Foi redireccionado para a sua versão local da página solicitada.
Metrohm Hyphenated EC-Raman Starter Electrocatalysis Solution

Metrohm Hyphenated EC-Raman Starter Electrocatalysis Solution

EC.Raman.ECAT.Starter

Metrohm Hyphenated EC-Raman Starter Electrocatalysis Solution

en

EC.Raman.ECAT.Starter

Visão geral

Includes a compact Autolab PGSTAT204 with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.

Discover simultaneous structural and functional information about your catalysts quickly without complicated setups or worries about synchronizing measurements. This is all possible with the EC-Raman Starter Solution.


• An electrochemical workstation with high accuracy EIS.
• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.
• Measurements are automatically synchronized.
• 532 nm laser excitation for higher Raman signal.

    • Autolab PGSTAT204
    • AUT204.S
    • The PGSTAT204 combines the small footprint with a modular design. The instrument includes a base potentiostat/galvanostat with a compliance voltage of 20 V and a maximum current of 400 mA or 10 A in combination with the BOOSTER10A. The potentiostat can be expanded at any time with one additional module, for example the FRA32M electrochemical impedance spectroscopy (EIS) module.The PGSTAT204 is an affordable instrument which can be located anywhere in the lab. Analog and digital inputs/outputs are available to control Autolab accessories and external devices are available. The PGSTAT204 includes a built-in analog integrator. In combination with the powerful NOVA software it can be used for most of the standard electrochemical techniques.
    • <p>The PGSTAT204 combines the small footprint with a modular design. The instrument includes a base potentiostat/galvanostat with a compliance voltage of 20 V and a maximum current of 400 mA or 10 A in combination with the BOOSTER10A. The potentiostat can be expanded at any time with one additional module, for example the FRA32M electrochemical impedance spectroscopy (EIS) module.</p><p>The PGSTAT204 is an affordable instrument which can be located anywhere in the lab. Analog and digital inputs/outputs are available to control Autolab accessories and external devices are available. The PGSTAT204 includes a built-in analog integrator. In combination with the powerful NOVA software it can be used for most of the standard electrochemical techniques.</p>
    • PCS
    • 1
    •  Electrochemical impedance spectroscopy module
    • FRA32M.S
    • The FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.
    • <p>The FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.</p><p>The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.</p>
    • PCS
    • 1
    • Raman Video Micro-Sampling System (532 nm)
    • BWT-840000962
    • Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective with a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 532 nm configuration.BAC151C-532 
    • <p>Video microscope sampling system for use with B&amp;W Tek&#039;s lab and industrial Raman probes. Includes a 20x objective with a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 532 nm configuration.</p><p>BAC151C-532<br /> </p>
    • PCS
    • 1
    • Trigger cable for PGSTAT204 Hyphenated EC-Raman Solutions 
    • 3500003130
    • This trigger cable connects the Autolab PGSTAT204 to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.
    • <p>This trigger cable connects the Autolab PGSTAT204 to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.</p>
    • PCS
    • 1
    • Autolab PGSTAT204
    • AUT204.S
    • The PGSTAT204 combines the small footprint with a modular design. The instrument includes a base potentiostat/galvanostat with a compliance voltage of 20 V and a maximum current of 400 mA or 10 A in combination with the BOOSTER10A. The potentiostat can be expanded at any time with one additional module, for example the FRA32M electrochemical impedance spectroscopy (EIS) module.The PGSTAT204 is an affordable instrument which can be located anywhere in the lab. Analog and digital inputs/outputs are available to control Autolab accessories and external devices are available. The PGSTAT204 includes a built-in analog integrator. In combination with the powerful NOVA software it can be used for most of the standard electrochemical techniques.
    • <p>The PGSTAT204 combines the small footprint with a modular design. The instrument includes a base potentiostat/galvanostat with a compliance voltage of 20 V and a maximum current of 400 mA or 10 A in combination with the BOOSTER10A. The potentiostat can be expanded at any time with one additional module, for example the FRA32M electrochemical impedance spectroscopy (EIS) module.</p><p>The PGSTAT204 is an affordable instrument which can be located anywhere in the lab. Analog and digital inputs/outputs are available to control Autolab accessories and external devices are available. The PGSTAT204 includes a built-in analog integrator. In combination with the powerful NOVA software it can be used for most of the standard electrochemical techniques.</p>
    • PCS
    • 1
    •  Electrochemical impedance spectroscopy module
    • FRA32M.S
    • The FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.
    • <p>The FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.</p><p>The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.</p>
    • PCS
    • 1
    • Raman Video Micro-Sampling System (532 nm)
    • BWT-840000962
    • Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective with a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 532 nm configuration.BAC151C-532 
    • <p>Video microscope sampling system for use with B&amp;W Tek&#039;s lab and industrial Raman probes. Includes a 20x objective with a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 532 nm configuration.</p><p>BAC151C-532<br /> </p>
    • PCS
    • 1
    • Trigger cable for PGSTAT204 Hyphenated EC-Raman Solutions 
    • 3500003130
    • This trigger cable connects the Autolab PGSTAT204 to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.
    • <p>This trigger cable connects the Autolab PGSTAT204 to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.</p>
    • PCS
    • 1
    • Video Microscope Objective, 50x (RML150A)
    • BWT-840000325
    • Microscope objective, infinity-corrected, 50x, working distance (mm) = 9.15, focal length (mm) = 4, numerical aperture (NA) = 0.55.RML150A 
    • <p>Microscope objective, infinity-corrected, 50x, working distance (mm) &#61; 9.15, focal length (mm) &#61; 4, numerical aperture (NA) &#61; 0.55.</p><p>RML150A<br /> </p>
    • PCS
    • 1