5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable)
6.0915.100
5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable)
vi
6.0915.100
Tổng quan
5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (1.2 m) for connecting to an 856 Conductivity Module.
This sensor is suitable for measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:
- drinking water
- surface water
- wastewater
Thông số kỹ thuật
| Shaft material | PEEK |
|---|---|
| Shaft material (completion) | PCTFE/PEEK |
| Measuring range (theoretical) | 5...20'000 (ideal) |
| Measuring unit | μS/cm |
| Temperature range, long-term (°C) | 0...70 |
| Temperature range, short-term (°C) | 0...70 |
| Max. installation length (mm) | 125 |
| SGJ sleeve | Standard ground-joint 14/12 |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 34 |
| Electrode plug-in head | Fixed cable, plug N |
| Temperature sensor | Pt1000 |
| Type | 5-ring, Pt |
| Cell constant, guide value (1/cm) | 0.7 |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- KCl ion standard 250 mL
- 6.2301.060
- KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).
- <p>KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).</p>
- PCS
- 1
- Conductivity standard 100 µS/cm 250 mL
- 6.2324.010
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1
- Conductivity standard 100 µS/cm, 5 x 30 mL
- 6.2324.110
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1
- Flow-through cell for the 6.0915.100/6.0920.100
- 6.2763.000
- Flow-through cell for the 6.0915.100/6.0920.100 5-ring conductivity measuring cell
- <p>Flow-through cell for the 6.0915.100/6.0920.100 5-ring conductivity measuring cell</p>
- PCS
- 1