrode tipElectrode tip made of gold (Au) for Autolab RDE, electrode disc diameter 3 mm, M4 thread connection. Temperature range: 0 - 40°C.
6.09395.044
Silver electrode tipElectrode tip made of silver (Ag) for Autolab RDE, 3 mm electrode disc diameter, M4 thread connection. Temperature range: 0 - 40°C.
6.1110.010
909 UV Digester用Pt1000温度センサー909 UV Digesterとの接続のための固定式ケーブル (0.5 m) 付きガラス製Pt1000温度センサー (クラス B)。
6.1110.100
Pt1000-温度センサー (取り付け長さ12.5 cm)ガラス製Pt1000-温度センサー (クラスB)。このPt1000-温度センサーは、取り付け長さ17.8cmの製品番号6.1110.110でも入手可能です。
6.1110.110
Pt1000 温度センサー (取り付け長さ 17.8 cm)サンプルチェンジャー用ガラス製Pt1000温度センサー (クラス B)。
6.1110.120
CVS用Pt1000温度センサー (取り付け長さ9 cm)Professional-CVS装置用Pt1000温度センサー (クラス B)。
6.1111.010
安定性測定装置用Pt100温度センサー (17.5 cm)固定式ケーブルおよびMini DINプラグ付きPt100温度センサー (長さ 17.5 cm)。このガラス不使用の温度センサーは、711 Liquinoおよび安定性測定装置 (743 Rancimat、763 PVC Thermomat、892 Professional Rancimat、または895 Professional PVC Thermomat) での使用に適しています。
6.1111.020
安定性測定装置用Pt100温度センサー (30 cm)固定式ケーブルおよびMini DINプラグ付きPt100温度センサー (長さ 30 cm)。このガラス不使用の温度センサーは、安定性測定装置 (873 Biodiesel Rancimatおよび893 Professional Biodiesel Rancimat) での使用に適しています。
6.1113.000
Sensor for 849 Level ControlSensor for 849 Level Control
6.1113.100
Level sensor MF for 10 L canisterSensor for Level Control MF
6.1114.010
ステンレス製Pt1000温度センサー固定式ケーブル (1.2 m) 付きPt1000温度センサー (クラス B)、ステンレス製ピンおよびPEEK製シャフト付き。このガラス不使用の温度センサーは、以下の物質での温度測定に適しています:半固形物質 (例えばチーズ、食肉など); pH 1~13の非酸化性媒質;
6.1115.000
Optrode使用可能な8つの波長を有する光度滴定のための光学センサー。波長の切り替えは、ソフトウェア制御 (tiamo 2.5以降) またはマグネットで実行できます。ガラスシャフトは完全な耐溶剤性を有し、洗浄が簡単です。省スペースのセンサーは以下のような用途に適しています:USPまたはEPに則した非水滴定; カルボキシル末端基の測定; ASTM D974に則したTAN/TBN; 硫酸塩の測定; セメント中のFe、Al、Ca; 水の硬度; USPに則したコンドロイチン硫酸; センサーは、色の強度の測定 (比色法) による濃度の測定には適していません。
6.1116.000
O2-Lumitrode溶存酸素 (DO) の測定のための光学センサーは、913 pH/DO Meter または 914 pH/DO/Conductometer と共に使用することができます。センサーの測定の原則は、ルミネセンス消光に基づきます。省スペースかつメンテナンスフリーのセンサーは、以下のような場面での DO 測定に適しています:水質管理; 水処理業界; 飲料生産; 養殖漁業; センサーは、校正容器と共に納品されます。 酸素に敏感な発光団を含む測定キャップ (O2 キャップ) は、必要に応じて容易に交換することができます。
6.1125.000
Optrode M2Optical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:Non-aqueous titrations in accordance with USP or EP; Determinations of carboxyl end groups; TAN/TBN in accordance with ASTM D974; Sulfate determination; Fe, Al, Ca in cement; Water hardness; Chondroitin sulfate in accordance with USP; The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).
6.1204.130
Silver Electrode TipMetal electrode tip, silver (Ag). Electrode disk diameter 2 mm. M3 thread. Temperature range: 0 ... 40 °C.
6.1204.140
Gold Electrode TipMetal electrode tip, gold (Au). Electrode disk diameter 2 mm. M3 thread. Temperature range: 0 ... 40 °C.
6.1204.150
Lateral Gold Electrode TipMetal electrode tip, gold (Au), with lateral electrode surface. Electrode disk diameter 3 mm. M3 thread. Temperature range: 0 ... 40 °C.
6.1204.170
3 mm platinum electrode tip for CVSMetal electrode tip made of platinum (Pt), diameter of electrode disk 3 mm, polished surface, M3 thread connection. Temperature range: 0 - 40 °C.
6.1204.180
Ultra Trace electrode tipCarbon electrode tip from Ultra Trace graphite. Electrode disk diameter 2 mm. M3 thread connection. Temperature range: 0 - 40 °C.
6.1204.190
1 mm platinum electrode tip for CVSMetal electrode tip made of platinum (Pt), diameter of electrode disk 1 mm ±0.02 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: 0.2 mm. Temperature range: 0 - 50 °C.
6.1204.210
Driving axle for rotating disk electrode (RDE)Driving axle for rotating disk electrode (RDE) with titanium axle for VA measuring stands, M3 thread.
6.1204.220
Driving axle for rotating disk electrode (RDE) with mercury contactDriving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for VA measuring stands, M3 thread.
6.1204.300
Glassy Carbon 電極チップGlassy Carbon 製 (GC) 電極チップ、Autolab RDE用、電極盤直径 3 mm、ねじコネクタ M4。温度範囲: 0 ~ 40 °C。
6.1204.310
プラチナ製電極チッププラチナ製 (Pt) 電極チップ、Autolab RDE用、電極盤直径 3 mm、ねじコネクタ M4。温度範囲: 0 ~ 40 °C。
6.1204.320
金製電極チップ金製 (AU) 電極チップ、Autolab RDE用、電極盤直径 3 mm、ねじコネクタ M4。温度範囲: 0 ~ 40 °C。
6.1204.330
銀製電極チップ銀製 (Ag) 電極チップ、Autolab RDE用、電極盤直径 3 mm、ねじコネクタ M4。温度範囲: 0 ~ 40 °C。
6.1204.510
Driving axle for rotating disk electrode (RDE)Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
6.1204.520
Driving axle for rotating disk electrode (RDE) with mercury contactDriving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for Professional VA/CVS instruments, M3 thread.
6.1204.600
Glassy carbon electrode tip, shaft made of glass.Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: 0.25 mm. Temperature range: 0 - 50°C.
6.1204.610
2 mm platinum electrode tip for CVSMetal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: 0.3 mm. Temperature range: 0 - 50 °C.
6.1226.030
Mercury drop capillary (non-silanized) for MMENon-silanized mercury drop capillary (10 pieces)
6.1226.050
Mercury drop capillary (silanized) for MMESilanized mercury drop capillary (10 pieces)
6.1240.000
Electrolyte vessel / diameter 3 mmWith PTFE capillary and ceramic diaphragm (3 mm)
6.1240.020
Electrolyte vessel, diameter 1 mmWith ceramic diaphragm (D type).
6.1241.020
電極ホルダVA 対極用の電極ホルダ、端子ねじ付き。Glassy Carbon ピン (6.1247.000) もしくは白金ピン (6.1247.010) を伴う使用向け。
6.1241.030
Electrode shaftElectrode shaft for separate metal pin electrodes
6.1241.040
Electrode shaftElectrode shaft for separate metal pin electrodes. For sample changer applications.
6.1241.050
Electrode shaftElectrode shaft for polymer membrane electrodes with exchangeable electrode tip
6.1241.060
Electrode shaftFor 6.1204.XXX electrode tips and 6.2103.1XX contact pins. Electrode plug-in head B (4 mm).
6.1241.080
scTRACE Gold のための電極シャフト作用電極、参照電極、および補助電極(AE)用電極ケーブルの接続のためのプラグコンタクト付き scTRACE Gold 用ホルダー。電極シャフトは、scTRACE Gold 6.1258.000 と共に、Professional VA 装置で用いられる電圧電流法のための完全なセンサーになります。VA スタンドベースおよび VA Computrace で使用するには、アダプター 6.2112.130 が3つ必要です。scTRACE Gold はただシャフトに差し込むだけです。scTRACE Gold は一定間隔で定期的に交換しますが、電極シャフトは続けて使用することができます。
6.1241.090
スクリーンプリント電極 (SPE) 用の電極シャフト作用電極、参照電極、および補助電極用の電極ケーブルの接続のためのプラグコンタクト付きスクリーンプリント電極 (screen-printed electrodes、SPE) 用ホルダー。電極シャフトは、スクリーンプリント電極と共に、電圧電流法のための完全なセンサーになります。スクリーンプリント電極は定期的に交換しなければなりませんが、電極シャフトは続けて使用することができます。
6.1241.120
電極ホルダVA 対極用の電極ホルダ、プラグコンタクト 5.5 mm 付き。Glassy Carbon ピン (6.1247.000) もしくは白金ピン (6.1247.010) を伴う使用向け。
6.1243.020
Ground diaphragmSpare ground-joint diaphragm for 6.0255.1XX Profitrodes
6.1243.030
Diaphragm for reference electrodeSpare ground-joint diaphragm for 6.0726.1XX and 6.0729.1XX reference electrodes
6.1245.000
ガラス製内部液容器ダブルジャンクション参照電極のためのグランドジョイントダイアフラム (すり合わせ) 付きガラス製内部駅容器。
6.1245.010
プラスチック製内部液容器ダブルジャンクション参照電極のためのセラミックダイアフラム付きプラスチック製内部液容器。
6.1246.120
Multi-Mode Electrode proMercury electrode for voltammetry. Can be operated as DME, SMDE or HMDE.
6.1247.000
GCピン電圧電流法AE用の電極ホルダ6.1241.020もしくは6.1241.120のため。
6.1247.010
白金ピン (Pt)電圧電流法AE用の電極ホルダ6.1241.020もしくは6.1241.120のため。
6.1247.020
Needles for MMENeedles for Multi Mode Electrode (3 pieces).
6.1248.000
Platinum Electrode RodPlatinum Electrode Rod for separate metal pin electrode
6.1248.010
Silver Electrode RodSilver Electrode Rod for separate metal pin electrode
6.1248.030
Gold Electrode RodGold Electrode Rod for separate metal pin electrode
6.1248.040
Glassy Carbon Electrode RodGlassy Carbon Electrode Rod for separate metal pin electrode
6.1248.050
Tungsten Electrode RodTungsten Electrode Rod for separate metal rod electrode
6.1253.010
Measuring insertFor checking the oven temperature of the 774 Oven Sample Processor
6.1254.070
Silver flow cell for BioscanFlow cell for Bioscan, electrode material: Silver
6.1254.130
Platinum Variocell for BioscanPlatinum measuring cell with replaceable working electrode.
6.1254.140
Silver Variocell for BioscanSilver measuring cell with replaceable working electrode.
6.1254.230
Platinum working electrode for VariocellPlatinum working electrode for 6.1254.1X0 Variocell
6.1255.000
Replacement Kit for NH3-selective Electrode 6.0506.100Consisting of: replacement module (3 pieces), measuring electrolyte (50 mL)
6.1255.050
NH 3 Replacement Module Kit: MembraneComprised of: 1 replacement membrane module 1 package of 20 membranes 1 tweezers.
6.1257.010
Wall-Jet CellAmperometric detector cell with Wall-Jet geometry.
6.1257.100
Thin-Layer cellAmperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).
6.1257.210
Au working electrode, 3 mmWorking electrode made of gold for amperometric detection, 3 mm diameter.
6.1257.220
GC working electrodeWorking electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.
6.1257.230
Pt working electrodePlatinum working electrode for amperometric detection, 3 mm diameter.
6.1257.240
Ag working electrodeSilver working electrode for amperometric detection, 3 mm diameter.
6.1257.260
Au working electrode, 2 mmWorking electrode made of gold for amperometric detection, 2 mm diameter.
6.1257.270
Cu working electrode, 2 mmWorking electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.
6.1257.720
Ag/AgCl reference electrode for 6.1257.xxxSilver/silver chloride reference electrode for amperometric detection.
6.1257.740
Pd reference electrode to 6.1257.xxxPalladium reference electrode for amperometric detection.
6.1258.000
scTRACE Gold (set with 4 pieces)Gold micro-wire electrode on thick film basis for the determination of arsenic in waters. The scTRACE Gold is a combined voltammetric sensor for voltammetry. Gold micro-wire working electrode, Ag/AgCl reference electrode and carbon auxiliary electrode are located on a sensor. Simple in its handling and practically maintenance-free, the scTRACE Gold can for example be used to determine arsenic in water in the trace range. Together with the 6.1241.080 electrode shaft, it can be used with any Metrohm voltammetry measuring stand.
6.2106.020
Cable with two banana plugs6.2709.130
アダプター B-14/15 - SPE 測定ヘッドインサート (VA)SPE 測定ヘッド 6.1256.030 付き 884 Professional VA での、または測定ヘッドインサート 6.1412.020 付き 797 VA Computrace もしくは 663 VA Stand における電極シャフト (scTRACE Gold) 6.1241.080 または Bismut 滴下電極 6.0346.000 の使用のためのアダプター。
6.5337.000
IC equipment Wall-Jet cell: without electrodesEquipment comprised of Wall-Jet cell with additional accessories, without electrode.
6.5337.010
IC equipment Wall-Jet cell: Carb (Au, Pd)Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.
6.5337.020
IC equipment Wall-Jet cell: Cyanide (Ag, Pd)Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.
6.5337.030
IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.
6.5337.200
IC equipment Thin-Layer cell: without electrodesEquipment comprised of Thin-Layer cell with additional accessories, without electrodes.
6.5339.000
CVS electrode equipment with 1 mm platinum electrode for Professional VA/CVS instrumentsComplete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 1 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.
6.5339.010
CVS electrode equipment with 2 mm platinum electrode for Professional VA/CVS instrumentsComplete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.
6.5339.020
CVS electrode equipment with 3 mm platinum electrode for Professional VA/CVS instrumentsComplete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 3 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.
6.5339.030
VA electrode equipment with Multi-Mode Electrode pro for Professional VA instrumentsComplete electrode set for polarographic and voltammetric determinations. Includes Multi-Mode Electrode pro, reference electrode, platinum auxiliary electrode, measuring vessel, stirrer, electrolyte solution and additional accessories for setting up and operating the Multi-Mode Electrode.
6.5339.040
VA electrode equipment with rotating disc electrode (RDE) made of glassy carbon for Professional VA instrumentsComplete electrode set for voltammetric determinations, e.g. using mercury film method. Includes drive for rotating disk electrode, glassy carbon electrode tip, reference electrode, glassy carbon auxiliary electrode, measuring vessel, and electrolyte solution.
6.5339.050
VA electrode equipment with scTRACE Gold for Professional VA instrumentsComplete electrode set for the determination of arsenic or mercury. Includes holders for scTRACE Gold, scTRACE Gold, stirrer and measuring vessel.
6.5339.060
集中的な使用に適した Professional VA/CVS 装置用の2 mm白銀電極付き CVS 電極装備CVS (サイクリックボルタンメトリーストリッピング) を用いた電気めっき浴中の有機添加物の測定のための完全な電極セット。回転白銀電極 (電極の直径: 2 mm)、水銀接点の駆動軸、メンテナンス不要のゲル参照電極、白銀補助電極、測定容器、およびKCl電解質溶液が含まれます。
6.5339.070
Professional VA 装置用の SPE 電極シャフト付き VA 付属装備品スクリーンプリント電極 (screen-printed electrodes、SPE) の使用のための付属装備品。スクリーンプリント電極用の電極シャフト、スターラ、および測定容器を含みます。電極は含みません。
6.5339.080
Professional VA 装置用のビスマス滴電極付き VA 電極装備重金属のボルタンメトリー測定のための電極セット一式。ビスマス滴電極、参照電極、グラッシーカーボン(ガラス状炭素)補助電極(AE)、測定容器、スターラ、電解質溶液、ならびにその他付属品を含みます。
6.5339.100
Professional VA 装置用の抗酸化物質測定のための Glassy Carbon 回転円盤電極付き VA 電極装備抗酸化物質の測定のための電極セット一式。回転円盤電極用駆動システム、Glassy Carbon 電極チップ、白金参照電極、白金対極および測定容器が含まれています。
6.5339.110
2㎜ 白金電極付き CVS 電極装備、Professional-VA/CVS 装置用ゲル参照電極およびステンレス対極CVS (サイクリックボルタンメトリーストリッピング) を用いた電気めっき浴中の有機添加物の測定のための完全な電極セット。回転白金作用電極 (電極の直径: 2 mm)、水銀接点の駆動軸、メンテナンス不要のゲル参照電極、ステンレス対極、測定容器、および KCl 電解液が含まれます。
6.5340.000
VA Computrace用のscTRACE Gold付きVA電極機器scTRACE Goldによるヒ素または水銀の測定のための完全な付属品セット。電極ホルダー、scTRACE Gold(4個)、測定容器、スターラー、その他の付属品を含む。
6.5340.030
VA Computrace 用 SPE 電極シャフト付きの VA 電極ホルダキットスクリーンプリント電極 (screen-printed electrodes、SPE) の使用のための付属装備品。スクリーンプリント電極用の電極シャフト、測定容器、スターラ、その他の付属品を含みます。電極は含みません。
6.9011.020
Thermoprobe859 TitrothermによるTETのための高精度の温度センサー。Thermoprobeは短い反応時間と高い分離度を有し、ごくわずかな温度変化を正確に捉えることができます。このセンサーは、HFを含まない水性および非水系の溶液にて、以下の測定などに用いることができます: ASTM D8045に準じた酸価 (TAN) ; 塩基価 (TBN); 遊離脂肪酸; Ca/Mg 測定; リン酸;
6.9011.040
Thermoprobe HFHFを含む媒質における859 TitrothermによるTETのための高精度の温度センサー。Thermoprobeは短い反応時間と高い分離度を有し、ごくわずかな温度変化をも正確に捉えることができます。このセンサーは、酸性の、フッ化物を含む溶液にて使用することができますが、有機性溶媒に対する耐性はありません。これは以下の用途などに適しています: ナトリウムの測定; エッチング槽の滴定;
6.9903.048
KF indicator electrode for automationDouble platinum wire electrode for automation with fixed cable, plug F
6.9921.223
854 iConnect / 3 m854 iConnect - インテリジェント電極 «iTrodes» 用の電極ケーブルと測定アンプ。このバージョンは 3 m のケーブルを備え、自動化されたシステムでの使用が想定されています。
AG.100
Silver micro electrode 100 µmSilver micro electrode with a disk diameter of 100 µm.
6.01408.000
Oリング 46 x 2.5 mm946 Portable VA Analyzer の測定スタンド用。2個セット。
6.01408.010
カールフィッシャー滴定セル用パッキンキット6.05609.000および6.05609.010に適したパッキンキット一式。
6.01412.000
プラスチック製サンプルビーカー、5 個プラスチック製 (ポリエチレン、PP) サンプルビーカー 5~30 mL、目盛り付き 946 Portable VA Analyzer に適合、5 個
6.01450.210
スクリューキャップつき PFA 滴定容器、10 ~ 90 mLフッ化物を含む溶液内でのアプリケーション用のスクリューキャップつき PFA 滴定容器 10 ~ 90 mL。滴定容器用蓋 6014050X0 に対応。
6.01462.010
滴定ヘッドアダプターThis adapter enables the utilization of titration heads of the Sample Processor generation (814/815/855) on sample changers with screw-on titration heads.
6.01503.120
シリンダーユニット OMNIS 2 mL 付属品なしOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 2 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.01503.150
シリンダーユニット OMNIS 5 mL 付属品なしOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 5 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.01503.210
シリンダーユニット OMNIS 10 mL 付属品なしOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 10 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.01503.220
シリンダーユニット OMNIS 20 mL 付属品なしOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 20 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.01503.250
シリンダーユニット OMNIS 50 mL 付属品なしOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 50 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.01508.210
シリンダーユニット OMNIS スペシャル 10 mL、付属品なしOMNIS Titrator、滴定モジュールもしくはドージングモジュールのためのインテリジェントなシリンダーユニット 10 mL。このシリンダーユニットは次の溶液に非常に適しています:• 水性アルカリ溶液• 滴定試薬 5• 硝酸銀溶液• 非水性アルカリ溶液• 過マンガン酸塩溶液• EDTA溶液ドージングチューブ、拡散防止ビュレットチップを含まない。
6.01508.220
シリンダーユニット OMNIS スペシャル 20 mL、付属品なしOMNIS Titrator、滴定モジュールもしくはドージングモジュールのためのインテリジェントなシリンダーユニット 20 mL。このシリンダーユニットは次の溶液に非常に適しています:水性アルカリ溶液; 滴定試薬 5; 硝酸銀溶液; 非水性アルカリ溶液; 過マンガン酸塩溶液; EDTA 溶液; ドージングチューブおよび反拡散チップを含まない。
6.01543.000
排液チップM8For aspirating off reagent in connection with the OMNIS Solvent Module.
6.01543.100
排液チップオートメーションAspiration tip for automated OMNIS titrations.
6.01543.110
排液チップオートメーション用チューブ、3個Replacement hose for 601543100 aspiration tip.
6.01543.120
拡散防止用シリンジ拡散防止バルブ付き滴定チップ、OMNIS KF滴定装置に適合。
6.01562.000
ピペット 5 mL、PE 製、目盛り付き、2 個セット容量 0.5 mL、1 mL、2 mL、3 mL、4 mL、5 mL用プラスチック製ピペット
6.01562.010
マイクロピペット 100 µLミニマイクロピペット 100 µL 定量。
6.01600.010
OMNIS Liquid Adapter3S テクノロジーの試薬ボトルを、OMNIS 滴定装置、滴定モジュール、またはドージングモジュールと接続するためのアダプター。
6.01600.200
サイホンブレーカーPrevents continued running of liquid out of the reagent bottle into the titration cell.
6.01601.000
ボトルキャップ multi-use試薬ボトルをOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールと接続するための、3S テクノロジーの再利用可能なボトルキャップ。
6.01602.000
6.01600.010 の吸入カップリング6.01600.010 OMNIS Liquid Adapter のための吸入カップリング (スペアパーツ)
6.01620.000
ボトル 30 mL、PP 製、2 個セットプラスチック製ボトル、ワイドネック、スクリューキャップ付き。
6.01620.010
ボトル 125 mL、PP 製プラスチック製ボトル、ワイドネック、目盛り付き、ラベル用スペースおよびスクリューキャップ付き。
6.01801.020
ペリスタリックポンプモジュールのためのポンプチューブPharm-A-lineポンプチューブには、ポンプモジュールのペリスタリックポンプに直接取り付けることができるアダプターが既に装備されています。Pharm-A-line ポンプチューブは水性溶液および非水性溶液を移動させるためのものであり、ポンプモジュール内の圧迫クリップ白と接続して稼働しなければなりません。
6.01803.000
シリコンチューブ 8/12 2.5 mこぼれ出た溶液が排出物用容器に安全に流れるよう、Pick&Place モジュールもしくはポンプモジュールの排出口と接続するためのシリコンチューブ。
6.01804.210
ポリ塩化ビニルチューブ 4/6 0.35 mFor tubing connections to the OMNIS Solvent Module or the Solvent Pump.
6.01804.410
OMNISサンプルロボットSのための排水溝The drain channel is mounted behind the workstations of the OMNIS Sample Robot S and, in case of an error, collects any overflowing solution in order to channel it safely and contact-free through tubing into a waste canister.
6.01804.430
OMNISサンプルロボットM/Lのための排水溝The drain channel is mounted behind the workstations of the OMNIS Sample Robot M/L and, in case of an error, collects any overflowing solution in order to channel it safely and contact-free through tubing into a waste canister.
6.01804.460
OMNIS Sample Robot M/L WSM 用の排水溝排水溝は OMNIS Sample Robot WSM M/L のワークステーション後部に取り付けられ、エラーの場合にはあふれた溶液を収容し、チューブを経由して非接触で安全に廃棄物容器に移送します。
6.01804.500
排水チューブ用のチューブアダプターPick&Place モジュールの排水チューブ用チューブアダプター、および OMNIS Sample Robot Pick&Place のポンプモジュール。
6.01805.000
FEP チューブ接続部 / M6 / 66.5 cm遮光および折れ曲がり防止付き。
6.01805.010
PTFE チューブ接続部 / M8 / 66.5 cm遮光および折れ曲がり防止付き。
6.01805.100
PTFE チューブ ルアー 60 cm 付きPick&Place モジュールにディストリビュータ― (洗浄) が付いたポンプモジュール・ペリスタリックポンプ 1 または 3 の接続のためのチューブ
6.01805.110
PTFE チューブ ルアー 80 cm 付きPick&Place モジュールにディストリビュータ― (吸入) が付いたポンプモジュール・ペリスタリックポンプ 2 または 4 の接続のためのチューブ
6.01805.120
PTFE チューブ ルアー 2.5 m 付きキャニスターが付いたポンプモジュール内のペリスタリックポンプの接続のためのチューブ
6.01805.130
スクリューニップル付きPTFEチューブ 3/250 mm試薬ボトルをサイホンブレーカーと接続するためのスクリューニップル付き吸引チューブ。
6.01805.470
FEP チューブ M6、1/8" x 1.59 mm、500 mm、CT OUTイオンクロマトグラフの Continuous Anion Trap の出口と Waste Collector を接続する FEP チューブ。
6.01806.000
PEEK製キャピラリー 0.18 mm 内径 / 2 m例えば2 mm 仕様のMetrosep Carb 2 カラム (6.01090.2x0) 用の予熱キャピラリーとしてなど、高圧流路での使用向け。
6.01807.000
吸着カートリッジOMNISソルベントモジュールまたはソルベントポンプ用吸着カートリッジ、モレキュラーシーブ6.2811.000での充填用。
6.01807.010
吸着カートリッジ OMNIS Oven ModuleOMNIS Oven Module に適した吸着カートリッジ
6.01808.010
Y型チューブ接続部、PP製、3 x 7-8 mmConnector for waste tubing
6.01816.010
シリコン製チューブ、8/12 mm、2 m排水チューブ
6.01829.010
スペアチューブセット加熱チューブストッパー 6.1446.200 または試薬交換溶媒モジュールのストッパー 6.1446.220 用スペアチューブ
6.01831.010
PEEK 製キャピラリー、0.25 mm、HPP OUTA PEEK capillary that connects the high-pressure pump of the ion chromatograph with the Eluent Producer Cartridge (EPC) of the 948 Continuous IC Module, CEP.
6.01831.020
PEEK 製キャピラリー、0.25 mm、EPC OUTA PEEK capillary that connects the Eluent Producer Cartridge (EPC) with the Continuous Trap (CT) of the 948 Continuous IC Module, CEP.
6.01831.030
PEEK 製キャピラリー、0.25 mm、CT OUTA PEEK capillary that connects the Continuous Trap (CT) with the High-Pressure Degasser (H-DEG) of the 948 Continuous IC Module, CEP.
6.01831.040
PEEK 製キャピラリー、0.25 mm、H-DEG OUT948 Continuous IC Module, CEP の High-Pressure Degasser (H-DEG) とイオンクロマトグラフのインジェクタを接続する PEEK 製キャピラリー。
6.01831.050
PEEK 製キャピラリー、0.25 mm、H-DEG RinseA PEEK capillary that connects the High-Pressure Degasser (H-DEG) of the 948 Continuous IC Module, CEP with the waste collector of the ion chromatograph.
6.01900.010
プロペラスターラー 30 mm ETFEロッドスターラー「Titrator」もしくはロッドスターラー「Sample Robot」と併用される、高さ調節が可能なプロペラスターラー ETFE 30 mm
6.01900.020
プロペラスターラー 13 mm ETFEロッドスターラー「Titrator」もしくはロッドスターラー「Sample Robot」と併用される、高さ調節が可能なプロペラスターラー ETFE 13 mm
6.01900.030
プロペラスターラー 20 mm ETFEロッドスターラー「Titrator」もしくはロッドスターラー「Sample Robot」と併用される、高さ調節が可能なプロペラスターラー 20 mm
6.02001.010
ラック基盤OMNIS Sample Robot のメインモジュール拡張のためのラック基盤
6.02001.200
Eco Titrator / Eco Dosimat の 6.1414.XXX 用アダプターEco Titrator / Eco Dosimat で 6.1414.XXX の滴定容器上部付き 6.1415.XXX / 6.1418.XXX を使用するため。
6.02003.010
モジュール基盤 M/LOMNIS Sample Robot のメインモジュール M/L 拡張のためのモジュール基盤。
6.02004.010
ボトルホルダーOMNIS 滴定装置、滴定モジュール、およびドージングモジュールのためのボトルホルダー。
6.02004.030
ボトルホルダーOMNISソルベントモジュール2.1009.0010用ボトルホルダー。
6.02005.000
電極ホルダー OMNISOMNIS 滴定システムのための電極ホルダー。
6.02005.010
電極保管ステーション電極を OMNIS 滴定システムに保管しておくための電極保管ステーション。
6.02007.000
サンプルロボット蓋ホルダー用ダミーパネルマウントFixing panel for assembling lid trays on dummy panels in the OMNIS Sample Robot System Pick&Place.
6.02007.010
OMNISサンプルロボットSのための蓋ホルダーOMNISサンプルロボットSシステムにて、OMNISポンプモジュールまたはダミーパネル6.02007.000に設置する蓋ホルダー。
6.02007.020
OMNISサンプルロボットM/Lのための蓋ホルダーOMNISサンプルロボットMまたはLシステムにて、OMNISポンプモジュールまたはダミーパネル6.02007.000に設置する蓋ホルダー。
6.02008.010
PolytronホルダーPolytronの固定用、601405040に適合。
6.02008.030
Eco滴定装置のためのホモゲナイザー用ホルダーHolder for homogenizer for fastening the Polytron in place, suitable for 601405060 titration vessel lid
6.02041.010
OMNISサンプルラック、9 x 250 mL、(PP)9個のサンプルビーカーに適合した OMNISサンプルロボットピック&プレイスのための OMNISサンプルラック。以下のサンプルビーカーの使用が可能です: 6.01400.000、6.01400.003、6.01400.100。合成樹脂: ポリプロピレン (PP)
6.02041.020
OMNISサンプルラック、9 x 200 mL、(PP)9個のサンプルビーカーに適合した OMNISサンプルロボットピック&プレイスのための OMNISサンプルラック。以下のサンプルビーカーの使用が可能です: 6.1459.310。合成樹脂: ポリプロピレン (PP)
6.02041.030
OMNISサンプルラック、16 x 120 mL、(PP)16個のサンプルビーカーに適合した OMNISサンプルロボットピック&プレイスのための OMNISサンプルラック。以下のサンプルビーカーの使用が可能です: 6.01400.200、6.01400.300、6.01400.303。合成樹脂: ポリプロピレン (PP)
6.02041.040
OMNISサンプルラック、25 x 75 mL、(PP)25個のサンプルビーカーに適合した OMNISサンプルロボットピック&プレイスのための OMNISサンプルラック。以下のサンプルビーカーの使用が可能です: 6.01402.000、6.01402.003、6.1459.400。合成樹脂: ポリプロピレン (PP)
6.02041.050
OMNISサンプルラック、9 x 150 mL、(PP)9個のサンプルビーカーに適合した OMNISサンプルロボットピック&プレイスのための OMNISサンプルラック。以下のサンプルビーカーの使用が可能です: 150 mL ビーカー (トールビーカー、注ぎ口なし)。合成樹脂: ポリプロピレン (PP)
6.02041.060
サンプルラック OMNIS 50 x 6 mLOMNIS sample rack for OMNIS Sample Robot Oven, suitable for 50 sample vials (6.2419.000)
6.02041.070
サンプルラック OMNIS 50 x 8 mLOMNIS sample rack for OMNIS Sample Robot Oven, suitable for 50 sample vials (6.2420.007)
6.02041.080
サンプルラック OMNIS 77 x 8mmOMNIS sample rack for OMNIS Sample Robot – NIR suitable for 77 disposable vials with an optical path length of 8 mm for measurements in transmission (6.7402.240).
6.02041.090
サンプルラック OMNIS 77 x 15mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 77 disposable vials with a diameter of 15 mm for measurements in reflection (6.7402.110).
6.02041.100
サンプルラック OMNIS 50 x 19mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 50 disposable vials with a diameter of 19 mm for measurements in reflection (6.7402.120).
6.02041.110
サンプルラック OMNIS 50 x 22mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 50 disposable vials with a diameter of 22 mm for measurements in reflection (6.7402.130).
6.02041.120
サンプルラック OMNIS 27 x 28mmOMNIS sample rack for OMNIS Sample Robot – NIR, suitable for 27 disposable vials with a diameter of 28 mm for measurements in reflection (6.7402.140).
6.02041.130
サンプルラック OMNIS、50 x 6 mL バイアルOMNIS sample rack for OMNIS Sample Robot NIR, suitable for 50 x 6 mL sample glasses (62419000) with septum (61448057).
6.02041.140
サンプルラック OMNIS 77 x 2ROMNIS Sample Robot Oven 用サンプルラック OMNIS、2R サンプルバイアル 77 個に対応.
6.02042.000
ラックラベル用ホルダ (3x)ラックラベル用ホルダーにより、ラックにはっきりと名前を記してしっかり保管することができます。
6.02047.000
OMNIS 滴定セルホルダーTitration cell holder for fastening a coulometric titration cell to an OMNIS Coulometer or OMNIS Coulometer Module
6.02057.030
限外ろ過セル2用ホルダー6.02729.110限外ろ過セル2を858 Professional Sample Processor / 919 IC Autosampler plusに取り付けるためのホルダー。
6.02057.120
限外ろ過セル2用ホルダー、スタンドアローン6.02729.110限外ろ過セル2用ホルダー
6.02064.020
サンプルビーカー 200 mL 用ビーカーリテーナーOMNIS Sample Robot Pick&Place のグリッパーフィンガーにサンプルビーカー 200 mLを固定するためのビーカーリテーナ―
6.02100.010
計測モジュール デジタルデジタル電極「dTrodes」と接続するための OMNIS 滴定装置もしくは滴定モジュールのデジタル計測チャンネル。
6.02101.010
計測モジュール アナログアナログ電極と接続するための OMNIS 滴定装置もしくは滴定モジュールのアナログ計測チャンネル。
6.02101.011
アナログ測定モジュールアナログ電極と接続するための OMNIS Titrator もしくは滴定モジュールのアナログ計測チャンネル。OMNIS Software のバージョン 2.18、またはそれ以上と互換性があります。
6.02101.020
測定モジュール 電気伝導度Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.
6.02102.010
ケーブル MDL プラグ/ソケット 0.5 mMDL コネクタを有する OMNIS デバイスのための接続ケーブル (0.5 m)
6.02102.020
ケーブル MDL プラグ/ソケット 1 mMDL コネクタを有する OMNIS デバイスのための接続ケーブル (1 m)
6.02102.030
ケーブル MDL プラグ/ソケット 2 mMDL コネクタを有する OMNIS デバイスのための接続ケーブル (2 m)
6.02102.040
ケーブル MDL プラグ/ソケット 5 mMDL コネクタを有する OMNIS デバイスのための接続ケーブル (5 m)
6.02102.050
ケーブル MDL プラグ/ソケット 10 mMDL コネクタを有する OMNIS デバイスのための接続ケーブル (10 m)
6.02104.000
電極ケーブル プラグへッド G / プラグ P、0.55 mアナログ電極 (プラグへッド G) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02104.010
電極ケーブル プラグへッド G / プラグ P、1.5 mアナログ電極 (プラグへッド G) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02104.020
電極ケーブル プラグへッド G (Temp.) / プラグ P、0.55 m温度センサー (ヘッド G) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02104.030
電極ケーブル プラグへッド G (Temp.) / プラグ P、1.5 m温度センサー (ヘッド G) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02104.040
電極ケーブル プラグへッド G (Pol) / プラグ P、0.55 mアナログ分極性電極 (プラグへッド G) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02104.050
電極ケーブル プラグへッド G (Pol) / プラグ P、1.5 mアナログ分極性電極 (プラグへッド G) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02104.300
電極ケーブル プラグへッド Q / プラグ P、0.55 mdTrode (プラグへッド Q) を OMNIS のデジタル測定モジュールに接続するケーブル
6.02104.310
電極ケーブル プラグへッド Q / プラグ P、1.5 mdTrode (プラグへッド Q) を OMNIS のデジタル測定モジュールに接続するケーブル
6.02104.600
電極ケーブル プラグへッド U / プラグ P、0.55 m電極 (プラグへッド U) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02104.610
電極ケーブル プラグへッド U / プラグ P、1.5 m電極 (プラグへッド U) を OMNIS のアナログ測定モジュールに接続するケーブル
6.02105.000
ケーブルストランド、長さ 0.55 m個別の参照電極をOMNIS滴定システムのアナログ電極インプット口に接続するための電極ケーブル (1x バナナプラグ 4 mm、1x バナナプラグ 2 mm)。
6.02105.010
ケーブルストランド、長さ 1.5 m個別の参照電極をOMNIS滴定システムのアナログ電極インプット口に接続するための電極ケーブル (1x バナナプラグ 4 mm、1x バナナプラグ 2 mm)、長さ 1.5 m。
6.02106.000
延長ケーブル Liquid Adapter 0.55 mOMNIS Liquid Adapter を OMNIS 滴定装置、滴定モジュール、またはドージングモジュールと接続するための延長ケーブル (長さ 0.55 m)。
6.02106.010
延長ケーブル Liquid Adapter 2 mOMNIS Liquid Adapter を OMNIS 滴定装置、滴定モジュール、またはドージングモジュールと接続するための延長ケーブル (長さ 2 m)。
6.02107.000
ネットワークケーブル 1mOMNIS Sample Robot または OMNIS 滴定装置をイーサネットルーター、イーサネットスイッチ、もしくはローカルネットワークに接続するためのネットワークケーブル (1m)
6.02107.010
ネットワークケーブル 2mOMNIS Sample Robot または OMNIS 滴定装置をイーサネットルーター、イーサネットスイッチ、もしくはローカルネットワークに接続するためのネットワークケーブル (2m)
6.02108.000
ケーブル USB ミニ - USB A、2 m、フェライトコア 2 点付き6.021.08010
ケーブルUSB mini - USB A、1.5 mFor connecting USB instruments.
6.02109.000
アダプタケーブルOMNISこのアダプタケーブル (ソケットF、プラグP) は、固定ケーブル付きで、温度センサーの無いセンサー (例えばOptrodeまたはSolvotrode easyCleanなど) のOMNISアナログ測定モジュールへの接続に適しています。
6.02109.010
6.0340.000のためのアダプタケーブルOMNIS (Pol. /分極性)分極性KF電極6.0340.000のためのアダプタケーブル (ソケットF、プラグP)、OMNISのアナログ測定モジュールに接続可能。
6.02110.000
接続ケーブル Eco KF Titrator/Solvent PumpSolvent PumpをEco KF Titratorと接続するためのケーブル、電力供給に使用
6.02117.000
USB 電源装置 5 V / 2.1 A946 Portable VA Analyzer 用の USB 充電装置。Power supply unit for the power supply of the 6.1115.100 Optrode if there is no USB connector available for this purpose on a Metrohm device (e.g. with older devices).
6.02135.000
946 Portable VA Analyzerの測定スタンド用ケーブル6.02135.010
946 Portable VA Analyzer用コントロールケーブル6.02201.001
スタイラス - MetrohmStylus for instruments with touch user interface
6.02600.000
モジュールキャリアのブランクプレートOMNIS Sample Robot のモジュールキャリア上で空いている面をカバーするためのブランクプレート
6.02600.010
モジュールプレート用ダミーパネル (OMNIS Sample Robot Oven)OMNIS Sample Robot Oven のモジュールプレート上で空いている面をカバーするためのダミーパネル
6.02600.020
ダミーパネル WSM、前部Sample Robot WSM M または L の OMNIS Workstation Module 前部ポジションをカバーするダミーパネルです。OMNIS Workstation Module が後部ポジションにのみ取り付けられている場合、Sample Robot WSM M または L を覆うためにこのダミーパネルが必要となります。
6.02600.030
ダミーパネル WSM、後部Sample Robot WSM M または L の OMNIS Workstation Module 後部ポジションをカバーするダミーパネルです。OMNIS Workstation Module が前部ポジションにのみ取り付けられている場合、Sample Robot WSM M または L を覆うためにこのダミーパネルが必要となります。
6.02601.010
グリッパーフィンガー 43 ~ 65 mm外径が 43 ~ 65 mm のサンプルビーカーを掴むための OMNIS Sample Robot Pick&Place のグリッパーフィンガー。
6.02601.020
グリッパーフィンガー 50 ~72 mm外径が 50 ~72 mm のサンプルビーカーを掴むための OMNIS Sample Robot Pick&Place のグリッパーフィンガー
6.02601.030
グリッパーフィンガー 48~64 mm外径が 48 ~ 64 mm のサンプルビーカーを掴むための OMNIS Sample Robot Pick&Place のグリッパーフィンガー。
6.02601.040
グリッパーフィンガー 28~48 mm外径が 28 ~ 48 mm のサンプルビーカーを掴むための OMNIS Sample Robot Pick&Place のグリッパーフィンガー。
6.02601.050
セプタムバイアルのグリッパーフィンガーGripper fingers for OMNIS Sample Robot Oven for gripping sample vials
6.02621.000
スパナ 4 mm6.02621.030
ルアー工具この工具を使って、ルアーロック接続を簡単に取り付けおよび取り外しできます。ルアーロックコネクタに装着することもでき、その形状により、ルアーコネクタを備えたチューブの取り付けを容易にします。
6.02700.000
Pick&Place モジュールの安全カバーPick&Place モジュールの安全カバー
6.02700.010
OMNIS Sample Robot Oven の安全シールドOMNIS Sample Robot Oven のグリッパー用安全シールド
6.02700.020
WSM 接続プレートThe connector plate connects 2 OMNIS Workstation Modules on a Sample Robot WSM M or L, thus lending it additional stability.
6.02701.000
601601000 用の吸着カートリッジ6.01601.000 OMNIS Bottle Cap 用の吸着カートリッジ
6.02701.010
601601000 用の PTFE パッキングリング (5個)ボトルキャップ multi-use 用の PTFE パッキングリング
6.02703.000
ポンプモジュール「Peristaltik」用の圧迫クリップ 白圧迫クリップを用いて、ポンプモジュール「Peristaltik」中のポンプチューブを固定し、安定させます。
6.02704.000
ワークステーション用チューブクリップ (10個)ワークステーションに接続されているPVCもしくはPTFEチューブの固定用。
6.02705.000
チューブ配管およびケーブル配線Pick&Place モジュールと滴定装置間のチューブおよびケーブル管理のため
6.02706.000
Sample Robot用のケーブルカバーケーブルカバーは、OMNIS Sample RobotのMDLケーブルおよびイーサネットケーブルのコネクタを保護します。
6.02707.000
Mira M-3用キャリングケースMira M-3および全ての付属品のための保護ケース。
6.02707.010
946 Portable VA Analyzer 用のケース946 Portable VA Analyzer および付属品用のケース
6.02707.020
Mira DSのための頑丈なキャリーケースMira DSおよび付属品のための頑丈なキャリーケース
6.02707.030
Misa Ruggedized Carrying CaseRugged carrying case for Misa and all accessories.
6.02707.400
Mira Pおよび付属品のためのキャリーケースMira Pおよび全ての付属品のための保護ケース。
6.02708.000
946 Portable VA Analyzerの測定スタンド用のベースプレート (古いバージョンの装置用)6.02708.010
946 Portable VA Analyzerの測定スタンド用透明リング (古いバージョンの装置用)6.02708.020
946 Portable VA Analyzer の測定スタンド用ベースプレート6.02708.030
946 Portable VA Analyzer の測定スタンド用透明リング602709000
TacticID-1064 ST 高耐久キャリーケースTacticID-1064 ST 用の耐久性の高いキャリーケース
6.02709.010
ストッパーPlastic stoppers, suitable for 2.1001.4220 OMNIS Karl Fischer Titrator.
6.02709.020
セプタムストッパーPlastic septum stopper, suitable for 6014050X0 titration vessel lids.
6.02709.030
ねじニップルPlastic screw nipple, suitable for 6014050X0 titration vessel lids.
6.02709.040
流出防止ストッパー滴定容器用蓋6014050X0用の流出防止ストッパー。
6.02709.050
ガイドスリーブFor fixation of the Polytron in the 601405040 titration vessel upper part.
6.02710.000
OMNISサンプルビーカー75 mL用KF Dis-Cover蓋、25個OMNISサンプルロボットピック&プレイスシステムのサンプルビーカー6.01402.000および6.01402.003でのカールフィッシャー容量滴定法のためのパッキン付き蓋。
6.02710.010
OMNISサンプルビーカー120 mL用KF Dis-Cover蓋、16個OMNISサンプルロボットピック&プレイスシステムのサンプルビーカー6.01400.200、6.01400.300および6.01400.303でのカールフィッシャー容量滴定法のためのパッキン付き蓋。
6.02710.030
OMNISサンプルビーカー75 mL用Dis-Cover蓋、25個OMNISサンプルロボットピック&プレイスシステムの75 mLサンプルビーカー6.01402.000および6.01402.003用Dis-Cover蓋。
6.02710.040
OMNISサンプルビーカー120 mL用Dis-Cover蓋、16個OMNISサンプルロボットピック&プレイスシステムの120 mLサンプルビーカー6.01400.200、6.01400.300および6.01400.303用Dis-Cover蓋。
6.02710.050
OMNISサンプルビーカー250 mL用Dis-Cover蓋、9個OMNISサンプルロボットピック&プレイスシステムの250 mLサンプルビーカー6.01400.000、6.01400.003および6.01400.100用Dis-Cover蓋。
6.02711.000
ペーストスプーンハチミツ、化粧品、油脂、または様々な乳製品などのペースト状物質のカールフィッシャー水分測定での使用に適しています。ペーストスプーンを使用すると、高粘度サンプルの添加が容易になります。他の薬さじと同様に取り扱いが簡単になり、ペーストをカールフィッシャー滴定容器に、容易かつ迅速に、サンプルを損失することなく添加できます。高粘度サンプルを素早く完全に溶解させるために、ホモジナイザーの使用も推奨します。滴定容器用蓋 6014050X0 に対応。
6.02711.010
IC Amperometric Detectorの接地プラグ。アンペロメトリック検出で低電導性溶離液を使用するための接地プラグ。
6.02712.000
Eco Dosimat / Eco Titrator のための保護カバーEco Dosimat / Eco Titrator のディスプレイのための保護カバー。
6.02729.110
限外ろ過セル2858 Professional Sample Processor / 919 IC Autosampler plus を一緒に用いたサンプルのインライン限外ろ過用。シリンジフィルターによる手間のかかる手動フィルタリングに対する代替法。
6.02743.030
PPボトル、50 mL、12 個The 50 mL bottles are mad of polypropylene (PP) plastic and can be used for samples, standards, check standards and rinsing solutions. Production and packaging both take place under sterile and clean room conditions. This guarantees minimum contamination. The sample vessels are subjected to random checks for leachable anions and cations.
6.02743.090
セプタム付きスクリューキャップThe screw cap with septum is perfectly suitable for maintaining samples and standards over an extended time period. Screw cap with septum for bottle, PP, 50 mL (6.02743.030); PE bottle, 125 ml (6.1627.000) and PE bottle, 50 ml (6.1608.100).In the case of the 858 Professional Sample Processor, the coated sample needle made of steel (6.2624.200) or the Pick-up needle (6.2624.100) must be mounted in order to penetrate the septum.
6.02743.100
セプタムなしスクリューキャップ、ID 14.2 mmThe screw cap without septum can be used in combination with the bottle PP, 50 mL (6.02743.030). The stopper with perforation (6.2743.070) can be slid into the hole and seals the bottle. This provides a perfect sealing option if the standard needle (6.2846.010) is used on the 858 Professional Sample Processor.
6.02744.050
ルアーアダプター 内側/M6 外側Adapter for syringe for pre-rinsing the aspiration filter (6.2821.090). The adapter can be screwed onto the aspiration filter. A syringe can be used to rinse the aspiration filter with ultrapure water or eluent.
6.02764.010
62839131 の交換用パッキンReplacement seals for the flow-through cell, 10 mm (62839131), for UV/VIS instruments
6.02801.000
乾燥管用コットンWad of cotton (4 pieces), suitable for OMNIS 601406010 adsorber tube.
6.02813.000
946 Portable VA Analyzer 用のダミーセル装置点検のためのダミーセル
6.02821.000
PRP-X100 Guard保護カートリッジ用ホルダー分析用分離カラムに接続するためのHamilton PRP-X 100 保護カートリッジ用ホルダー
6.02821.010
MetroSil RP 3 Guard/4.0 カートリッジ用カートリッジホルダー分析用分離カラムに接続するためのMetroSil RP 3 Guard/4.0カートリッジ用のホルダー。
6.02850.000
高圧デガッサー高圧デガッサーは、溶離液生成時に発生する水素ガスの除去を行います。
6.02850.100
連続陰イオントラップ連続陰イオントラップ (CT-A) は、溶離液から陰イオン性不純物と炭酸塩を除去します。
6.02850.200
溶離液生成カートリッジ A溶離液生成カートリッジ A (EPC A) は、水の電気分解により、4 mol/L の水酸化物濃縮物から高純度の水酸化溶離液を生成します。陽イオン交換膜は、陽イオンの溶離液への選択的マイグレーションを可能にします。EPC A には、浄水装置と接続させて全自動で稼働可能な超純水が供給されます。
6.03001.120
シリンダーユニット OMNIS 2 mLOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 2 mL。ドージングチューブ、拡散防止ビュレットチップを含む。
6.03001.150
シリンダーユニット OMNIS 5 mLOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 5 mL。ドージングチューブ、拡散防止ビュレットチップを含む。
6.03001.210
シリンダーユニット OMNIS 10 mLOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 10 mL。ドージングチューブ、拡散防止ビュレットチップを含む。
6.03001.220
シリンダーユニット OMNIS 20 mLOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 20 mL。ドージングチューブ、拡散防止ビュレットチップを含む。
6.03001.250
シリンダーユニット OMNIS 50 mLOMNIS 滴定装置、滴定モジュール、もしくはドージングモジュールのためのインテリジェントなシリンダーユニット 50 mL。ドージングチューブ、拡散防止ビュレットチップを含む。
6.03002.150
シリンダーユニット Eco 5 mLEco Dosimat / Eco Titrator のためのシリンダーユニット 5 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.03002.210
シリンダーユニット Eco 10 mLEco Dosimat / Eco Titrator のためのシリンダーユニット 10 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.03002.220
シリンダーユニット Eco 20 mLEco Dosimat / Eco Titrator のためのシリンダーユニット 20 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.03002.250
シリンダーユニット Eco 50 mLEco Dosimat / Eco Titrator のためのシリンダーユニット 50 mL。ドージングチューブ、拡散防止ビュレットチップを含まない。
6.03004.210
シリンダーユニット OMNIS 10 mL スペシャルIntelligent 10 mL cylinder unit for one OMNIS Titrator, Titration Module or Dosing Module. This cylinder unit is especially recommended for the following solutions:Aqueous alkaline solutions; Titrant 5; Silver nitrate solutions; Nonaqueous alkaline solutions; Permanganate solutions; EDTA solutions; Includes dosing tubing and antidiffusion tip.
6.03004.220
シリンダーユニット OMNIS 20 mL スペシャルIntelligent 20 mL cylinder unit for one OMNIS Titrator, Titration Module or Dosing Module. This cylinder unit is especially recommended for the following solutions:Aqueous alkaline solutions; Titrant 5; Silver nitrate solutions; Nonaqueous alkaline solutions; Permanganate solutions; EDTA solutions; Includes dosing tubing and antidiffusion tip.
6.05000.300
付属品キット: CEPAccessory kit for installation of the 948 Continuous IC Module, CEP
6.05001.010
付属品セット ポンプモジュール 「Peristaltik」(2チャンネル)付属品セットにはポンプモジュール「Peristaltik」の洗浄ポンプおよび吸引ポンプの配管に必要なすべてのコンポーネントが含まれています。ルアーコネクタ付きの組み立て済みチューブの他、圧迫クリップとポンプチューブも各2つずつ付属しています。
6.05001.110
付属品キット WSM (1T/2P)この付属品キットには、OMNIS Workstation Module (1T/2P) のポンプモジュールの洗浄ポンプと吸引ポンプのホースのルーティングに必要なコンポーネントがすべて含まれています。ルアーコネクタ付きの組み立て済みチューブの他、圧迫クリップとポンプチューブも各 2 つずつ付属しています。ルアーコネクタを簡単に取り付けるためのツールもセットに含まれています。
6.05001.210
付属品キット WSM (2T/4P)この付属品キットには、OMNIS Workstation Module (2T/4P) のポンプモジュールの 2 台の洗浄ポンプと 2 台の吸引ポンプのホースのルーティングに必要なコンポーネントがすべて含まれています。ルアーコネクタ付きの組み立て済みチューブの他、圧迫クリップとポンプチューブも各 4 つずつ付属しています。ルアーコネクタを簡単に取り付けるためのツールもセットに含まれています。
6.05002.010
OMNISピペット装備OMNISサンプルロボット ピック&プレイスを、ピペット可能なバリエーションに装備し直すための付属品セット一式。このセットは、OMNISサンプルロボットの全てのバージョン (S、M、およびL) に取り付けることが可能です。
6.05300.000
IC機器: Dose-inグラジエント 陽イオン陽イオン分析用Dose-inグラジエントの設置のための付属品セット。
6.05330.010
IC機器: インライン限外ろ過2 - pull modeインライン限外ろ過2 - pull modeのための付属品セット。858 Professional Sample Processor / 919 IC Autosampler plusを伴う使用に。
6.05330.110
IC機器: インライン限外ろ過2 - push modeインライン限外ろ過2 - push modeのための付属品セット。858 Professional Sample Processor / 919 IC Autosampler plusを伴う使用に。インライン希釈 (MIDT) との組み合わせに推奨されるセット。
6.05330.210
IC機器: インライン限外ろ過 2 - MiPTAccessory set to combine Inline Ultrafiltration 2 and MiPT. For use with the 858 Professional Sample Processor.
6.05330.220
IC 機器: フルループ、PP、889 BasicThe IC equipment contains all of the accessory parts necessary for using the peristaltic pump to transfer samples from the 889 IC Sample Center Basic to the ion chromatograph.
6.05330.230
IC 機器: MiPT、889 BasicAccessory set for assembling a Dosino for Partial-Loop-Injection in combination with the 889 Basic (28890030 & 28890040)
6.05330.400
IC 機器、Agilent ICP-MS の接続IC equipment for the connection and bidirectional control of Metrohm IC and Agilent ICP-MS (IC-ICP/MS)
6.05406.000
OMNIS Coulometer(2液型電極付き)用 KFC 機器カールフィッシャー電量滴定用付属品セット一式。
6.05406.010
OMNIS Coulometer(1液型電極付き)用 KFC 機器カールフィッシャー電量滴定用付属品セット一式。
6.05406.050
OMNIS Oven Module の KFT 装置OMNIS Oven Module でのカール フィッシャー容量滴定用付属品セット一式
6.05406.060
OMNIS Oven Module の発生電極 (2 液型電極付き) 付き KFC 機器OMNIS Oven Module の発生電極 (2 液型電極付き) 付きカールフィッシャー電量滴定用付属品セット一式
- 8.000.52968.000.5296フライヤー: 2029 Zinc Process Analyzer
亜鉛濃度が限界値を超えないようにするため、廃水を常時モニタリングすることは多くの産業において重要です。Metrohm Process Analyticsが開発した 2029 Zinc process analyzer は、オンラインで作業するのに最も簡単かつ使いやすいツールです。
その他の言語
- 8.000.52988.000.5298パンフレット: 共に限界を超える - プロセス工業のためのカスタマイズされたオンラインモニタリングソリューション
Metrohm Process Analytics は、プロセス工業において有名な Applikon 社の湿式化学アナライザーのブランド名です。このパンフレットでは、プロセス工業のためのカスタマイズされたオンラインモニタリングソリューションをご紹介します。
その他の言語
- 8.000.52998.000.5299パンフレット: Metrohm Autolab Microcell HC – 電気伝導度測定のための統合システム
液体やポリマー、固体内部液の電気伝導度について研究中ですか?Metrohm Autolab ならびに弊社のパートナー rhd は、適切なワークステーションを構築するための付属品を提供しています。お客様のご要望に合わせて、効率的かつ正確な電気伝導度測定のニーズに応える付属品をご用意しています。
その他の言語
- 8.000.53008.000.5300パンフレット: TitrIC flex – 包括的な水質分析に必要な全てのこと
TitrIC flex は、これまででもっともフレキシブルで信頼がおける、水質分析のための使いやすいシステムです。滴定、直接測定、およびイオンクロマトグラフィー (IC) を組み合わせると、TitrIC flex によって水中に一般的に存在する全てのイオンを測定することができるようになります。当パンフレットでは、メトロームの新型の TitrIC flex システムに関する概要をご覧いただけます。
その他の言語
- 8.000.53128.000.5312スクリーンプリント電極用電極シャフト - VA分析のためのスクリーンプリント電極
電極シャフトにより、あらゆるMetrohm VA Standにてスクリーンプリント電極 (SPE) を用いることができるようになります。ボルタンメトリー微量分析を行う場合でも、あるいはご自身の改良されたセンサーで新たなアプリケーションフィールドを試してみたい場合でも、電極シャフトでSPEを簡単に使うことができます。
その他の言語
- 8.000.53138.000.5313パンフレット: 下水の分析 - 上水および下水の分析におけるノウハウ
有機汚染物質の濃度が高過ぎる場合、それらは多くの工業プロセスを妨げ、問題を引き起こす恐れがあります。Metrohm Process Analyticsは化学分析装置のトップメーカーとして、水サンプルのモニタリングを容易かつ低コストなものにし得る最新鋭のシステムと完全なるソリューションをお届けします。
その他の言語
- 8.000.53148.000.5314パンフレット: 電気化学的研究のための装置
Metrohm Autolab は、電気化学測定機器の基準を確立します。装置は、腐食、エネルギー、環境、センサー、太陽熱を含むほとんどの範囲の用途に適しています。このパンフレットでは、Metrohm Autolab の製品のポートフォリオをご紹介します。
その他の言語
- 8.000.53158.000.5315パンフレット: Metrohm Process Analytics品質サービス
メトローム品質サービスは、単なる分析サービス以上のものを取り扱っています。メトローム品質サービスは、第一に信頼性を重視しています。助言、サービス、サポートの必要な時、お客様のために誰かがいるという信頼性。お客様の分析器に対するサービスとメンテナンス作業への信頼性。お客様の要望に応えるべく時間を取る専門家によるアプリケーションサポートへの信頼性。メトローム品質サービスは、昼夜ノンストップの製造現場環境での日常業務を簡易化し、より安全に、とりわけ予見性をより高めるため邁進しています。
その他の言語
- 8.000.53168.000.5316パンフレット: メトローム識別システムによる国境警備 - スクリーンタッチで危険を迅速かつ正確に検出
税関は、国境警備において重要な役割を果たしています。課題は多様で、その範囲は、偽造品から違法な物質にまで、そして爆発物から有毒物質にまで至る様々な輸入品にまで及びます。メトローム製のMiraハンドヘルド識別システムにより、スクリーンにタッチすることで、これらすべてを安全かつ正確に検出する準備が完了します。
その他の言語
- 8.000.53178.000.5317フライヤー: 2026 Cyanide Analyzer
シアン化水素 (HCN) は、重合体前駆体 (アジポニトリルなど) やキレート剤 (EDTA など) といった様々な重要な化学薬品の製造に用いられる猛毒の可燃性ガスです。HCNは、金の抽出や金属めっきの鉱業にて使用されるシアン化ナトリウムとして、シアン化物誘導体の製造にも用いられます。多くの様々な (製造) プロセスにおけるその役割のため、濃度を注意深くモニタリングすることは極めて重要です。Metrohm Process Analyticsが開発した 2026 Cyanide Process Analyzer は、オンラインで作業するのに最も簡単かつ使いやすい分析ツールです。
その他の言語
- 8.000.53188.000.5318フライヤー: 2029 Hardness Process Analyzer
配管中のスケールや、発電用給水加熱器の腐食を避けるため、給水および廃水流中の硬度を定期的に測定する必要があります。Metrohm Process Analyticsが開発した 2029 Hardness Process Analyzer は、オンラインで作業するのに最も簡単かつ使いやすいツールです。
その他の言語
- 8.000.53198.000.5319フライヤー: 2029 Nickel Process Analyzer、英語
製品の品質を維持し、化学薬品の使用を改善するためには、ニッケルの濃度を念入りにモニタリングすることは極めて重要です。Metrohm Process Analyticsが開発した 2029 Nickel Process Analyzer は、オンラインで作業するのに最も簡単かつ使いやすいツールです。
その他の言語
- 8.000.53208.000.5320フライヤー: 2029 Nitrate/Nitrite Analyzer
硝酸塩/亜硝酸塩濃度が限界値を超えないようにするため、廃水を常時モニタリングすることは多くの産業において重要です。Metrohm Process Analyticsが開発した 2029 Nitrate/Nitrite Process Analyzer は、オンラインで作業するのに最も簡単かつ使いやすいツールです。
その他の言語
- 8.000.53228.000.5322フライヤー: メトロームビジョン、ミッション、バリュー
このフライヤーには、メトローム社のビジョン、ミッション、バリューに関する情報が含まれています。
その他の言語
- 8.000.53238.000.5323パンフレット: 万人の手の届く範囲に分光電気化学を - 2つの技術を組み合わせて研究のための完全なソリューションに
使いやすく、専用の目的のためのソフトウェアによって実験の多くを実施するための高度な装置です。同期された光学的、電子化学的データを取得するための完全なソリューションです。スペクトルは、電気化学プロセスが研究中にシステムにて実施されている最中に取得されます。典型的な用途についてのより詳しい情報や、主な利点をこのパンフレットにてご覧いただけます。
その他の言語
- 8.000.53258.000.5325パンフレット: 水分の分析
メトロームは、滴定分野における世界市場のリーダーとして知られています。カールフィッシャー滴定は、日常的なラボでの作業においてもっとも幅広く用いられる水分分析メソッドの1つであり、正確な分析結果を得られます。サンプル処理量、生産性、および製品の品質を高めるため、近赤外分光法 (NIRS) を用いて水分測定を直接インラインで容易に行うことができます。ラボの分析結果は、NIRスペクトロメーターのための正確な予測モデルを構築するのに用いられます。NIRS分析結果を伴うインライン水分分析は、サンプル採取や化学薬品使用の必要がなく、ほぼリアルタイムに毎秒ごとに生成されます。
その他の言語
- 8.000.53268.000.5326パンフレット: バッテリー用途のための Metrohm Autolab Impedance Station - バッテリー研究の汎用性と効率性
Autolab Impedance Station は、研究成果を複雑化することなく拡充するものです。既存のラボの装置に簡単に組み込める Autolab Impedance Station を用いて、より詳しく正確なデータによってバッテリーの特性解析を改善することができます。このパンフレットでは、Autolab Impedance Station の長所、用途、ならびに仕様をご覧いただくことができます。
その他の言語
- 8.000.53278.000.5327パンフレット: メタン生成を高め、より高い収益を - バイオガスプラントにおけるシンプルかつ迅速で安価な FOS/TAC の測定
FOS/TAC 値は、バイオガスプラントの監視および管理のためのキーパラメータとして幅広く認められています。この値が 0.3 から 0.4 の間に無い場合、メタンの生成が低減し、結果的に事業の収益が減損します。メタン生成の最適化と最高の収益性を保証するために、メトローム製の Eco Titrator を用いて FOS/TAC 値をごく容易にモニタリングすることができます。
その他の言語
- 8.000.53288.000.5328パンフレット: 腐食アプリケーションの製品 - 腐食試験所のためのコンプライアンスと利便性
間違いなくあなたはデータの正確さと再現性に興味をお持ちのことでしょう。また、腐食率を測定し、腐食メカニズムを調査し、被膜の特性を分析し、あるいは最適な腐食防止剤のスクリーニングをしながらも、資源を最大限活用し、効率的で、ことによると自動化されたワークフローを作りたいともお思いでしょう。Metrohm Autolabの、特殊な測定技術有する信頼のおける高性能な電気化学装置および付属品は、腐食研究の世界のすべてをあなたのラボへと送り込みます。結果の再現性や精度を改良しつつ、ラボにおいて腐食プロセスの真の世界を再現し、時間を節約し、研究の可能性を拡張することができます。
その他の言語
- 8.000.53298.000.5329パンフレット: 石油製品および石油添加剤の水分 – ASTM D6304に準じた気化法でカールフィッシャー電量滴定がこれまでになく簡単に
ASTMはメソッドD6304を改訂しました。新しいこの規格メソッドには気化法が含まれています。このメソッドのメリットは相当なものです:KF滴定セルの汚染がない; マトリックス干渉がない; 必要な溶媒がより少量に; より信頼性の高い分析結果、より優れた結果の再現性; 複数サンプルの完全無人連続測定を可能にするオートメーション;
その他の言語
- 8.000.53308.000.5330パンフレット: パルプ製紙産業 - オンライン分光法 (NIR) によるパルプ工場での化学薬品回収の最適化
パルプ工場では、化学薬品の再利用を可能にするだけでなく、パルプ化プロセスの間ずっと実用的なもの (蒸気、電力) を提供することができるため、化学薬品の回収はキープロセスです。このプロセスを最適化することで、顕著なコスト削減と製品品質の向上が可能となります。これは、白液と緑液の組成をリアルタイムでモニタリングすることで実現することができます。近赤外分光法 (NIRS) はリアルタイムでのプロセスコントロールとあらゆる産業環境へのシームレスな統合を保証します。
その他の言語
- 8.000.53318.000.5331パンフレット: 産業用プロセスアナライザー - 多目的のオンライン、インライン、ならびにアットラインの化学分析
メトローム Process Analyzer は、メトロームの名高いラボソリューションを一歩前へと進めます。完全自動、オンライン、カスタマイズ可能なアナライザーは、広範囲にわたる産業のプロセスモニタリングを容易化します。滴定、分光法、イオンクロマトグラフィーおよび電気化学における弊社のコア・コンピタンスを生かし、効率性を最適化し、化学薬品の消費を抑え、より安全な作業環境を整えるプロセス分析のための信頼性の高いソリューションを創造するため、弊社のアプリケーション知識を活用します。
その他の言語
- 8.000.53338.000.5333近赤外分光法 (NIRS) によるポリマーのマルチパラメータ分析 – バルク原料から最終製品までの製造サイクルに沿った、より迅速な品質管理
プラスチックとポリマーのメーカーは今日まで、製品品質のモニタリングに、その大部分を物理的メソッドおよび化学湿式メソッドに頼ってきました。時間がかかるこれらのメソッドの性質により、またインフラストラクチャー (ラボ) とコスト (化学薬品、消耗品) とも関連して、これらのメソッドはポリマー製造プロセスの生産性に悪影響を与えることがあります。メトロームはポリマー工業における供給原料、中間体、最終製品の迅速かつ信頼性の高い日常品質管理に近赤外分光法ソリューションを提供します。メトロームの近赤外分光法ソリューションは分析に化学薬品を必要とせず、品質管理プロセスにて誰でも直接実施することができます。重要な化学的・物理的特性の信頼性の高い結果が瞬時に提供されます。
その他の言語
- 8.000.53348.000.53342026 Preventive Maintenance
プリヴェンティブ・メンテナンスは、メトロームのメンテナンスの取り決めの一部とすることが可能であり、重要なものに重点をおくことができます – パフォーマンスです。重要なコンポーネントは摩耗が進み、時の流れとともに汚れ、これはコンポーネントの故障やパフォーマンスのバラつきが生じる原因となります。Metrohm Process Analytics は、少なくとも一年に一回プリヴェンティブ・メンテナンスを行うことを推奨しています。
その他の言語
- 8.000.53358.000.53352029 プリヴェンティブ・メンテナンス
プリヴェンティブ・メンテナンスは、メトロームのメンテナンスの取り決めの一部とすることが可能であり、重要なものに重点をおくことができます – パフォーマンスです。重要なコンポーネントは摩耗が進み、時の流れとともに汚れ、これはコンポーネントの故障やパフォーマンスのバラつきが生じる原因となります。Metrohm Process Analytics は、少なくとも一年に一回プリヴェンティブ・メンテナンスを行うことを推奨しています。
その他の言語
- 8.000.53368.000.5336OMNIS meets CUBIS® – Sartorius 社製ラボ用天秤のシームレスな統合
Sartorius 社製の CUBIS® ハイエンドラボ用天秤は、今や OMNIS プラットフォームに完全に統合されその一部となりました。規制上の要件、プロセス設計、またはネットワーク統合への対応 - OMNIS の CUBIS® の統合性は、性能や有用性に関して、より高度な規格に準拠しています。
その他の言語
- 8.000.53378.000.53372029 Aluminum Analyzer – Metrohm Process Analytics製
アルミニウムは最も豊富な地殻の金属元素 (8%) であり、非常に反応性の高い卑金属です。これは低密度で、電気伝導度と熱伝導率が高く、高い耐腐食性を有します。これらの顕著な特性が理由で、この金属は建築、航空機、自動車の構造材料としてよく使用されます。また、半導体の金属合金の生産において、ならびに飲料水供給施設で凝集剤としても使用されます。Metrohm Process Analyticsの2029 Aluminum process analyzerはAlオンライン測定に最も簡単かつ使いやすいツールです。当パンフレットでは2029 Aluminum Analyzerの長所をご紹介します。
その他の言語
- 8.000.53398.000.53392035 Hardness Process Analyzer
塩素の製造や水の脱塩などといった様々な産業電解プロセスには、高価な電解膜の使用が必要とされます。それゆえ、塩水の浄化は 皮膜を維持し、電解中の消費電力を抑えるために避けられない工程となりました。硬度 (カルシウムおよびマグネシウム) などといった不純物のレベルは、2つの処理工程にて抑えられます。イオン交換樹脂を用いた2次処理の後、塩水の不純物の濃度を1000倍低減することができます。Metrohm Process Analytics 製の 2035 Hardness Process Analyzer は、超高純度塩水においてオンラインで硬度を測定するのに理想的なソリューションです。
その他の言語
- 8.000.53408.000.5340Metrohm Process Analytics - オンライン、インライン、ならびにアットラインプロセス分析のソリューションプロバイダ。
Metrohm Process Analytics によって設計、製造されたプロセスアナライザーは、幅広い分野の産業におけるプロセスモニタリングに好んで用いられるソリューションです。プロジェクトの要求や予算がいかなるものであっても、Metrohm Process Analytics は適切なソリューションを用意しています。我々は、電気化学、イオンクロマトグラフィー、イオン選択測定、測光法、分光法、ならびに滴定のための分析システムを提供いたします。プロセス分析において分析技術を実行する4つの主な方法の要点がこのパンフレットにて述べられており (オンライン、インライン、アットライン、ならびにオフライン)、実行する内容に応じて複数の利点を享受することができます。
その他の言語
- 8.000.53418.000.5341フライヤー メトロームインライン限外ろ過
その他の言語
- 8.000.53428.000.5342パンフレット - Eco KF Titrator
Eco Titratorは、食品から化学薬品、塗料、インクなどまでに至るまでのサンプルマトリックス中の水分測定のための手ごろな価格のソリューションです。
その他の言語
- 8.000.53448.000.5344パンフレット - 安全な操作
その他の言語
- 8.000.53458.000.5345高スループット、低コスト - ルーチン分析を自動化しましょう
その他の言語
- 8.000.53478.000.5347カラムプログラム
メトロームは、イオンクロマトグラフィーのすべての分野に適した分離カラムを提供します。このカタログは、メトロームの分離カラムの概要を示しています。
その他の言語
- 8.000.53488.000.5348VIONIC powered by INTELLO パンフレット
その他の言語
- 8.000.53498.000.53492060 MARGA
その他の言語
- 8.000.53508.000.5350パンフレット: 2060 IC Process Analyzer
その他の言語
- 8.000.53518.000.5351パンフレット: パルプおよび製紙産業
その他の言語
- 8.000.53528.000.5352メトローム低容量インライン透析
その他の言語
- 8.000.53538.000.5353パンフレット: 2029 Manganese Analyzer
その他の言語
- 8.000.53558.000.5355パンフレット: 2026 Alkalinity Analyzer
その他の言語
- 8.000.53568.000.53562026 Ammonia Analyzer
その他の言語
- 8.000.53578.000.5357パンフレット: 2026 Fluoride Analyzer
その他の言語
- 8.000.53598.000.5359環境試験産業 II - 携帯型水処理装置のためのオンラインアナライザー
その他の言語
- 8.000.53618.000.5361蒸気回路のオンライン腐食モニタリング
その他の言語
- 8.000.53628.000.5362フライヤー: VIONIC Specifications
VIONIC powered by INTELLO の選択された仕様。
その他の言語
- 8.000.53648.000.5364プロセス用近赤外分光分析計のためのサンプル溶液
その他の言語
- 8.000.53658.000.5365フライヤー: 夢のセンサー、そして我々は共にそれを実現します
電気化学溶液のカスタム製造および大量生産
その他の言語
- 8.000.53668.000.5366フライヤー 夢のセンサー、そして我々は共にそれを実現します (研究者)
その他の言語
- 8.000.53678.000.5367パンフレット:石油および石油化学産業
原油は、炭化水素とその他の化合物から構成される非常に複雑な混合物であり、脱塩、蒸留、脱硫、転化によって液化ガスやガソリン、ディーゼル、暖房用燃料、潤滑剤などの高品質の炭化水素や、その他の多様な製品に変換されます。精製プロセスへの要求は厳しく、正確かつ信頼性の高い分析が必要となります。このパンフレットでは、滴定、イオンクロマトグラフィー、ボルタンメトリー、CVS、または NIRS やラマン分光法などのメソッドによる分析技術をラボや生産プロセスに統合させるためのさまざまな関連パラメータの概要を紹介しています。この概要は、様々な生産手順と最終生成製品に従って構成されています。
その他の言語
- 8.000.53688.000.5368パンフレット 2060 Human Interface
The 2060 Human Interface (HI) is a reliable industrial process controller with a rugged enclosure and high-definition touch screen. It is part of the 2060 process platform, which means that it is highly versatile and flexible in accordance to Metrohm Process Analytics design philosophy.
その他の言語
- 8.000.53698.000.5369フライヤー パンの化学的性質
pH値と滴定可能な酸のモニタリングは、これら二つの値がパン粉の品質とパンの風味に影響を与えることから、極めて重要とされています。この分析を用いたメトロームのサポートをご覧ください。
その他の言語
- 8.000.53708.000.5370パンフレット 2045 TAN Analyzer
その他の言語
- 8.000.53718.000.5371パンフレット Eco Coulometer
Eco Coulometer は、油、薬剤、プラスチック等の母材に含まれる微量の水分を測定するための手頃な価格の溶液です。不溶性物質用としては860 KF Thermoprep または885 Compact Oven Sample Changer を接続し、サンプルを加熱して電量分析用KFセルに水分を直接送ることができます。
その他の言語
- 8.000.53738.000.5373ブローバックフィルター付き沈降タンク - 分析における干渉の防止
Metrohm Process Analytics による Sampling Conditioning Systems (SCS)
その他の言語
- 8.000.53748.000.5374ブローバックフィルター - いかなるサンプル流もセルフクリーニング
Metrohm Process Analytics による Sampling Conditioning Systems (SCS)
その他の言語
- 8.000.53758.000.5375減圧ユニット - プロセスアナライザーのための一定の流量
Metrohm Process Analytics による Sampling Conditioning Systems (SCS)
その他の言語
- 8.000.53768.000.5376パンフレット オートフォーカススタンドオフアタッチメント
その他の言語
- 8.000.53778.000.5377フライヤー OMNIS Software Long-Term Support (LTS)
このフライヤーでは、OMNIS Software の OMNIS長期間サポートバージョンに関する概要とより詳しい情報をご覧いただけます。
その他の言語
- 8.000.53788.000.5378フライヤー DropSens custom production、英語
その他の言語
- 8.000.53798.000.5379パンフレット Compliance Management
このパンフレットでは、Metrohm のミッション、品質方針、行動規範、企業の社会的責任などについて説明しています。
その他の言語
- 8.000.53808.000.5380パンフレット Combustion IC TEI
The CIC solution from Metrohm combines a combustion module (oven unit) from Trace Elemental Instruments (TEI) with an absorption module and an IC system from Metrohm.
その他の言語
- 8.000.53818.000.5381パンフレット Degassing unit
その他の言語
- 8.000.53828.000.5382フライヤー: Settler unit – 粒子の除去による分析向上
このサンプルコンディショニングシステムは、プロセスアナライザーへの導入前に、入れられたサンプルから粒子 (粒子材料) と固形物を沈降させるために設計されています。
その他の言語
- 8.000.53868.000.5386パンフレット ProTrode pH sensors
Metrohm Process Analytics のインライン pH センサーを選択することで、プロセスコントロールのより高い効率と最適化が保証され、長年のアプリケーション知識と信頼できる専門家によるサポートが得られます。«ProTrode センサー»は、Metrohm Process Analytics のインラインセンサーをさらに進化させたものです。
その他の言語
- 8.000.53878.000.5387フライヤー ProTrode 250/350 センサー
ProTrode 250 および 350 は、厳しいセンサー仕様が要求される化学プロセスにおいてインライン pH 測定を行うための、温度センサー (Pt1000) を内蔵した複合型 pH センサーです。どちらも予め加圧されたセンサーなので、煩雑な作業を行わずに 4 bar までのプロセス条件で測定できます。
その他の言語
- 8.000.53888.000.5388フライヤー ProTrode 200/300 センサー pharma
ProTrode 200 および 300 は、バイオテクノロジーや製薬プロセスのインライン pH 測定を行うために設計された温度センサー (Pt1000) 内蔵の複合型 pH センサーです。どちらも、銀イオンがプロセスサンプルに溶出するのを防ぐために銀の捕捉剤を使用して設計されています。
その他の言語
- 8.000.53898.000.5389パンフレット Combustion IC、Analytik Jena、ドイツ語
Metrohm の CIC 溶液は、 Analytik Jena (AJ) の Combustion Module に、Metrohm の吸収モジュールと IC システムを組み合わせたものです。
その他の言語
- 8.000.53918.000.5391パンフレット: OMNIS Client/Server
このパンフレットでは、OMNIS Client/Server に関する詳細情報をご覧いただけます。OMNIS Client/Server は、企業がグローバルにデータ、装置、SOP を連携し、管理することを可能にします。OMNIS Client/Server では、どのクライアントも他のクライアントが作成した分析や結果にアクセスできます。マウスを一回クリックするだけでクライアント間のデータを交換できます。
その他の言語
- 8.000.53928.000.5392吸着性有機結合ハロゲンの迅速なモニタリング
有機ハロゲン化合物は広く分布し、難分解性で、ヒトや環境に有害な可能性があります。新しい DIN 38409-59 は、燃焼式イオンクロマトグラフィー(CIC)を用いて吸着性有機結合ハロゲン(AOX)を迅速に測定するための標準化および認証されたメソッドを提供します。既存の規格とは異なり、新しい DIN では、合計パラメータ AOX に加えて、吸着性有機結合ハロゲン(AOF、AOCl、AOBr、AOI)の選択的な測定が可能です。特に AOF 測定は、ノンターゲットの PFAS モニタリングに迅速かつ経済的な溶液を提供します。Metrohm は、包括的な AOX 分析のための費用対効果の高い溶液を提供します。
その他の言語
- 8.000.53938.000.5393NIRS 防爆アナライザー – 危険領域での安全な操作: Metrohm Process Analyticsの専門知識による優れた実践
高濃度の可燃性ガス、有害な蒸気、または粉塵が生じる場所では、装置を安全に操作し、爆発を引き起こさないことが重要です。防爆仕様のプロセスアナライザーは、防爆電気領域等級に準拠して構成されています。(ATEX Class I, Div. 2/Class I, Div. 1…)。Metrohm Process Analytics はこのような環境に対し、湿式化学 (滴定など) および分光法 (近赤外分光法、«NIRS» など) のための完全自動化された (オンラインまたはインライン) ソリューションを提供します。このパンフレットでは Metrohm Process Analytics が、いかに危険な環境において近赤外分光法 (NIRS) プロセスプロジェクトを正常に実施するかについて紹介しています。
その他の言語
- 8.000.53988.000.5398フライヤー How is your Metrohm System?
その他の言語
- 8.000.53998.000.5399MagIC Net - Update 4.0
その他の言語
- 8.000.54018.000.5401パンフレット Safety First
このカタログでは、防衛と安全保障部門の Metrohm のアプリケーションノウハウについて収集・紹介しています。
その他の言語
- 8.000.54028.000.5402フライヤー Hyphenated EC-Raman Battery Solution
陽極材料/陰極材料とその変換に関する同時構造機能情報のための電気化学技術と現場でのラマン分光法の組み合わせの詳細についてご覧ください。このパンフレットでは、ソリューションをカスタマイズできるソリューションと様々な付属品を紹介しています。
その他の言語
- 8.000.54038.000.5403フライヤー Hyphenated EC-Raman Solutions Corrosion
ラマンと電気化学の組み合わせによって、腐食現象に関して二元的な視点を得ることができます。Metrohm は、より迅速な測定を実現する腐食研究者に二つのパッケージを提供します: 煩わしいセットアップや複雑なトレーニング、または同期測定に関する心配は不要です。このパンフレットでは、研究のために正しい選択をする手助けをするソリューションとその仕様について紹介しています。
その他の言語
- 8.000.54048.000.5404フライヤー Hyphenated EC-Raman Electrocatalysis
ラマン分光法と電気化学の組み合わせによって、作用中の電気触媒の詳細に関する理解を深めることができます。Metrohm は、より迅速な測定を実現する電気触媒研究者に二つのパッケージを提供します: 煩わしいセットアップや複雑なトレーニング、または同期測定に関する心配は不要です。このパンフレットでは、研究のために正しい選択をする手助けをするソリューションとその仕様について紹介しています。
その他の言語
- 8.000.54058.000.5405パンフレット Product Highlights 2022
本冊子では、Metrohm のポートフォリオの中から、製品のハイライト 2022 の概要をご紹介しています。
その他の言語
- 8.000.54068.000.5406パンフレット μStat-i MultiX
このパンフレットは、マルチユーザー、ならびに学際的電気化学研究のための μStat-i MultiX バイポテンショスタット、ガルバノスタット、マルチチャンネルインピーダンスアナライザー (MultiplEIS® 技術を伴う) に関する情報を提供する資料です。主な特徴、主要なメリット、コンフィグレーションのオプション、ソフトウェアと技術データについての情報を提供します。
その他の言語
- 8.000.54078.000.5407パンフレット: OMNIS Software 技術データ
この技術データは、OMNIS Software (Client/Server と Stand-Alone) およびそれに関連するソフトウェアライセンスのシステム要件に関する詳しい情報を提供します。
その他の言語
- 8.000.54088.000.5408フライヤー Pure Corrosion、英語
VIONIC powered by INTELLO は、単一の装置内で組み合わされた最高の仕様を提供します。このフライヤーは、腐食研究者に、関連する仕様と特長をご紹介します。
その他の言語
- 8.000.54098.000.5409フライヤー Pure Electrocatalysis
VIONIC powered by INTELLO は、単一の装置内で組み合わされた最高の仕様を提供します。このフライヤーは、電気触媒研究者に、関連する仕様と特長をご紹介します。
その他の言語
- 8.000.54108.000.5410フライヤー Pure Energy、英語
その他の言語
- 8.000.54118.000.5411フライヤー Pure Sensors、英語
VIONIC powered by INTELLO は、単一の装置内で組み合わされた最高の仕様を提供します。このフライヤーは、センサー研究者に、関連する仕様と特長をご紹介します。
その他の言語
- 8.000.54128.000.5412パンフレット m-oem、英語
その他の言語
- 8.000.54138.000.5413パンフレット Raman concatenation、英語
その他の言語
- 8.000.54148.000.5414パンフレット VIONIC Hardware Discovery
その他の言語
- 8.000.54158.000.5415パンフレット: 2060 The NIR Analyzer
2060 The NIR Analyzer – 進化した分光法による化学パラメータの、24 時間 365 日の工場内オートメーションとオンラインモニタリングのための完璧なソリューション。
その他の言語
- 8.000.54168.000.5416Metrohm AeRosol Sampler «MARS»
空気汚染の深刻化にともない、エアロゾルにおける化学組成のモニタリングの重要性が高まってきています。Metrohm AeRosol Sampler、つまり MARS は、エアロゾルに含まれるイオンを測定するためのシンプルなソリューションです。
その他の言語
- 8.000.54178.000.5417パンフレット OMNIS コンプライアンス パッケージ、英語
データ完全性は、完全な透明性とトレーサビリティを提供するそのライフサイクル全体において、データは完全かつ一貫性があり、正確であることを要求します。FDA、WHO、PIC/S、およびGAMPが用いているデータ完全性に関する産業ガイドラインは、それぞれ頭文字ALCOAもしくはALCOA+にて表されます。弊社のOMNIS Softwareは、ALCOAおよびALCOA+で規定されたこのようなクオリティを全てのデータが満たすことを保証し、お客様に安心感を提供します。
その他の言語
- 8.000.54188.000.5418フライヤー OMNIS サードパーティーデータの統合、英語
このフライヤーでは、OMNIS サードパーティーデータのOMNIS Softwareへの統合について概要および詳細情報を記述しています。
その他の言語
- 8.000.54208.000.5420パンフレット IBEX CBRNE Robot
その他の言語
- 8.000.54218.000.5421PTRam アナライザー - Metrohm プロセス ラマン アナライザーによるモニタリングとプロセス最適化
Metrohm Process Analytics の PTRam は、化学産業、石油化学産業、ならびに製薬産業における製品開発とプロセス開発のために設計された、19インチのサンプルラックに取り付け可能なラマンアナライザーです。これは製品開発やプロセス開発の中でご使用いただけます。
その他の言語
- 8.000.54228.000.5422Metrosensor 電極
Metrohm は幅広い用途のセンサー製品を多数ご提供しています。このカタログでは、Metrosensor 電極の概要を示しています。主な内容は以下の通りです。どの電極がどのアプリケーションに向いているか?; Metrosensor 電極 - 概要; 付属品; Metrosensor はどのように製造されているか?; 理論的な基盤; 技術データ;
その他の言語
- 8.000.54238.000.5423Intelligent Metrohm Process Analytics Control Technology «IMPACT» ソフトウェア
このパンフレットでは、Metrohm Process Analytics の IMPACTソフトウェアに関する概要とより詳しい情報をご覧いただけます
その他の言語
- 8.000.54258.000.5425Flyer: MSA Standard GLOBAL
Customize your personal service and preventive maintenance solution and benefit from reliable protection of your Metrohm system with maximum flexibility.
その他の言語
- 8.000.54268.000.5426Flyer: MSA Standard Pharma GLOBAL
Customize your personal service and preventive maintenance solution, always with a focus on compliance and benefit from reliable protection of your Metrohm system with maximum flexibility for the regulated environment.
その他の言語
- 8.000.54278.000.5427Flyer: MSA Prime GLOBAL
Your peace of mind solution with maximum insurance for your Metrohm system. Benefit from premium protection with full cost control.
その他の言語
- 8.000.54288.000.5428Flyer: MSA Prime Pharma GLOBAL
Your peace of mind solution with maximum insurance for your Metrohm system, always with a focus on compliance. Benefit from premium protection with full cost control for the regulated environment.
その他の言語
- 8.000.54298.000.5429バッテリーの研究と生産
このパンフレットは、最新の電気化学技術から滴定、カール フィッシャー滴定、イオンクロマトグラフィー、ならびに電圧電流法といった確立された方法に至るまで幅広い範囲のメソッドをカバーしています。概要は、用途のキーフィールドエリアを定義する特定のテーマに沿って構築されています:原材料 (リチウム塩中の不純物、水分、溶出した陰イオンと陽イオンなど); 陽極・陰極材料 (水分、残留アルカリなど); 電解液、添加物、および溶媒 (電解液成分、拡散係数、イオン輸率など); セパレータ (水分、マクミラン数); 使用済みバッテリー (容量と電力、サイクル性能、クーロン効率など);
その他の言語
- 8.000.54308.000.5430パンフレット: 炭素材料の分析
この小さなパンフレットは、ラマン分光法から、最新の電気化学技術、および滴定、カール フィッシャー滴定やイオンクロマトグラフィーのような確立された方法に至るまで幅広い範囲のメソッドをカバーしています。概要は、関連する規範および基準を含む重要な分析パラメータを定義する特定の炭素材料に従って構成されています:グラフェン (構造物性、酸素含有量 (Boehm滴定)、電気化学的評価など); カーボンナノチューブ (結晶構造の不規則性、付加電位の依存性における特性評価など); グラファイト (特性評価、リチウムのインターカレーションとデインターカレーション、水分など); カーボンブラック (電気化学的特性評価、ヨウ素吸着量、水分など); 硬質炭素 (ナトリウムイオンの挿入および脱挿入、水分;
その他の言語
- 8.000.54318.000.5431分光電気化学アプリケーションブック
電気化学的な知識と方法に文字通り光を放ちます。光学的および電気化学的信号の両方の記録と同時に新規データの取得を可能とする分光電気化学法によって、より多くの情報の分析が可能になります。
その他の言語
- 8.000.54328.000.5432Metrohmの分光法関連製品フライヤー!
本フライヤーでは、NIRおよびラマン分光法のためのMetrohmポートフォリオの中から概要をご紹介しています。
その他の言語
- 8.000.54338.000.5433パンフレット OMNIS Software
このパンフレットでは、すべての OMNIS Software に関する概要とより詳しい情報をご覧いただけます。
その他の言語
- 8.000.54348.000.5434お客様のインタビュー «NIR 分光法を用いた排泄物の分析»
ピティエ・サルペトリエールのシャルル・フォワ大学病院(フランス)のローランス・バルボ・トリストラム氏は、生体化学を専門とする医学生物学士およびPhD薬剤師として活躍しています。DS2500 Solid Analyzerを使用する彼女がその体験を共有してくれます。
その他の言語
- 8.000.54358.000.5435お客様のインタビュー «NIR 分光法を用いたポリマーおよびポリオールの分析»
煙台市(中国)の万華化学集団に勤務するグオ・ユエンフェン氏は、分析法の実施と検証を担当するテクニカルエンジニアです。仕事でMetrohm NIRS XDS RapidLiquid Analyzerを使用する彼にその経験についてお話しいただきました。
その他の言語
- 8.000.54368.000.5436最新の USP メソッドを!
このフライヤーでは、USP によって最近更新された研究論文の概要を紹介しています。USP では現在、API、不純物、添加剤における数多くの製剤分析のためにイオンクロマトグラフィー法の適用を要求しています。
その他の言語
- 8.000.54388.000.5438パンフレット: マイクロボア イオンクロマトグラフィー
2ミリメートルのカラム、2ミリメートルのキャピラリーおよびセル容量を減らした新型検出器が Metrohm のマイクロボア イオンクロマトグラフィー用システムの中核を成しています。マイクロボア イオンクロマトグラフィーの大きな特徴は、溶離液の消費量を低減し、標準ボアシステムと比較してコストを最大75%削減できることにあります。当社の新型マイクロボア検出器はメタンスルホン酸(MSA)といった扱いが難しい溶離液にも対応します。この優れた特徴を誇る新型マイクロボアICシステムは新たな分野での用途での使用を可能とし、ハイエンド質量検出器との連結に最適です。
その他の言語
- 8.000.54428.000.5442麻薬の密輸と流通との闘い
このフライヤーでは、麻薬の密輸および流通の防止対策用ツールとして使用可能な携帯式ラマンシステム MIRA XTR DS の機能およびメリットをまとめています。
その他の言語
- 8.000.54438.000.54432 分以内でポリマーID 検証を
このインタビューでは、携帯ラマン分光計によるポリマーペレットの ID 検証 (原料識別、RMID) のメリットについて説明しています。
その他の言語
- 8.000.54448.000.5444パンフレット Autolab IMP
Autolab IMP。EIS 機能と NOVA ソフトウェアを搭載したコンパクトな Autolab ポテンショスタット/ガルバノスタットで教育・研究用電子化学ラボをレベルアップします。
その他の言語
- 8.000.54458.000.5445Autolab IMP。フル仕様
Autolab IMP。EIS 機能を搭載したコンパクトな Autolab ポテンショスタット/ガルバノスタット。フル仕様
その他の言語
- 8.000.54468.000.5446パンフレット: OMNIS による温度滴定
温度滴定は、電位差滴定を適用できない場合、つまり例えば適切な電位差滴定センサーがない場合などに特に便利な方法です。 dThermoprobe および dThermoprobe HF といったセンサーはメンテナンスを不要とし、食用油における全酸価 (TAN) の測定、食品に含まれるナトリウムの測定、電気めっき槽内の酸混合物の分析など、さまざまな用途に適しています。センサーには感度の高いサーミスタが装備されており、滴定中のエンタルピーの変化を測定することができます。温度滴定機能は OMNIS に統合されていますので、ハードウェアコンポーネントを追加する必要はありません。OMNIS システムの中で複数の電位差滴定分析と温度滴定分析を平行して実行することが可能です。より高いスループット量が要求される場合には、 OMNIS Sample Robot を使用することができます。
その他の言語
- 8.000.54488.000.5448パンフレット: OMNIS Titrator
OMNIS Titrator は、モジュール式滴定プラットフォームです。滴定アプリケーションの使いやすさと安全性を向上し、ニーズに合ったどのアプリケーションとでも拡張することができます。このパンフレットでは、新しい OMNIS Titrator に関する詳細情報をご覧いただけます。
その他の言語
- 8.000.54498.000.5449パンフレット: Metrohm DropSens ポートフォリオのハイライト
このパンフレットでは、Metrohm の主要な Dropsens 製品の概要を紹介しています。
その他の言語
- 8.000.54508.000.5450パンフレット: OMNIS Sample Robot
OMNIS Sample Robotにより、モジュール式プラットフォームを拡張し、サンプル処理量を新たなレベルへと引き上げることができます。省スペースを図り、独特の柔軟さを楽しんで、比類ない性能をご堪能ください。このパンフレットでは、新しいOMNIS Sample Robotに関する詳細情報をご覧いただけます。
その他の言語
- 8.000.54518.000.5451パンフレット: Eco Titrator - 品質管理におけるリスクを避けましょう
新型の Eco Titrator で滴定をシンプル、安全かつ確実に行えるので、誰にでも実行できて - しかも正しい結果を得られます!このパンフレットでは、メトロームの新型の Eco Titrator に関する概要をご覧いただけます。
その他の言語
- 8.000.54548.000.5454パンフレット: 半導体製品
汚れがウェハーの故障につながることがあることなどから、半導体の生産には高品質標準が求められます。原材料(単結晶シリコン)を処理して最終的に回路に内蔵させる加工作業にはいくつかの工程手順が必要になります。最終製品の高い品質を確保するには、どの手順でも非常に慎重な作業が必要になります。このパンフレットでは、滴定、イオンクロマトグラフィー、ボルタンメトリー、CVS、または NIRS やラマン分光法などのメソッドによる分析技術をラボや生産プロセスに統合させるためのさまざまな関連パラメータの概要を紹介しています。この概要はそれぞれの生産段階に応じて記載されています。
その他の言語
- 8.000.54558.000.5455フライヤー: 930/940 IC 装置の注文番号
その他の言語
- 8.000.54568.000.5456パンフレット: OMNIS Titration
このパンフレットでは、Metrohm の新たな分析システムである OMNIS に関する詳細情報をご覧いただけます。このシステムは、いつでもあらゆるレベルで、ユーザーファーストを指針とするモジュラー型プラットホームに基づいています。つまりそれはどういうことなのでしょうか、そしてどのようなメリットを OMNIS は提供するのでしょうか?以降のページでご覧いただきましょう!
その他の言語
- 8.000.54578.000.5457フライヤー: ORP Kit
このフライヤーでは、ORP Kit の重要な機能やコンポーネント等の情報を紹介しています。
その他の言語
- 8.000.54588.000.5458フライヤー: Metrohm Illicit と一般化学薬品ラマンライブラリ
Metrohm Illicit と一般化学薬品ラマンライブラリに関する顧客用フライヤー。
その他の言語
- 8.000.54598.000.5459パンフレット: OMNIS NIRS - 品質管理を迅速かつ簡単に、効率よく
OMNIS NIRSは、OMNISプラットフォーム上で機能する高性能な近赤外分光法製品ファミリーです。このパンフレットでは、ラボ作業を迅速かつ簡単に、より高効率よくするための主要機能の概要を紹介しています。
その他の言語
- 8.000.54608.000.5460パンフレット: Metrohm における職業訓練
その他の言語
- 8.000.54618.000.5461ASTM D8192 による水の硬度の測光滴定
このパンフレットでは、ASTM D8192-23 に則した自動測光滴定による総合硬度と Ca/Mg 硬度の測定について説明しています。このメソッドは手動による目視の終点滴定の代替法となります。
その他の言語
- 8.000.54628.000.5462フライヤー: DropStat Plus
このフライヤーでは、お客様の最終アプリケーションに合わせてカスタマイズできるスタンドアローン型の電気化学式リーダー、DropStat Plus について紹介しています。
その他の言語
- 8.000.54638.000.5463パンフレット:微量分析をシンプルかつ効果的に
このパンフレットでは、Metrohm でお取り扱いしているすべての SERS 基板を紹介しています。ここでは SERS 分析における基板の役割、Metrohm をお使いのお客様にとってのメリットおよび SERS 基板に対応しているアプリケーションについて説明しています。
その他の言語
- 8.000.54648.000.5464フライヤー: SAVANNAH m-oem ラマンモジュール
カスタム可能な統合型 SAVANNAH m-oem ラマンモジュールを簡単なフライヤーの中で紹介しています。
その他の言語
- 8.000.54658.000.54652060 TI Process Analyzer – プロセス分析における難題に対する最大限の柔軟性
2060 TI Process Analyzer は、滴定、動的な標準添加、微分吸収比色分析、直接測定(pH、電気伝導度、温度など)を可能とする用途の広いプロセス用湿式化学分析装置です。このメソッドの組み合わせによる分析の柔軟性により、複数のパラメータを同時分析でき、ほぼすべてのオンライン分析のニーズに応えます。
その他の言語
- 8.000.54668.000.5466フライヤー: H2PERMKIT
このフライヤーには、ASTM G148 に準拠した水素透過実験を実施するための H2PERMKIT に関する情報が含まれています。
その他の言語
- 8.000.54678.000.5467パンフレット: 202X Process Analyzers - パワフルかつコンパクトなシングルメソッドオンラインアナライザー
202X Process Analyzers は、プラグアンドプレイ アプローチ設計のためセットアップが迅速かつ手間なく行えます。これら汎用性の高いプロセスアナライザーでは、2 つまでのサンプル液流における滴定または光度測定により、様々な検体を測定することができます。
その他の言語
- 8.000.54728.000.5472パンフレット: 近赤外分光法の新時代
OMNIS NIRS パンフレット - XDS と DS2500 に続く OMNIS NIRS。
その他の言語
- 8.000.54738.000.5473フライヤー: Metrohm Comprehensive ラマンライブラリ
Metrohm Comprehensive ラマンライブラリは、16,200 種を超える物質のコンプリートコレクションであり、様々な産業のユーザーに物質の識別を簡易化し、ハンドヘルド型ラボ用ラマンのアプリケーション範囲を拡張します。違法物質・一般物質ライブラリおよび USP 認定化合物ライブラリを基礎として作成されたこのライブラリは、入手可能な最大のラマンスペクトルコレクションの一つです。このライブラリは Metrohm 品質性能のために Metrohm 装置で作成されています。その結果、532、785、1064 nm で作動するハンドヘルド型ラボ用システムのラマンポートフォリオ全体にわたる卓越した精度を実現しました。
その他の言語
- 8.000.54748.000.5474パンフレット:燃料の品質管理 - NIR プリキャリブレーションによる迅速な結果
Metrohm は、ガソリン、ディーゼル、ケロシンならびにリフォーメートにおける複数のキーパラメータを ASTM 6122 に準じて測定するためのターンキーソリューションを提供します。測定装置は、実際のプロダクトスペクトルの大規模なコレクションに基づくプリキャリブレーションモデルを備えた DS2500 リキッド近赤外アナライザーで構成されています。このソリューションにより、燃料の製造者、ならびに精製所や石油貯蔵地区、試験機関などのような燃料貯蔵設備は、時間を節約し、分析にかかるコストを削減することができます。
その他の言語
- 8.000.54758.000.5475パンフレット: OMNIS Coulometer および OMNIS Sample Robot Oven
新型 OMNIS Coulometer および OMNIS Sample Robot Oven のパンフレット
その他の言語
- 8.000.54768.000.5476データシート: Metrohm 装置と tiamo™ のバージョンとの互換性
この文書では、tiamo 滴定ソフトウェアで適切な Metrohm 装置のコントロールに最低限必要な tiamo ソフトウェアバージョンをご覧いただけます。
その他の言語
- 8.000.54778.000.5477パンフレット: 2060 Raman Analyzer
2060 Raman Analyzer – 総合的なプロセスモニタリングのための分析精度の解放
その他の言語
- 8.000.54798.000.5479パンフレット: Product Highlights 2024
このパンフレットでは、2024 年 Metrohm の製品ポートフォリオのハイライトをご紹介します。
その他の言語
- 8.000.54818.000.5481フライヤー: ラボの完全な制御
バイオテクノロジー分野の研究のためのファインケミカルのメーカーであるIris Biotech は、入荷原料の品質チェックに MIRA P Raman ハンドヘルドスペクトロメーターを使用しています。このフライヤーはその研究所所長とのインタビューを基にしており、RMID をハンドヘルドラマン分光法で統合することに決定した理由について説明しています。
その他の言語
- 8.000.54828.000.5482パンフレット: 2060 XRF Process Analyzer
液体プロセスコントロールのための、信頼性の高いオンライン蛍光X線分析装置。2060 XRF Process Analyzer のご紹介です。
その他の言語
- 8.000.54838.000.5483データシート: MIRA P 技術データ
MIRA P は、現場での原材料の即時識別と検証 (RMID) に優れています。トラックヤードにおける材料検査など、従来とは異なるテストシナリオでラボ品質の結果が必要な場合、MIRA P がそのソリューションです!メリット、動作仕様、サンプリングの付属品に関してまとめたこの概要が MIRA P をよりよく知るためのお手伝いをいたします。
その他の言語
- 8.000.54848.000.5484データシート: MIRA XTR 技術データ
より安全で、シンプルに、そして小さくなったラマン。MIRA XTR は、接点で材料を迅速かつ非破壊、蛍光フリーで識別する最高のソリューションです。MIRA XTR が提供するメリット、動作仕様、付属品についての詳細をご覧ください。
その他の言語
- 8.000.54858.000.5485Metrohm の適合ラマン製品ライン
研究室からトラックヤードまで、Metrohm には、原材料検査に適合する幅広いソリューションがあります!ラマンは、スムーズな操作と連続生産を確実にするため、納入される化学薬品、有効成分、賦形剤の迅速かつ正確に現場での検証を遂行します。
その他の言語
- 8.000.54868.000.5486フライヤー: 材料識別のためのハンドヘルドラマン製品ライン
Metrohm には、ラマン材料識別ソリューションに幅広いポートフォリオがあります。豊富なライブラリでも、複雑なマトリックス中の対象分析物の微量検出、フレキシブルな蛍光緩和でも、どのようなご要望にも必要なシステムをご用意しています!
その他の言語
- 8.000.54878.000.5487フライヤー: ラボラトリーラマン製品ライン
Metrohm のラマンシステムは、ラマン顕微鏡、ECラマン、グラスファイバー付属品を含む、幅広いスペクトル範囲、高い分解能、多様なサンプリング能力における柔軟性を提供します。学校のラボから研究室まで様々なラマンソリューションを取り揃えています。
その他の言語
- 8.000.54888.000.5488フライヤー: XRF による効率的な浴槽品質管理 – プロセス管理のための亜鉛ニッケルのオンライン分析
Metrohm Process Analytics 製 2060 XRF Process Analyzer で亜鉛ニッケル合金の妥協のない品質保証を実現。
その他の言語
- 8.000.54898.000.5489フライヤー: XRF による効率的なリチウムイオンバッテリー生産 – 正極活物質 (CAM) 中の金属のオンライン分析
Metrohm Process Analytics 製 2060 XRF Process Analyzer による比類のない CAM 品質管理の体験。整合性の確保のために設計されたこのアナライザーは、 CAM スラリー中の様々な要素配列を同時にモニタリングするために、迅速かつ非破壊の XRF 技術を採用しています。
その他の言語
- 8.000.54908.000.5490パンフレット: 2060 VA Process Analyzer – オンラインプロセスコントロールのための信頼性の高い微量金属分析
微量金属分析のための 2060 VA Process Analyzer のニーズに特化したメリットと特長をご覧ください。
その他の言語
- 8.000.54918.000.5491パンフレット: 2060 CVS Process Analyzer – オンラインプロセスコントロールのための信頼性の高い有機添加剤分析
PCB および半導体産業のための 2060 CVS Process Analyzer の、ニーズに特化したメリットと特長をご覧ください
その他の言語
- 8.000.54928.000.5492パンフレット: 人々の生活の向上
これは主に、当社のソーシャルフットプリントと社会に及ぼす影響に関する情報を提供する PR パンフレットです。
その他の言語
- 8.000.54938.000.5493パンフレット: OMNIS Client/Server のためのエンタープライズ・サービス
Metrohm は、OMNIS Client / Server インストールのライフサイクル全体にわたって IT サービスを提供しています。お客様のグローバル展開プロジェクトを密接にサポートするため、プロフェッショナルなサービスを提供します。また、展開プロジェクトを成功させるためのすべてのフェーズに対応するサービスを提供しています。たとえば、IT インフラの計画、安全な稼働と教育のためのコンセプト作成、顧客環境でのサーバーインストールの実装、グローバルなプロジェクト管理、エンタープライズアプリケーションの統合などです。OMNIS Client / Server システムの稼働中は、お客様に OMNIS サービスの高可用性を確保するため、 Gxp/GMP に準拠したサービスを提供することができます。
その他の言語
- 8.000.54968.000.5496パンフレット: ICP-MS MassHunter ソフトウェア用 IC ドライバー - 微量元素種分化分析のための完全統合ソリューション
Agilent の ICP-MS MassHunter ソフトウェア用 Metrohm IC Driver は、 Agilent Technologie の ICP-MS 装置と Metrohm のイオンクロマトグラフィーをシームレスに統合します。業界をリードする 2 つのブランドの優れた技術を組み合わせ、クロム、ヒ素、セレン、水銀などの微量元素の分析と種分化にプレミアムソリューションを提供します。
その他の言語
- 8.000.54978.000.5497フライヤー: 学習用 i-Raman® Plus
i-Raman Plus は、学生や研究所に理想的なラマンシステムです。軽量かつ耐久性に優れたデザインで初回セットアップを素早く行うことができ、使いやすいため、i-Raman plus は学生に最適です。
その他の言語
- 8.000.54988.000.5498パンフレット: Metrohm TacticID-1064 ST: 精度と速度で現場での化学薬品の識別を革新
クリティカルな瞬間に素早く正確な回答を提供するツールがあれば、安心感と状況制御を得ることができます。TacticID-1064 ST は 1064 nm 励起のパワー、エルゴノミクスデザイン、包括的なラマンライブラリ、オンボーディングガイド、画期的な「シースルー」分析を活用することでユーザーに効率的かつ正確な材料識別を保証します。TacticID-1064 ST は最も重要な時に正確な結果を提供します。
その他の言語
- 8.000.55008.000.5500パンフレット: OMNIS NIR オートメーション
OMNIS NIRS オートメーションのソリューションがどのようにラボの効率を向上させるかをご覧ください。このパンフレットは、液体サンプルと固形物サンプル双方にハイスループット分析を提供する NIR 分光法および OMNIS Sample Robot NIR のパワフルな組み合わせをご紹介します。拡張性と柔軟性に優れたこれらのソリューションは、OMNIS 滴定とも統合可能で、ラボのワークフローを最適化します。
その他の言語
- 8.000.55018.000.5501Metrohm TacticID-1064 ST 技術データ
The TacticID-1064 ST は、数千種類に及ぶ違法化学物質や有害化学薬品を現場で識別するための貴重なツールです。
その他の言語
- 8.000.55028.000.5502フライヤー: TacticID-1064 ST による効率的な材料識別
拡張使用時でも快適かつ効率的です。Metrohm TacticID-1064 ST のデザインは、機動力を維持し、準備万端の状態を保って、最大限の効果を発揮しながら負担を軽減します。
その他の言語
- 8.000.55038.000.5503フライヤー: Metrohm TacticID-1064 ST による包括的な検出機能
TacticID-1064 ST は、多様性と精度が求められる業務に従事する専門家にとって不可欠なツールです。1064 nm 励起のパワー、エルゴノミクスデザイン、包括的なラマンライブラリ、オンボーディングガイド、画期的な「シースルー」分析により、ユーザーは様々な場所で多種多様なサンプルを効率的かつ正確にスキャンできます。
その他の言語
- 8.000.55048.000.5504フライヤー: TacticID-1064 ST で重要な時に正確な結果を
危機的な状況では、迅速かつ信頼できるデータがあなたの判断をサポートします。TacticID-1064 ST は、一瞬一瞬が重要であり、何も運任せにはならないという安心感を提供します。
その他の言語
- 8.000.55058.000.5505パンフレット: プロセス分析のための OEM pH センサー
このパンフレットでは、プロセス分析のための Metroglas 製 OEM pH センサーのポートフォリオの概要をご覧いただけます。
その他の言語
- 8.000.55068.000.5506パンフレット: 安全性のための 2060 RISE – 資産を保護するラマンセンサー
このパンフレットでは、最新の産業プラントでの安全性と効率を向上させるために設計されたラマンインテリジェントセンサーとしての 2060 RISE に焦点を当てています。リスクを最小限に抑え、コストを削減し、化学薬品の荷下ろしプロセスを効率化するため、リアルタイムのモニタリング、プロアクティブな検出、適応性が強調されています。
その他の言語
- 8.000.55078.000.5507パンフレット: リアルタイムモニタリングのための 2060 RISE – プロセスと資産を常時監視するためのラマンセンサー
プロセスと資産の常時監視で 2060 RISE がプロセス分析に起こす革新をご覧ください。このパンフレットでは、反応モニタリング、原料識別 (RMID)、品質管理 (QC)など、2060 RISEの適用例を紹介し、その効率向上、コンプライアンスの確保、製品の完全性維持における能力に焦点を当てています。
その他の言語
- 8.000.55088.000.5508パンフレット: 2060 Raman Intelligent SEnsor «RISE» – 洞察を解き明かし、精度を高める
最先端のラマン分光技術で 2060 RISE がプロセス分析に起こす革新をご覧ください。このインテリジェントなラマンセンサーはリアルタイムの非侵襲的測定を行い、液体、気体、スラリーの正確な化学分析を実現します。多様な用途向けに設計された 2060 RISE は、バイオテクノロジー製造や燃料品質のモニタリングから食品コンプライアンス、化学薬品の取り扱いまで様々な産業にシームレスに統合されます。
その他の言語
- 8.000.55098.000.5509Metrohm Autolab 装置仕様シート
この文書では、すべての Autolab 装置の仕様をひとつのテーブルで紹介し、読者が Autolab ポートフォリオの各装置の仕様を簡単に比較できるようにしています。
その他の言語
- 8.000.55108.000.5510フライヤー: SPELEC と SPELEC1050
装置 SPELEC と SPELEC1050 のすべての技術データと重要なセールスポイントが記載されたフライヤー。
その他の言語
- 8.000.55118.000.5511フライヤー: SPELECNIR
装置 SPELECNIR のすべての技術データと重要なセールスポイントが記載されたフライヤー。
その他の言語
- 8.000.55128.000.5512フライヤー: SPELECRAMAN、SPELECRAMAN638、SPELECRAMAN532
装置 SPELECRAMAN、SPELECRAMAN638、SPELECRAMAN532 のすべての技術データと重要なセールスポイントが記載されたフライヤー。
その他の言語
- 8.000.55138.000.5513カタログ: SPELEC 製品ラインのポートフォリオ
このカタログでは、SPELEC 装置のすべての技術データ、分光化学系の付属品、DropView SPELEC ソフトウェアの主なメリットについての短い説明をご覧いただけます。
その他の言語
- 8.000.55148.000.5514フライヤー: NIR およびラマン分光法によるポリマー分析
ポリマーのメーカーは、コンプライアンスを確保し、生産プロセスを最適化し、顧客の仕様を満たすため、材料の精密分析に依存しています。これらの目標を実現するためには、ポリマー組成のリアルタイムの知識が不可欠です。分光技術、特に近赤外線 (NIR) 分光法とラマン分光法は、迅速、精密で非破壊かつ柔軟な試験ソリューションを提供します。これらのメソッドは様々なポリマーの識別と定量化を可能にし、品質管理と研究のどちらも促進します。このフライヤーでは、Metrohm 装置を使用した分光法によって分析できるいくつかの主要な品質パラメータの概要を紹介しています。
その他の言語
- 8.000.55168.000.5516パンフレット: Metrohm 認証サービス
メリット信頼できるエキスパート: 当社の認定エンジニアが IQ/OQ 手順および規制標準への適合を確実にします。; データ完全性の保証: 1 日目から追跡可能なデジタル文書。; 監査対応文書:スムーズに監査を進め、迅速にレビューを実行するために記録を適切に整理。; ダウンタイム: 迅速かつエラーのない実行を保証する自動テスト。; リモート検証: リクエストに応じて自動ソフトウェア検証をリモートで実行できます。; ご要望に応じたサービス: 購入前には専門家によるコンサルテーション、またシステムのライフサイクル全体にわたって継続的サポートを提供します。;
その他の言語
- 8.000.55178.000.5517パンフレット: OMNIS NIR Pharma
当パンフレットでは、スイスメイド OMNIS NIR Analyzer の医薬品市場におけるベネフィットをご紹介しています。パンフレットでは、アプリケーション、適合規則、オートメーション、クライアント/サーバーに関するトピックを扱っています。
その他の言語
- 8.000.55188.000.5518パンフレット: OMNIS NIR Analyzer 用プリキャリブレーション
OMNIS プリキャリブレーションは、ターンキー方式で即時使用が可能なソリューションであり、近赤外 (NIR) 分光法を使用した迅速かつ信頼性の高い品質管理を可能にします。このパンフレットでは、食品、飼料、および非食品の幅広い範囲のアプリケーションに対応する、OMNIS NIR Analyzer 向けに現在利用可能なすべてのプリキャリブレーションの概要を紹介しています。
その他の言語
- 8.000.55198.000.5519パンフレット: バイオテクノロジー産業 – バイオプロセスのモニタリングとコントロールのための包括的分析装置
バイオ医薬品製造者は、一貫性を確保し、製造を最適化し、かつ規制基準を満たすために、バイオプロセスの正確なモニタリングに依存しています。これらの目標を達成するには、重要なプロセスパラメータのリアルタイムインサイトが不可欠です。プロセスラマン分光法、pH センサー、溶存酸素や CO₂ センサーを含む Metrohm の高度な分析ソリューションは、バイオテクノロジープロセスに迅速かつ高精度で非破壊的なモニタリングを提供します。これらのツールは、既存のシステムへのシームレスな統合が可能であり、バイオプロセスの主要変数の正確なコントロールを確実に行います。このパンフレットでは、Metrohm の装置を使用してモニタリングできる、重要なバイオプロセスパラメータの概要について説明しています。
その他の言語
- 8.000.55208.000.5520パンフレット: Metrohm Lab Robotics
このパンフレットでは、Metrohm Lab Robotics ソリューションについてご紹介しています。一般的なラボラトリーオートメーションの理由に加え、すでに実行済みプロジェクトの簡単なプレゼンテーションを含む、カスタマイズされたロボットシステム向けの当社のプロジェクトアプローチの概要をご覧いただけます。
その他の言語
- 8.000.55218.000.5521パンフレット: i-Raman NxG- 次世代の品質管理を実現
品質管理測定のコントロールが必要ですか?i-Raman NxG を一次メソッドに統合することで、より迅速かつシンプルなルーチン測定を可能にし、より短時間でより多くのサンプルを測定できるようにすることでラボの能力を向上させる方法をご覧ください。
その他の言語
- 8.000.55228.000.5522パンフレット: Metrohm Autolab ポートフォリオの概要
Metrohm Autolab ポートフォリオのパンフレット: VIONIC およびすべての NOVA 対応装置、EC ラマン、UV-VIS、SECM のハイフネーションや付属品を含む Metrohm Autolab の全製品ポートフォリオを網羅した総合パンフレットです。
その他の言語
- 8.000.55238.000.5523フライヤー: 石油化学
原油は、炭化水素とその他の化合物から構成される非常に複雑な混合物であり、脱塩、蒸留、脱硫、転化によって液化ガスやガソリン、ディーゼル、暖房用燃料、潤滑剤などの高品質の炭化水素や、その他の多様な製品に変換されます。精製プロセスへの要求は厳しく、正確かつ信頼性の高い分析が必要となります。このパンフレットでは、滴定、イオンクロマトグラフィー、ボルタンメトリー、CVS、または NIRS やラマン分光法などのメソッドによる分析技術をラボや生産プロセスに統合させるためのさまざまな関連パラメータの概要を紹介しています。この概要は、様々な生産手順と最終生成製品に従って構成されています。
その他の言語
- 8.000.55248.000.5524パンフレット: 2026 年の製品のハイライト
本パンフレットでは、Metrohm の 2026 年の製品ポートフォリオから、ハイライトの概要をご紹介しています。
その他の言語
- 8.000.55258.000.5525フライヤー: SpecSuite ソフトウェア
SpecSuite は、i-Raman 実験室用装置向けのオールインワンのソフトウェアプラットフォームです。探索的研究から高スループットのルーチン分析のいずれも想定して設計されており、直感的な操作性と堅牢な機能を提供し、アプリケーションや経験レベルを問わず、ストリーミングデータ収集を効率化します。SpecSuite はラマン分光法の可能性を再定義します。
その他の言語
- 8.000.55268.000.5526フライヤー: i-Raman Duo でフルスペクトルの明瞭性を実現
より多くスペクトルの情報を得ることは、アプリケーション範囲がより広がることを意味します。i-Raman Duo が連結ラマン技術を用いて、1 回の走査で指紋領域から伸縮領域までをカバーし、ラマンスペクトルを提供する仕組みをご覧ください。
その他の言語
- 8.000.55278.000.5527フライヤー: i-Raman NxG で QC 効率を最大限に
i-Raman NxG による迅速かつ容易なルーチン分析が品質管理ラボの効率を最大限に向上させる方法をご覧ください。
その他の言語
- 8.000.55288.000.5528フライヤー: i-Raman NxG で QC サンプリングを包括的に
品質管理ラボでは、日常的な測定に信頼性が高く一貫性のあるサンプリングが求められます。i-Raman NxG のファイバープローブは、最高のサンプリング柔軟性を提供するように設計されています。幅広い専用付属品と連携するため、日常的な QC サンプルを迅速かつ確実にテストすることができます。
その他の言語
- 8.000.55298.000.5529フライヤー: ProTrode 400 センサー – 化学工業のインライン pH 測定向け電極
このフライヤーでは、過酷な産業環境におけるインライン pH 測定向けの堅牢なメンテナンスフリーの電極として ProTrode 400 センサーをご紹介します。本製品のオープンジャンクションダイヤフラム、幅広い pH 値範囲、統合された温度センサーが、スラリーや廃水のような固形分の高い溶媒中でも、正確なリアルタイムのモニタリングを保証します。
その他の言語
- 8.000.55308.000.5530フライヤー: ProTrode pCO2 センサー – インライン溶存二酸化炭素 (pCO2) センサー
このフライヤーでは、医薬品やバイオテクノロジーの製造プロセスにおけるインライン溶存二酸化炭素測定に信頼性の高いソリューションとして、ProTrode pCO₂ センサーを紹介しています。耐腐食性のチタンキャップ、衛生的な設計、CIP や SIP、およびオートクレーブとの互換性により、正確なリアルタイムモニタリングと長寿命を実現します。
その他の言語
- 8.000.55318.000.5531フライヤー: ProTrode DO センサー – インライン溶存酸素 (DO) センサー
このフライヤーでは、バイオテクノロジーのプロセスにおけるインライン溶存酸素測定のための光学ソリューションとして、ProTrode 溶存酸素 (DO) センサーを紹介しています。
その他の言語
- 8.000.55328.000.5532パンフレット: OMNIS NIR を使ったよりスマートな分析
NIR 分光法は、食品製造の全工程において信頼性、一貫性、品質を保証します。あらゆる食品分析に必要な優れた性能を提供する、OMNIS NIR Analyzer による新世代の NIR Analyzer についての詳細をご覧ください。
その他の言語
- 8.000.55338.000.5533フライヤー: i-Raman NxG 製品ラインガイド
このフライヤーでは、ご購入いただける様々な i-Raman NxG モデルとそれぞれの仕様についてご紹介しています。ソフトウェア情報とオプション付属品のリストも含まれています。
その他の言語
- 8.000.55348.000.5534フライヤー: i-Raman Plus - 研究や教育用のラボ向けラマンソリューション
i-Raman Plus 製品ラインガイドでは、本ポートフォリオの各ラマン装置の基本的な技術データに加え、ソフトウェアの詳細および利用可能な付属品のリストをご覧いただけます。
その他の言語
- 8.000.55368.000.5536パンフレット: OMNIS NIR Analyzer
正確で迅速かつ規定に準拠した測定のためのモジュール式 NIR 分析プラットフォームです。
その他の言語
- 8.000.55378.000.5537パンフレット: 2060 TI Ex Proof Process Analyzer
濃度の高い可燃性ガス、蒸気、または粉塵が生じる、爆発の危険がある環境においては、測定装置を安全に操作することができ、かつ爆発を引き起こさないことが不可欠です。当パンフレットでは、2060 Ti Ex proof Process analyzer をご紹介します。
その他の言語
- 8.000.55418.000.5541フライヤー: 再生可能燃料
バイオディーゼルやバイオエタノールなど、有機物を原料とする再生可能燃料の製造は要件が厳しく、正確かつ信頼性の高い分析が要求されます。このフライヤーでは、滴定、イオンクロマトグラフィー、または NIR 分光法などのメソッドによる分析技術をラボや生産プロセスに統合させるための様々な関連パラメータの概要を紹介しています。この概要は、再生可能燃料の様々なタイプに従って構成されています。
その他の言語
- 8.0010.50018.0010.5001低圧グラジェントシステムの設置ガイド
低圧グラジェントシステムは、時間制御バルブシフトによるグラジェントを使用した、サプレッションを伴う、陰イオンまたは陽イオンの全自動測定のための Professional IC システムです。低圧グラジェントを使用して、異なる溶離液を 3 つまで混合できます。イオンクロマトグラフィーのあらゆるルーチンタスクを安全に処理し、使いやすく、フレキシブルで信頼性の高い装置です。この Application Bulletin では、低圧グラジェントシステムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50028.0010.5002ドーズイングラジェントシステムの設置ガイド
ドーズイングラジェントは、サプレッションを伴う陰イオンまたは陽イオンの全自動測定に、Compact IC および Professional IC システムと併せて使用できます。ドーズイングラジェントのセットアップは非常に柔軟であり、 IC システムに対し、1 つの溶離液に 5 つまで異なる溶液を組み合わせることができます。グラジェントプロファイルは、一定流量で作動する 1 台の高圧ポンプと、メインの溶離液の流れに混合される追加溶液を供給する、1 台以上の Dosino によって生成されます。最終的に溶離液濃度を測定する Dosino から供給される溶液の量は、MagIC Net で簡単にプログラムできます。使いやすく、柔軟性があり、非常に信頼性の高い装置です。この Application Bulletin では、ドーズイングラジェントシステムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50038.0010.5003ProfIC Vario 1 Anion の設置ガイド
ProfIC Vario 1 Anion は、連続サプレッションを伴う陰イオンまたは陽イオンの全自動測定のための Professional IC Vario システムです。«ProfIC Vario 1» は、イオンクロマトグラフィーのあらゆるルーチンタスクを安全に処理します。使いやすく、フレキシブルで信頼性の高い装置です。この Application Bulletin では、陰イオンまたは陽イオン同定のための連続サプレッションを伴う Professional IC Vario システムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50048.0010.5004ProfIC Vario 1 Cation の設置ガイド
ProfIC Vario 1 Cation は、ノンサプレッサー型陽イオンおよび陰イオンの全自動測定のための Professional IC Vario システムです。«ProfIC Vario 1» は、イオンクロマトグラフィーのあらゆるルーチンタスクを安全に処理します。使いやすく、フレキシブルで信頼性の高い装置です。この Application Bulletin では、ノンサプレッサー型 IC システムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50058.0010.5005ProfIC Vario 1 AnCat の設置ガイド
ProfIC Vario 1 AnCat は、連続サプレッションを伴う陰イオン、および陽イオンの全自動測定のための非常にコンパクトかつプロフェッショナルな IC システムです。«ProfIC Vario 1 AnCat» では、時間を節約するため、陰イオンと陽イオンを並行および個別どちらでも測定でできます。どちらのシステムでも、ポンプを搭載した同 858 Professional Sample Processor が使用され、MagIC Net ソフトウェアで制御されます。この Application Bulletin では、、ProfIC Vario 1 AnCat システムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50068.0010.5006ProfIC Vario 1 UV/VIS の設置ガイド
ProfIC Vario 1 UV/VIS は、UV/VIS 活性化合物の全自動測定のための Professional IC システムです。«ProfIC Vario 1» は、イオンクロマトグラフィーのあらゆるルーチンタスクを安全に処理します。使いやすく、フレキシブルで信頼性の高い装置です。この Application Bulletin では、ProfIC Vario 1 UV/VIS システムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50078.0010.5007ProfIC Vario 1 PCR-UV/VIS の設置ガイド
ProfIC Vario 1 PCR-UV/VIS は、ポストカラム反応 (PCR) 後の UV/VIS 活性化合物の全自動測定のための Professional IC システムです。«ProfIC Vario 1» は、イオンクロマトグラフィーのあらゆるルーチンタスクを安全に処理します。使いやすく、フレキシブルで信頼性の高い装置です。この Application Bulletin では、PCR 付き ProfIC Vario 1 UV/VIS システムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50088.0010.5008ProfIC Vario 1 Amperometry の設置ガイド
ProfIC Vario 1 Amperometry は、アンペロメトリック検出による電気活性化合物の全自動測定のための Professional IC システムです。«ProfIC Vario 1» は、イオンクロマトグラフィーのあらゆるルーチンタスクを安全に処理します。使いやすく、フレキシブルで信頼性の高い装置です。この Application Bulletin では、アンペロメトリック検出器付き ProfIC Vario 1 システムの推奨装置と取り付け、ならびに MagIC Net でのメソッドのインポートや取り扱いについて説明しています。
その他の言語
- 8.0010.50098.0010.5009ProfIC Vario 6 Anion の設置ガイド
ProfIC Vario 6 Anion は、粒子を含むマトリックス中の、非常に濃度が高い連続サプレッション型陰イオンまたは陽イオンの全自動測定のための、インライン希釈とインライン限外ろ過を装備した Professional IC Vario システムです。ユーザーは、このシステムを用いて、分析前に、サンプルを希釈し、、バクテリアや無機粒子を除去することができます。インライン希釈とインライン限外ろ過の組み合わせにより、ラボのスループット速度を上げ、データ信頼性と精度を向上させるとともに手動によるミスを低減し、最小限に抑えることができます。この Application Bulletin では、インライン希釈とインライン限外ろ過を組み合わせた MISP 技術による、陰イオン測定に対応した ProfIC Vario 6 Anion システムの推奨装置と取り付けについて説明しています。メソッドのインポートと修正についても文書内で説明しています。
その他の言語