Accessory Finder
BWT-840000961
Raman Video Micro-Sampling System (785 nm)Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective at a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 785 nm configuration.BAC151C-785
DRP-CAST
μStat Cable connector for Screen-Printed ElectrodesConnects any DropSens equipment with DropSens Screen-Printed Electrodes
DRP-CNFSOL-1ML
Installation Instruction for ProfIC Vario 1 AnionCarbon Nanofibres Solution produced via the catalytic carbon vapour deposition process. The manufacturing processes provide a highly graphitized material without amorphous carbon – Available in 1.0 mL and 5.0 mL.
DRP-FLWCL
Flow Cell for Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets Fittings included.
EC.Raman.Battery
Metrohm Hyphenated EC-Raman Battery SolutionAn Autolab modular PGSTAT302N with an Electrochemical Impedance Spectroscopy (EIS) module installed and a B&W Tek i-Raman Plus 532 H System are the foundation of this system. Depending on your cell size and design you can add either a B&W Tek Raman Video Micro-Sampling System (532 nm), or the B&W Tek Raman Probe Holder.Get ready to track age-induced structural changes, electrolyte decomposition, and solid electrolyte interphase (SEI) formation with your EC-Raman Battery Solution.It is easy to get started, see instant results, all with an instrument you can upgrade as your research progresses.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• An electrochemical workstation with high accuracy EIS.• Future-proof your research with the ability to add up to 7 additional modules post-installation.Choose, depending on your cell size, either a B&W Tek Raman Video Microsampling System (532 nm), or the B&W Tek Raman Probe Holder.B&W Tek Raman Video Microsampling System (532 nm) can accommodate cells up 30 mm high.B&W Tek Raman Probe Holder can accommodate large battery-dedicated EC-Raman cells.
DRP-BICAST
μStat Cable connector for Dual Screen-Printed ElectrodesConnects any DropSens equipment with DropSens Dual Screen-Printed Electrodes
DRP-CNTSOL-0.5ML
-COOH funcionalized Multi-Walled Carbon Nanotubes SolutionCarbon nanotubes are produced via CVD and purified to remove free amorphous carbon deposits and catalyst metallic particles. They are functionalized with -COOH groups - Available in 1.0 mL and 5.0 mL.
EC.Raman.Corrosion.Explorer
Metrohm Hyphenated EC-Raman Explorer Corrosion SolutionIncludes an Autolab modular PGSTAT302N with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Ready when you are, the EC-Raman Explorer Corrosion Solution is easy to use. Get started quickly with a versatile potentiostat/galvanostat that can be expanded as your research develops.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• An electrochemical workstation with high accuracy EIS.• Future-proof your research with the ability to add up to 7 additional modules post-installation.• 532 nm laser excitation for higher Raman signal• Visual surface inspection with the microsampling system
DRP-CABSTAT1
μStat 8000(P)/4000(P) one node cable connector for conventional electrodesConnects individual nodes of the μStat 8000(P)/4000(P) to conventional electrodes
DRP-FLWCL-PEEK
Flow Cell in PEEK for Screen-Printed ElectrodesPEEK wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
DRP-GPHSOL-1ML
Graphene SolutionGraphene Solution - Available in 1.0 mL and 5.0 mL.
EC.Raman.ECAT.Explorer
Metrohm Hyphenated EC-Raman Explorer Electrocatalysis SolutionIncludes an Autolab modular PGSTAT302N with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Synchronize your electrochemical measurements with in situ Raman spectroscopy providing:• Simultaneous structural and functional information about your catalysts• Operando measurements allow for tracking changes of the catalyst structure, identifying adsorbed products or intermediates• A powerful modular potentiostat/galvanostat with current ranges from 10 nA to 1 A.• An electrochemical workstation with high accuracy EIS.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• Future-proof your research with the ability to add up to 7 additional modules post-installation.• 532 nm laser excitation for higher Raman signalAll without complicated setups or complex training.
DRP-CAST8X
μStat 8000(P) cable connector for format 8X Screen-Printed ElectrodesConnects μStat 8000(P) equipment to 8X format Screen-Printed Electrodes
DRP-FLWCL-P
Flow Cell in Polypropylene for Screen-Printed ElectrodesPolypropylene wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
DRP-GPHOXSOL-1ML
Graphene Oxide SolutionGraphene Oxide Solution, based in the modification of the Hummer's Method specially designed for electrode modification providing an enhanced electrochemical active area and improved electronic transfer properties - Available in 1.0 mL and 5.0 mL.
EC.Raman.Corrosion.Starter
Metrohm Hyphenated EC-Raman Starter Corrosion SolutionIncludes a compact Autolab PGSTAT204 with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Micro-Sampling System (532 nm) and an Autolab Trigger cable.Get started quickly and have a dual perspective on corrosion phenomena. The EC-Raman Starter Corrosion Solution provides you with the instrumentation you need to get started.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• An electrochemical workstation with high accuracy EIS.• Ready-to-go and simple to use.• 532 nm laser excitation for higher Raman signal• Visual surface inspection with the microsampling system
BWT-810000682
External rechargeable battery pack for portable Raman instrumentsExternal Lithium-Ion battery that provides constant 12 VDC. (Compatible with the i-Raman-Plus, i-Raman Pro and i-Raman EX models).EBP106
DRP-CAST1X8
μStat 8000(P) cable connector for individual Screen-Printed ElectrodesConnects μStat 8000(P) equipment with individual Screen-Printed Electrodes
DRP-FLWCL-SC
Flow Cell with screws for Screen-Printed ElectrodesMethacrylate (top part) wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with screws. Fittings included.
DRP-GPHOXSOL-AQU-1ML
Graphene Oxide Solution-AqueousAqueous Aqueous graphene Oxide Solution, based in the modification of the Hummer's Method specially designed for electrode modification providing an enhanced electrochemical active area and improved electronic transfer properties.- Available in 1.0 mL and 5.0 mL.
EC.Raman.ECAT.Starter
Metrohm Hyphenated EC-Raman Starter Electrocatalysis SolutionIncludes a compact Autolab PGSTAT204 with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Discover simultaneous structural and functional information about your catalysts quickly without complicated setups or worries about synchronizing measurements. This is all possible with the EC-Raman Starter Solution.• An electrochemical workstation with high accuracy EIS.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• Measurements are automatically synchronized.• 532 nm laser excitation for higher Raman signal.
BWT-840000962
Raman Video Micro-Sampling System (532 nm)Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective with a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 532 nm configuration.BAC151C-532
DRP-CABSTATMULTI
μStat 8000(P)/4000(P) multichannel cable connector for conventional electrodesConnects the multichannel option of the μStat 8000(P)/4000(P) to up to 8/4 conventional WE sharing one conventional AUX and one conventional REF
DRP-CAC
Cable connector for Screen-Printed ElectrodesConnects DropSens Screen-Printed Electrodes to any kind of potentiostat. Recommended when working in batch or flow analysis.
DRP-FLWCL-IDE
Flow Cell for Interdigitated ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5, G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
DRP-MCSOL-1ML
Mesoporous Carbon SolutionMesoporous Carbon Solution is a homogeneous, black solution with a high purity of mesoporous carbon nanopowder.- Available in 1.0 mL and 5.0 mL
BWT-840000963
Raman Video Micro-Sampling System (532/785 nm dual)Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective at a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. Dual 532/785 nm configuration.BAC151C-532/785
DRP-BICAC
Cable connector for Dual Screen-Printed ElectrodesConnects DropSens Dual Screen-Printed Electrodes to any kind of potentiostat. Recommended when working in batch or flow analysis.
DRP-FLWCL-IDE-TEF
Flow Cell in Teflon for Interdigitated ElectrodesTeflon wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5, G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
DRP-GPHOX-0.1G
Graphene OxideGraphene oxide prepared by a modification of the Hummer's method. This yields a material with a significant number of oxygen-containing functional groups which assures homogeneous colloidal suspensions in polar solvents without addition of any surfactant. - Available in 0.1 gr and 1.0 gr.
BWT-840000985
Raman Video Micro-Sampling System (1064 nm)Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective at a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 1,064 nm configuration.BAC151C-1064
DRP-CAC-P
Cable connector for Screen-Printed Electrodes/Plastic SubstrateConnects DropSens Screen-Printed Electrodes over Plastic Substrate with any kind of potentiostat
DRP-FLWCL-WS
Flow Cell for Work in Solution Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with work in solution format Screen-Printed Electrodes with the electrochemical cell at the end of the strip. Closing system with powerful magnets. Fittings included.
DRP-MWCNT
Multi-Walled Carbon NanotubesMulti-Walled Carbon Nanotubes grown by CVD process purified to more than 95%.
DRP-CACIDE
Cable connector for Interdigitated Electrodes/Glass SubstrateConnects DropSens Interdigitated Electrodes over Glass Substrate with any kind of potentiostat
DRP-CFLWCL-WE
Flow Cell - Only Working ElectrodeMethacrylate wall-jet Flow-Cell for FIA.Its o-ring entraps only the working electrode. Suitable to be used with standard Screen-Printed Electrodes with the electrochemical cell in the center of the strip. Closing system with powerful magnets. Fittings included.
DRP-MWCNTCOOH
-COOH functionalized Multi-Walled Carbon Nanotubes-COOH functionalized Multi-Walled Carbon Nanotubes (approx. 5% functionalisation) grown by CVD process purified to more than 95%.
DRP-CACIDE-P
Cable connector for Interdigitated Electrodes/Plastic SubstrateConnects DropSens Interdigitated Electrodes over Plastic Substrate with any kind of potentiostat
DRP-CFLWCL-WE-TEF
Flow Cell in Teflon - Only Working ElectrodeTeflon wall-jet Flow-Cell for FIA.Its o-ring entraps only the working electrode. Suitable to be used with standard Screen-Printed Electrodes with the electrochemical cell in the center of the strip. Closing system with powerful magnets. Fittings included.
DRP-CAC8X
Cable connector for format 8X Screen-Printed ElectrodesConnects DropSens 8X format Screen-Printed Electrodes with any kind of (multi) potentiostat
DRP-CFLWCL-MAGN
Flow Cell for magnetic assays with Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell associated with a powered magnet designed to do FIA with magnetic beads. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Fittings included.
DRP-AUNP-COL
Colloidal Gold Nanoparticles SolutionColloidal Gold Nanoparticles Solution produced through colloidal synthesis methods, reducing a metal salt precursor in a solution and with the present of a stabilizer agent. Colloidal nanospheres Nanoparticles can be later purified and concentrated removing any stabilizing agent. Available in 25 mL.
DRP-DSC
Connector for Screen-Printed ElectrodesConnector suitable to connect DropSens SPEs to any kind of potentiostat. Recommended when working by placing a drop over the electrode
DRP-FLWCL8X
Flow Cell for 8X format Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for performing simultaneus measuements in FIA. Suitable to be used with 8X format Screen-Printed Electrodes. Closing system with screws. Fittings included.
DRP-AUNP-PUR
Purified Gold Nanoparticles SolutionColloidal Gold Nanoparticles Solution produced through colloidal synthesis methods, reducing a metal salt precursor in a solution and with the present of a stabilizer agent. Colloidal nanospheres Nanoparticles can be later purified and concentrated removing any stabilizing agent - Available in 1.0 mL.
DRP-BIDSC
Connector for Dual Screen-Printed ElectrodesConnector suitable to connect DropSens Dual SPEs to any kind of potentiostat. Recommended when working by placing a drop over the electrode
DRP-FLWCL8X1C
Flow Cell for 8X format Screen-Printed Electrodes 1 ChannelMethacrylate thin-layer Flow-Cell for performing simultaneus measuements in FIA. Suitable to be used with 8X format Screen-Printed Electrodes. Closing system with screws. Fittings included.
DRP-CFLWCL-CONIC
Cell for Screen-Printed Electrodes - Conical WellMethacrylate conic cell suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
DRP-DSC-P
Connector for plastic substrate Screen-Printed ElectrodesConnector suitable to connect DropSens plastic substrate SPEs to any kind of potentiostat. Recommended when working by placing a drop over the electrode
DRP-PDNP-COL
Colloidal Palladium Nanoparticles SolutionPalladium Nanoparticles are produced through colloidal synthesis methods, reducing a metal salt precursor in a solution and with the present of a stabilizer agent. Colloidal nanospheres Nanoparticles can be later purified and concentrated removing any stabilizing agent - Available in 25 mL.
DRP-CFLWCL-CONIC-TEF
Cell in Teflon for Screen-Printed Electrodes - Conical WellTeflon conic cell suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
DRP-CONNECT4W
Connector for 4W format Screen-Printed ElectrodesSuitable to connect 4W format Screen-Printed Electrodes to any kind of potentiostat
DRP-PDNP-PUR
Purified Palladium Nanoparticles SolutionPalladium Nanoparticles are produced through colloidal synthesis methods, reducing a metal salt precursor in a solution and with the present of a stabilizer agent. Colloidal nanospheres Nanoparticles can be later purified and concentrated removing any stabilizing agent - Available in 1.0 mL.
DRP-CONNECT8W
Connector for 8W format Screen-Printed ElectrodeSuitable to connect 8W format Screen-Printed Electrodes to any kind of potentiostat
DRP-HPLCELL
HPLC Cell for Screen-Printed ElectrodesCell in PEEK designed for working in High-Performance Liquid Chromatography systems. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip.
DRP-PTNP-COL
Colloidal Platinum Nanoparticles SolutionPlatinum Nanoparticles are produced through colloidal synthesis methods, reducing a metal salt precursor in a solution and with the present of a stabilizer agent. Colloidal nanospheres Nanoparticles can be later purified and concentrated removing any stabilizing agent - Available in 25 mL.
DRP-CELL
Cell for Screen-Printed ElectrodesCell in methacrylatel for batch analysis which allows optional stirring and it's recommended for deaerated samples and for standard additions mode. Suitable for working with all catalogue Screen-Printed Electrodes but recommended to be used with work in solution format SPEs.
DRP-CONNECTOR96X
Connects 96X format Screen-Printed Electrodes with any kind of (multi) potentiostat.Connects 96X format Screen-Printed Electrodes with any kind of (multi) potentiostat. Two manual rotating selectors allow to select the row letter (from A to H) and the column number (from 1 to 12) identifiers of the wells to be analysed.
DRP-PTNP-PUR
Purified Platinum Nanoparticles SolutionPlatinum Nanoparticles are produced through colloidal synthesis methods, reducing a metal salt precursor in a solution and with the present of a stabilizer agent. Colloidal nanospheres Nanoparticles can be later purified and concentrated removing any stabilizing agent - Available in 1.0 mL.
DRP-CAC-TLFCL
Cable connector for Thin-Layer Flow-Cell integrated Screen-Printed ElectrodesConnects DropSens Thin-Layer Flow-Cell integrated Screen-Printed Electrodes with any kind of potentiostat
DRP-TCELL
Thermostatic Cell for Screen-Printed ElectrodesMethacrylate Cell designed to perform batch analysis allowing temperature control through a thermostatic jacket. Suitable for working with all catalogue Screen-Printed Electrodes but recommended to be used with work in solution format SPEs.
DRP-AGNW-1.5ML
Silver NanowiresSilver Nanowires produced via the electrochemical deposition in an alumina template. Our Silver Nanowires have an average diameter of 150-250 nm and an average length varying in two ranges: 6-9 µm or 12-18 µm. - Available 1.5 mL and 4.5 mL.
DRP-FIAEC
Complete FIA System for Electrochemical detection with Screen-Printed ElectrodesComplete FIA System for Electrochemical detection with Screen-Printed Electrodes. Includes: VALVE, PPUMP, FLWCL, PVCTUBE, FLOWFITTINGS, Tubes and Containers
DRP-TLFCL-HOLDER
Holder for Thin-Layer Flow-Cell integrated Screen-Printed ElectrodesHolder for Thin-Layer Flow-Cell integrated Screen-Printed Electrodes
DRP-TRANSCELL
Transmission Cell for Transparent Screen-Printed ElectrodesCell in Teflon suitable to perform transmission experiments with transparent Screen-Printed Electrodes in combination with a collimator lens (ref. CLENS).
DRP-AUNW-1.5ML
Gold NanowiresGold Nanowires produced via the electrochemical deposition in an alumina template. Our Gold Nanowires have an average diameter of 150-250 nm and an average length varying in two ranges: 2- 6 µ m or 12-18 µm. - Available in 1.5 mL and 4.5 mL.
DRP-PPUMP
Peristaltic Pump4 Channel Peristaltic Pump to be used in FIA Systems
DRP-REFLECELL
Reflection Cell for Screen-Printed ElectrodesCell in Teflon suitable to perform reflection experiments with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
DRP-TLFCL-INLINEPORT
In-line LUER injection port for TLFCL SPEsIn-line LUER injection port for TLFCL format SPEs. Suitable to proceed with sample injections in flow analysis
DRP-BIASPE02
Batch Injection Analysis Cell for Screen-Printed Electrodes (Micropipette P200M)Batch Injection Analysis (BIA) cell made in ABS designed to obtain reproducible flow rate and electronically control the injection volume with a programmable electronic micropipette of 20-200 µL. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
DRP-NINW-1.5ML
Nickel NanowiresNickel Nanowires produced via the electrochemical deposition in an alumina template. This magnetic Nickel Nanowires have an average diameter of 150-250 nm and an average length that can be tuned from 6 to 8 µm. - Available in 1.5 mL and 4.5 mL.
DRP-TLFCL-FLOWFITTIN
Flow-Fitting pack for TLFCL SPEsFlow-Fitting pack for TLFCL SPEs to connect them to a FIA System. Includes: 2 male luers, 1 fitting and 30 cm of tubing
DRP-VALVE
Manual Sample Injection ValveManual Sample Injection Valve. Includes 0.5, 1.0 and 2.5 mL sample loops
DRP-BIASPE10
Batch Injection Analysis Cell for Screen-Printed Electrodes (Micropipette P1000M) in ABSBatch Injection Analysis (BIA) cell made in ABS designed to obtain reproducible flow rate and electronically control the injection volume with a programmable electronic micropipette of 100-1000 µL. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
DRP-FLOWFITTINGS
Flow-Fittings PackFlow-Fittings Pack. Includes: 2 nuts for grippers, 2 grippers and 80 cm of tubbing 1/16. Suitable to be used with our variety of Flow-Cells
DRP-MAGNETOEC
MagnetoElectroChemistry supportMagnetoElectroChemistry support with variable magnet pole gaps that allows performing magnetoelectrochemical experiments with Screen-Printed Electrodes and also with conventional electrochemical cells.
DRP-PDNW-1.5ML
Palladium NanowiresPalladium Nanowires produced via the electrochemical deposition on an alumina template. Our Palladium Nanowires have an average diameter of 150-250 nm and an average length of 10-16 µm.- Available in 1.5 mL and 4.5 mL.
DRP-MAGNET
Magnetic support for Screen-Printed ElectrodesMagnetic support for Screen-Printed Electrodes. Recommended to perform analysis with magnetic beads
DRP-PTNW-1.5ML
Platinum NanowiresPlatinum Nanowires produced via the electrochemical deposition on an alumina template. Our Platinum Nanowires have an average diameter of 150-250 nm and an average length of 10-16 µm. - Available 1.5 and 4.5 mL.
DRP-PVCTUBE-U12
PVC Tube for Peristaltic Pump - Several DiametersPVC Tube for Peristaltic Pump - Several Diameters. Includes: 3 tubes of 0.899 inner diameter, 1.143 mm inner diameter, 1.422 mm inner diameter and 1.651 mm inner diameter
DRP-RAMANCELL
Raman Cell for Screen-Printed ElectrodesBlack teflon reflection cell for performing Raman Spectroelectrochemistry with screen-printed electrodes in combination with ref. RAMANPROBE.
DRP-MAGNET8X
Magnetic support for format 8X Screen-Printed ElectrodesMagnetic support for format 8X Screen-Printed Electrodes. Recommended to perform analysis with magnetic beads
DRP-TFIBER-VIS-UV
Transmission fiber VIS-UVTransmission fiber VIS-UV designed to perform transmission experiments suitable to work with our Transmission Cell for transparent Screen-printed electrodes or with any conventional cell
DRP-TLFCL-REFLECELL
Spectroelectrochemical Reflection Cell for Thin-Layer Flow-Cell Screen-Printed ElectrodesCell for performing spectroelectrochemical measurements in flow conditions in combination with the TLFCL-CIR format Screen-Printed Electrodes, the suitable fittings and ref. RPROBE-VIS-UV.
DRP-CELL-PEEK
Cell for Screen-Printed Electrodes in PEEKCell in PEEK for batch analysis which allows optional stirring and it's recommended for deaerated samples and for standard additions mode. Suitable for working with all catalogue Screen-Printed Electrodes but recommended to be used with work in solution format SPEs.
DRP-MAGNET96X
Magnetic support for format 96X Screen-Printed ElectrodesMagnetic support for format 96X Screen-Printed Electrodes. Recommended to perform analysis with magnetic beads
DRP-NINW-STR
Streptavidin modified Nickel NanowiresStreptavidin-modified nickel nanowires are an excellent option for the immobilization of a large amount of biotinylated molecules being the perfect candidate to be use in magnet-based (bio)assays - Available in 200 μL.
DRP-RPROBE-VIS-UV
Reflection probe VIS-UVReflection probe VIS-UV designed to perform reflection experiments suitable to work with our Reflection Cell for our Screen-printed electrodes or with any conventional cell.
DRP-CLENS
Collimator LensCollimator lens suitable to work with our Transmission Cell for transparent Screen-printed electrodes or with any conventional cell.
DRP-MEMB-U100
Membrane for Screen-Printed ElectrodesMembrane for Screen-Printed Electrodes. Useful to perform analysis with small volumes of solution or sample (7,5-15 µL), allowing a good covering of the 3 electrodes system
DRP-QDCORE550
CdSe Core Quantum Dots 550 nmCore CdSe are produced via chemical synthesis at high temperature in organic solvent (chloroform).QDCORE-550: em = 550 nm; concentration= 21 ± 2μM; diameter Ø= 2.52 ± 0.03 nm - Available in 10 mL.
DRP-QDCORE570
CdSe Core Quantum Dots 570 nmCore CdSe are produced via chemical synthesis at high temperature in organic solvent (chloroform) - QDCORE-570: em = 570 nm; concentration= 23 ± 2μM; diameter Ø= 3.02 ± 0.01 nm - Available in 10 mL.
DRP-TRANSPACK
Pack for transmission experiments with SPEsTransmission pack to perfrom reflection experiments with SPEs:Includes: 1 x TRANSCELL, 1 x CLENS, 1 x TFIBER, 1 x RPROBE and 1 x CAST
DRP-QDCORE585
CdSe Core Quantum Dots 585 nmCore CdSe are produced via chemical synthesis at high temperature in organic solvent (chloroform). QDCORE-585: em = 585 nm; concentration= 24 ± 2μM; diameter Ø= 3.18 ± 0.05 nm - Available in 10 mL.
DRP-REFLEPACK
Pack for reflection experiments with SPEsReflection pack to perfrom reflection experiments with SPEs: Includes: 1 x REFLECEL, 1 x RPROBE and 1 x CAST
DRP-QDCORESHELL595
CdSe/ZnS Core/Shell Quantum Dots 595 nmCore/shell CdSe/ZnS are produced via chemical synthesis at high temperature in organic solvent. QDCORESHELL-595: em = 595 nm; concentration= 24 ± 2μM; diameter Ø= 3.21 ± 0.05 nm - Available in 10 mL.
DRP-RAMANPROBE
Raman ProbeReflection probe designed to be used with a single excitation 785 nm wavelength (up to 500 mW). Suitable to work with DropSens Raman Cell for Screen-Printed Electrodes or with any conventional Raman set-up.
DRP-CUV
Cuvette HolderThree-way cuvette holder for cuvettes up to one centimeter in length. It is designed for absorbance and fluorescence measurements with liquid samples. Includes three collimating lenses for straight-through (absorbance) or 90° (fluorescence) measurements and fiberoptic connections at each of three collimating lenses. This collimating lenses couple to optical fibers to illuminate,excite or read the sample such as ref. TFIBER-VIS-UVAdditional information:· Pathlength 1 cm· Z-dimension 15mm· Filter slot Accepts filters up to 6.35 mm (1/4”) thickness· Collimating lenses 3 x 74-UV fused silica lenses (200-2000 nm)· Fiber optic termination SMA 905
DRP-QDCORESHELL610
CdSe/ZnS Core/Shell Quantum Dots 610 nmCore/shell CdSe/ZnS are produced via chemical synthesis at high temperature in organic solvent.QDCORESHELL-610: em = 610 nm; concentration= 19 ± 3μM; diameter Ø= 3.92 ± 0.03 nm - Available in 10 mL.
DRP-CELLHOLDER
Cell HolderAccessory to be used in combination with CELL and CELL-PEEK when working in batch analysis for set up improvement.
DRP-QDCORESHELL620
CdSe/ZnS Core/Shell Quantum Dots 620 nmCore/shell CdSe/ZnS are produced via chemical synthesis at high temperature in organic solvent. QDCORESHELL-620: em = 620 nm; concentration= 20 ± 2μM; diameter Ø= 4.21 ± 0.02 nm - Available in 10 mL.
DRP-QDCORESHELL585AQ
CdSe/ZnS Core/Shell Quantum Dots 585 nm-AqueousCdSe/ZnS aqueous soluble Quantum Dots (QDs). These aqueous soluble fluorescent nanocrystals present carboxyl groups in the free end which makes them very interesting nanoparticles for conjugation procedures. QDCORESHELL-585-AQU: em= 585 nm ; concentration= 3.5 ± 0.1 μM; diameter Ø= 3.0 ± 0.15 nm - Available in 1 mL.
DRP-QDCORESHELL615AQ
CdSe/ZnS Core/Shell Quantum Dots 615 nm-AqueousCdSe/ZnS aqueous soluble Quantum Dots (QDs). These aqueous soluble fluorescent nanocrystals present carboxyl groups in the free end which makes them very interesting nanoparticles for conjugation procedures. QDCORESHELL-615-AQU: em= 615 nm ; concentration= 4.0 ± 0.2 μM; diameter Ø= 4.5 ± 0.2 nm - Available in 1 mL
DRP-QDCORESH575STRAQ
CdSe/ZnS Core/Shell Quantum Dots 575 nm modified with Streptavidin-AqueousCdSe/ZnS Core/Shell Quantum Dots 575 nm modified with Streptavidin-Aqueous are fluorescent nanoparticles (?emission maximum of ~ 575 nm), covalently functionalized with biotin-binding proteins - Available in 50 μL.
DRP-PAPP-0.25G
p-AminoPhenyl Phosphatep-AminoPhenyl Phosphate is a substrate of Alkaline Phosphatase that generates electrochemically active p-aminophenol as the product after its hydrolysis. Available in 250 mg, 500 mg, 750 mg, and 1000 mg.
DRP-HQDP-0.5G
Hydroquinone DiphosphateHydroquinone Diphosphate is a substrate of Alkaline Phosphatase that generates electrochemically active hydroquinone as the product after its hydrolysis - Available in 500 mg and 1 gr
DRP-PPAR-0.5G
Phosphorilated ParacetamolPhosphorilated Paracetamol is a substrate of Alkaline Phosphatase that generates electrochemically active Paracetamol as the product after its hydrolysis - Available in 500 mg and 1 gr.
6.1011.137
Spare filters for RP 2 Guard/3.5, 5 pcs.6.7301.000
Combustion tube (AJ)Quartz combustion tube for the Combustion Module.
6.7301.100
Guide tubing for ABD (old)Guide tubing for Automatic Boat Driver of the Combustion Module (up to ABD serial number 1709 590).
6.7301.110
Hook for ABDQuartz glass hook for quartz glass boat in the Automatic Boat Driver of the Combustion Module.
6.7302.100
Quartz boat 40 x 9 mm (AJ)Quartz glass boat for sample injection in Combustion Module, 10 pcs.
6.7302.130
Ceramic boat 40 x 9 mm (AJ)Ceramic boat for sample injection in Combustion Module, 10 pcs.
6.7303.100
Glass vial, 1.5 mL, 100 piecesFor use with the following sample changers: Liquid Autosampler CIC (TEI), MMS 5000 Autosampler (AJ) and 889 Sample Center.
6.7303.110
Septum for 67303100, 100 piecesFor use with the 67303100 Glass vial on the following sample changers: Liquid Autosampler CIC (TEI), MMS 5000 Autosampler (AJ), and 889 Sample Center.
6.7302.110
Quartz vial, 6 x 18 mm, for CIC, 50 pcs.Sample vials made of quartz for Combustion IC. The sample vials are used when the sample contains alkali and/or alkaline earth cations which could affect the quartz combustion tube. These cations reaction with the quartz in the sample vial and are thus kept away from the combustion tube. Quartz wool (6.7302.120) is used to fix the samples in place in the sample vials.
6.7302.120
Quartz wool for 6.7302.110, 10 gQuartz wool for fixing the sample in place in the sample vial made of quartz (6.7302.110).
6.7301.150
Substrate made of quartz for liquid samplesSubstrate for liquid sample injections, 3 pcs.
6.7305.040
0.5 µm filter for LPG filter unit0.5 µm particle filter on the LPG connector.
6.7305.060
40 µm filter for GSS filter unit40 µm particle filter for the GSS Module
6.7301.140
Septum 12.5 mmSeptum for liquid sample port, 5 pcs.
6.7303.240
Septum for rinsing vesselSeptum for rinsing vessel in the liquids kit for MMS 5000
6.7303.250
Septum to waste vesselSeptum to waste vessel in the MMS 5000 (2.136.0800).
6.7301.260
O-rings for CIC rinsing vesselReplacement O-rings for the Combustion IC rinsing vessel, 3 pcs.
6.7301.210
T connector CICT connector after on the outlet of the oven for supplying absorption solution.
6.7301.220
Spring wire clamp 7.3 - 7.8 mmSpring wire clamp for Fast connector
6.7304.000
FAST connector, angledFor connections with the quartz glass tubing
6.7304.010
FAST connector, straightFor connections with the quartz glass tubing
6.7301.160
Manual dosing syringe 100 µLManual dosing syringe for manual liquid sample injection
6.7303.200
50 µL syringe with replaceable needleReplacement syringe for MMS 5000 liquid setup
6.7303.210
100 µL syringe with replaceable needleReplacement syringe for MMS 5000 liquid setup
6.7303.220
Needles for 50 µL/100 µL syringes, 3 pcs.Replacement needle for syringe for MMS 5000 liquid setup
6.7301.230
Non-return tubing Combustion ICNon-return tubing for the protection of the gas box
6.7305.020
Septum perforated for PEEK gas inlet tubeSeptum perforated for transfer of the measuring gas via ABD lock.
6.7305.030
PEEK gas inlet tube for GSS/LPGFlexible tube made of PEEK guided through 6.730.5020 perforated septum.
6.7301.170
O-ring 14 × 4 mm for ABDSealing ring for connection between ABD and quartz glass tubing
6.7301.190
Sluice seal for ABDSeal for the sluice on the Automatic Boat Driver.
6.7301.240
Threader 1/16 in. Tubing Combustion ICThreader for capillaries in the FAST connector
6.7301.250
Flame sensorFlame sensor for fully automatic sample combustion
001RDX
Optical fiber spectro-electrochemical flow cell setupThis is a horizontally mounted, multi-purpose spectroelectrochemical cell designed to be coupled with light sources and spectrometers (UV-Vis, NIR, IR) via optical fibers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin films in systems where variations in applied potential induce changes in observed spectra.Applied collimating lenses are curved optical lenses that enables parallel irradiation of the sample. Each lens is 5 mm in diameter, has focal length of 10 mm and wavelength range of 200-2000 nm. The cell consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods.The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode either in the form of a rod or helix with 6 mm in diameter and 15 mm active length.Please note: this product is not available from Metrohm Germany.
002RDX
Gas Diffusion Electrode X-Ray diffraction electrochemical flow cell setupThis is a horizontally mounted, multi-purpose electrochemical cell for Gas Diffusion Electrode (GDE), designed to be used with X-Ray Diffractometry.The cell consists of two individual compartments: the liquid flow chamber and the gas chamber, which are placed on opposing faces of a GDE. Both compartments are held in place by magnetic/screw mount, providing a leakage-free O-Ring seal.The liquid chamber can be filled with an electrolyte using a syringe or an electrolyte can continuously flow through it using an external reservoir and peristaltic pump (reservoir and pump not included).The dry chamber is gas-tight enabling continuous flow of a gas carrier and evacuation of the gas products for sampling using standard analytical instruments such as a residual gas analyzer. Both compartments are made of a polyether ether ketone (PEEK) material. The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode in the form of a rod/helix with 6 mm in diameter and 15 mm active.Please note: this product is not available from Metrohm Germany.
003RDX
Spectro-electrochemical flow cell setup with reduced optical pathThis is a horizontally mounted, multi-purpose spectroelectrochemical cell with 4 mm long optical path (i.e. electrolyte thickness) designed to be used with standard UV-Vis or IR spectrometers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin film in systems where variations in applied potential induce changes in observed spectra.It consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.Unlike Spectro-EFC 1.75 mL, this cell is meant to be used with pseudo-reference electrode (50 mm long) and counter electrode in the form of a metal wire (90 mm long), both with plug of 6 mm in diameter. Thanks to the application of pseudo-reference electrode, the thickness of an electrolyte is reduced from 12 mm down to 4 mm. Please note: this product is not available from Metrohm Germany.
004RDX
Photo-electrochemical single-sided cell setupThis is a horizontally mounted, single compartment photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g.nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass).The cathode (counter electrode) and reference electrode are mounted in a top casing. The cell elements are made of PEEK. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight having gas inlet and outlet, which can be used to bubble the solution and evacuate gases from the chamber.Please note: this product is not available from Metrohm Germany.
005RDX
Small etch cell setupOne of the most common application of an electrochemical etching cell is a preparation of Nanocrystalline Porous Silicon Layer on a single crystal Si wafer. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.Please note: this product is not available from Metrohm Germany.
006RDX
Photo-electrochemical H-cell setupThis is a horizontally mounted, double compartment photo-electrochemical H-Cell used to simultaneously investigate thin film photo-anodes and cathodes. The cell elements are made of PEEK. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.The construction is gas-tight having two separate chambers, each equipped with gas inlet and outlet. This allows bubbling the solution and evacuating gases. Chambers are separated with an ion-exchange membrane (e.g. DuPont’s Nafion® membrane), so the electrochemial products appearing at photo-anode and cathode do not affect the opposite electrode.Please note: this product is not available from Metrohm Germany.
007RDX
Bulk electrolysis basic cell set upThis is a standard bulk electrolysis cell with basic configuration (known also as potentiostatic coulometry cell or controlled potential coulometry cell). The cell consists of three electrodes: working electrode (reticulated glassy carbon electrode), counter electrodes (Platinum wire) and reference electrode (aqueous Ag/AgCl or non-aqueous Ag/AgCl). The working and counter electrode are installed in the same compartment, while the reference electrode is separated by a ceramic frit.Reticulated glassy (vitreous) carbon electrode provides a large surface area to solution volume ratio. Electrode arrangement and possibility to use magnetic stirring ensure very efficient mass transport conditions. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight.Please note: this product is not available from Metrohm Germany.
008RDX
Basic electrochemical cell set upThis is a stationary solution basic electrochemical cell for measurements of electrodes in a form of:rod/disc (6 mm dia.); thin film deposited on flat substrate (using a wireclip) ; membrane (using a wire clip); The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous(EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.Please note: this product is not available from Metrohm Germany.
009RDX
Bottom mount electrochemical cell set upThis is a stationary solution voltammetry cell for measurements of a thin film deposited on flat substrate. The sample is loaded from the bottom via magnetic (or screw) mount, while counter or/and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup).The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. Please note: this product is not available from Metrohm Germany.
010RDX
Electrolyte-gated transistor bottom mounted electrochemical cell setupThis is a stationary solution electrochemical cell designed to measure characteristics of electrolyte-gated (or solution-gated) transistors using liquid or gel electrolyte. Measured transistor sample can be fabricated on a rigid or flexible flat substrate (not included in the setup) with conducting thin film source and drain, and a layer of conducting or semiconducting channel material.The sample is loaded from the bottom via magnetic (or screw) mount, while gate is mounted in a top casing. A reference electrode can also be mounted in the top casing in case it is needed to control the channel/electrolyte interfacial potential or perform an electrochemical pre-treatment on the channel material. Source and drain electrodes can be accessed through cut-outs in a cell bottom casing, using needle probes or toothless crocodile clips.The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.Please note: this product is not available from Metrohm Germany.
011RDX
Corrosion cellThis is a stationary solution corrosion cell for EIS and conventional electrochemical measurements on: (a) thin metal film deposited on flat substrate(b) metal plate(c) metal mesh(d) metal wire(e) metal ribbonThe sample is installed from the bottom via magnetic (or screw) mount in between two chambers filled with electrolyte. In cases (a) and (b) bottom chamber is unused and stays dry.The counter or/and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup). The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.Please note: this product is not available from Metrohm Germany.
012RDX
Multiport photo-electrochemical single-sided cell setupThis is a horizontally mounted, single compartment multiport photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass).The cathode (counter electrode) and reference electrode are typically mounted in a top lid, while both side lids can be used to mount up to 4 additional electrodes (e.g. pH meter, thermometer, Clark electrode, etc.). The tubing installed in side lids enables aliquot sample collection (liquid) and supply of gaseous and liquid reagents.The gas inlet and outlet in the top lid can be used to bubble the solution and evacuate gases from the chamber. It well fits aqueous (EPDM O-Rings) and )organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight.Please note: this product is not available from Metrohm Germany.
014RDX
Double-tank etch cell setupThis is a horizontally mounted, double-tank cell typically used for anodization of Si-wafers with electrolyte backside contact. It consists of two polyether ether ketone (PEEK)gas-tight chambers each equipped with sapphire wafer serving as window for illumination allowing light-assisted porous Si formation.It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The Si substrate is mounted in between these chambers and sealed with O-rings under magnetic/screw mount. The preparation of a whole porous Si substrate with this cell is possible at one simple etching step, assuring high reproducibility.Please note: this product is not available from Metrohm Germany.
015RDX
Photo-electrochemical double-sided cell setupThis is a horizontally mounted, single compartment photo-electrochemical cell used to simultaneously investigate thin film photo-anodes and (photo-) cathodes. This cell allows several approaches to perform measurements in 2- or 3-electrode setups.It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass). The cathode (counter electrode) is either mounted in a top casing or attached on the other side of the cell as a thin film deposited on rigid or flexible substrate. The reference electrode is mounted in a top casing.The cell elements are made of PEEK. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight having gas inlet and outlet, which can be used to bubble the solution and evacuate gases from the chamber.Please note: this product is not available from Metrohm Germany.
3500001940
Ethernet cable (3m)Standard network Cable (Ethernet, LAN) used to connect the VIONIC instrument to the network
3500002000
Earth Ground CableThe Earth Ground Cable (EARTH) is a single cable, 0.5 m in length, with two 4 mm banana connectors, one on each end. The Earth Ground Cable is delivered with VIONIC and is also available to purchase separately. This cable can be used to provide an Earth ground connection to any point or accessories used in the experimental setup.
3500002010
Analog Ground CableThe Analog ground cable (AGND), is a single cable, 0.5 m in length, with one 2 mm and one 4 mm banana connectors, one on each end of the cable.This cable must be used only for ZRA (or ECN) measurements with VIONIC when operating with Floating ON.The Analog Ground Cable is an optional accessory and can be purchased separately.
3500002470
Autolab Test CellThe Autolab Test Cell provides a range of electrical circuits which can simulate typical electrochemical interfaces. It is equipped with color coded, 4 mm banana sockets (female connectors) which assure a direct connection to the 4 mm Banana Adaptive cables.The Autolab Test Cell can be used for testing the performance of the VIONIC instrument, testing and trobleshooting measurement procedures.
3500002500
4mm Banana Adaptive Cable SetEach 4mm Banana Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/CE, Sense/S and Second Sense/S2) of 0.5 m in length.Each 0.5 m cable ends with a 4 mm banana cell connector.The 4 mm Banana Adaptive Cable Set is delivered with VIONIC and is also available to purchase separately.
3500002510
2mm Banana Adaptive Cable Set: 5 cables of 0.5 m ending with 2 mm banana connectorsEach 2 mm Banana Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/CE, Sense/S and Second Sense/S2) of 0.5 m in length. Each 0.5 m cable ends with a 2 mm banana cell connector. The 2 mm Banana Adaptive Cable Set is an optional accessory for VIONIC.
3500002530
Alligator clip Adaptive Cable Set: 5 cables of 0.5 m ending with Alligator Clip connectorsEach Isolated BNC Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/ CE, Sense/S and Second Sense/S2) of 0.5 m in length. Each 0.5 m cable ends with an Isolated BNC connector. The Isolated BNC Adaptive Cable Set is an optional accessory for VIONIC. The Isolated BNC Adaptive Cable Set is an optional accessory and can be purchased separately.
3500002540
Isolated BNC Adaptive Cable Set: 5 cables of 0.5 m ending with Isolated BNC connectorsEach Isolated BNC Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/ CE, Sense/S and Second Sense/S2) of 0.5 m in length.Each 0.5 m cable ends with an Isolated BNC connector.The Isolated BNC Adaptive Cable Set is an optional accessory and can be purchased separately.
3500002750
4mm Banana Adaptive Cable Set for High Frequency EISEach 4mm Banana Adaptive Cable Set for High Frequency EIS comes with 3 cables (Working/WE, Reference/RE, and a Ground bridge cable) each 0.25 m in length. Each 0.25 m cable ends with a 4 mm banana cell connector. The 4 mm Banana Adaptive Cable Set for High Frequency EIS is delivered with VIONIC and is also available to purchase separately. These cables must be used ONLY for EIS measurements at frequencies higher than 1 MHz.
3500002880
GSTAT Floating Stabilization boxThe GSTAT Floating Stabilization box is for measurements conducted with VIONIC operated simultaneously in Galvanostatic and FLOATING mode.The GSTAT Floating Stabilization box is an optional accessory and can be purchased separately.
3500003120
Trigger cable for PGSTAT302N Hyphenated EC-Raman SolutionsThis trigger cable connects the Autolab PGSTAT302N to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.
3500003130
Trigger cable for PGSTAT204 Hyphenated EC-Raman SolutionsThis trigger cable connects the Autolab PGSTAT204 to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.
3500003600
20 A current boosterThe Booster20A module increases the maximum current of the PGSTAT302N to 20 Ampere. The compliance voltage of the system is 20 V in combination with the Booster20A.With its fast response time, the Autolab Booster20A has been optimized to perform electrochemical impedance measurements, in combination with the FRA32M module, on fuel cells, batteries and super-capacitors. The booster is able to handle active as well as passive cells. The Booster20A can be used to measure the charge and discharge characteristics of super-capacitors, perform measurements on fuel cells or perform DC or AC measurements on large area electrodes.
6.01201.000
Rod stirrer SGJ sleeve for 6.01403.050Rod stirrer SGJ sleeve for when using a rod stirrer instead of an homogenizer in the 6.01403.050 titration head
6.01204.000
Stirrer tipStirrer tip for 946 Portable VA Analyzer.
6.01256.000
Measuring head (scTRACE Gold) for the 946 Portable VA Analyzer measuring stand (for older instrument versions)Measuring head with built-in stirrer for measurements with the scTRACE Gold.
6.01256.010
Measuring head (scTRACE Gold) for the 946 Portable VA Analyzer measuring standMeasuring head with built-in stirrer for measurements with the scTRACE Gold.
6.01256.020
Measuring head (SPE) for the 946 Portable VA Analyzer measuring standMeasuring head with integrated stirrer for measurements with screen-printed electrodes (SPE).
6.01400.000
Sample beakers, clear glass, 250 mL, 10 piecesSample beakers, clear glass, 250 mL, suitable for 602041010 OMNIS sample rack, 10 pieces.
6.01400.003
Sample beakers, amber glass, 250 mL, 10 piecesSample beakers, amber glass, 250 mL, suitable for 602041010 OMNIS sample rack, 10 pieces.
6.01400.100
Sample beakers, plastic (PP), 250 mL, 10 piecesSample beakers, plastic (polypropylene, PP), 250 mL, suitable for 602041010 OMNIS sample rack, 10 pieces.
6.01400.200
Sample beakers, plastic (PP), 120 mL, 20 piecesSample beakers, plastic (polypropylene, PP), 120 mL, suitable for 602041030 OMNIS sample rack, 20 pieces.
6.01400.300
Sample beakers, clear glass, 120 mL, 20 piecesSample beakers, clear glass, 120 mL, suitable for 602041030 OMNIS sample rack, 20 pieces.
6.01400.303
Sample beakers, amber glass, 120 mL, 20 piecesSample beakers, amber glass, 120 mL, suitable for 602041030 OMNIS sample rack, 20 pieces
6.01402.000
Sample beakers, clear glass, 75 mL, 30 piecesSample beakers, clear glass, 75 mL, suitable for 602041040 OMNIS sample rack, 30 pieces
6.01402.003
Sample beakers, amber glass, 75 mL, 30 piecesSample beakers, amber glass, 75 mL, suitable for 602041040 OMNIS sample rack, 30 pieces
6.01403.000
Titration head 6xNS14 / 3xNS9 (P&P)Titration head with 6 NS14 and 3 NS 9 openings for use in Pick&Place modules of the OMNIS Sample Robot Pick&Place
6.01403.010
Titration head 4xM10 (P&P)Titration head with 4 M10 openings for use in Pick&Place modules of the OMNIS Sample Robot Pick&Place
6.01403.020
Titration head 4xM10 for KFT (P&P)Titration head with 4 M10 openings for Karl Fischer titration in Pick&Place modules of the OMNIS Sample Robot Pick&Place with 4 M10 screw nipples and stoppers.
6.01403.030
Titration head 3xNS14 / 4x6.4 mm (P&P)Titration head with 3 NS14 and 4x 6.4 mm openings for using 120 mL beakers in Pick&Place modules of the OMNIS Sample Robot Pick&Place with two retracted dosing tips. Prepared for being equipped with rinsing and aspiration tubing.
6.01403.040
Titration head 2xNS14 (P&P)Titration head with 2 NS14 openings for use in Pick&Place modules of the OMNIS Sample Robot Pick&Place with 3 retracted dosing tips. Prepared for being equipped with rinsing nozzles. One aspiration tube is already retracted into the titration head.
6.01403.050
Titration head for KFT with reinforced tips (P&P)Titration head for Karl Fischer titration in Pick&Place modules of the OMNIS Sample Robot Pick&Place. In addition to 2 reinforced antidiffusion tips, the titration head offers an opening for using an homogenizer (Polytron 1300D) or rod stirrer.
6.01403.060
Titration head 3xNS14 / 4x6.4 mm for 200 mL disposable beaker (P&P)Titration head with 3 NS14 and 4x 6.4 mm openings for using 200 mL PP disposable beakers (6.1459.310) or 150 mL beaker glasses (high shape, without spout) in Pick&Place modules of the OMNIS Sample Robot Pick&Place with two retracted dosing tips. Prepared for being equipped with rinsing and aspiration tubing.
6.01403.070
Titration head 3 x NS14 / 4 x 6.4 mm; 4 x dosing tipTitration head with 3 NS14 and 4 x 6.4 mm openings for using 200 mL PP disposable beakers (6.1459.310) or 150 mL beaker glasses (tall shape, without spout) in Pick&Place modules of the OMNIS Sample Robot Pick&Place with four retracted dosing tips. Prepared for being equipped with rinsing and aspiration tubing.
6.01404.020
Beaker adapter for 200 mL sample beakerBeaker adapter for centering the 200 mL sample beaker in the slide of the Pick&Place modules.
6.01404.030
Beaker adapter for OMNIS 120 mL sample beakerBeaker adapter for centering the 120 mL sample beaker in the slide of the Pick&Place modules
6.01404.040
Beaker adapter for OMNIS 75 mL sample beakerBeaker adapter for centering the 75 mL sample beaker in the slide of the Pick&Place modules
6.01404.050
Beaker adapter for 150 mL sample beakerBeaker adapter for centering the 150 mL sample beaker in the slide of the Pick&Place modules.
6.01405.000
5 x SGJ 14 titration vessel lid OMNISTitration vessel lid with five SGJ 14 openings for 601406XX0 titration vessels with screw cap.
6.01405.010
OMNIS titration vessel lid for volumetric Karl Fischer titrationTitration vessel lid for volumetric Karl Fischer titration with an OMNIS titrator.
6.01405.040
OMNIS titration vessel lid for 601406XXX titration vessels for PolytronTitration vessel lid for volumetric Karl Fischer titration with an OMNIS titrator with Polytron.
6.01405.050
Eco titration vessel lid for volumetric Karl Fischer titrationTitration vessel lid for volumetric Karl Fischer titration with an Eco KF titrator
6.01405.060
Eco titration vessel lid for 601406XXX titration vessels for PolytronTitration vessel lid for volumetric Karl Fischer titration with an Eco KF titrator with Polytron
6.01405.070
5 x SGJ 14 titration vessel lid EcoTitration vessel lid with 5 NS14 openings for the Eco Titrator / Eco Dosimat for the titration vessels 6.01406.220 und 6.01406.250.
6.01406.010
Adsorber tube with lidAdsorber tube with lid for OMNIS Karl Fischer titrator, volumetric
6.01406.220
20 – 90 mL titration vessel20 – 90 mL titration vessel with screw top for use with 6014050X0 titration vessel lids.
6.01406.250
50 – 150 mL titration vessel50 – 150 mL titration vessel with screw top for use with 6014050X0 titration vessel lids.