Feature overview

The i-Raman Plus 785S is a high-resolution, research-grade Raman spectrometer designed for precision and versatility in a compact, portable form. Equipped with a 785 nm laser and a wide spectral range from 65 to 3350 cm⁻¹, it provides excellent performance for both qualitative and quantitative analyses. Its TE-cooled CCD detector ensures low-noise measurements—even during extended integration times - making it ideal for detecting weak Raman signals in applications such as art conservation, mineralogy, and SERS.

The system supports flexible sampling using a fiber optic probe and accessories such as a cuvette holder, video microscope, and XYZ stage. Powered by SpecSuite software, the 785S provides sophisticated data analysis and spectral identification.

The i-Raman Plus 785S is the ideal choice for teams requiring reliable Raman analysis across a wide spectral range in challenging operational environments, from lab research to field research.

Discover how the i-Raman Plus delivers research-grade Raman in an accessible package:

  • Wide spectral coverage and high-resolution spectrometer configurations.
  • The system’s small footprint, lightweight design, and low power consumption ensure research-grade Raman analysis capabilities at any location.
  • The i-Raman Plus is equipped with a fiber probe for easy sampling, and can be used with a cuvette holder, a video microscope, an XYZ positioning stage with a probe holder.
  • The i-Raman Plus is supported by SpecSuite software for easy Raman data collection in addition to quantitative model building, identification with spectral libraries, and routine analysis.

    • Polystyrene Validation Cap
    • 607510040
    • Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.
    • <p>Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.</p>
    • PCS
    • 1
    • Laser key for i-Raman NxG
    • 607510050
    • Laser keys for i-Raman NxG and i-Raman Duo systems.
    • <p>Laser keys for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • Interlock Plug for i-Raman NxG
    • 607510010
    • Interlock plug for i-Raman NxG and i-Raman Duo systems.
    • <p>Interlock plug for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • AC Power Cord for i-Raman Series
    • 607510060
    • AC power cord for i-Raman NxG and i-Raman Duo systems.
    • <p>AC power cord for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • USB-C to USB-C cable for i-Raman NxG
    • 607510030
    • USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.
    • <p>USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • Lab-Grade Raman Probe (785 nm)
    • 607510450
    • Lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length. Compatible with i-Raman Plus 785S and 785HR models.
    • <p>Lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length. Compatible with i-Raman Plus 785S and 785HR models.</p>
    • PCS
    • 1
    • Polystyrene Validation Cap
    • 607510040
    • Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.
    • <p>Validation cap with integrated polystyrene standard for lab-grade Raman probes with shaft diameter of 9.5 mm.</p>
    • PCS
    • 1
    • Laser key for i-Raman NxG
    • 607510050
    • Laser keys for i-Raman NxG and i-Raman Duo systems.
    • <p>Laser keys for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • Interlock Plug for i-Raman NxG
    • 607510010
    • Interlock plug for i-Raman NxG and i-Raman Duo systems.
    • <p>Interlock plug for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • AC Power Cord for i-Raman Series
    • 607510060
    • AC power cord for i-Raman NxG and i-Raman Duo systems.
    • <p>AC power cord for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • USB-C to USB-C cable for i-Raman NxG
    • 607510030
    • USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.
    • <p>USB-C to USB-C cable for i-Raman NxG and i-Raman Duo systems.</p>
    • PCS
    • 1
    • Lab-Grade Raman Probe (785 nm)
    • 607510450
    • Lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length. Compatible with i-Raman Plus 785S and 785HR models.
    • <p>Lab-grade fiber optic Raman probe assembly with trigger button. 1.5 meter fiber length. Compatible with i-Raman Plus 785S and 785HR models.</p>
    • PCS
    • 1
    • SpecSuite Software License - Laboratory Software Quantification
    • 66079160
    • SpecSuite license for quantification. Includes quantitative model development module and routine analysis prediction.
    • <p>SpecSuite license for quantification. Includes quantitative model development module and routine analysis prediction.</p>
    • PCS
    • 1
    • SpecSuite Comprehensive Library
    • 66079180
    • SpecSuite Metrohm Comprehensive Raman Library - More than 27,700 spectral entries of chemicals, minerals, organic chemicals, solvents, polymers, dyes and pigments, TICs, TIMs, inorganics and organometallics, personal care products, and illicit materials.
    • <p>SpecSuite Metrohm Comprehensive Raman Library - More than 27,700 spectral entries of chemicals, minerals, organic chemicals, solvents, polymers, dyes and pigments, TICs, TIMs, inorganics and organometallics, personal care products, and illicit materials.</p>
    • PCS
    • 1
    • SpecSuite MCRL Organics Complete Library
    • 66079200
    • Metrohm Comprehensive Raman Library (MCRL) Organics for SpecSuite software.
    • <p>Metrohm Comprehensive Raman Library (MCRL) Organics for SpecSuite software.</p>
    • PCS
    • 1
    • SpecSuite MCRL Dyes, Pigments, and Stains Library
    • 66079230
    • Metrohm Comprehensive Raman Library (MCRL) Dyes, Pigments, and Stains for SpecSuite software.
    • <p>Metrohm Comprehensive Raman Library (MCRL) Dyes, Pigments, and Stains for SpecSuite software.</p>
    • PCS
    • 1
    • SpecSuite Minerals Library
    • 66079240
    • Metrohm Minerals library for SpecSuite software.
    • <p>Metrohm Minerals library for SpecSuite software.</p>
    • PCS
    • 1
    • SpecSuite Comprehensive USP Library
    • 66079250
    • Metrohm Comprehensive USP Raman Library for SpecSuite containing ~ 900 traceable certified items.
    • <p>Metrohm Comprehensive USP Raman Library for SpecSuite containing ~ 900 traceable certified items.</p>
    • PCS
    • 1
    • SpecSuite Illicit and General Chemicals Library
    • 66079260
    • Metrohm Illicit and General Chemicals Raman Library for SpecSuite software. Includes drugs, TICs, TIMs, precursors, and general chemicals.
    • <p>Metrohm Illicit and General Chemicals Raman Library for SpecSuite software. Includes drugs, TICs, TIMs, precursors, and general chemicals.</p>
    • PCS
    • 1
    • SpecSuite CWA Library
    • 66079280
    • Chemical warfare agents (CWA) library for SpecSuite software.
    • <p>Chemical warfare agents (CWA) library for SpecSuite software.</p>
    • PCS
    • 1
    • Vial Holder Accessory
    • 607510410
    • Vial holder accessory for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with 15 mm-diameter vial. 6-pack of 15 mm borosilicate glass vials included.
    • <p>Vial holder accessory for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with 15 mm-diameter vial. 6-pack of 15 mm borosilicate glass vials included.</p>
    • PCS
    • 1
    • Cuvette Holder Accessory
    • 607510420
    • Cuvette holder for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with standard cuvettes of 12.5 mm x 12.5 mm outer diameter (1 cm path length) for sampling liquids or powders.
    • <p>Cuvette holder for use with lab-grade Raman probes with shaft diameter of 9.5 mm. Compatible with standard cuvettes of 12.5 mm x 12.5 mm outer diameter (1 cm path length) for sampling liquids or powders.</p>
    • PCS
    • 1
    • Distance Regulator Cap
    • 607510430
    • Distance regulator cap for standard lab-grade Raman probe shaft.
    • <p>Distance regulator cap for standard lab-grade Raman probe shaft.</p>
    • PCS
    • 1
    • Standard Shaft for Lab-Grade Probe (785 nm)
    • 607510220
    • Replacement shaft for 785 nm excitation lab-grade Raman probe assembly. Working distance 5.5 mm.
    • <p>Replacement shaft for 785 nm excitation lab-grade Raman probe assembly. Working distance 5.5 mm.</p>
    • PCS
    • 1
    • Hastelloy Immersion Shaft for Lab-grade Raman Probe
    • 607510240
    • C-276 Hastelloy immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.
    • <p>C-276 Hastelloy immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.</p>
    • PCS
    • 1
    • Stainless Steel Immersion Shaft for Lab-grade Raman Probe
    • 607511010
    • 316 Stainless steel immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.
    • <p>316 Stainless steel immersion shaft compatible with lab-grade Raman probes. Includes adjustable shaft adapter. Compatible with 532, 785, 860 and 1064 nm wavelengths.</p>
    • PCS
    • 1