You have been redirected to your local version of the requested page
Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable, 2.0 m)

Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable, 2.0 m)

6.00924.080

Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable, 2.0 m)

en

6.00924.080

Prezentare generală a caracteristicilor

4-conductor conductivity measuring cell with cell constant c = 0.5 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity.
Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant and is suitable for automated measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:

  • Drinking water
  • Surface water
  • Waste water

 

Specificații tehnice

Shaft materialPEEK
Measuring range (theoretical)0.01...250
Measuring unitmS/cm
Temperature range, long-term (°C)0...70
Temperature range, short-term (°C)0...70
Max. installation length (mm)125
SGJ sleeveFlexible SGJ sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)30
Electrode plug-in headFixed cable, plug N
Temperature sensorPt1000
Type4-wire, Pt
Cell constant, guide value (1/cm)0.5
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Measuring module conductivity
    • 6.02101.020
    • Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.
    • <p>Measurement channel for one OMNIS Titrator or Titration Module for the connection of conductivity measuring cells.</p>
    • PCS
    • 1
    • KCl ion standard 250 mL
    • 6.2301.060
    • KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).
    • <p>KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 &deg;C).</p>
    • PCS
    • 1
    • Conductivity standard 100 µS/cm 250 mL
    • 6.2324.010
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • PCS
    • 1
    • Conductivity standard 100 µS/cm, 5 x 30 mL
    • 6.2324.110
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
    • PCS
    • 1