Metrosep Carb 2 - 150/4.0

Metrosep Carb 2 - 150/4.0

6.1090.420

Metrosep Carb 2 - 150/4.0

en

6.1090.420

Prezentare generală a caracteristicilor

The Metrosep Carb 2 - 150/4.0 IC column is particularly suitable for the determination of carbohydrates using alkaline eluents and pulsed amperometric detection. The anion exchanger column is based on a styrene-divinylbenzene copolymer. It is stable in the range of pH = 0 to pH = 14 and separates monosaccharides and disaccharides. It is also suitable for the analysis of sugar alcohols, anhydrous sugars, oligosaccharides, etc. The column capacity has been optimized to enable the combination of rapid separations and excellent separation properties.

Specificații tehnice

Housing materialPEEK
Carrier materialPolystyrene-divinylbenzene copolymer with quaternary ammonium groups
Particle size5.0 µm
Standard flow0.5 mL/min
Maximum pressure20 MPa
Maximum flow1.2 mL/min
pH range0–14
Column dimensions 150 x 4.0 mm
Temperature range20–60 °C
Standard temperature 30 °C

Cromatogramă

  • Cromatogramă
  • Cromatogramă
  • Cromatogramă
  • Cromatogramă
  • Cromatogramă
This field is required.
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep BO3 Trap 1 - 100/4.0
    • 6.1015.200
    • Trap column for the removal of borate contaminants from the eluent. The Metrosep BO3 Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.
    • <p>Trap column for the removal of borate contaminants from the eluent. The Metrosep BO<sub>3</sub> Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.</p>
    • PCS
    • 1
    • Metrosep CO3 Trap 1 - 100/4.0
    • 6.1015.300
    • Trap column for the removal of carbonate traces in hydroxide eluents.
    • <p>Trap column for the removal of carbonate traces in hydroxide eluents.</p>
    • PCS
    • 1
    • Metrosep Carb 2 Guard/4.0
    • 6.1090.500
    • The Metrosep Carb 2 Guard/4.0 effectively removes contamination, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
    • <p>The Metrosep Carb 2 Guard/4.0 effectively removes contamination, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.</p>
    • PCS
    • 1
    • Metrosep Carb 2 S-Guard/4.0
    • 6.1090.510
    • The Metrosep Carb 2 S-Guard/4.0 effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
    • <p>The Metrosep Carb 2 S-Guard/4.0 effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.</p>
    • PCS
    • 1