You have been redirected to your local version of the requested page
OMNIS Professional Titrator with magnetic stirrer

OMNIS Professional Titrator with magnetic stirrer

2.1001.0320

    • OMNIS Liquid Adapter
    • 6.01600.010
    • Adapter for connecting reagent bottles with 3S technology to an OMNIS Titrator, Titration Module or Dosing Module.
    • <p>Adapter for connecting reagent bottles with 3S technology to an OMNIS Titrator, Titration Module or Dosing Module.</p>
    • PCS
    • 1
    • Bottle cap, multi-use
    • 6.01601.000
    • Reusable bottle cap with 3S technology for connecting reagent bottles to an OMNIS Titrator, Titration Module or Dosing Module.
    • <p>Reusable bottle cap with 3S technology for connecting reagent bottles to an OMNIS Titrator, Titration Module or Dosing Module.</p>
    • PCS
    • 1
    • Bottle holder
    • 6.02004.010
    • Bottle holder for OMNIS Titrator, Titration Module and Dosing Module.
    • <p>Bottle holder for OMNIS Titrator, Titration Module and Dosing Module.</p>
    • PCS
    • 1
    • OMNIS electrode holder
    • 6.02005.000
    • Electrode holder for one OMNIS titration system.
    • <p>Electrode holder for one OMNIS titration system.</p>
    • PCS
    • 1
    • Electrode Parking Station
    • 6.02005.010
    • Electrode Parking Station for electrode storage on an OMNIS titration system.
    • <p>Electrode Parking Station for electrode storage on an OMNIS titration system.</p>
    • PCS
    • 1
    • Function license Professional
    • 6.06001.920
    • Function license "Professional" for one OMNIS Titrator Liquid Handling (LQH); MEAS U/T/pH; MEAS CONC (direct measurement and standard addition); Calibration (Cal); Endpoint titration without conditioning (SET); Monotonic equivalence point titration (MET); Dynamic equivalence point titration (DET); Titration with OMNIS Titration Module or OMNIS Dosing Module; Parallel dosing; Parallel titration;  
    • <p>Function license "Professional" for one OMNIS Titrator<br/><br/> </p><ul><li>Liquid Handling (LQH)</li><li>MEAS U/T/pH</li><li>MEAS CONC (direct measurement and standard addition)</li><li>Calibration (Cal)</li><li>Endpoint titration without conditioning (SET)</li><li>Monotonic equivalence point titration (MET)</li><li>Dynamic equivalence point titration (DET)</li><li>Titration with OMNIS Titration Module or OMNIS Dosing Module</li><li>Parallel dosing</li><li>Parallel titration</li></ul><p> </p>
    • PCS
    • 1
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Stirring bar / 16 mm
    • 6.1903.020
    • Stirring Bar with magnetic core, PTFE coated, length 16 mm
    • Stirring Bar with magnetic core, PTFE coated, length 16 mm
    • PCS
    • 1
    • Stirring bar / 25 mm
    • 6.1903.030
    • Stirring bar with magnetic core, PTFE covering, length 25 mm.
    • <p>Stirring bar with magnetic core, PTFE covering, length 25 mm.</p>
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • OMNIS Liquid Adapter
    • 6.01600.010
    • Adapter for connecting reagent bottles with 3S technology to an OMNIS Titrator, Titration Module or Dosing Module.
    • <p>Adapter for connecting reagent bottles with 3S technology to an OMNIS Titrator, Titration Module or Dosing Module.</p>
    • PCS
    • 1
    • Bottle cap, multi-use
    • 6.01601.000
    • Reusable bottle cap with 3S technology for connecting reagent bottles to an OMNIS Titrator, Titration Module or Dosing Module.
    • <p>Reusable bottle cap with 3S technology for connecting reagent bottles to an OMNIS Titrator, Titration Module or Dosing Module.</p>
    • PCS
    • 1
    • Bottle holder
    • 6.02004.010
    • Bottle holder for OMNIS Titrator, Titration Module and Dosing Module.
    • <p>Bottle holder for OMNIS Titrator, Titration Module and Dosing Module.</p>
    • PCS
    • 1
    • OMNIS electrode holder
    • 6.02005.000
    • Electrode holder for one OMNIS titration system.
    • <p>Electrode holder for one OMNIS titration system.</p>
    • PCS
    • 1
    • Electrode Parking Station
    • 6.02005.010
    • Electrode Parking Station for electrode storage on an OMNIS titration system.
    • <p>Electrode Parking Station for electrode storage on an OMNIS titration system.</p>
    • PCS
    • 1
    • Function license Professional
    • 6.06001.920
    • Function license "Professional" for one OMNIS Titrator Liquid Handling (LQH); MEAS U/T/pH; MEAS CONC (direct measurement and standard addition); Calibration (Cal); Endpoint titration without conditioning (SET); Monotonic equivalence point titration (MET); Dynamic equivalence point titration (DET); Titration with OMNIS Titration Module or OMNIS Dosing Module; Parallel dosing; Parallel titration;  
    • <p>Function license "Professional" for one OMNIS Titrator<br/><br/> </p><ul><li>Liquid Handling (LQH)</li><li>MEAS U/T/pH</li><li>MEAS CONC (direct measurement and standard addition)</li><li>Calibration (Cal)</li><li>Endpoint titration without conditioning (SET)</li><li>Monotonic equivalence point titration (MET)</li><li>Dynamic equivalence point titration (DET)</li><li>Titration with OMNIS Titration Module or OMNIS Dosing Module</li><li>Parallel dosing</li><li>Parallel titration</li></ul><p> </p>
    • PCS
    • 1
    • Piston tongs
    • 6.1546.030
    • For pistons for 807 Dosing Units or cylinder units OMNIS.
    • <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
    • PCS
    • 1
    • Stirring bar / 16 mm
    • 6.1903.020
    • Stirring Bar with magnetic core, PTFE coated, length 16 mm
    • Stirring Bar with magnetic core, PTFE coated, length 16 mm
    • PCS
    • 1
    • Stirring bar / 25 mm
    • 6.1903.030
    • Stirring bar with magnetic core, PTFE covering, length 25 mm.
    • <p>Stirring bar with magnetic core, PTFE covering, length 25 mm.</p>
    • PCS
    • 1
    • Clamping ring
    • 6.2013.010
    • For support rods with a diameter of 10 mm.
    • <p>For support rods with a diameter of 10 mm.</p>
    • PCS
    • 1
    • OMNIS Titration Module without stirrer
    • 2.1002.0010
    • Titration module for connection to an OMNIS Titrator for extending the system to include an additional buret for titration/dosing and up to two measuring modules (analog or digital). Can be supplemented with one magnetic stirrer or rod stirrer for use as separate titration stand. Freely selectable cylinder unit with 5, 10, 20 or 50 mL.
    • <p>Titration module for connection to an OMNIS Titrator for extending the system to include an additional buret for titration/dosing and up to two measuring modules (analog or digital). Can be supplemented with one magnetic stirrer or rod stirrer for use as separate titration stand. Freely selectable cylinder unit with 5, 10, 20 or 50 mL.</p>
    • PCS
    • 1
    • OMNIS Titration Module with magnetic stirrer
    • 2.1002.0110
    • Titration module with magnetic stirrer for connection to an OMNIS Titrator for extending the system to include an additional titration stand, a buret for titration/dosing and up to two measuring modules (analog or digital). Freely selectable cylinder unit with 5, 10, 20 or 50 mL.
    • <p>Titration module with magnetic stirrer for connection to an OMNIS Titrator for extending the system to include an additional titration stand, a buret for titration/dosing and up to two measuring modules (analog or digital). Freely selectable cylinder unit with 5, 10, 20 or 50 mL.</p>
    • PCS
    • 1
    • OMNIS Dosing Module without stirrer
    • 2.1003.0010
    • Dosing module for connection to an OMNIS Titrator for extending the system to include an additional buret for titration/dosing. Can be supplemented with one magnetic stirrer or rod stirrer for use as separate titration stand. Freely selectable cylinder unit with 5, 10, 20 or 50 mL.
    • <p>Dosing module for connection to an OMNIS Titrator for extending the system to include an additional buret for titration/dosing. Can be supplemented with one magnetic stirrer or rod stirrer for use as separate titration stand. Freely selectable cylinder unit with 5, 10, 20 or 50 mL.</p>
    • PCS
    • 1
    • OMNIS Dosing Module with magnetic stirrer
    • 2.1003.0110
    • Dosing module with magnetic stirrer for connection to an OMNIS Titrator for extending the system to include an additional titration stand and a buret for titration/dosing. Freely selectable cylinder unit with 5, 10, 20 or 50 mL.
    • <p>Dosing module with magnetic stirrer for connection to an OMNIS Titrator for extending the system to include an additional titration stand and a buret for titration/dosing. Freely selectable cylinder unit with 5, 10, 20 or 50 mL.</p>
    • PCS
    • 1
    • dUnitrode with Pt1000
    • 6.00200.300
    • Digital, combined pH electrode for OMNIS with integrated Pt1000 temperature sensor. This electrode is particularly suitable for :- pH measurements and titrations in difficult, viscous, or alkaline samples- at elevated temperatures- long-term measurementsThe fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: Reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.dTrodes can be used on OMNIS Titrators.
    • <p>Digital, combined pH electrode for OMNIS with integrated Pt1000 temperature sensor. This electrode is particularly suitable for :<br/>- pH measurements and titrations in difficult, viscous, or alkaline samples<br/>- at elevated temperatures<br/>- long-term measurements<br/>The fixed ground-joint diaphragm is insensitive to contamination.</p><p>Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.<br/>Alternatively: Reference electrolyte for measurements at T&gt;80°C: Idrolyte, storage in Idrolyte.<br/>dTrodes can be used on OMNIS Titrators.</p>
    • PCS
    • 1
    • dEcotrode Plus
    • 6.00201.300
    • Digital, combined pH electrode for OMNIS.The electrode is suitable for aqueous acid/base titrations. The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.dTrodes can be used on OMNIS Titrators.
    • <p>Digital, combined pH electrode for OMNIS.<br/>The electrode is suitable for aqueous acid/base titrations. <br/>The fixed ground-joint diaphragm is insensitive to contamination.<br/>Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.<br/>dTrodes can be used on OMNIS Titrators.</p>
    • PCS
    • 1
    • dAquatrode Plus with Pt1000
    • 6.00202.300
    • Digital, combined pH electrode for OMNIS, with integrated Pt1000 temperature sensor, for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the bridge electrolyte used.dTrodes can be used on OMNIS Titrators.
    • <p>Digital, combined pH electrode for OMNIS, with integrated Pt1000 temperature sensor, for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. <br/>The fixed ground-joint diaphragm is insensitive to contamination. <br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the bridge electrolyte used.<br/>dTrodes can be used on OMNIS Titrators.</p>
    • PCS
    • 1
    • dSolvotrode
    • 6.00203.300
    • Digital, combined pH electrode for OMNIS for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions and thanks to the flexible ground-joint diaphragm, the electrode is suitable for contaminated samples.This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide).Storage in corresponding reference electrolyte.dTrodes can be used on OMNIS Titrators. 
    • <p>Digital, combined pH electrode for OMNIS for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions and thanks to the flexible ground-joint diaphragm, the electrode is suitable for contaminated samples.<br/><br/>This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide).<br/><br/>Storage in corresponding reference electrolyte.<br/>dTrodes can be used on OMNIS Titrators.<br/> </p>
    • PCS
    • 1
    • dProfitrode
    • 6.00204.300
    • Digital, combined pH electrode for OMNIS with double-junction system. This electrode is suitable for pH measurements/titrations of samplesthat contaminate the reference system of the electrode (e.g., galvanic baths, samples containing sulfides); for which potassium chloride c(KCl) = 3 mol/L cannot be used as reference electrolyte (e.g., reaction of potassium or chloride with sample); The electrode is equipped with a flexible ground-joint diaphragm which is insensitive to contamination and which can be exchanged when needed.When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a suitable electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the bridge electrolyte used.dTrodes can be used on OMNIS Titrators.
    • <p>Digital, combined pH electrode for OMNIS with double-junction system. This electrode is suitable for pH measurements/titrations of samples</p><ul><li>that contaminate the reference system of the electrode (e.g., galvanic baths, samples containing sulfides)</li><li>for which potassium chloride c(KCl) = 3 mol/L cannot be used as reference electrolyte (e.g., reaction of potassium or chloride with sample)</li></ul><p>The electrode is equipped with a flexible ground-joint diaphragm which is insensitive to contamination and which can be exchanged when needed.<br/>When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.<br/>The bridge electrolyte can be easily replaced with a suitable electrolyte (e.g., potassium nitrate c(KNO<sub>3</sub>) = 1 mol/L (6.2310.010)). Storage in the bridge electrolyte used.<br/>dTrodes can be used on OMNIS Titrators.</p>
    • PCS
    • 1
    • dPt Titrode
    • 6.00401.300
    • Digital, combined platinum ring electrode for OMNIS with a pH glass membrane as reference electrode.This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.: Iodometry; Chromatometry; Cerimetry; Permanganometry; This electrode is stored in distilled water.dTrodes can be used on OMNIS Titrators. 
    • <p>Digital, combined platinum ring electrode for OMNIS with a pH glass membrane as reference electrode.<br/>This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.:<br/> </p><ul><li>Iodometry</li><li>Chromatometry</li><li>Cerimetry</li><li>Permanganometry</li></ul><p><br/>This electrode is stored in distilled water.<br/>dTrodes can be used on OMNIS Titrators.<br/> </p>
    • PCS
    • 1
    • dAg ring electrode
    • 6.00402.300
    • Digital, combined silver ring electrode for OMNIS with fixed ground-joint diaphragm.This electrode is suitable for precipitation titrations where the pH value varies (titrant silver nitrate) of, e.g. Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; The fixed ground-joint diaphragm is insensitive to contamination. c(KNO3) = 1 mol/ L is used as reference electrolyte and for storage.dTrodes can be used on OMNIS Titrators.
    • <p>Digital, combined silver ring electrode for OMNIS with fixed ground-joint diaphragm.<br/>This electrode is suitable for precipitation titrations where the pH value varies (titrant silver nitrate) of, e.g.<br/> </p><ul><li>Chloride, Bromide, Iodide</li><li>Sulfides</li><li>Hydrogen sulfide</li><li>Mercaptans</li><li>Cyanides</li></ul><p><br/>The fixed ground-joint diaphragm is insensitive to contamination. c(KNO<sub>3</sub>) = 1 mol/ L is used as reference electrolyte and for storage.<br/>dTrodes can be used on OMNIS Titrators.</p>
    • PCS
    • 1
    • dPt ring electrode
    • 6.00403.300
    • Digital, combined platinum ring electrode for OMNIS with fixed ground-joint diaphragm.This electrode is suitable for redox titrations when the pH value varies, e.g.: Oxygen content according to Winkler; Determination of hydrogen peroxide with KMnO4; Diazotization titrations; The fixed ground-joint diaphragm is insensitive to contamination. c(KCl) = 3 mol/ L is used as reference electrolyte and for storage.dTrodes can be used on OMNIS Titrators.
    • <p>Digital, combined platinum ring electrode for OMNIS with fixed ground-joint diaphragm.<br/>This electrode is suitable for redox titrations when the pH value varies, e.g.:<br/> </p><ul><li>Oxygen content according to Winkler</li><li>Determination of hydrogen peroxide with KMnO<sub>4</sub></li><li>Diazotization titrations</li></ul><p><br/>The fixed ground-joint diaphragm is insensitive to contamination. c(KCl) = 3 mol/ L is used as reference electrolyte and for storage.<br/>dTrodes can be used on OMNIS Titrators.</p>
    • PCS
    • 1
    • Combined dCa ISE
    • 6.00502.300
    • Digital, combined calcium-selective electrode for OMNIS. This ISE is suitable for: Ion measurements of Ca2+ (1*10-7 to 1 mol/L) in aqueous solutions; Complexometric (back) titrations (e.g., determination of water hardness); Thanks to a robust/break-proof plastic shaft made of propylene and an impact protection for the polymer membrane, this sensor is mechanically very resistant.The reference electrolyte used is c(KCl) = 3 mol/L.dTrodes can be used on OMNIS Titrators.
    • <p>Digital, combined calcium-selective electrode for OMNIS. <br/>This ISE is suitable for:<br/> </p><ul><li>Ion measurements of Ca<sup>2+</sup> (1*10<sup>-7</sup> to 1 mol/L) in aqueous solutions</li><li>Complexometric (back) titrations (e.g., determination of water hardness)</li></ul><p><br/>Thanks to a robust/break-proof plastic shaft made of propylene and an impact protection for the polymer membrane, this sensor is mechanically very resistant.<br/>The reference electrolyte used is c(KCl) = 3 mol/L.<br/>dTrodes can be used on OMNIS Titrators.</p>
    • PCS
    • 1
    • OMNIS 2 mL cylinder unit without accessories
    • 6.01503.120
    • Intelligent 2 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.
    • <p>Intelligent 2 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • OMNIS 5 mL cylinder unit without accessories
    • 6.01503.150
    • Intelligent 5 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.
    • <p>Intelligent 5 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • OMNIS 10 mL cylinder unit without accessories
    • 6.01503.210
    • Intelligent 10 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.
    • <p>Intelligent 10 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • OMNIS 20 mL cylinder unit without accessories
    • 6.01503.220
    • Intelligent 20 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.
    • <p>Intelligent 20 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • OMNIS 50 mL cylinder unit without accessories
    • 6.01503.250
    • Intelligent 50 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.
    • <p>Intelligent 50 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • Measuring module digital
    • 6.02100.010
    • Digital measurement channel for one OMNIS Titrator or Titration Module for the connection of digital "dTrodes" electrodes.
    • <p>Digital measurement channel for one OMNIS Titrator or Titration Module for the connection of digital "dTrodes" electrodes.</p>
    • PCS
    • 1
    • Measuring module analog
    • 6.02101.011
    • Analog measurement channel for one OMNIS Titrator or Titration Module for the connection of analog electrodes. Compatible with OMNIS software version 2.18 or higher.
    • <p>Analog measurement channel for one OMNIS Titrator or Titration Module for the connection of analog electrodes. Compatible with OMNIS software version 2.18 or higher.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 0.55 m
    • 6.02104.000
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G / plug P, 1.5 m
    • 6.02104.010
    • Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G (pol.) / plug P, 0.55 m
    • 6.02104.040
    • Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head G (pol.) / plug P, 1.5 m
    • 6.02104.050
    • Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.
    • <p>Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 0.55 m
    • 6.02104.300
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 1.5 m
    • 6.02104.310
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head U / plug P, 0.55 m
    • 6.02104.600
    • Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.
    • <p>Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head U / plug P, 1.5 m
    • 6.02104.610
    • Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.
    • <p>Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.</p>
    • PCS
    • 1
    • Liquid Adapter extension cable, 0.55 m
    • 6.02106.000
    • Extension cable (0.55 m in length) for connecting an OMNIS Liquid Adapter to an OMNIS Titrator, Titration Module or Dosing Module.
    • <p>Extension cable (0.55 m in length) for connecting an OMNIS Liquid Adapter to an OMNIS Titrator, Titration Module or Dosing Module.</p>
    • PCS
    • 1
    • Liquid Adapter extension cable, 2 m
    • 6.02106.010
    • Extension cable (2 m in length) for connecting an OMNIS Liquid Adapter to an OMNIS Titrator, Titration Module or Dosing Module.
    • <p>Extension cable (2 m in length) for connecting an OMNIS Liquid Adapter to an OMNIS Titrator, Titration Module or Dosing Module.</p>
    • PCS
    • 1
    • Cylinder unit OMNIS 2 mL
    • 6.03001.120
    • Intelligent 2 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.
    • <p>Intelligent 2 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • Cylinder unit OMNIS 5 mL
    • 6.03001.150
    • Intelligent 5 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.
    • <p>Intelligent 5 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • Cylinder unit OMNIS 10 mL
    • 6.03001.210
    • Intelligent 10 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.
    • <p>Intelligent 10 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • Cylinder unit OMNIS 20 mL
    • 6.03001.220
    • Intelligent 20 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.
    • <p>Intelligent 20 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • Cylinder unit OMNIS 50 mL
    • 6.03001.250
    • Intelligent 50 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.
    • <p>Intelligent 50 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.</p>
    • PCS
    • 1
    • KFT equipment for OMNIS Titrator
    • 6.05609.000
    • Complete accessory set for volumetric Karl Fischer titration.
    • <p>Complete accessory set for volumetric Karl Fischer titration.</p>
    • PCS
    • 1
    • Function license KFT with conditioning
    • 6.06001.160
    • Function license for volumetric Karl Fischer titration with conditioning for an OMNIS titration system.
    • <p>Function license for volumetric Karl Fischer titration with conditioning for an OMNIS titration system.</p>
    • PCS
    • 1