Professional VA 装置用の抗酸化物質測定のための Glassy Carbon 回転円盤電極付き VA 電極装備

Professional VA 装置用の抗酸化物質測定のための Glassy Carbon 回転円盤電極付き VA 電極装備

6.5339.100

    • 分離Ptロッド電極
    • 6.0343.100
    • 電圧電流法およびCVSのための白銀AE。
    • <p>電圧電流法およびCVSのための白銀AE。</p>
    • PCS
    • 2
    • Driving axle for rotating disk electrode (RDE)
    • 6.1204.510
    • Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
    • <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
    • PCS
    • 1
    • Glassy carbon electrode tip, shaft made of glass.  
    • 6.1204.600
    • Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C. 
    • <p>Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: &lt;0.25 mm. Temperature range: 0 - 50°C. </p>
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • 分離Ptロッド電極
    • 6.0343.100
    • 電圧電流法およびCVSのための白銀AE。
    • <p>電圧電流法およびCVSのための白銀AE。</p>
    • PCS
    • 2
    • Driving axle for rotating disk electrode (RDE)
    • 6.1204.510
    • Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
    • <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
    • PCS
    • 1
    • Glassy carbon electrode tip, shaft made of glass.  
    • 6.1204.600
    • Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C. 
    • <p>Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: &lt;0.25 mm. Temperature range: 0 - 50°C. </p>
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1