Chuyển hướng tin nhắn
856 Conductivity Module

856 Conductivity Module

2.856.0010

    • 856 Conductivity Module
    • 1.856.0010
    • Conductivity measuring module as supplement to an existing Titrando system or "stand-alone" in combination with a 900 Touch Control. With the 856 Conductivity Module, not only conductivity and temperature can be determined, but also TDS and salinity. It supports state-of-the-art conductivity measuring cells, i.e. 5-ring measuring cells. Thanks to the galvanically isolated measuring input, pH value and conductivity can be measured in the same beaker without interference.The Conductivity Module is equipped with two USB interfaces for connecting printers, barcode readers or sample changers and four MSB interfaces for stirrers or Dosinos.Both in conjunction with the 900 Touch Control as stand-alone instrument and also integrated in tiamo™ full (from 2.0), it is in compliance with GLP and FDA 21 CFR part 11 requirements.
    • <p>Conductivity measuring module as supplement to an existing Titrando system or "stand-alone" in combination with a 900 Touch Control. With the 856 Conductivity Module, not only conductivity and temperature can be determined, but also TDS and salinity. It supports state-of-the-art conductivity measuring cells, i.e. 5-ring measuring cells. <br/>Thanks to the galvanically isolated measuring input, pH value and conductivity can be measured in the same beaker without interference.<br/><br/>The Conductivity Module is equipped with two USB interfaces for connecting printers, barcode readers or sample changers and four MSB interfaces for stirrers or Dosinos.<br/>Both in conjunction with the 900 Touch Control as stand-alone instrument and also integrated in <em><strong>tiamo</strong></em>™ full (from 2.0), it is in compliance with GLP and FDA 21 CFR part 11 requirements.</p>
    • PCS
    • 1
    • 801 Stirrer
    • 2.801.0010
    • Magnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus).
    • <p>Magnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus).</p>
    • PCS
    • 1
    • 5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable)
    • 6.0915.100
    • 5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (1.2 m) for connecting to an 856 Conductivity Module.This sensor is suitable for measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:drinking water; surface water; wastewater;  
    • <p>5-ring conductivity measuring cell with cell constant c = 0.7 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (1.2 m) for connecting to an 856 Conductivity Module.<br />This sensor is suitable for measurements of medium conductivities (5 &micro;S/cm to 20 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p>&nbsp;</p>
    • PCS
    • 1
    • 5-ring conductivity measuring cell c = 1.0 cm-1 with Pt1000 (fixed cable)
    • 6.0915.130
    • 5-ring conductivity measuring cell with cell constant c = 1.0 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (1.2 m) for connecting to an 856 Conductivity Module in combination with a sample changer.This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 100 mS/cm), e.g., in:drinking water; surface water; wastewater;  
    • <p>5-ring conductivity measuring cell with cell constant c = 1.0 cm<sup>-1&nbsp;</sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (1.2 m) for connecting to an 856 Conductivity Module in combination with a sample changer.<br />This sensor is suitable for automated measurements of medium conductivities (5 &micro;S/cm to 100 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p>&nbsp;</p>
    • PCS
    • 1
    • Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)
    • 6.0916.040
    • Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP <645>.
    • <p>Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm<sup>-1&nbsp;</sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.<br />This sensor is suitable for measurements of low conductivities (0 &micro;S/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP &lt;645&gt;.</p>
    • PCS
    • 1
    • 5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 2 m)
    • 6.0920.100
    • 5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer.This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:drinking water; surface water; wastewater;  
    • <p>5-ring conductivity measuring cell with cell constant c = 0.7 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer.<br />This sensor is suitable for automated measurements of medium conductivities (5 &micro;S/cm to 20 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p>&nbsp;</p>
    • PCS
    • 1
    • 5-ring conductivity measuring cell c = 1.0 cm-1 with Pt1000 (fixed cable 2 m)
    • 6.0920.130
    • 5-ring conductivity measuring cell with cell constant c = 1.0 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer. This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 100 mS/cm), e.g., in:drinking water; surface water; wastewater;  
    • <p>5-ring conductivity measuring cell with cell constant c = 1.0 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer. <br />This sensor is suitable for automated measurements of medium conductivities (5 &micro;S/cm to 100 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p>&nbsp;</p>
    • PCS
    • 1
    • Adapter 4 x socket B – plug N
    • 6.2103.160
    • Adapter box for the connection of classical Metrohm Conductivity measuring cells with 4 banana plugs to the 856 Conductivity Module.
    • Adapter box for the connection of classical Metrohm Conductivity measuring cells with 4 banana plugs to&nbsp;the 856&nbsp;Conductivity Module.
    • PCS
    • 1