You have been redirected to your local version of the requested page
Combined dCa ISE

Combined dCa ISE

6.00502.300

Combined dCa ISE

en

6.00502.300

Prezentare generală a caracteristicilor

Digital, combined calcium-selective electrode for OMNIS.
This ISE is suitable for:
 

  • Ion measurements of Ca2+ (1*10-7 to 1 mol/L) in aqueous solutions
  • Complexometric (back) titrations (e.g., determination of water hardness)


Thanks to a robust/break-proof plastic shaft made of propylene and an impact protection for the polymer membrane, this sensor is mechanically very resistant.
The reference electrolyte used is c(KCl) = 3 mol/L.
dTrodes can be used on OMNIS Titrators.

Specificații tehnice

Shaft materialPMMA/PP
Shaft material (completion)PMMA inner pipe
Measuring range (theoretical)5*10E-7 ... 1
Temperature range, long-term (°C)0 ... 40
Temperature range, short-term (°C)0 ... 40
pH range2 ... 12
Indicator electrode shapeFlat
Max. installation length (mm)113
SGJ sleeveFlexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)10
Electrode plug-in headMetrohm plug-in head Q
Indicator electrode typePolymer (Ca)
Membrane materialPolymer
IonCa2+
Reference electrolyte typec(KCl) = 3 mol/L
DiaphragmCeramic pin
Reference systemAg wire/AgCl
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 0.55 m
    • 6.02104.300
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 1.5 m
    • 6.02104.310
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrolyte 3 mol/L KCl (250 mL)
    • 6.2308.020
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
    • PCS
    • 1