851 Titrando with generator electrode with diaphragm
2.851.0010
4.65
/ 5.0 75 Değerlendirmeler SelectScience üzerinde
- Genel özellikler
Coulometer including generator electrode with diaphragm and 801 Magnetic Stirrer.
Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.
Coulometric titrations are carried out easily and quickly with the 851 Titrando.
Recommended measuring range: 10 µg - 200 mg absolute water
For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required
Daha yakından tanıyın 851 Titrando with generator electrode with diaphragm
KF Titrando
%0,001'den %100'e kadar herhangi bir su içeriğinin doğru belirlenmesi için volumetrik ve kulometrik Karl Fischer titratörü.Neden? KF Titrando?
Ekipmanlar Size özel 851 Titrando with generator electrode with diaphragm
Aksesuarlar PDF dosyasını indir







- Dahili parçalar
- Opsiyonel parçalar
Double Pt-wire electrode for coulometry
6.0341.100
Indicator electrode used for coulometric Karl Fischer titration.
Generator electrode with diaphragm
6.0344.100
Generator electrode with diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.This generator electrode is well suited for: samples with very low absolute water contents < 50 ppm; coulometric water content determination in oil samples; applications where ketone reagents are used; applications where low-conducting reagents are used (addition of chloroform, xylene >10%);
KF adsorber tube for coulometer cell
6.1403.030
For KF coulometers.
SGJ stopper SGJ 14
6.1437.000
Daha fazlası
Adapter red 2 mm plug / 4 mm socket
6.2103.130
For connecting plug B (4 mm) to 2 mm socket.
Adapter black 2 mm plug / B socket 4 mm
6.2103.140
For connecting plug B (4 mm) to 2 mm socket.
Molecular sieve
6.2811.000
Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.
Molecular sieve (US)
6.2811.010
Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.This product is intended for all users who are US residents. The material is rated hazardous in the US in accordance with OSHA Hazard Communication Standard (29 CFR 1910.1200).