Byli jste přesměrováni na vaši místní verzi požadované stránky
943 Professional Reactor Vario

943 Professional Reactor Vario

2.943.0110

943 Professional Reactor Vario

en

2.943.0110

Přehled vlastností

The 943 Professional Reactor Vario is a heatable reactor, especially developed for pre- and post-column derivatization. It captivates by its robustness, the fast heating rate and the possibility of carrying out reactions at up to 150 °C.

    • Metrosep BP 1 Guard/2.0
    • 6.1015.100
    • The Metrosep BP 1 Guard/2.0 is used to generate a sufficiently high working pressure in the flow path of post-column reagents. They are used in combination with a high-pressure pump for conveying the post-column reagent in the Professional Reactor.
    • <p>The Metrosep BP 1 Guard/2.0 is used to generate a sufficiently high working pressure in the flow path of post-column reagents. They are used in combination with a high-pressure pump for conveying the post-column reagent in the Professional Reactor.</p>
    • PCS
    • 1
    • Pressure screw 5x
    • 6.2744.010
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Metrosep BP 1 Guard/2.0
    • 6.1015.100
    • The Metrosep BP 1 Guard/2.0 is used to generate a sufficiently high working pressure in the flow path of post-column reagents. They are used in combination with a high-pressure pump for conveying the post-column reagent in the Professional Reactor.
    • <p>The Metrosep BP 1 Guard/2.0 is used to generate a sufficiently high working pressure in the flow path of post-column reagents. They are used in combination with a high-pressure pump for conveying the post-column reagent in the Professional Reactor.</p>
    • PCS
    • 1
    • Pressure screw 5x
    • 6.2744.010
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Pressure screw 2x
    • 6.2744.014
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • With UNF 10/32 connection. For the connection of PEEK capillaries
    • PCS
    • 1
    • Bottle cap 2 x M6, 1 x M8 to 6.1608.120
    • 6.1602.200
    • Bottle cap for eluent bottles made of PP for eluents, post-column derivatization solutions, etc. The PP eluent bottle can withstand gas pressure when this bottle cap is used.
    • <p>Bottle cap for eluent bottles made of PP for eluents, post-column derivatization solutions, etc. The PP eluent bottle can withstand gas pressure when this bottle cap is used.</p>
    • PCS
    • 1
    • PP eluent bottle, 2 L
    • 6.1608.120
    • Eluent bottle for applications where glass should be avoided.
    • Eluent bottle for applications where glass should be avoided.
    • PCS
    • 1
    • System Connector
    • 6.2061.120
    • Connects an IC module with the footprint of a Professional IC with a Compact IC
    • Connects an IC module with the footprint of a Professional IC with a Compact IC
    • PCS
    • 1
    • PEEK coupling M6 / UNF 10/32
    • 6.2744.320
    • Connecting transfer tubing (M6) with capillaries (UNF 10/32).
    • <p>Connecting transfer tubing (M6) with capillaries (UNF 10/32).</p>
    • PCS
    • 1
    • HT reactor plate, complete, for Professional Reactor
    • 6.2845.110
    • Reactor plate with reactor for PCR applications at high temperatures (> 120 °C). With PEEK reactor capillaries.
    • <p>Reactor plate with reactor for PCR applications at high temperatures (&gt; 120 °C). With PEEK reactor capillaries.</p>
    • PCS
    • 1
    • HT reactor, complete, for 6.2845.110
    • 6.2845.210
    • Reactor for PCR applications at high temperatures (> 120 °C). With PEEK reactor capillaries.
    • <p>Reactor for PCR applications at high temperatures (&gt; 120 °C). With PEEK reactor capillaries.</p>
    • PCS
    • 1