You have been redirected to your local version of the requested page
Metrosep A Supp 16 - 100/4.0

Metrosep A Supp 16 - 100/4.0

6.1031.410

Metrosep A Supp 16 - 100/4.0

en

6.1031.410

Prezentare generală a caracteristicilor

The Metrosep A Supp 16 is a high capacity separation column based on a surface-functionalized polystyrene-divinylbenzene copolymer. The functional groups are bonded covalently. The morphology of the anion exchanger results in unique selectivity. In addition, this column type is noteworthy for its high mechanical and chemical resilience.

The column is well-suited to applications with a high ionic load but which require only relatively low resolution. Using the Metrosep A Supp 16 - 100/4.0 to determine bromate in water by means of the triiodide method (EPA 326, DIN EN ISO 11206) is another of its numerous applications.

Specificații tehnice

Housing materialPEEK
Carrier materialPolystyrene-divinylbenzene copolymer with quaternary ammonium groups
Particle size4.6 µm
Standard flow0.8 mL/min
Maximum pressure20 MPa
Maximum flow1.2 mL/min
pH range0–14
Column dimensions 100 x 4.0 mm
Temperature range10–70 °C

Cromatogramă

  • Cromatogramă
  • Cromatogramă
  • Cromatogramă
This field is required.
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Threaded stopper
    • 6.2744.060
    • For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.
    • <p>For UNF 10/32. Stopper for IC, e.g. for the sealing of columns.</p>
    • PCS
    • 2
    • Metrosep A Supp 16 Guard/4.0
    • 6.1031.500
    • The Metrosep A Supp 16 Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.
    • <p>The Metrosep A Supp 16 Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.</p>
    • PCS
    • 1
    • Metrosep A Supp 16 S-Guard/4.0
    • 6.1031.510
    • The Metrosep A Supp 16 S-Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.
    • <p>The Metrosep A Supp 16 S-Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.</p>
    • PCS
    • 1