Foi redireccionado para a sua versão local da página solicitada.
IC Amperometric Detector

IC Amperometric Detector

2.850.9110

    • Connecting cable to 61257XXX
    • 6.2165.000
    • Connecting cable for amperometric detector cell.
    • Connecting cable for amperometric detector cell.
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • IC Amperometric Detector
    • 1.850.9110
    • Compact and intelligent amperometric detector for intelligent IC instruments. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD and CV, as well as the excellent signal/noise ratio and the very fast stabilization of the measuring signal guarantee the highest in measurement precision.
    • <p>Compact and intelligent amperometric detector for intelligent IC instruments. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD and CV, as well as the excellent signal/noise ratio and the very fast stabilization of the measuring signal guarantee the highest in measurement precision.</p>
    • PCS
    • 1
    • Connecting cable to 61257XXX
    • 6.2165.000
    • Connecting cable for amperometric detector cell.
    • Connecting cable for amperometric detector cell.
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Wall-Jet Cell
    • 6.1257.010
    • Amperometric detector cell with Wall-Jet geometry.
    • <p>Amperometric detector cell with Wall-Jet geometry.</p>
    • PCS
    • 1
    • Thin-Layer cell
    • 6.1257.100
    • Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).
    • <p>Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).</p>
    • PCS
    • 1
    • Au working electrode, 3 mm
    • 6.1257.210
    • Working electrode made of gold for amperometric detection, 3 mm diameter.
    • Working electrode made of gold for amperometric detection, 3 mm diameter.
    • PCS
    • 1
    • GC working electrode
    • 6.1257.220
    • Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.
    • <p>Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.</p>
    • PCS
    • 1
    • Pt working electrode
    • 6.1257.230
    • Platinum working electrode for amperometric detection, 3 mm diameter.
    • Platinum working electrode for amperometric detection, 3 mm diameter.
    • PCS
    • 1
    • Ag working electrode
    • 6.1257.240
    • Silver working electrode for amperometric detection, 3 mm diameter.
    • Silver working electrode for amperometric detection, 3 mm diameter.
    • PCS
    • 1
    • Au working electrode, 2 mm
    • 6.1257.260
    • Working electrode made of gold for amperometric detection, 2 mm diameter.
    • Working electrode made of gold for amperometric detection, 2 mm diameter.
    • PCS
    • 1
    • Cu working electrode, 2 mm
    • 6.1257.270
    • Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.
    • <p>Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.</p>
    • PCS
    • 1
    • Ag/AgCl reference electrode for 6.1257.xxx
    • 6.1257.720
    • Silver/silver chloride reference electrode for amperometric detection.
    • <p>Silver/silver chloride reference electrode for amperometric detection.</p>
    • PCS
    • 1
    • 50 µm spacer to Thin-Layer cell
    • 6.1257.820
    • 50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.
    • <p>50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.</p>
    • PCS
    • 1
    • 25 µm spacer for the Wall-Jet cell
    • 6.1257.830
    • 25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.
    • <p>25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.</p>
    • PCS
    • 1
    • 25 µm spacer to Thin-Layer cell
    • 6.1257.840
    • 25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.
    • <p>25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.</p>
    • PCS
    • 1
    • Maintenance set for 6.1257.2XX working electrodes
    • 6.2802.200
    • Tool for removing protruding PEEK materials and for subsequent polishing of working electrodes including polishing disks.
    • <p>Tool for removing protruding PEEK materials and for subsequent polishing of working electrodes including polishing disks.</p>
    • PCS
    • 1
    • Polishing disks for 6.2802.200 maintenance set
    • 6.2802.210
    • Replacement polishing disks for maintenance tool for 6.1257.2XX working electrodes.
    • <p>Replacement polishing disks for maintenance tool for 6.1257.2XX working electrodes.</p>
    • PCS
    • 1
    • Accessory kit: IC Amperometric Detector
    • 6.5000.200
    • Optional accessory kit for the IC Amperometric Detector for determinations in low-conductivity solutions.
    • <p>Optional accessory kit for the IC Amperometric Detector for determinations in low-conductivity solutions.</p>
    • PCS
    • 1
    • IQ/OQ Kit for IC
    • 6.5333.000
    • The IQ/OQ Kit contains all parts and standard solutions required for IQ/OQ in ion chromatography.
    • The IQ/OQ Kit contains all parts and standard solutions required for IQ/OQ in ion chromatography.
    • PCS
    • 1
    • IC equipment Wall-Jet cell: without electrodes
    • 6.5337.000
    • Equipment comprised of Wall-Jet cell with additional accessories, without electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories, without electrode.</p>
    • PCS
    • 1
    • IC equipment Wall-Jet cell: Carb (Au, Pd)
    • 6.5337.010
    • Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.</p>
    • PCS
    • 1
    • IC equipment Wall-Jet cell: Cyanide (Ag, Pd)
    • 6.5337.020
    • Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.</p>
    • PCS
    • 1
    • IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).
    • 6.5337.030
    • Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.
    • <p>Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.</p>
    • PCS
    • 1
    • IC equipment Thin-Layer cell: without electrodes
    • 6.5337.200
    • Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.
    • <p>Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.</p>
    • PCS
    • 1
    • IC equipment: Thin-Layer cell: Carb (Au,Pd)
    • 6.5337.210
    • Equipment comprising Thin-Layer cell with additional accessories, with electrodes for carbohydrate analysis with a gold working electrode and a Pd reference electrode.
    • <p>Equipment comprising Thin-Layer cell with additional accessories, with electrodes for carbohydrate analysis with a gold working electrode and a Pd reference electrode.</p>
    • PCS
    • 1