Automated hydroxide eluent production takes place with the 948 Continuous IC Module. Isocratic eluents can be produced and gradients can be run.
The 948 Continuous IC Module, CEP is comprised of the following parts:
- 948 Continuous IC Module
- Eluent Producer Cartridge (EPC, 6.02850.200)
- Continuous anion trap (CT, 6.02850.100)
- High-pressure degasser (H-DEG, 6.02850.000)
Example methods according to 948 Continuous IC Module manual.
Automated hydroxide eluent production takes place with the 948 Continuous IC Module. Isocratic eluents can be produced and gradients can be run.
The 948 Continuous IC Module, CEP is comprised of the following parts:
- 948 Continuous IC Module
- Eluent Producer Cartridge (EPC, 6.02850.200)
- Continuous anion trap (CT, 6.02850.100)
- High-pressure degasser (H-DEG, 6.02850.000)
Example methods according to 948 Continuous IC Module manual.
Daha yakından tanıyın Detail
IC için otomasyon
Örnek sayınız ve ön hazırlık işleminiz ne olursa olsun, iyon kromatografi sistemleriniz için ihtiyaçlarınızı karşılayabilecek otomasyon çözümünü sizlere sunuyoruz.Neden? IC için otomasyon?
Ekipmanlar Size özel 948 Continuous IC Module, CEP
Aksesuarlar PDF dosyasını indir







- Dahili parçalar
- Opsiyonel parçalar
High-pressure degasser
6.02850.000
The high-pressure degasser is responsible for the elimination of the hydrogen gas that is formed during eluent production.
Continuous anion trap (CT)
6.02850.100
The continuous anion trap (CT-A) removes anionic contamination and carbonate from the eluent.
Eluent producer cartridge A
6.02850.200
The eluent producer cartridge A (EPC A) produces the high-purity hydroxide eluent from the 4 mol/L hydroxide concentrate, based on water electrolysis. The cation exchanger diaphragm enables the selective migration of cations into the eluent. The EPC A is fed ultrapure water, which can be operated fully automatically in connection with a water processing system.
Accessory kit: CEP
6.05000.300
Accessory kit for installation of the 948 Continuous IC Module, CEP
Daha fazlası
Bottle PE / 1000 mL / GL 45
6.1608.040
For Exchange Units. Bottle for auxiliary solutions.
MSM-HC Rotor A, Hydroxide
6.2842.100
Suppressor rotor with high capacity for hydroxide eluents for all IC instruments with MSM-HC (Metrohm Suppressor Module with high capacity).
Metrosep A Supp 19 - 150/4.0
6.01034.420
Outstanding separation properties and high-capacity – these are the things which clearly distinguish the Metrosep A Supp 19 product family from the rest of the column portfolio. It features best peak symmetries and selectivities as well as high thermal, mechanical and chemical stability, which makes it extremely robust and stable in the presence of higher flow rates and pressures.The 150 mm version is considered the standard column for anion chromatography, as it reliably solves the lion's share of applications and is very versatile in its use. Thanks to its high capacity, the Metrosep A Supp 19 - 150/4.0 separation column is particularly well suited even for complex applications with sophisticated matrices. The range of applications of the Metrosep A Supp 19 - 150/4.0 is very versatile, thanks to its outstanding separation properties and comprises the following applications, for example:Determination of standard anions (fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate) in a wide variety of water samples;;
Determination of standard anions and organic acids in complex sample matrices, e.g. environmental or food samples;;
Determination of standard anions and organic acids in boiler feed water to ensure the safe operation of power plants;;
Determination of standard anions in pharmaceutical samples.;
Metrosep A Supp 21 - 250/4.0
6.01036.430
The Metrosep A Supp 21 columns are designed for operation with hydroxide-based eluents and provide excellent separating efficiency, coupled with a very high capacity. The small particles (4.6 μm) based on hydrophilized polystyrene/divinylbenzene guarantee sharp peaks. The stationary phase exhibits high stability with respect to temperature, pressure, and pH value, and is therefore suitable for extreme working conditions.The longer Metrosep A Supp 21 - 250/4.0 column version was specially developed for the determination of oxohalides (chlorite, bromate, chlorate), standard anions (fluoride, chloride, nitrite, bromide, nitrate, sulfate, and phosphate), und DCAA (dichloracetate). With its separating efficiency, it exceeds the requirements of the US EPA method 300.1 A+B and of the DIN EN ISO 10304-1&4 standard. The high column capacity enables the quantification of anions and oxohalides in low μg/L concentrations with excellent reproducibility, even in the most challenging sample matrices. With the wide range of elution conditions available, it is also possible to determine other anionic components, e.g. low-molecular-weight organic acids.