Combined Pt ring electrode
6.0451.100
Combined Pt ring electrode
en
6.0451.100
Prezentare generală a caracteristicilor
Combined platinum ring electrode with a ceramic pin diaphragm.
This electrode is well suited for redox titrations when the pH value varies, e.g.:
- oxygen content according to Winkler
- determination of hydrogen peroxide with KMnO4
- diazotization titrations
c(KCl) = 3 mol/L is used as reference electrolyte and storage solution.
Specificații tehnice
| Shaft material | Glass |
|---|---|
| Measuring range (theoretical) | –2000 ... 2000 |
| Measuring unit | mV |
| Temperature range, long-term (°C) | –5 ... 80 |
| Temperature range, short-term (°C) | –5 ... 80 |
| pH range | 0 ... 14 |
| Max. installation length (mm) | 113 |
| SGJ sleeve | Flexible SGJ sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 12 |
| Min. immersion depth (mm) | 15 |
| Electrode plug-in head | Metrohm plug-in head G |
| Indicator electrode type | Pt |
| Indicator electrode shape | Ring |
| Diaphragm | Ceramic diaphragm |
| Reference electrolyte type | c(KCl) = 3 mol/L |
| Electrolyte flow rate (μl/h) at 10 cm water column | 10 ... 25 |
| Reference system | LL system |
| Resistance (kOhm) | 5 |
| Diaphragm resistance (kOhm) | 0.4 ... 0.9 |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.050
- Sleeve with SGJ 14/12 mm, polyethylene.
- Sleeve with SGJ 14/12 mm, polyethylene.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1
- Electrolyte 3 mol/L KCl (250 mL)
- 6.2308.020
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
- PCS
- 1