914 pH/DO/Conductometer with accessories case
2.914.0130
4.74
/ 5.0 32 Reviews på SelectScience
- Overblik over funktioner
- Tekniske specifikationer
Portable 2-channel pH/DO/conductivity measuring instrument with analog and digital measuring input for parallel measurements of pH/mV/conductivity or dissolved oxygen and conductivity. You will be optimally equipped for measurements outdoors with this battery-operated measuring instrument in a transport case.
- Parallel measurement of pH value and conductivity
- Parallel measurement of dissolved oxygen and conductivity
- Analog conductivity measuring input for the 4-conductor conductivity measuring cells from Metrohm
- Digital measuring input for the intelligent pH electrodes and O2 Lumitrode
- Robust, water-tight, and dust-tight housing (IP67) for hard outdoor and laboratory use
- LCD color display with background illumination making results easy to read
- USB interface for simple data export to PC or printer
- Large internal memory (10,000 data sets)
- Pin-protected User mode and Expert mode, prevents unwanted parameter changes
- GLP-compliant printout and data export with User ID and timestamp
- Robust transport case for routine measurements in the field
Portable 2-channel pH/DO/conductivity measuring instrument with analog and digital measuring input for parallel measurements of pH/mV/conductivity or dissolved oxygen and conductivity. You will be optimally equipped for measurements outdoors with this battery-operated measuring instrument in a transport case.
- Parallel measurement of pH value and conductivity
- Parallel measurement of dissolved oxygen and conductivity
- Analog conductivity measuring input for the 4-conductor conductivity measuring cells from Metrohm
- Digital measuring input for the intelligent pH electrodes and O2 Lumitrode
- Robust, water-tight, and dust-tight housing (IP67) for hard outdoor and laboratory use
- LCD color display with background illumination making results easy to read
- USB interface for simple data export to PC or printer
- Large internal memory (10,000 data sets)
- Pin-protected User mode and Expert mode, prevents unwanted parameter changes
- GLP-compliant printout and data export with User ID and timestamp
- Robust transport case for routine measurements in the field
Få mere at vide Detail
Bærbare og stationære metre (912, 913, 914)
Robuste, bærbare pH-metre, ledningsevnemetre og kombinerede oxygenmetre til brug på stedet eller i laboratoriet.Hvorfor? Bærbare og stationære metre (912, 913, 914)?
Udstyr Din 914 pH/DO/Conductometer with accessories case
Download PDF med tilbehør







- Inkluderede dele
- Valgfrie dele
Case for 912 / 913 / 914
6.2716.060
Case for the 912 / 913 / 914 pH/Conductometers.
O2 Lumitrode
6.1116.000
The optical sensor for measuring dissolved oxygen (DO) can be used with a 913 pH/DO meter or with a 914 pH/DO conductometer. The measuring principle of the sensor is based on luminescence quenching. The space-saving and maintenance-free sensor is suitable for DO measurement, for example in: Water quality control; Wastewater industry; Beverage production; Fish farming; This sensor is supplied with a calibration vessel. Where necessary, it is easy to replace the measurement cap (O2 cap) that contains the oxygen-intensive luminophore.
Conductivity standard 100 µS/cm, 5 x 30 mL
6.2324.110
Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
Electrolyte 3 mol/L KCl (50 mL)
6.2308.050
Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)
Vis mere
Custom Q3X thermal printer
2.142.0100
Compact printer with USB interface for 900 Touch Control; 915 KF Ti-Touch; 916 Ti-Touch; 917 Coulometer; 877 / 848 Titrino plus; 865 / 876 Dosimat plus; 91X Meter (cable 6.2151.140); Eco Dosimat / Titrator; 862 Compact Titrosampler; 870 KF Titrino plus; 899 Coulometer; Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.
iUnitrode with Pt1000
6.0278.300
Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
854 iConnect
2.854.0010
The 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)
6.0918.040
Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in, e.g. deion. water.
Vis mere