892 Professional Rancimat
2.892.0010
- Przegląd funkcji
- Specyfikacja techniczna
The 892 Professional Rancimat is an analysis system for the simple and safe determination of the oxidation stability of natural fats and oils with the well-established Rancimat method. With eight measuring positions in two heating blocks. The built-in display shows the status of the instrument and each individual measuring position. Start buttons for every measuring position enable the measurement start on the instrument. Cleaning effort can be reduced to a minimum through the use of practical disposable reaction vessels and dishwasher-safe accessories. This saves time and costs and significantly improves accuracy and reproducibility.
All accessories necessary for carrying out determinations are included in the scope of delivery. The StabNet software is required for instrument control, data recording and evaluation and for data storage.
The 892 Professional Rancimat is an analysis system for the simple and safe determination of the oxidation stability of natural fats and oils with the well-established Rancimat method. With eight measuring positions in two heating blocks. The built-in display shows the status of the instrument and each individual measuring position. Start buttons for every measuring position enable the measurement start on the instrument. Cleaning effort can be reduced to a minimum through the use of practical disposable reaction vessels and dishwasher-safe accessories. This saves time and costs and significantly improves accuracy and reproducibility.
All accessories necessary for carrying out determinations are included in the scope of delivery. The StabNet software is required for instrument control, data recording and evaluation and for data storage.
Dowiedz się więcej: 892 Professional Rancimat
Rancimat - stabilność oksydacyjna, ocena czasu indukcji
Metoda Rancimat - to test przyśpieszonego starzenia produktów takich jak naturalnych olejów, tłuszczów, kosmetyków, biodiesla, a także polimerów zawierających chlor np. PVC. Parametrem opisującym to zjawisko jest "czas indukcji", "okres indukcji", "indeks stabilności produktu", określający czas, jaki upływa do momentu pojawienia się wtórnych produktów reakcji. Im dłuższy czas indukcji, tym próbka jest bardziej stabilna. Rancimat stosuje się do oceny czasu indukcji lub wskaźnika stabilności oksydacyjnej (OSI) żywności zawierającej tłuszcz, kosmetyków oraz naturalnych tłuszczów i olejów.Dlaczego Rancimat - stabilność oksydacyjna, ocena czasu indukcji?
- części w zestawie
- opcjonalne części
