854 iConnect
2.854.0010
-
- 854 iConnect
- 1.854.0010
- 854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».
- <p>854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».</p>
- PCS
- 1
-
- Combined iAg-ring electrode
- 6.00450.300
- Intelligent, combined silver ring electrode with integrated memory chip for storing sensor data.This electrode is suitable for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.: chloride, bromide, iodide; sulfides; hydrogen sulfide; mercaptans; cyanides; The fixed ground-joint diaphragm is insensitive to contamination and the permanently fused-in silver ring is resistant to more highly concentrated acids and saline solutions.c(KNO3) = 1 mol/L is used as reference electrolyte and storage solution.
- <p>Intelligent, combined silver ring electrode with integrated memory chip for storing sensor data.<br/>This electrode is suitable for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.:<br/> </p><ul><li>chloride, bromide, iodide</li><li>sulfides</li><li>hydrogen sulfide</li><li>mercaptans</li><li>cyanides</li></ul><p><br/>The fixed ground-joint diaphragm is insensitive to contamination and the permanently fused-in silver ring is resistant to more highly concentrated acids and saline solutions.<br/><br/>c(KNO<sub>3</sub>) = 1 mol/L is used as reference electrolyte and storage solution.</p>
- PCS
- 1
- iAg Titrode
- 6.00470.300
- Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; This electrode is stored in distilled water.Depending on the application, we recommend using an Ag Titrode with Ag2S coating, which can be ordered accordingly.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>This electrode is stored in distilled water.<br/><br/>Depending on the application, we recommend using an Ag Titrode with Ag<sub>2</sub>S coating, which can be ordered accordingly.<br/>iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
- iAg Titrode with AgBr coating
- 6.00470.300BR
- Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.The silver ring is coated with bromide (AgBr) for a higher sensitivity and a better limit of detection.This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; This electrode is stored in distilled water.iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.
- <p>Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>The silver ring is coated with bromide (AgBr) for a higher sensitivity and a better limit of detection.<br/>This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>This electrode is stored in distilled water.<br/>iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.</p>
- PCS
- 1
- iAg Titrode with Ag2S coating
- 6.00470.300S
- Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.The silver ring is coated with sulfide (Ag2S) for higher sensitivity and a better limit of detection.This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; This electrode is stored in distilled water.iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.
- <p>Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>The silver ring is coated with sulfide (Ag<sub>2</sub>S) for higher sensitivity and a better limit of detection.<br/>This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate), for example of:<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>This electrode is stored in distilled water.<br/>iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.</p>
- PCS
- 1
- iAquatrode Plus with Pt1000
- 6.0277.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. <br/><br/>The fixed ground-joint diaphragm is insensitive to contamination. <br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iUnitrode with Pt1000
- 6.0278.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:</p><ul><li>for pH measurements and titrations in difficult, viscous, or alkaline samples</li><li>at elevated temperatures</li><li>for long-term measurements</li></ul><p>The fixed ground-joint diaphragm is insensitive to contamination.<br/><br/>Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.<br/>Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
- iSolvotrode
- 6.0279.300
- Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. <br/>The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.<br/>iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.</p>
- PCS
- 1
- iEcotrode Plus
- 6.0280.300
- Intelligent, combined pH electrode with integrated memory chip for storing of sensor data. This electrode is suitable for aqueous acid/base titrations. The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined pH electrode with integrated memory chip for storing of sensor data. This electrode is suitable for aqueous acid/base titrations. <br/><br/>The fixed ground-joint diaphragm is insensitive to contamination.<br/>Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.<br/>iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
- Combined iPt ring electrode
- 6.0451.300
- Intelligent, combined platinum ring electrode with integrated memory chip for storing sensor data.This electrode is suitable for redox titrations where the pH value varies, e.g.: Oxygen content according to Winkler; Determination of hydrogen peroxide with KMnO4; Diazotization titrations; c(KCl) = 3 mol/L is used as reference electrolyte and for storage.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
- <p>Intelligent, combined platinum ring electrode with integrated memory chip for storing sensor data.<br/>This electrode is suitable for redox titrations where the pH value varies, e.g.:<br/> </p><ul><li>Oxygen content according to Winkler</li><li>Determination of hydrogen peroxide with KMnO<sub>4</sub></li><li>Diazotization titrations</li></ul><p><br/>c(KCl) = 3 mol/L is used as reference electrolyte and for storage.<br/>iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.</p>
- PCS
- 1
- iPt Titrode
- 6.0471.300
- Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.: Iodometry; Chromatometry; Cerimetry; Permanganometry; This electrode is stored in distilled water.iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.
- <p>Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data.<br/>This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.:<br/> </p><ul><li>Iodometry</li><li>Chromatometry</li><li>Cerimetry</li><li>Permanganometry</li></ul><p><br/>This electrode is stored in distilled water.<br/>iTrodes can be used on Titrando, Ti-Touch oder 913/914 meters.</p>
- PCS
- 1