Spearhead electrode with Pt1000
6.00226.600
Spearhead electrode with Pt1000
en
6.00226.600
Feature overview
Maintenance-free combined pH electrode (gel electrolyte) for piercing measurements of all types (e.g., with cheese, meat, dough) with integrated Pt1000 temperature sensor. The electrode is stored in saturated potassium chloride solution c(KCl) = sat. (6.2308.000) and is not suitable for low-ion solutions. The ageing indicator gives early indication of when the electrode needs to be replaced.
Tech specs
| SGJ sleeve | Flexible SGJ sleeve |
|---|---|
| Membrane glass type | Spec. |
| Resistance (kOhm) | 20 |
| Shaft material | Glass |
| Measuring unit | pH |
| Temperature range, long-term (°C) | 0...40 |
| Temperature range, short-term (°C) | 0...60 |
| pH range | 1...11 |
| Max. installation length (mm) | 98 |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 6.4 |
| Min. immersion depth (mm) | 10 |
| Electrode plug-in head | Metrohm plug-in head U |
| Indicator electrode shape | Needle |
| Membrane resistance | 200...500 |
| Electrode zero point (mV) | ±20 |
| Electrode slope | >0.97 |
| Temperature sensor | Pt1000 |
| Diaphragm | Twin pore |
| Reference electrolyte type | Gel |
| Reference system | LL system |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- Stk
- 100
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- Stk
- 100
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- Stk
- 100
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- Stk
- 100
-
- Electrolyte KCl (sat.), 250 mL
- 6.2308.000
- Electrolyte KCl (sat.), 250 mL
- Electrolyte KCl (sat.), 250 mL
- PCS
- 1
- Electrode cable for plug in head U/plug F, 2x2 mm B, 1m
- 6.2104.600
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- PCS
- 1
- Electrode cable for plug in head U/plug F, 2x2 mm B, 2m
- 6.2104.610
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).
- PCS
- 1