948 Continuous IC Module, CEP
2.948.0010
948 Continuous IC Module, CEP
en
2.948.0010
Feature overview
Automated hydroxide eluent production takes place with the 948 Continuous IC Module. Isocratic eluents can be produced and gradients can be run.
The 948 Continuous IC Module, CEP is comprised of the following parts:
- 948 Continuous IC Module
- Eluent Producer Cartridge (EPC, 6.02850.200)
- Continuous anion trap (CT, 6.02850.100)
- High-pressure degasser (H-DEG, 6.02850.000)
Example methods according to 948 Continuous IC Module manual.
Tech specs
Eluent production specifications
Flow rate: 0.1–3.0 mL/min
Pressure: Max. 21 MPa
Concentration: 0.1–100 mmol/L, depending on the flow
Solvent: Max. 25% methanol
Eluent Producer cartridge: Refillable
Product Family
- title
- Automation for IC
- description
- Whatever the number of samples and whatever preparatory treatment, we provide automated solutions for ion chromatography to meet your requirements.
Documents
-
809488001
-
de
- title
- Handbuch 948 Continuous IC Module
- description
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/0948/809488001
-
en
- title
- Manual for 948 Continuous IC Module
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/0948/809488001
-
fr
- title
- Mode d'emploi du 948 Continuous IC Module
- description
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/0948/809488001
-
es
- title
- Manual del 948 Continuous IC Module
- description
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/0948/809488001
-
zh
- title
- 948 Continuous IC Module 手册
- description
- language
- zh
- documentpath
- /content/metrohm/shared/zh/products/8/0948/809488001
-
vi
- title
- Manual for 948 Continuous IC Module
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/0948/809488001
-
de
-
89485000
-
de
- title
- Continuous Ion Chromatography Module: Geniessen Sie die Vorteile einer automatischen Herstellung hochreiner Eluenten
- description
- Die manuelle Herstellung von Hydroxid-Eluenten kostet wertvolle Laborzeit und erfordert aufgrund der Korrosivität dieser Eluenten bestimmte Sicherheitsmassnahmen. Zudem ist die manuelle Handhabung von Chemikalien anfällig für menschliche Fehler, was sich negativ auf die Reproduzierbarkeit der Analyseresultate auswirken kann. Das Continuous IC Module ist die Lösung für diese Probleme. Die vollautomatische Herstellung von Hydroxid-Eluenten mit dem Continuous IC Module ermöglicht eine sichere Handhabung von Hydroxid-Eluenten und verbessert gleichzeitig die Reproduzierbarkeit und Genauigkeit der Resultate.
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/9485/89485000
-
en
- title
- Continuous Ion Chromatography Module: Enjoy the benefits of automatic generation of high-purity eluents
- description
- Manual preparation of hydroxide eluents costs valuable laboratory time and requires certain safety measures due to the corrosiveness of such eluents. Moreover, manual handling of chemicals is prone to human error, which can negatively impact the reproducibility of analytical results. The Continuous IC Module is the solution to these issues. Fully automated hydroxide eluent generation with the Continuous IC Module provides for safe handling of hydroxide eluents while improving reproducibility and accuracy of results.
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/9485/89485000
-
fr
- title
- Module de chromatographie ionique continue : bénéficiez d'une génération automatique d'éluants de haute pureté
- description
- La préparation manuelle des éluants d'hydroxyde coûte un temps de laboratoire précieux et requiert certaines mesures de sécurité en raison de la corrosivité de ce type d'éluants. De plus, la manipulation manuelle de produits chimiques est sujette à l'erreur humaine qui peut influencer négativement la reproductibilité des résultats analytiques. Le Continuous IC Module est la solution à ces problèmes. La génération d'éluants d'hydroxyde complètement automatisée avec le Continuous IC Module permet une manipulation en toute sécurité des éluants d'hydroxyde tout en améliorant la reproductibilité et la précision des résultats.
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/9485/89485000
-
es
- title
- Módulo de cromatografía iónica continua: disfrute de los beneficios de la generación automática de eluyentes de alta pureza
- description
- La preparación manual de eluyentes de hidróxido requiere emplear un valioso tiempo de laboratorio y tomar ciertas medidas de seguridad debido a la corrosividad de dichos eluyentes. Además, el manejo manual de productos químicos tiende a ocasionar errores humanos que pueden afectar negativamente a la reproducibilidad de los resultados analíticos. El Continuous IC Module es la solución para estos inconvenientes. La generación totalmente automatizada de eluyentes de hidróxido con el Continuous IC Module permite manejarlos con seguridad y a la vez mejora la reproducibilidad y la exactitud de los resultados.
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/9485/89485000
-
vi
- title
- Continuous Ion Chromatography Module: Enjoy the benefits of automatic generation of high-purity eluents
- description
- Manual preparation of hydroxide eluents costs valuable laboratory time and requires certain safety measures due to the corrosiveness of such eluents. Moreover, manual handling of chemicals is prone to human error, which can negatively impact the reproducibility of analytical results. The Continuous IC Module is the solution to these issues. Fully automated hydroxide eluent generation with the Continuous IC Module provides for safe handling of hydroxide eluents while improving reproducibility and accuracy of results.
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/9485/89485000
-
de
-
809483001
-
de
- title
- EU-Konformitätserklärung 948 Continuous IC Module
- description
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/0948/809483001
-
en
- title
- EU declaration of conformity for 948 Continuous IC Module
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/0948/809483001
-
fr
- title
- Déclaration UE de conformité 948 Continuous IC Module
- description
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/0948/809483001
-
ja
- title
- EU 適合宣言書 948 Continuous IC Module
- description
- language
- ja
- documentpath
- /content/metrohm/shared/ja/products/8/0948/809483001
-
es
- title
- Declaración UE de conformidad para el 948 Continuous IC Module
- description
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/0948/809483001
-
zh
- title
- 948 Continuous IC Module 欧盟一致性声明
- description
- language
- zh
- documentpath
- /content/metrohm/shared/zh/products/8/0948/809483001
-
vi
- title
- EU declaration of conformity for 948 Continuous IC Module
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/0948/809483001
-
de
-
- High-pressure degasser
- 6.02850.000
- The high-pressure degasser is responsible for the elimination of the hydrogen gas that is formed during eluent production.
- <p>The high-pressure degasser is responsible for the elimination of the hydrogen gas that is formed during eluent production.</p>
- PCS
- 1
- Continuous anion trap (CT)
- 6.02850.100
- The continuous anion trap (CT-A) removes anionic contamination and carbonate from the eluent.
- <p>The continuous anion trap (CT-A) removes anionic contamination and carbonate from the eluent.</p>
- PCS
- 1
- Eluent producer cartridge A
- 6.02850.200
- The eluent producer cartridge A (EPC A) produces the high-purity hydroxide eluent from the 4 mol/L hydroxide concentrate, based on water electrolysis. The cation exchanger diaphragm enables the selective migration of cations into the eluent. The EPC A is fed ultrapure water, which can be operated fully automatically in connection with a water processing system.
- <p>The eluent producer cartridge A (EPC A) produces the high-purity hydroxide eluent from the 4 mol/L hydroxide concentrate, based on water electrolysis. The cation exchanger diaphragm enables the selective migration of cations into the eluent. The EPC A is fed ultrapure water, which can be operated fully automatically in connection with a water processing system.<br /> </p>
- PCS
- 1
- Accessory kit: CEP
- 6.05000.300
- Accessory kit for installation of the 948 Continuous IC Module, CEP
- <p>Accessory kit for installation of the 948 Continuous IC Module, CEP</p>
- PCS
- 1
- Cable USB A - USB B 1.8 m
- 6.2151.020
- USB connecting cable
- USB connecting cable
- PCS
- 1
- Power supply unit 100 - 240 V/24 V DC
- 6.2164.010
- Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.
- <p>Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.</p>
- PCS
- 1
-
- High-pressure degasser
- 6.02850.000
- The high-pressure degasser is responsible for the elimination of the hydrogen gas that is formed during eluent production.
- <p>The high-pressure degasser is responsible for the elimination of the hydrogen gas that is formed during eluent production.</p>
- PCS
- 1
- Continuous anion trap (CT)
- 6.02850.100
- The continuous anion trap (CT-A) removes anionic contamination and carbonate from the eluent.
- <p>The continuous anion trap (CT-A) removes anionic contamination and carbonate from the eluent.</p>
- PCS
- 1
- Eluent producer cartridge A
- 6.02850.200
- The eluent producer cartridge A (EPC A) produces the high-purity hydroxide eluent from the 4 mol/L hydroxide concentrate, based on water electrolysis. The cation exchanger diaphragm enables the selective migration of cations into the eluent. The EPC A is fed ultrapure water, which can be operated fully automatically in connection with a water processing system.
- <p>The eluent producer cartridge A (EPC A) produces the high-purity hydroxide eluent from the 4 mol/L hydroxide concentrate, based on water electrolysis. The cation exchanger diaphragm enables the selective migration of cations into the eluent. The EPC A is fed ultrapure water, which can be operated fully automatically in connection with a water processing system.<br /> </p>
- PCS
- 1
- Accessory kit: CEP
- 6.05000.300
- Accessory kit for installation of the 948 Continuous IC Module, CEP
- <p>Accessory kit for installation of the 948 Continuous IC Module, CEP</p>
- PCS
- 1
- Cable USB A - USB B 1.8 m
- 6.2151.020
- USB connecting cable
- USB connecting cable
- PCS
- 1
- Power supply unit 100 - 240 V/24 V DC
- 6.2164.010
- Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.
- <p>Power supply unit for 915 KF Ti-Touch, 916 Ti-Touch, 917 Coulometer and all Eco Titrators / Eco Dosimat.</p>
- PCS
- 1
-
- Bottle PE / 1000 mL / GL 45
- 6.1608.040
- For Exchange Units. Bottle for auxiliary solutions.
- For Exchange Units. Bottle for auxiliary solutions.
- PCS
- 1
- MSM-HC Rotor A, Hydroxide
- 6.2842.100
- Suppressor rotor with high capacity for hydroxide eluents for all IC instruments with MSM-HC (Metrohm Suppressor Module with high capacity).
- <p>Suppressor rotor with high capacity for hydroxide eluents for all IC instruments with MSM-HC (Metrohm Suppressor Module with high capacity).</p>
- PCS
- 1
- Metrosep A Supp 19 - 150/4.0
- 6.01034.420
- Outstanding separation properties and high-capacity – these are the things which clearly distinguish the Metrosep A Supp 19 product family from the rest of the column portfolio. It features best peak symmetries and selectivities as well as high thermal, mechanical and chemical stability, which makes it extremely robust and stable in the presence of higher flow rates and pressures.The 150 mm version is considered the standard column for anion chromatography, as it reliably solves the lion's share of applications and is very versatile in its use. Thanks to its high capacity, the Metrosep A Supp 19 - 150/4.0 separation column is particularly well suited even for complex applications with sophisticated matrices. The range of applications of the Metrosep A Supp 19 - 150/4.0 is very versatile, thanks to its outstanding separation properties and comprises the following applications, for example:Determination of standard anions (fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate) in a wide variety of water samples;; Determination of standard anions and organic acids in complex sample matrices, e.g. environmental or food samples;; Determination of standard anions and organic acids in boiler feed water to ensure the safe operation of power plants;; Determination of standard anions in pharmaceutical samples.;
- <p>Outstanding separation properties and high-capacity – these are the things which clearly distinguish the Metrosep A Supp 19 product family from the rest of the column portfolio. It features best peak symmetries and selectivities as well as high thermal, mechanical and chemical stability, which makes it extremely robust and stable in the presence of higher flow rates and pressures.<br />The 150 mm version is considered the standard column for anion chromatography, as it reliably solves the lion's share of applications and is very versatile in its use. Thanks to its high capacity, the Metrosep A Supp 19 - 150/4.0 separation column is particularly well suited even for complex applications with sophisticated matrices. The range of applications of the Metrosep A Supp 19 - 150/4.0 is very versatile, thanks to its outstanding separation properties and comprises the following applications, for example:</p><ul><li>Determination of standard anions (fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate) in a wide variety of water samples;</li><li>Determination of standard anions and organic acids in complex sample matrices, e.g. environmental or food samples;</li><li>Determination of standard anions and organic acids in boiler feed water to ensure the safe operation of power plants;</li><li>Determination of standard anions in pharmaceutical samples.</li></ul>
- PCS
- 1
- Metrosep A Supp 21 - 250/4.0
- 6.01036.430
- The Metrosep A Supp 21 columns are designed for operation with hydroxide-based eluents and provide excellent separating efficiency, coupled with a very high capacity. The small particles (4.6 μm) based on hydrophilized polystyrene/divinylbenzene guarantee sharp peaks. The stationary phase exhibits high stability with respect to temperature, pressure, and pH value, and is therefore suitable for extreme working conditions.The longer Metrosep A Supp 21 - 250/4.0 column version was specially developed for the determination of oxohalides (chlorite, bromate, chlorate), standard anions (fluoride, chloride, nitrite, bromide, nitrate, sulfate, and phosphate), und DCAA (dichloracetate). With its separating efficiency, it exceeds the requirements of the US EPA method 300.1 A+B and of the DIN EN ISO 10304-1&4 standard. The high column capacity enables the quantification of anions and oxohalides in low μg/L concentrations with excellent reproducibility, even in the most challenging sample matrices. With the wide range of elution conditions available, it is also possible to determine other anionic components, e.g. low-molecular-weight organic acids.
- <p>The Metrosep A Supp 21 columns are designed for operation with hydroxide-based eluents and provide excellent separating efficiency, coupled with a very high capacity. The small particles (4.6 μm) based on hydrophilized polystyrene/divinylbenzene guarantee sharp peaks. The stationary phase exhibits high stability with respect to temperature, pressure, and pH value, and is therefore suitable for extreme working conditions.<br />The longer Metrosep A Supp 21 - 250/4.0 column version was specially developed for the determination of oxohalides (chlorite, bromate, chlorate), standard anions (fluoride, chloride, nitrite, bromide, nitrate, sulfate, and phosphate), und DCAA (dichloracetate). With its separating efficiency, it exceeds the requirements of the US EPA method 300.1 A+B and of the DIN EN ISO 10304-1&4 standard. The high column capacity enables the quantification of anions and oxohalides in low μg/L concentrations with excellent reproducibility, even in the most challenging sample matrices. With the wide range of elution conditions available, it is also possible to determine other anionic components, e.g. low-molecular-weight organic acids.</p>
- PCS
- 1