Metrosep A Supp 17 - 150/4.0
6.01032.420
Metrosep A Supp 17 - 150/4.0
en
6.01032.420
Prezentare generală a caracteristicilor
The Metrosep A Supp 17 - 150/4.0 separation column is the column of choice for anion determinations that require good separating efficiency and short separation times at room temperature. The maximum flow rate of 1.4 mL/min then also makes it possible to optimize the determination. The Metrosep A-Supp-17 columns convince with their good price-performance ratio.
Specificații tehnice
| Housing material | PEEK |
|---|---|
| Carrier material | Polystyrene-divinylbenzene copolymer with quaternary ammonium groups |
| Particle size | 5 µm |
| Standard flow | 0.6 mL/min |
| Maximum pressure | 18 MPa |
| Maximum flow | 1.4 mL/min |
| pH range | 0–14 |
| Column dimensions | 150 x 4.0 mm |
| Temperature range | 10–70 °C |
| Standard temperature | 25 °C |
Cromatogramă
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Threaded stopper
- 6.2744.060
- For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
- <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
- PCS
- 2
-
- Metrosep A Supp 17 Guard/4.0
- 6.01032.500
- The Metrosep A Supp 17 Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.
- <p>The Metrosep A Supp 17 Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.</p>
- PCS
- 1
- Metrosep A Supp 17 S-Guard/4.0
- 6.01032.510
- The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
- <p>The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.</p>
- PCS
- 1
- Metrosep A Supp 17 S-Guard - 50/4.0
- 6.01032.530
- The Metrosep A Supp 17 S-Guard 50/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
- <p>The Metrosep A Supp 17 S-Guard 50/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.</p>
- PCS
- 1