914 pH/DO/Conductometer with accessories case
2.914.0130
-
- /shared/en/products/6/0917/60917080
- Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable)
- https://s7e5a.scene7.com/is/image/metrohm/60917080?$sq-500$&bfc=on
- 6.0917.080
- 4-wire conductivity measuring cell with cell constant c = 0.5 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant. The sensor is suitable for measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:drinking water; surface water; wastewater;
- <p>4-wire conductivity measuring cell with cell constant c = 0.5 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.<br /><br />Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant. The sensor is suitable for measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p> </p>
- PCS
- 1
- /shared/en/products/6/1116/61116000
- O2 Lumitrode
- https://s7e5a.scene7.com/is/image/metrohm/61116000_1?$sq-500$&bfc=on
- 6.1116.000
- The optical sensor for measuring dissolved oxygen (DO) can be used with a 913 pH/DO meter or with a 914 pH/DO conductometer. The measuring principle of the sensor is based on luminescence quenching. The space-saving and maintenance-free sensor is suitable for DO measurement, for example in: Water quality control; Wastewater industry; Beverage production; Fish farming; This sensor is supplied with a calibration vessel. Where necessary, it is easy to replace the measurement cap (O2 cap) that contains the oxygen-intensive luminophore.
- <p>The optical sensor for measuring dissolved oxygen (DO) can be used with a 913 pH/DO meter or with a 914 pH/DO conductometer. The measuring principle of the sensor is based on luminescence quenching. The space-saving and maintenance-free sensor is suitable for DO measurement, for example in: </p><ul><li>Water quality control</li><li>Wastewater industry</li><li>Beverage production</li><li>Fish farming</li></ul><p>This sensor is supplied with a calibration vessel. </p><p>Where necessary, it is easy to replace the measurement cap (O<sub>2</sub> cap) that contains the oxygen-intensive luminophore.</p><p> </p><p> </p><p/>
- PCS
- 1
- /shared/en/products/6/1446/61446000
- SGJ stopper / B-14/(15)
- https://s7e5a.scene7.com/is/image/metrohm/61446000?$sq-500$&bfc=on
- 6.1446.000
- PCS
- 2
- /shared/en/products/6/1613/61613010
- Bottle / 25 mL
- https://s7e5a.scene7.com/is/image/metrohm/61613010?$sq-500$&bfc=on
- 6.1613.010
- PCS
- 2
- /shared/en/products/6/1613/61613020
- Bottle / 25 mL / label pH 7 (empty)
- https://s7e5a.scene7.com/is/image/metrohm/61613010?$sq-500$&bfc=on
- 6.1613.020
- PCS
- 1
- /shared/en/products/6/1613/61613030
- Bottle / 25 mL / label pH 4 (empty)
- https://s7e5a.scene7.com/is/image/metrohm/61613010?$sq-500$&bfc=on
- 6.1613.030
- PCS
- 1
- /shared/en/products/6/1614/61614000
- Wash bottle / 250 mL
- https://s7e5a.scene7.com/is/image/metrohm/61614000?$sq-500$&bfc=on
- 6.1614.000
- PCS
- 1
- /shared/en/products/6/2008/62008060
- Holder for electrode storage vessel
- https://s7e5a.scene7.com/is/image/metrohm/62008060?$sq-500$&bfc=on
- 6.2008.060
- Practical holder for fastening the electrode storage vessels to the 912, 913 or 914 pH/Conductometers.
- <p>Practical holder for fastening the electrode storage vessels to the 912, 913 or 914 pH/Conductometers.</p>
- PCS
- 1
- /shared/en/products/6/2050/62050010
- Carrying strap for 912/913/914
- https://s7e5a.scene7.com/is/image/metrohm/62050010-2?$sq-500$&bfc=on
- 6.2050.010
- Carrying strap for 912/913/914 meters
- <p>Carrying strap for 912/913/914 meters</p>
- PCS
- 1
- /shared/en/products/6/2151/62151100
- Adapter USB MINI (OTG) - USB A
- https://s7e5a.scene7.com/is/image/metrohm/62151100_1?$sq-500$&bfc=on
- 6.2151.100
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- /shared/en/products/6/2151/62151110
- Metrohm USB Mini B cable (OTG) - USB A, 1.8 m
- https://s7e5a.scene7.com/is/image/metrohm/62151110?$sq-500$&bfc=on
- 6.2151.110
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- /shared/en/products/6/2166/62166100
- USB power supply unit 5.25 V / 1.53 A
- https://s7e5a.scene7.com/is/image/metrohm/62166100-2?$sq-500$&bfc=on
- 6.2166.100
- USB power supply unit for 912 / 913 / 914Efficiency Level VI
- <p>USB power supply unit for 912 / 913 / 914</p><p>Efficiency Level VI</p>
- PCS
- 1
- /shared/en/products/6/2308/62308050
- Electrolyte 3 mol/L KCl (50 mL)
- https://metrohm.scene7.com/is/image/metrohm/62308050?$sq-500$&bfc=on
- 6.2308.050
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- PCS
- 1
- /shared/en/products/6/2324/62324110
- Conductivity standard 100 µS/cm, 5 x 30 mL
- https://s7e5a.scene7.com/is/image/metrohm/62324110_s?$sq-500$&bfc=on
- 6.2324.110
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1
- /shared/en/products/6/2716/62716060
- Case for 912 / 913 / 914
- https://s7e5a.scene7.com/is/image/metrohm/62716060?$sq-500$&bfc=on
- 6.2716.060
- Case for the 912 / 913 / 914 pH/Conductometers.
- <p>Case for the 912 / 913 / 914 pH/Conductometers.</p>
- PCS
- 1
- /shared/en/products/6/2717/62717000
- PP beaker, 100 mL
- https://s7e5a.scene7.com/is/image/metrohm/62717000?$sq-500$&bfc=on
- 6.2717.000
- Beaker made of PP, 100 mL.
- <p>Beaker made of PP, 100 mL.</p>
- PCS
- 1
-
- /shared/en/products/1/9140/19140030
- pH/DO/Conductometer
- https://metrohm.scene7.com/is/image/metrohm/5146?$sq-500$&bfc=on
- 1.914.0030
- Portable two-channel pH/DO/conductivity measuring instrument with intelligent measuring input for the parallel measurement of pH/mV and conductivity or dissolved oxygen and conductivity in water.Parallel measurement of pH value and conductivity or of dissolved oxygen and conductivity; Analog conductivity measuring input for the 4-conductor conductivity measuring cells; Digital measuring input for the intelligent pH electrodes or the intelligent O2 Lumitrode; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination for simple readability of the results; USB interface for simple data export to the PC or the printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compatible printout and data export with User ID and timestamp;
- <p><strong>Portable two-channel pH/DO/conductivity measuring instrument with intelligent measuring input for the parallel measurement of pH/mV and conductivity or dissolved oxygen and conductivity in water.</strong></p><ul><li>Parallel measurement of pH value and conductivity or of dissolved oxygen and conductivity</li><li>Analog conductivity measuring input for the 4-conductor conductivity measuring cells</li><li>Digital measuring input for the intelligent pH electrodes or the intelligent O<sub>2</sub> Lumitrode</li><li>Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use</li><li>LCD color display with background illumination for simple readability of the results</li><li>USB interface for simple data export to the PC or the printer</li><li>Large internal memory (10,000 data sets)</li><li>Pin-protected User mode and Expert mode, prevents unwanted parameter changes</li><li>GLP-compatible printout and data export with User ID and timestamp</li></ul>
- PCS
- 1
- /shared/en/products/6/0917/60917080
- Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable)
- https://s7e5a.scene7.com/is/image/metrohm/60917080?$sq-500$&bfc=on
- 6.0917.080
- 4-wire conductivity measuring cell with cell constant c = 0.5 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant. The sensor is suitable for measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:drinking water; surface water; wastewater;
- <p>4-wire conductivity measuring cell with cell constant c = 0.5 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.<br /><br />Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant. The sensor is suitable for measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p> </p>
- PCS
- 1
- /shared/en/products/6/1116/61116000
- O2 Lumitrode
- https://s7e5a.scene7.com/is/image/metrohm/61116000_1?$sq-500$&bfc=on
- 6.1116.000
- The optical sensor for measuring dissolved oxygen (DO) can be used with a 913 pH/DO meter or with a 914 pH/DO conductometer. The measuring principle of the sensor is based on luminescence quenching. The space-saving and maintenance-free sensor is suitable for DO measurement, for example in: Water quality control; Wastewater industry; Beverage production; Fish farming; This sensor is supplied with a calibration vessel. Where necessary, it is easy to replace the measurement cap (O2 cap) that contains the oxygen-intensive luminophore.
- <p>The optical sensor for measuring dissolved oxygen (DO) can be used with a 913 pH/DO meter or with a 914 pH/DO conductometer. The measuring principle of the sensor is based on luminescence quenching. The space-saving and maintenance-free sensor is suitable for DO measurement, for example in: </p><ul><li>Water quality control</li><li>Wastewater industry</li><li>Beverage production</li><li>Fish farming</li></ul><p>This sensor is supplied with a calibration vessel. </p><p>Where necessary, it is easy to replace the measurement cap (O<sub>2</sub> cap) that contains the oxygen-intensive luminophore.</p><p> </p><p> </p><p/>
- PCS
- 1
- /shared/en/products/6/1446/61446000
- SGJ stopper / B-14/(15)
- https://s7e5a.scene7.com/is/image/metrohm/61446000?$sq-500$&bfc=on
- 6.1446.000
- PCS
- 2
- /shared/en/products/6/1613/61613010
- Bottle / 25 mL
- https://s7e5a.scene7.com/is/image/metrohm/61613010?$sq-500$&bfc=on
- 6.1613.010
- PCS
- 2
- /shared/en/products/6/1613/61613020
- Bottle / 25 mL / label pH 7 (empty)
- https://s7e5a.scene7.com/is/image/metrohm/61613010?$sq-500$&bfc=on
- 6.1613.020
- PCS
- 1
- /shared/en/products/6/1613/61613030
- Bottle / 25 mL / label pH 4 (empty)
- https://s7e5a.scene7.com/is/image/metrohm/61613010?$sq-500$&bfc=on
- 6.1613.030
- PCS
- 1
- /shared/en/products/6/1614/61614000
- Wash bottle / 250 mL
- https://s7e5a.scene7.com/is/image/metrohm/61614000?$sq-500$&bfc=on
- 6.1614.000
- PCS
- 1
- /shared/en/products/6/2008/62008060
- Holder for electrode storage vessel
- https://s7e5a.scene7.com/is/image/metrohm/62008060?$sq-500$&bfc=on
- 6.2008.060
- Practical holder for fastening the electrode storage vessels to the 912, 913 or 914 pH/Conductometers.
- <p>Practical holder for fastening the electrode storage vessels to the 912, 913 or 914 pH/Conductometers.</p>
- PCS
- 1
- /shared/en/products/6/2050/62050010
- Carrying strap for 912/913/914
- https://s7e5a.scene7.com/is/image/metrohm/62050010-2?$sq-500$&bfc=on
- 6.2050.010
- Carrying strap for 912/913/914 meters
- <p>Carrying strap for 912/913/914 meters</p>
- PCS
- 1
- /shared/en/products/6/2151/62151100
- Adapter USB MINI (OTG) - USB A
- https://s7e5a.scene7.com/is/image/metrohm/62151100_1?$sq-500$&bfc=on
- 6.2151.100
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- /shared/en/products/6/2151/62151110
- Metrohm USB Mini B cable (OTG) - USB A, 1.8 m
- https://s7e5a.scene7.com/is/image/metrohm/62151110?$sq-500$&bfc=on
- 6.2151.110
- For connecting USB instruments.
- For connecting USB instruments.
- PCS
- 1
- /shared/en/products/6/2166/62166100
- USB power supply unit 5.25 V / 1.53 A
- https://s7e5a.scene7.com/is/image/metrohm/62166100-2?$sq-500$&bfc=on
- 6.2166.100
- USB power supply unit for 912 / 913 / 914Efficiency Level VI
- <p>USB power supply unit for 912 / 913 / 914</p><p>Efficiency Level VI</p>
- PCS
- 1
- /shared/en/products/6/2308/62308050
- Electrolyte 3 mol/L KCl (50 mL)
- https://metrohm.scene7.com/is/image/metrohm/62308050?$sq-500$&bfc=on
- 6.2308.050
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
- PCS
- 1
- /shared/en/products/6/2324/62324110
- Conductivity standard 100 µS/cm, 5 x 30 mL
- https://s7e5a.scene7.com/is/image/metrohm/62324110_s?$sq-500$&bfc=on
- 6.2324.110
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1
- /shared/en/products/6/2716/62716060
- Case for 912 / 913 / 914
- https://s7e5a.scene7.com/is/image/metrohm/62716060?$sq-500$&bfc=on
- 6.2716.060
- Case for the 912 / 913 / 914 pH/Conductometers.
- <p>Case for the 912 / 913 / 914 pH/Conductometers.</p>
- PCS
- 1
- /shared/en/products/6/2717/62717000
- PP beaker, 100 mL
- https://s7e5a.scene7.com/is/image/metrohm/62717000?$sq-500$&bfc=on
- 6.2717.000
- Beaker made of PP, 100 mL.
- <p>Beaker made of PP, 100 mL.</p>
- PCS
- 1
-
- /shared/en/products/2/1420/21420100
- Custom Q3X thermal printer
- https://metrohm.scene7.com/is/image/metrohm/4859?$sq-500$&bfc=on
- 2.142.0100
- Compact printer with USB interface for 900 Touch Control; 915 KF Ti-Touch; 916 Ti-Touch; 917 Coulometer; 877 / 848 Titrino plus; 865 / 876 Dosimat plus; 91X Meter (cable 6.2151.140); Eco Dosimat / Titrator; 862 Compact Titrosampler; 870 KF Titrino plus; 899 Coulometer; Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.
- <p>Compact printer with USB interface for<br /> </p><ul><li>900 Touch Control</li><li>915 KF Ti-Touch</li><li>916 Ti-Touch</li><li>917 Coulometer</li><li>877 / 848 Titrino plus</li><li>865 / 876 Dosimat plus</li><li>91X Meter (cable 6.2151.140)</li><li>Eco Dosimat / Titrator</li><li>862 Compact Titrosampler</li><li>870 KF Titrino plus</li><li>899 Coulometer</li></ul><p><br />Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.</p>
- PCS
- 1
- /shared/en/products/2/8540/28540010
- 854 iConnect
- https://metrohm.scene7.com/is/image/metrohm/2122_s?$sq-500$&bfc=on
- 2.854.0010
- The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
- <p>The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).</p>
- PCS
- 1
- /shared/en/products/6/0278/60278300
- iUnitrode with Pt1000
- https://s7e5a.scene7.com/is/image/metrohm/60278300_s?$sq-500$&bfc=on
- 6.0278.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:</p><ul><li>for pH measurements and titrations in difficult, viscous, or alkaline samples</li><li>at elevated temperatures</li><li>for long-term measurements</li></ul><p>The fixed ground-joint diaphragm is insensitive to contamination.<br/><br/>Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.<br/>Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
- /shared/en/products/6/0918/60918040
- Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)
- https://s7e5a.scene7.com/is/image/metrohm/60918040?$sq-500$&bfc=on
- 6.0918.040
- Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in, e.g. deion. water.
- <p>Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.<br />This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in, e.g. deion. water.</p>
- PCS
- 1
- /shared/en/products/6/0919/60919140
- Conductivity measuring cell c = 1.6 cm-1 with Pt1000 (fixed cable)
- https://s7e5a.scene7.com/is/image/metrohm/60919140?$sq-500$&bfc=on
- 6.0919.140
- 3-ring conductivity measuring cell with cell constant c = 1.6 cm-1, with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.This sensor is suitable for measurements of high conductivities (0.1 to 1000 mS/cm), e.g., in:sea water; flush water; physiological solutions;
- <p>3-ring conductivity measuring cell with cell constant c = 1.6 cm<sup>-1</sup>, with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.<br/>This sensor is suitable for measurements of high conductivities (0.1 to 1000 mS/cm), e.g., in:</p><ul><li>sea water</li><li>flush water</li><li>physiological solutions</li></ul>
- PCS
- 1
- /shared/en/products/6/2001/62001130
- Stand plate for 912/913/914
- https://s7e5a.scene7.com/is/image/metrohm/62001130?$sq-500$&bfc=on
- 6.2001.130
- Stand plate for converting a mobile 912/913/914 pH/Conductometer into a laboratory meter.
- <p>Stand plate for converting a mobile 912/913/914 pH/Conductometer into a laboratory meter.</p>
- PCS
- 1
- /shared/en/products/6/2151/62151140
- Y cable USB A St - USB B St - Mini B St
- https://s7e5a.scene7.com/is/image/metrohm/62151140?$sq-500$&bfc=on
- 6.2151.140
- Y cable for connection of a USB printer to the pH/Conductometers 912 / 913 / 914. This cable allows a printer and the power supply unit to be connected to the measuring instrument at the same time.
- <p>Y cable for connection of a USB printer to the pH/Conductometers 912 / 913 / 914. This cable allows a printer and the power supply unit to be connected to the measuring instrument at the same time.</p>
- PCS
- 1
- /shared/en/products/6/2166/62166500
- 12 V USB adapter for 912 / 913 / 914 pH/Conductometer
- https://s7e5a.scene7.com/is/image/metrohm/62166500?$sq-500$&bfc=on
- 6.2166.500
- 12 V USB adapter for 912 / 913 / 914 pH/Conductometer.
- <p>12 V USB adapter for 912 / 913 / 914 pH/Conductometer.</p>
- PCS
- 1
- /shared/en/products/6/2325/62325000
- pHit kit
- https://metrohm.scene7.com/is/image/metrohm/62325000?$sq-500$&bfc=on
- 6.2325.000
- Maintenance kit for pH electrodes The kit contains:50 mL cleaning solution; 50 mL 3M KCl solution; 50 mL storage solution; 2 Storage vessels; Instructions for use;
- <p>Maintenance kit for pH electrodes </p><p>The kit contains:</p><ul><li>50 mL cleaning solution</li><li>50 mL 3M KCl solution</li><li>50 mL storage solution</li><li>2 Storage vessels</li><li>Instructions for use</li></ul>
- PCS
- 1
- /shared/en/products/6/2329/62329000
- Oxygen standard 0%
- https://s7e5a.scene7.com/is/image/metrohm/62329000_1?$sq-500$&bfc=on
- 6.2329.000
- Oxygen standard for 0% calibration of the O2-Lumitrode. Contains 5 sachets of 30 mL each.
- <p>Oxygen standard for 0% calibration of the O<sub>2</sub>-Lumitrode. Contains 5 sachets of 30 mL each.</p>
- PCS
- 1
- /shared/en/products/6/5623/65623000
- O2 Lumitrode replacement set
- https://s7e5a.scene7.com/is/image/metrohm/65623000?$sq-500$&bfc=on
- 6.5623.000
- Replacement set for the O2 Lumitrode. The set contains a certified O2 cap as replacement, a calibration vessel, and 5 x 30 mL oxygen standard, 0%.
- <p>Replacement set for the O<sub>2</sub> Lumitrode. The set contains a certified O<sub>2</sub> cap as replacement, a calibration vessel, and 5 x 30 mL oxygen standard, 0%.</p>
- PCS
- 1