요청하신 페이지의 적용되는 국가로 리디렉션되었습니다
5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 0.65 m)

5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 0.65 m)

6.00925.100

5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 0.65 m)

en

6.00925.100

기능 개요

5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.
This sensor is suitable for measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:

  • Drinking water
  • Surface water
  • Waste water

 

기술 스펙

SGJ sleeveFlexible SGJ sleeve
Shaft material (completion)PCTFE/PEEK
Shaft materialPEEK
Measuring range (theoretical)0.005...200
Measuring unitmS/cm
Temperature range, long-term (°C)0...70
Temperature range, short-term (°C)0...70
Max. installation length (mm)125
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)34
Electrode plug-in headFixed cable, plug N
Temperature sensorPt1000
Type5-ring, Pt
Cell constant, guide value (1/cm)0.7
이 필드는 필수입니다.
    • Conductivity standard 100 µS/cm 250 mL
    • 6.2324.010
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • PCS
    • 1
    • Conductivity standard 100 µS/cm, 5 x 30 mL
    • 6.2324.110
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • PCS
    • 1
    • KCl ion standard 250 mL
    • 6.2301.060
    • KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).
    • <p>KCl ion standard (c(ion) &#61; 0.1000 &#43;/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).</p>
    • PCS
    • 1
    • Measuring module conductivity
    • 6.02101.020
    • Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.
    • <p>Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.</p>
    • PCS
    • 1