5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 0.65 m)
6.00925.100
5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 0.65 m)
en
6.00925.100
Prezentare generală a caracteristicilor
5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.
This sensor is suitable for measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:
- Drinking water
- Surface water
- Waste water
Specificații tehnice
| Shaft material | PEEK |
|---|---|
| Shaft material (completion) | PCTFE/PEEK |
| Measuring range (theoretical) | 0.005...200 |
| Measuring unit | mS/cm |
| Temperature range, long-term (°C) | 0...70 |
| Temperature range, short-term (°C) | 0...70 |
| Max. installation length (mm) | 125 |
| SGJ sleeve | Flexible SGJ sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 34 |
| Electrode plug-in head | Fixed cable, plug N |
| Temperature sensor | Pt1000 |
| Type | 5-ring, Pt |
| Cell constant, guide value (1/cm) | 0.7 |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
-
- Measuring module conductivity
- 6.02101.020
- Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.
- <p>Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.</p>
- PCS
- 1
- KCl ion standard 250 mL
- 6.2301.060
- KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).
- <p>KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).</p>
- PCS
- 1
- Conductivity standard 100 µS/cm 250 mL
- 6.2324.010
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1
- Conductivity standard 100 µS/cm, 5 x 30 mL
- 6.2324.110
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1