Бяхте прехвърлени към локалната страница
i-Raman EX Portable Raman Spectrometer

i-Raman EX Portable Raman Spectrometer

BWT-840001234

Този продукт е спрян от производство, но все още се поддържа.
    • BWSpec Software
    • BWT-810000044
    • BWSpec® is B&W Tek’s general spectroscopy software for instrument control and data acquisition, including real-time peak analysis and trending. BWSpec is the operating software included with the purchase of all B&W Tek portable Raman systems and spectrometer products. It is designed with features for broad range applications, performing complex measurements and calculations at the click of a button. It supports multiple data formats and provides the option to optimize measurement parameters, such as integration time and laser output power control. In addition to data acquisition and data processing, it also offers automatic dark removal, spectral smoothing, baseline correction, as well as peak monitoring and trending. 
    • <p>BWSpec<sup>&reg;</sup> is B&amp;W Tek&rsquo;s general spectroscopy software for instrument control and data acquisition, including real-time peak analysis and trending. BWSpec is the operating software included with the purchase of all B&amp;W Tek portable Raman systems and spectrometer products. It is designed with features for broad range applications, performing complex measurements and calculations at the click of a button. It supports multiple data formats and provides the option to optimize measurement parameters, such as integration time and laser output power control. In addition to data acquisition and data processing, it also offers automatic dark removal, spectral smoothing, baseline correction, as well as peak monitoring and trending.<br /><br /><br /><br /><br />&nbsp;</p>
    • PCS
    • 1
    • Laser safety goggles (1064 nm)
    • BWT-840000102
    • Laser safety goggles for lasers with excitation at 1,064 nm – suitable for Class IIIB laser systems from B&W Tek.
    • <p>Laser safety goggles for lasers with excitation at 1,064 nm – suitable for Class IIIB laser systems from B&amp;W Tek.</p>
    • PCS
    • 1
    • Portable Raman Instrument Validation Cap
    • BWT-840000289
    • Validation Cap with integrated ASTM-standard polystyrene for use with the BAC100/BAC102 lab-grade Raman Probe with shaft diameter of 9.5 mm.
    • <p>Validation Cap with integrated ASTM-standard polystyrene for use with the BAC100/BAC102 lab-grade Raman Probe with shaft diameter of 9.5 mm.</p>
    • PCS
    • 1
    • High-Throughput Raman Trigger Probe (1064 nm)
    • BWT-840000909
    • Lab-grade fiber-optic Raman probe module for high throughput, with manual trigger, 105 µm diameter, 0.22 NA fiber for excitation at 1,064 nm , 300 µm diameter, 0.22 NA for Raman pickup, optical density > 6; up to 100 cm-1. 1.5 m long fiber cable terminated in FC/PC connector on the spectrometer end and FC/PC on the laser end. Adhesive-sealed silica window for non-contact sampling. 5.9 mm working distance. Not suitable for immersive use. For use with i-Raman EX, i-Raman Prime-1064, and as option for STRam-1064.BAC102-1064-HT
    • <p>Lab-grade fiber-optic Raman probe module for high throughput, with manual trigger, 105 &micro;m diameter, 0.22 NA fiber for excitation at 1,064 nm , 300 &micro;m diameter, 0.22 NA for Raman pickup, optical density &gt; 6; up to 100 cm<sup>-1</sup>. 1.5 m long fiber cable terminated in FC/PC connector on the spectrometer end and FC/PC on the laser end. Adhesive-sealed silica window for non-contact sampling. 5.9 mm working distance. Not suitable for immersive use. For use with i-Raman EX, i-Raman Prime-1064, and as option for STRam-1064.</p><p>BAC102-1064-HT</p>
    • PCS
    • 1
    • BWSpec Software
    • BWT-810000044
    • BWSpec® is B&W Tek’s general spectroscopy software for instrument control and data acquisition, including real-time peak analysis and trending. BWSpec is the operating software included with the purchase of all B&W Tek portable Raman systems and spectrometer products. It is designed with features for broad range applications, performing complex measurements and calculations at the click of a button. It supports multiple data formats and provides the option to optimize measurement parameters, such as integration time and laser output power control. In addition to data acquisition and data processing, it also offers automatic dark removal, spectral smoothing, baseline correction, as well as peak monitoring and trending. 
    • <p>BWSpec<sup>&reg;</sup> is B&amp;W Tek&rsquo;s general spectroscopy software for instrument control and data acquisition, including real-time peak analysis and trending. BWSpec is the operating software included with the purchase of all B&amp;W Tek portable Raman systems and spectrometer products. It is designed with features for broad range applications, performing complex measurements and calculations at the click of a button. It supports multiple data formats and provides the option to optimize measurement parameters, such as integration time and laser output power control. In addition to data acquisition and data processing, it also offers automatic dark removal, spectral smoothing, baseline correction, as well as peak monitoring and trending.<br /><br /><br /><br /><br />&nbsp;</p>
    • PCS
    • 1
    • Laser safety goggles (1064 nm)
    • BWT-840000102
    • Laser safety goggles for lasers with excitation at 1,064 nm – suitable for Class IIIB laser systems from B&W Tek.
    • <p>Laser safety goggles for lasers with excitation at 1,064 nm – suitable for Class IIIB laser systems from B&amp;W Tek.</p>
    • PCS
    • 1
    • Portable Raman Instrument Validation Cap
    • BWT-840000289
    • Validation Cap with integrated ASTM-standard polystyrene for use with the BAC100/BAC102 lab-grade Raman Probe with shaft diameter of 9.5 mm.
    • <p>Validation Cap with integrated ASTM-standard polystyrene for use with the BAC100/BAC102 lab-grade Raman Probe with shaft diameter of 9.5 mm.</p>
    • PCS
    • 1
    • High-Throughput Raman Trigger Probe (1064 nm)
    • BWT-840000909
    • Lab-grade fiber-optic Raman probe module for high throughput, with manual trigger, 105 µm diameter, 0.22 NA fiber for excitation at 1,064 nm , 300 µm diameter, 0.22 NA for Raman pickup, optical density > 6; up to 100 cm-1. 1.5 m long fiber cable terminated in FC/PC connector on the spectrometer end and FC/PC on the laser end. Adhesive-sealed silica window for non-contact sampling. 5.9 mm working distance. Not suitable for immersive use. For use with i-Raman EX, i-Raman Prime-1064, and as option for STRam-1064.BAC102-1064-HT
    • <p>Lab-grade fiber-optic Raman probe module for high throughput, with manual trigger, 105 &micro;m diameter, 0.22 NA fiber for excitation at 1,064 nm , 300 &micro;m diameter, 0.22 NA for Raman pickup, optical density &gt; 6; up to 100 cm<sup>-1</sup>. 1.5 m long fiber cable terminated in FC/PC connector on the spectrometer end and FC/PC on the laser end. Adhesive-sealed silica window for non-contact sampling. 5.9 mm working distance. Not suitable for immersive use. For use with i-Raman EX, i-Raman Prime-1064, and as option for STRam-1064.</p><p>BAC102-1064-HT</p>
    • PCS
    • 1
    • Raman Cuvette Holder for 9.5 mm measurement probe
    • BWT-810000389
    • The BCR100A Raman cuvette holder allows you to easily measure Raman spectrum of liquids and powders by attaching a Raman probe to the holder. This accessory part uses an internal mirror with a three-point precision locking mechanism for unmatched reproducibility, thereby increasing the Raman signal up to 3x higher than conventional cuvette holders. It is designed so that the probe shaft does not directly contact the cuvette and includes a light trap to reduce background fluorescence. The BCR100A is available in model versions for probes with a diameter of 9.5 mm or 12 mm and can be used with any standard cuvette of 12.5 mm x 12.5 mm outer diameter (1 cm path length) for sampling liquids or powders.
    • <p>The BCR100A Raman cuvette holder allows you to easily measure Raman spectrum of liquids and powders by attaching a Raman probe to the holder. This accessory part uses an internal mirror with a three-point precision locking mechanism for unmatched reproducibility, thereby increasing the Raman signal up to 3x higher than conventional cuvette holders. It is designed so that the probe shaft does not directly contact the cuvette and includes a light trap to reduce background fluorescence. The BCR100A is available in model versions for probes with a diameter of 9.5 mm or 12 mm and can be used with any standard cuvette of 12.5 mm x 12.5 mm outer diameter (1 cm path length) for sampling liquids or powders.</p>
    • PCS
    • 1
    • Connection cleaner
    • BWT-810000468
    • Cleaner for SMA905 and FC/PC connections.
    • <p>Cleaner for SMA905 and FC/PC connections.</p>
    • PCS
    • 1
    • Microscope head tripod adaptor
    • BWT-810000623
    • BAC151x-TRI tripod adapter for the BAC151x sampling system with Raman video microscope.
    • <p>BAC151x-TRI tripod adapter for the BAC151x sampling system with Raman video microscope.</p>
    • PCS
    • 1
    • External rechargeable battery pack for portable Raman instruments 
    • BWT-810000682
    • External Lithium-Ion battery that provides constant 12 VDC. (Compatible with the i-Raman-Plus, i-Raman Pro and i-Raman EX models).EBP106 
    • <p>External Lithium-Ion battery that provides constant 12 VDC. (Compatible with the i-Raman-Plus, i-Raman Pro and i-Raman EX models).<br /><br />EBP106<br />&nbsp;</p>
    • PCS
    • 1
    • Raman Flow Cell (BAC160-SS)
    • BWT-840000117
    • Raman flow-through cell made of stainless steel, for inline Raman measurements of liquid samples by interfacing with standard laboratory probe (9.5 mm diameter; probe is not included in scope of delivery).
    • <p>Raman flow-through cell made of stainless steel, for inline Raman measurements of liquid samples by interfacing with standard laboratory probe (9.5 mm diameter; probe is not included in scope of delivery).</p>
    • PCS
    • 1
    • BWID Standard Raman ID Software
    • BWT-840000126
    • Data acquisition, material identification and reporting software for B&W Tek portable Raman spectrometers to rapidly identify or verify materials based on user-built libraries, proprietary B&W Tek and third-party libraries. Includes system performance tests. One user license provided. Free upgrades included within one year of purchase date.
    • <p>Data acquisition, material identification and reporting software for B&amp;W Tek portable Raman spectrometers to rapidly identify or verify materials based on user-built libraries, proprietary B&amp;W Tek and third-party libraries. Includes system performance tests. One user license provided. Free upgrades included within one year of purchase date.</p>
    • PCS
    • 1
    • BWID Pharma Raman ID Software
    • BWT-840000127
    • Data acquisition and material identification software for B&W Tek portable Raman spectrometers to rapidly identify or verify materials based on user-built libraries, proprietary B&W Tek and third-party libraries. Meets all the requirements of FDA 21 CFR Part 11, including system access security, audit trail of data activities, and system performance tests. One user license provided. Free upgrades included within one year of purchase date.
    • <p>Data acquisition and material identification software for B&amp;W Tek portable Raman spectrometers to rapidly identify or verify materials based on user-built libraries, proprietary B&amp;W Tek and third-party libraries. Meets all the requirements of FDA 21 CFR Part 11, including system access security, audit trail of data activities, and system performance tests. One user license provided. Free upgrades included within one year of purchase date.</p>
    • PCS
    • 1
    • Raman Flow Cell (BAC160-Ti)
    • BWT-840000140
    • Raman flow-through cell made of titanium, for inline Raman measurements of liquid samples by interfacing with standard laboratory probe (9.5 mm diameter; probe is not included in scope of delivery).
    • <p>Raman flow-through cell made of titanium, for inline Raman measurements of liquid samples by interfacing with standard laboratory probe (9.5 mm diameter; probe is not included in scope of delivery).</p>
    • PCS
    • 1
    • GemID Software
    • BWT-840000280
    • Data acquisition and identification software for the analysis of gemstones and minerals with B&W Tek portable Raman spectrometers. Includes Raman Spectral Library and images of more than 450 gemstones from Gem Expert and Japan Germany Gemmological Laboratory. One user license provided. Free upgrades included within one year of purchase date.
    • <p>Data acquisition and identification software for the analysis of gemstones and minerals with B&amp;W Tek portable Raman spectrometers. Includes Raman Spectral Library and images of more than 450 gemstones from Gem Expert and Japan Germany Gemmological Laboratory. One user license provided. Free upgrades included within one year of purchase date.</p>
    • PCS
    • 1
    • Vial Holder Adapter
    • BWT-840000287
    • Vial holder adapter for use with the BAC100/BAC102 lab-grade Raman Probe with 9.5 mm shaft diameter. Compatible with vials with a diameter of 15 mm. Shipped with 6 vials made from borosilicate glass (15 mm).
    • <p>Vial holder adapter for use with the BAC100/BAC102 lab-grade Raman Probe with 9.5 mm shaft diameter. Compatible with vials with a diameter of 15 mm. Shipped with 6 vials made from borosilicate glass (15 mm).</p>
    • PCS
    • 1
    • Vials for liquids, 15 mm in diameter
    • BWT-840000295
    • Borosilicate glass vials (diameter 15 mm), package of 6, with pouch.
    • <p>Borosilicate glass vials (diameter 15 mm), package of 6, with pouch.</p>
    • PCS
    • 1
    • Video Microscope Objective, 10x 
    • BWT-840000322
    • Microscope objective, infinity-corrected, 10x, working distance (mm) = 16, focal length (mm) = 20, numerical aperture (NA) = 0.3.RML110A 
    • <p>Microscope objective, infinity-corrected, 10x, working distance (mm) = 16, focal length (mm) = 20, numerical aperture (NA) = 0.3.</p><p>RML110A<br />&nbsp;</p>
    • PCS
    • 1
    • Video Microscope Objective, 50x (RML150A)
    • BWT-840000325
    • Microscope objective, infinity-corrected, 50x, working distance (mm) = 9.15, focal length (mm) = 4, numerical aperture (NA) = 0.55.RML150A 
    • <p>Microscope objective, infinity-corrected, 50x, working distance (mm) = 9.15, focal length (mm) = 4, numerical aperture (NA) = 0.55.</p><p>RML150A<br />&nbsp;</p>
    • PCS
    • 1
    • Video Microscope Objective, 100x
    • BWT-840000328
    • Microscope objective, infinity-corrected, 100x, working distance (mm) = 3.2, numerical aperture (NA) = 0.8, Focal length (mm) = 2.RML1100A 
    • <p>Microscope objective, infinity-corrected, 100x, working distance (mm) = 3.2, numerical aperture (NA) = 0.8, Focal length (mm) = 2.</p><p>RML1100A<br />&nbsp;</p>
    • PCS
    • 1
    • Tablet Holder
    • BWT-840000332
    • Tablet holder compatible with all models of BAC100/BAC102 lab-grade fiber-optic Raman probe with 9.5 mm shaft diameter.
    • <p>Tablet holder compatible with all models of BAC100/BAC102 lab-grade fiber-optic Raman probe with 9.5 mm shaft diameter.</p>
    • PCS
    • 1
    • Raman Probe Holder
    • BWT-840000395
    • Probe holder for use with B&W Tek's lab-grade Raman probes. Provides manual coarse and fine XYZ adjustments.
    • <p>Probe holder for use with B&amp;W Tek's lab-grade Raman probes. Provides manual coarse and fine XYZ adjustments.</p>
    • PCS
    • 1
    • BAC151x probe adapter
    • BWT-840000463
    • BAC151x Probe Adaptor to connect B&W Tek Lab grade Raman probes to BAC151x Video microscope sampling system. Remove the standard shaft and distance regulator, to use the adaptor and connect the probe head to the video microscope. 3 adaptors per pack.
    • <p>BAC151x Probe Adaptor to connect B&amp;W Tek Lab grade Raman probes to BAC151x Video microscope sampling system. Remove the standard shaft and distance regulator, to use the adaptor and connect the probe head to the video microscope. 3 adaptors per pack.</p>
    • PCS
    • 1
    • Raman Replacement Shaft (1,064 nm)
    • BWT-840000530
    • Replacement shaft for BAC100/102-1064 Raman probe module made of standard stainless steel. Replacement shaft with adhesive-sealed fused-silica window. Working distance 5.9 mm. Shaft diameter 9.5 mm; shaft length 76.2 mm.RSS100-1064
    • <p>Replacement shaft for BAC100/102-1064 Raman probe module made of standard stainless steel. Replacement shaft with adhesive-sealed fused-silica window. Working distance 5.9 mm. Shaft diameter 9.5 mm; shaft length 76.2 mm.</p><p>RSS100-1064</p>
    • PCS
    • 1
    • Enclosure for Raman sampling system
    • BWT-840000609
    • Enclosure for Raman sampling system (i.e. microscope, probe holder) used to eliminate direct ocular and/or skin exposure from the laser emission. The enclosure is ergonomically designed to facilitate sample loading and system operation. For use with 532, 785 and 1064 nm wavelengths.
    • <p>Enclosure for Raman sampling system (i.e. microscope, probe holder) used to eliminate direct ocular and/or skin exposure from the laser emission. The enclosure is ergonomically designed to facilitate sample loading and system operation. For use with 532, 785 and 1064 nm wavelengths.</p>
    • PCS
    • 1
    • Raman Zoom Lens (20-60 mm)
    • BWT-840000711
    • Zoom lens for our BAC100/BAC102 fiber-optic Raman probes. Working distance is adjustable from 20 mm to 60 mm. Suitable for a Raman excitation range from 785 nm to 1064 nm.
    • <p>Zoom lens for our BAC100/BAC102 fiber-optic Raman probes. Working distance is adjustable from 20 mm to 60 mm. Suitable for a Raman excitation range from 785 nm to 1064 nm.</p>
    • PCS
    • 1
    • Raman Zoom Lens (60-600 mm)
    • BWT-840000712
    • Long-working-distance zoom lens for BAC100/BAC102 fiber-optic Raman probes. Working distance is adjustable from 60 mm to 600 mm. Suitable for a Raman excitation range from 1000 nm to 1100 nm.
    • <p>Long-working-distance zoom lens for BAC100/BAC102 fiber-optic Raman probes. Working distance is adjustable from 60 mm to 600 mm. Suitable for a Raman excitation range from 1000 nm to 1100 nm.</p>
    • PCS
    • 1
    • Raman Gemstone Spectral Library
    • BWT-840000843
    • Raman Gemstone Spectral Library for BWID and portable Raman instruments with > 450 spectra from Gem Expert and from Japan Germany Gemmological Laboratory. Library supported in BWID Version 2.02 or higher.
    • <p>Raman Gemstone Spectral Library for BWID and portable Raman instruments with &gt; 450 spectra from Gem Expert and from Japan Germany Gemmological Laboratory. Library supported in BWID Version 2.02 or higher.</p>
    • PCS
    • 1
    • Raman Explosives Spectral Library
    • BWT-840000847
    • Raman Explosives Spectral Library for portable Raman instruments including more than 180 spectra. Supported in BWID Version 2.02 and higher. Note: This item may be subject to Export control to some territories.
    • <p>Raman Explosives Spectral Library for portable Raman instruments including more than 180 spectra. Supported in BWID Version 2.02 and higher. <br/><br/>Note: This item may be subject to Export control to some territories.</p>
    • PCS
    • 1
    • Raman Trigger probe (1064 nm, 5 m) BAC102-1064-HT-5M
    • BWT-840000933
    • High Throughput lab-grade fiberoptic Raman probe assembly with hand trigger. 105um diameter 0.22NA fiber for 1064 nm excitation; 300um diameter 0.22NA for Raman pickup, optical density >6; down to 100 cm-1; 5.0 m fiber length terminated in FC/PC on both the spectrometer and the laser end. Adhesive sealed quartz window for non-contact sampling. 5.9 mm working distance. Not for immersive use. Includes one set of 5M Remote Interlock/Emission Indicator Plug. For use with models i-Raman EX, i-Raman Prime-1064 and STRam-1064.BAC102-1064-HT-5M
    • <p>High Throughput lab-grade fiberoptic Raman probe assembly with hand trigger. 105um diameter 0.22NA fiber for 1064 nm excitation; 300um diameter 0.22NA for Raman pickup, optical density &gt;6; down to 100 cm<sup>-1</sup>; 5.0 m fiber length terminated in FC/PC on both the spectrometer and the laser end. Adhesive sealed quartz window for non-contact sampling. 5.9 mm working distance. Not for immersive use. Includes one set of 5M Remote Interlock/Emission Indicator Plug. For use with models i-Raman EX, i-Raman Prime-1064 and STRam-1064.</p><p>BAC102-1064-HT-5M</p>
    • PCS
    • 1
    • Polystyrene Reference for STRam 
    • BWT-840000935
    • STRam probe polystyrene reference.BAC10x-ST-PCC 
    • <p>STRam probe polystyrene reference.</p><p>BAC10x-ST-PCC<br />&nbsp;</p>
    • PCS
    • 1
    • Raman Video Micro-Sampling Head (1,064 nm)
    • BWT-840000984
    • Video microscope sampling system head for use with B&W Tek's lab and industrial Raman probes. With coaxial LED illuminator for target alignment and video camera for sample observation. Compatible with standard microscope objectives. Probe not included, available separately. Objective lens not included, available separately. 1064 nm configuration.
    • <p>Video microscope sampling system head for use with B&amp;W Tek's lab and industrial Raman probes. With coaxial LED illuminator for target alignment and video camera for sample observation. Compatible with standard microscope objectives. Probe not included, available separately. Objective lens not included, available separately. 1064 nm configuration.</p>
    • PCS
    • 1
    • Raman Video Micro-Sampling System (1064 nm)
    • BWT-840000985
    • Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective at a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 1,064 nm configuration.BAC151C-1064 
    • <p>Video microscope sampling system for use with B&amp;W Tek's lab and industrial Raman probes. Includes a 20x objective at a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 1,064 nm configuration.</p><p>BAC151C-1064<br />&nbsp;</p>
    • PCS
    • 1
    • STProbe for STRam-1064 
    • BWT-840001006
    • Laboratory quality, large sampling range, fiber see-through Raman probe with hand release. 105 µm diameter 0.22 NA fiber for 1064 nm excitation; 300 µm diameter 0.22 NA fiber for Raman exposure, optical density >6; up to 100 cm-1; 1.5 m fiber length with FC/PC coupling for excitation and collection. Adhesive-sealed quartz window. Compatible with STRam-1064 and i-Raman EXII systems. Not suitable for use in liquids.BAC102-1064-ST 
    • <p>Laboratory quality, large sampling range, fiber see-through Raman probe with hand release. 105 &micro;m diameter 0.22 NA fiber for 1064 nm excitation; 300 &micro;m diameter 0.22 NA fiber for Raman exposure, optical density &gt;6; up to 100 cm-1; 1.5 m fiber length with FC/PC coupling for excitation and collection. Adhesive-sealed quartz window. Compatible with STRam-1064 and i-Raman EXII systems. Not suitable for use in liquids.<br /><br />BAC102-1064-ST<br />&nbsp;</p>
    • PCS
    • 1
    • Focus adaptor 
    • BWT-840001121
    • STRam-1064 nm focus adaptor.RST-FA-1064    
    • <p>STRam-1064 nm focus adaptor.</p><p>RST-FA-1064 <br />&nbsp;</p><p>&nbsp;</p><p>&nbsp;</p>
    • PCS
    • 1
    • Surface regulator for ST probe 
    • BWT-840001122
    • Surface regulator for ST probe.RST-SR      
    • <p>Surface regulator for ST probe.</p><p>RST-SR <br />&nbsp;</p><p>&nbsp;</p><p>&nbsp;</p><p>&nbsp;</p><p>&nbsp;</p>
    • PCS
    • 1
    • Bluetooth 1D barcode scanner
    • BWT-840001123
    • Bluetooth 1D barcode scanner for use with BWID software operating a portable Raman instrument  
    • <p>Bluetooth 1D barcode scanner for use with BWID software operating a portable Raman instrument</p><p> </p><p/><p> </p>
    • PCS
    • 1
    • Vision Pharma 4.1
    • BWT-840001136
    • Vision Pharma is data acquisition and method development software solution for spectroscopic analysis and control of B&W Tek portable Raman instruments, Metrohm XDS laboratory and process NIRS instruments. A user-friendly graphical analysis interface enables a simple application of chemometric algorithms for creating identification, qualification, and quantification methods and running them in real-time. With Vision you can store, manage, reprocess and exchange data. Vision Pharma is complies with the US FDA's 21 CFR Pt 11 regulations for electronic signatures and records.
    • <p>Vision Pharma is data acquisition and method development software solution for spectroscopic analysis and control of B&amp;W Tek portable Raman instruments, Metrohm XDS laboratory and process NIRS instruments. A user-friendly graphical analysis interface enables a simple application of chemometric algorithms for creating identification, qualification, and quantification methods and running them in real-time. With Vision you can store, manage, reprocess and exchange data. Vision Pharma is complies with the US FDA's 21 CFR Pt 11 regulations for electronic signatures and records. </p>
    • PCS
    • 1
    • Vision 4.1
    • BWT-840001137
    • Vision is data acquisition and method development software solution for spectroscopic analysis and control of B&W Tek portable Raman instruments, Metrohm XDS laboratory and process NIRS instruments. A user-friendly graphical analysis interface enables a simple application of chemometric algorithms for creating identification, qualification, and quantification methods and running them in real-time. With Vision you can store, manage, reprocess and exchange data.
    • <p>Vision is data acquisition and method development software solution for spectroscopic analysis and control of B&amp;W Tek portable Raman instruments, Metrohm XDS laboratory and process NIRS instruments. A user-friendly graphical analysis interface enables a simple application of chemometric algorithms for creating identification, qualification, and quantification methods and running them in real-time. With Vision you can store, manage, reprocess and exchange data.</p>
    • PCS
    • 1
    • Carrying Case for i-Raman Plus, i-Raman EX and GemRam systems.
    • BWT-840001178
    • Carrying Case for i-Raman, i-Raman Plus, i-Raman EX and GemRam systems. This is black soft carrying case with extendable handle, wheels and custom cut foam (27 to 28” case length) for safe, convenient instrument transport. (Model CCRM-GEMRAM)
    • <p>Carrying Case for i-Raman, i-Raman Plus, i-Raman EX and GemRam systems. This is black soft carrying case with extendable handle, wheels and custom cut foam (27 to 28&rdquo; case length) for safe, convenient instrument transport. (Model CCRM-GEMRAM)</p>
    • PCS
    • 1
    • Polystyrene validation cap for ball lens probe shaftsIMPS-PCC 
    • BWT-840001240
    • Polystyrene validation cap for system performance testing for ball lens probe shafts. Compatible with Raman fiber optic probes with a 0.5" O.D. shaft and a ball lens.IMPS-PCC 
    • <p>Polystyrene validation cap for system performance testing for ball lens probe shafts. Compatible with Raman fiber optic probes with a 0.5&quot; O.D. shaft and a ball lens.</p><p>IMPS-PCC</p><p>&nbsp;</p>
    • PCS
    • 1
    • BWID Illicit and General Chemicals Library
    • BWT-840001254
    • BWID library of illicit materials includes drugs, TICs, TIMs, precursors, and general chemicals.
    • <p>BWID library of illicit materials includes drugs, TICs, TIMs, precursors, and general chemicals.</p>
    • PCS
    • 1
    • BWID CWA Library
    • BWT-840001255
    • Raman Chemical Warfare Agent (CWA) Library for BWID.
    • <p>Raman Chemical Warfare Agent (CWA) Library for BWID.</p>
    • PCS
    • 1
    • BWID Comprehensive USP Raman Library
    • BWT-840001264
    • Metrohm Comprehensive USP Raman Library for BWID containing ~ 900 traceable certified items.
    • <p><span style="text-indent: -1.5in; background: white;">Metrohm Comprehensive USP Raman Library for BWID containing ~ 900 traceable certified items.</span></p><p class="MsoListParagraph" style="margin-left:1.5in;text-indent:-1.5in;&#10;mso-text-indent-alt:-9.0pt;mso-list:l0 level3 lfo1"><o:p></o:p></p>
    • PCS
    • 1
    • BWID Comprehensive Raman Library
    • BWT-840001265
    • BWID Metrohm Comprehensive Raman Library - More than 27,700 spectral entries of chemicals, minerals, organic chemicals, solvents, polymers, dyes and pigments, TICs, TIMs, inorganics and organometallics, personal care products, and illicit materials.PTL-MCRL
    • <p>BWID Metrohm Comprehensive Raman Library - More than 27,700 spectral entries of chemicals, minerals, organic chemicals, solvents, polymers, dyes and pigments, TICs, TIMs, inorganics and organometallics, personal care products, and illicit materials.</p><p>PTL-MCRL</p>
    • PCS
    • 1
    • BWID MCRL - Polymers and Polymer Additives
    • BWT-840001305
    • Metrohm Comprehensive Raman Library (MCRL) Polymers and Polymer Additives for BWID.
    • <p>Metrohm Comprehensive Raman Library (MCRL) Polymers and Polymer Additives for BWID.</p>
    • PCS
    • 1
    • BWID MCRL - Dyes, Pigments, and Stains
    • BWT-840001309
    • Metrohm Comprehensive Raman Library (MCRL) Dyes, Pigments, and Stains for BWID.
    • <p>Metrohm Comprehensive Raman Library (MCRL) Dyes, Pigments, and Stains for BWID.</p>
    • PCS
    • 1