851 Titrando with generator electrode without diaphragm
2.851.0110
4.73
/ 5.0 26 Değerlendirmeler SelectScience üzerinde
- Genel özellikler
Coulometer including generator electrode without diaphragm.
Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.
Coulometric titrations are carried out easily and quickly with the 851 Titrando.
Recommended measuring range: 10 µg - 200 mg absolute water.
For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
Daha yakından tanıyın 851 Titrando with generator electrode without diaphragm
KF Titrando
%0,001'den %100'e kadar herhangi bir su içeriğinin doğru belirlenmesi için volumetrik ve kulometrik Karl Fischer titratörü.Neden? KF Titrando?
- İngilizceManual for 851 Titrando
Ekipmanlar Size özel 851 Titrando with generator electrode without diaphragm
Aksesuarlar PDF dosyasını indir







- Dahili parçalar
- Opsiyonel parçalar
Double Pt-wire electrode for coulometry
6.0341.100
Indicator electrode used for coulometric Karl Fischer titration.
Generator electrode without diaphragm
6.0345.100
Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.
KF adsorber tube for coulometer cell
6.1403.030
For KF coulometers.
SGJ stopper SGJ 14
6.1437.000
Daha fazlası
Adapter red 2 mm plug / 4 mm socket
6.2103.130
For connecting plug B (4 mm) to 2 mm socket.
Adapter black 2 mm plug / B socket 4 mm
6.2103.140
For connecting plug B (4 mm) to 2 mm socket.
Molecular sieve
6.2811.000
Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.
Molecular sieve (US)
6.2811.010
Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.This product is intended for all users who are US residents. The material is rated hazardous in the US in accordance with OSHA Hazard Communication Standard (29 CFR 1910.1200).
Daha fazlası
İlgili makaleler
24 May 2024
Kondüktometrik titrasyon diğer yöntemlerin zorlandığı durumlarda uygun bir alternatiftir
30 May 2022
Handheld 785 nm Raman applications: Cutting edge material ID capabilities in your pocket
2 / 2
