VA electrode equipment with rotating glassy carbon disc electrode (RDE) for antioxidant determination for Professional VA instruments
6.5339.100
-
- Separate Pt Rod Electrode
- 6.0343.100
- Platinum auxiliary electrode for voltammetry and CVS.
- <p>Platinum auxiliary electrode for voltammetry and CVS.</p>
- PCS
- 2
- Driving axle for rotating disk electrode (RDE)
- 6.1204.510
- Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
- <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
- PCS
- 1
- Glassy carbon electrode tip, shaft made of glass.
- 6.1204.600
- Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C.
- <p>Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C. </p>
- PCS
- 1
- Titration vessel / 5-70 mL
- 6.1415.150
- PCS
- 1
- Polishing set for solid-state electrodes
- 6.2802.000
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- PCS
- 1
-
- Separate Pt Rod Electrode
- 6.0343.100
- Platinum auxiliary electrode for voltammetry and CVS.
- <p>Platinum auxiliary electrode for voltammetry and CVS.</p>
- PCS
- 2
- Driving axle for rotating disk electrode (RDE)
- 6.1204.510
- Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
- <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
- PCS
- 1
- Glassy carbon electrode tip, shaft made of glass.
- 6.1204.600
- Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C.
- <p>Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C. </p>
- PCS
- 1
- Titration vessel / 5-70 mL
- 6.1415.150
- PCS
- 1
- Polishing set for solid-state electrodes
- 6.2802.000
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
- PCS