元の言語のページへ戻りました
Metrohm Hyphenated EC-Raman Starter Electrocatalysis Solution

Metrohm Hyphenated EC-Raman Starter Electrocatalysis Solution

EC.Raman.ECAT.Starter

Metrohm Hyphenated EC-Raman Starter Electrocatalysis Solution

ja

EC.Raman.ECAT.Starter

特長

Includes a compact Autolab PGSTAT204 with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Discover simultaneous structural and functional information about your catalysts quickly without complicated setups or worries about synchronizing measurements. This is all possible with the EC-Raman Starter Solution.• An electrochemical workstation with high accuracy EIS.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• Measurements are automatically synchronized.• 532 nm laser excitation for higher Raman signal.

    • Autolab PGSTAT204
    • AUT204.S
    • The PGSTAT204 combines the small footprint with a modular design. The instrument includes a base potentiostat/galvanostat with a compliance voltage of 20 V and a maximum current of 400 mA or 10 A in combination with the BOOSTER10A. The potentiostat can be expanded at any time with one additional module, for example the FRA32M electrochemical impedance spectroscopy (EIS) module.The PGSTAT204 is an affordable instrument which can be located anywhere in the lab. Analog and digital inputs/outputs are available to control Autolab accessories and external devices are available. The PGSTAT204 includes a built-in analog integrator. In combination with the powerful NOVA software it can be used for most of the standard electrochemical techniques.
    • PCS
    • 1
    •  Electrochemical impedance spectroscopy module
    • FRA32M.S
    • The FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.
    • PCS
    • 1
    • ビデオマイクロスコープ付きラマンサンプル採取システム (532 nm)
    • BWT-840000962
    • ラボおよび産業用のB&W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。532 nmコンフィグレーション。BAC151C-532 
    • <p>ラボおよび産業用のB&amp;W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。532 nmコンフィグレーション。</p><p>BAC151C-532<br /> </p>
    • PCS
    • 1
    • Autolab PGSTAT204
    • AUT204.S
    • The PGSTAT204 combines the small footprint with a modular design. The instrument includes a base potentiostat/galvanostat with a compliance voltage of 20 V and a maximum current of 400 mA or 10 A in combination with the BOOSTER10A. The potentiostat can be expanded at any time with one additional module, for example the FRA32M electrochemical impedance spectroscopy (EIS) module.The PGSTAT204 is an affordable instrument which can be located anywhere in the lab. Analog and digital inputs/outputs are available to control Autolab accessories and external devices are available. The PGSTAT204 includes a built-in analog integrator. In combination with the powerful NOVA software it can be used for most of the standard electrochemical techniques.
    • PCS
    • 1
    •  Electrochemical impedance spectroscopy module
    • FRA32M.S
    • The FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.
    • PCS
    • 1
    • ビデオマイクロスコープ付きラマンサンプル採取システム (532 nm)
    • BWT-840000962
    • ラボおよび産業用のB&W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。532 nmコンフィグレーション。BAC151C-532 
    • <p>ラボおよび産業用のB&amp;W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。532 nmコンフィグレーション。</p><p>BAC151C-532<br /> </p>
    • PCS
    • 1
    • ビデオマイクロスコープ対物レンズ、50倍拡大
    • BWT-840000325
    • マイクロスコープ対物レンズ、無限補正、50倍拡大、作業距離 (mm) = 9.15、焦点距離 (mm) = 4、開口数 (NA) = 0.55。RML150A 
    • <p>マイクロスコープ対物レンズ、無限補正、50倍拡大、作業距離 (mm) &#61; 9.15、焦点距離 (mm) &#61; 4、開口数 (NA) &#61; 0.55。</p><p>RML150A<br /> </p>
    • PCS
    • 1