Byli jste přesměrováni na vaši místní verzi požadované stránky
IC Amperometric Detector

IC Amperometric Detector

2.850.9110

IC Amperometric Detector

en

2.850.9110

Přehled vlastností

Compact and intelligent amperometric detector for intelligent IC instruments. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD and CV, as well as the excellent signal/noise ratio and the very fast stabilization of the measuring signal guarantee the highest in measurement precision.

    • Connecting cable to 61257XXX
    • 6.2165.000
    • Connecting cable for amperometric detector cell.
    • Connecting cable for amperometric detector cell.
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • IC Amperometric Detector
    • 1.850.9110
    • Compact and intelligent amperometric detector for intelligent IC instruments. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD and CV, as well as the excellent signal/noise ratio and the very fast stabilization of the measuring signal guarantee the highest in measurement precision.
    • <p>Compact and intelligent amperometric detector for intelligent IC instruments. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD and CV, as well as the excellent signal/noise ratio and the very fast stabilization of the measuring signal guarantee the highest in measurement precision.</p>
    • PCS
    • 1
    • Connecting cable to 61257XXX
    • 6.2165.000
    • Connecting cable for amperometric detector cell.
    • Connecting cable for amperometric detector cell.
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Wall-Jet Cell
    • 6.1257.010
    • Amperometric detector cell with Wall-Jet geometry.
    • <p>Amperometric detector cell with Wall-Jet geometry.</p>
    • PCS
    • 1
    • Thin-Layer cell
    • 6.1257.100
    • Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).
    • <p>Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).</p>
    • PCS
    • 1
    • Au working electrode, 3 mm
    • 6.1257.210
    • Working electrode made of gold for amperometric detection, 3 mm diameter.
    • Working electrode made of gold for amperometric detection, 3 mm diameter.
    • PCS
    • 1
    • GC working electrode
    • 6.1257.220
    • Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.
    • <p>Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.</p>
    • PCS
    • 1
    • Pt working electrode
    • 6.1257.230
    • Platinum working electrode for amperometric detection, 3 mm diameter.
    • Platinum working electrode for amperometric detection, 3 mm diameter.
    • PCS
    • 1
    • Ag working electrode
    • 6.1257.240
    • Silver working electrode for amperometric detection, 3 mm diameter.
    • Silver working electrode for amperometric detection, 3 mm diameter.
    • PCS
    • 1
    • Au working electrode, 2 mm
    • 6.1257.260
    • Working electrode made of gold for amperometric detection, 2 mm diameter.
    • Working electrode made of gold for amperometric detection, 2 mm diameter.
    • PCS
    • 1
    • Cu working electrode, 2 mm
    • 6.1257.270
    • Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.
    • <p>Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.</p>
    • PCS
    • 1
    • Ag/AgCl reference electrode for 6.1257.xxx
    • 6.1257.720
    • Silver/silver chloride reference electrode for amperometric detection.
    • <p>Silver/silver chloride reference electrode for amperometric detection.</p>
    • PCS
    • 1
    • 50 µm spacer to Thin-Layer cell
    • 6.1257.820
    • 50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.
    • <p>50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.</p>
    • PCS
    • 1
    • 25 µm spacer for the Wall-Jet cell
    • 6.1257.830
    • 25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.
    • <p>25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.</p>
    • PCS
    • 1
    • 25 µm spacer to Thin-Layer cell
    • 6.1257.840
    • 25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.
    • <p>25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.</p>
    • PCS
    • 1
    • Maintenance set for 6.1257.2XX working electrodes
    • 6.2802.200
    • Tool for removing protruding PEEK materials and for subsequent polishing of working electrodes including polishing disks.
    • <p>Tool for removing protruding PEEK materials and for subsequent polishing of working electrodes including polishing disks.</p>
    • PCS
    • 1
    • Polishing disks for 6.2802.200 maintenance set
    • 6.2802.210
    • Replacement polishing disks for maintenance tool for 6.1257.2XX working electrodes.
    • <p>Replacement polishing disks for maintenance tool for 6.1257.2XX working electrodes.</p>
    • PCS
    • 1
    • Accessory kit: IC Amperometric Detector
    • 6.5000.200
    • Optional accessory kit for the IC Amperometric Detector for determinations in low-conductivity solutions.
    • <p>Optional accessory kit for the IC Amperometric Detector for determinations in low-conductivity solutions.</p>
    • PCS
    • 1
    • IQ/OQ Kit for IC
    • 6.5333.000
    • The IQ/OQ Kit contains all parts and standard solutions required for IQ/OQ in ion chromatography.
    • The IQ/OQ Kit contains all parts and standard solutions required for IQ/OQ in ion chromatography.
    • PCS
    • 1
    • IC equipment Wall-Jet cell: without electrodes
    • 6.5337.000
    • Equipment comprised of Wall-Jet cell with additional accessories, without electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories, without electrode.</p>
    • PCS
    • 1
    • IC equipment Wall-Jet cell: Carb (Au, Pd)
    • 6.5337.010
    • Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.</p>
    • PCS
    • 1
    • IC equipment Wall-Jet cell: Cyanide (Ag, Pd)
    • 6.5337.020
    • Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.</p>
    • PCS
    • 1
    • IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).
    • 6.5337.030
    • Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.</p>
    • PCS
    • 1
    • IC equipment Thin-Layer cell: without electrodes
    • 6.5337.200
    • Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.
    • <p>Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.</p>
    • PCS
    • 1
    • IC equipment: Thin-Layer cell: Carb (Au,Pd)
    • 6.5337.210
    • Equipment comprising Thin-Layer cell with additional accessories, with electrodes for carbohydrate analysis with a gold working electrode and a Pd reference electrode.
    • <p>Equipment comprising Thin-Layer cell with additional accessories, with electrodes for carbohydrate analysis with a gold working electrode and a Pd reference electrode.</p>
    • PCS
    • 1