851 Titrando with generator electrode without diaphragm
2.851.0110
4.73
/ 5.0 26 Opiniões em SelectScience
- Visão geral
Coulometer including generator electrode without diaphragm.
Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.
Coulometric titrations are carried out easily and quickly with the 851 Titrando.
Recommended measuring range: 10 µg - 200 mg absolute water.
For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
Conheça 851 Titrando with generator electrode without diaphragm
KF Titrando
Titulador Karl Fischer volumétrico e coulométrico para determinação precisa de qualquer teor de água, de 0,001 a 100%.Porquê escolher KF Titrando?
- EnglishManual for 851 Titrando
- PortugueseDeclaration of conformity 851 Titrando
Equipamento Seu 851 Titrando with generator electrode without diaphragm
Descarregar acessórios PDF







- peças incluídas
- peças opcionais
Double Pt-wire electrode for coulometry
6.0341.100
Indicator electrode used for coulometric Karl Fischer titration.
Generator electrode without diaphragm
6.0345.100
Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.
KF adsorber tube for coulometer cell
6.1403.030
For KF coulometers.
SGJ stopper SGJ 14
6.1437.000
Mostrar mais
Adapter red 2 mm plug / 4 mm socket
6.2103.130
For connecting plug B (4 mm) to 2 mm socket.
Adapter black 2 mm plug / B socket 4 mm
6.2103.140
For connecting plug B (4 mm) to 2 mm socket.
Molecular sieve
6.2811.000
Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.
Molecular sieve (US)
6.2811.010
Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.This product is intended for all users who are US residents. The material is rated hazardous in the US in accordance with OSHA Hazard Communication Standard (29 CFR 1910.1200).
Mostrar mais
Artigos relacionados
20 de jan. de 2025
Entendendo a titulação potenciométrica: Uma técnica vital na análise farmacêutica
7 de out. de 2024
Por que controlar a temperatura para resultados NIRS mais precisos e reprodutíveis
16 de out. de 2023
Aplicação de métodos validados pela USP para equivalência de colunas de separação
2 / 2