元の言語のページへ戻りました
VA electrode equipment with rotating disc electrode (RDE) made of glassy carbon for Professional VA instruments

VA electrode equipment with rotating disc electrode (RDE) made of glassy carbon for Professional VA instruments

6.5339.040

    • Ag/AgCl参照電極
    • 6.0728.120
    • c(KCl) = 3 mol/Lの内部液付き内部参照システム。プラスチック製内部液容器 6.1245.010 を伴う使用のため。
    • <p>c(KCl) = 3 mol/Lの内部液付き内部参照システム。プラスチック製内部液容器 6.1245.010 を伴う使用のため。</p>
    • PCS
    • 1
    • Driving axle for rotating disk electrode (RDE)
    • 6.1204.510
    • Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
    • <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
    • PCS
    • 1
    • Glassy carbon electrode tip, shaft made of glass.  
    • 6.1204.600
    • Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C. 
    • <p>Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: &lt;0.25 mm. Temperature range: 0 - 50°C. </p>
    • PCS
    • 1
    • 電極ホルダ
    • 6.1241.120
    • VA 対極用の電極ホルダ、プラグコンタクト 5.5 mm 付き。Glassy Carbon ピン (6.1247.000) もしくは白金ピン (6.1247.010) を伴う使用向け。
    • <p>VA 対極用の電極ホルダ、プラグコンタクト 5.5 mm 付き。Glassy Carbon ピン (6.1247.000) もしくは白金ピン (6.1247.010) を伴う使用向け。</p>
    • PCS
    • 1
    • プラスチック製内部液容器
    • 6.1245.010
    • ダブルジャンクション参照電極のためのセラミックダイアフラム付きプラスチック製内部液容器。
    • <p>ダブルジャンクション参照電極のためのセラミックダイアフラム付きプラスチック製内部液容器。</p>
    • PCS
    • 1
    • GCピン
    • 6.1247.000
    • 電圧電流法AE用の電極ホルダ6.1241.020もしくは6.1241.120のため。
    • <p>電圧電流法AE用の電極ホルダ6.1241.020もしくは6.1241.120のため。</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1
    • Ag/AgCl参照電極
    • 6.0728.120
    • c(KCl) = 3 mol/Lの内部液付き内部参照システム。プラスチック製内部液容器 6.1245.010 を伴う使用のため。
    • <p>c(KCl) = 3 mol/Lの内部液付き内部参照システム。プラスチック製内部液容器 6.1245.010 を伴う使用のため。</p>
    • PCS
    • 1
    • Driving axle for rotating disk electrode (RDE)
    • 6.1204.510
    • Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
    • <p>Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.</p>
    • PCS
    • 1
    • Glassy carbon electrode tip, shaft made of glass.  
    • 6.1204.600
    • Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C. 
    • <p>Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: &lt;0.25 mm. Temperature range: 0 - 50°C. </p>
    • PCS
    • 1
    • 電極ホルダ
    • 6.1241.120
    • VA 対極用の電極ホルダ、プラグコンタクト 5.5 mm 付き。Glassy Carbon ピン (6.1247.000) もしくは白金ピン (6.1247.010) を伴う使用向け。
    • <p>VA 対極用の電極ホルダ、プラグコンタクト 5.5 mm 付き。Glassy Carbon ピン (6.1247.000) もしくは白金ピン (6.1247.010) を伴う使用向け。</p>
    • PCS
    • 1
    • プラスチック製内部液容器
    • 6.1245.010
    • ダブルジャンクション参照電極のためのセラミックダイアフラム付きプラスチック製内部液容器。
    • <p>ダブルジャンクション参照電極のためのセラミックダイアフラム付きプラスチック製内部液容器。</p>
    • PCS
    • 1
    • GCピン
    • 6.1247.000
    • 電圧電流法AE用の電極ホルダ6.1241.020もしくは6.1241.120のため。
    • <p>電圧電流法AE用の電極ホルダ6.1241.020もしくは6.1241.120のため。</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1
    • Polishing set for solid-state electrodes
    • 6.2802.000
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • Polishing set with 1 polishing cloth and about 2 g aluminum oxide powder (grain size 0.3 µm)
    • PCS
    • 1