You have been redirected to your local version of the requested page
dPt Titrode

dPt Titrode

6.00401.300

dPt Titrode

en

6.00401.300

Prezentare generală a caracteristicilor

Digital, combined platinum ring electrode for OMNIS with a pH glass membrane as reference electrode.
This maintenance-free electrode is suitable for redox titrations when the pH value remains constant, e.g.:
 

  • Iodometry
  • Chromatometry
  • Cerimetry
  • Permanganometry


This electrode is stored in distilled water.
dTrodes can be used on OMNIS Titrators.
 

Specificații tehnice

Shaft materialGlass
Measuring range (theoretical)-2000 .... 2000
Measuring unitmV
Temperature range, long-term (°C)0 ... 80
Temperature range, short-term (°C)0 ... 80
pH range0 ... 14
Max. installation length (mm)125
SGJ sleeveFlexible ground-joint sleeve
Shaft diameter top (mm)12
Shaft diameter bottom (mm)12
Min. immersion depth (mm)20
Electrode plug-in headMetrohm plug-in head Q
Indicator electrode typePt
Indicator electrode shapeRing/hemisphere
Reference systempH
Resistance (kOhm)150...400
This field is required.
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Sleeve with SGJ 14/12 mm
    • 6.1236.050
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • Sleeve with SGJ 14/12 mm, polyethylene.
    • PCS
    • 1
    • Storage vessel 
    • 6.2008.040
    • Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
    • <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 0.55 m
    • 6.02104.300
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1
    • Electrode cable plug-in head Q / plug P, 1.5 m
    • 6.02104.310
    • Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.
    • <p>Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.</p>
    • PCS
    • 1