Measuring module conductivity
6.02101.020
-
- Hexagon key 2.5 mm
- 6.2621.140
- PCS
- 1
-
- Hexagon key 2.5 mm
- 6.2621.140
- PCS
- 1
-
- Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable, 0.65 m)
- 6.00921.040
- Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.This sensor is suitable for measurements of low conductivities (0 to 300 µS/cm), e.g. in deion. water or for measurements in accordance with USP <645>.
- <p>Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.<br />This sensor is suitable for measurements of low conductivities (0 to 300 µS/cm), e.g. in deion. water or for measurements in accordance with USP <645>.</p>
- PCS
- 1
- Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable, 2.0 m)
- 6.00922.040
- Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity. This sensor is suitable for automated measurements of low conductivities (0 to 300 µS/cm), e.g. in deion. water or for measurements in accordance with USP <645>.
- <p>Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm<sup>-1</sup> (guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity. <br />This sensor is suitable for automated measurements of low conductivities (0 to 300 µS/cm), e.g. in deion. water or for measurements in accordance with USP <645>.</p>
- PCS
- 1
- Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable, 0.65 m)
- 6.00923.080
- 4-conductor conductivity measuring cell with cell constant c = 0.5 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant and is suitable for measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:Drinking water; Surface water; Waste water;
- <p>4-conductor conductivity measuring cell with cell constant c = 0.5 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.</p><p>Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant and is suitable for measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:</p><ul><li>Drinking water</li><li>Surface water</li><li>Waste water</li></ul><p> </p>
- PCS
- 1
- Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable, 2.0 m)
- 6.00924.080
- 4-conductor conductivity measuring cell with cell constant c = 0.5 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity.Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant and is suitable for automated measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:Drinking water; Surface water; Waste water;
- <p>4-conductor conductivity measuring cell with cell constant c = 0.5 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity.<br />Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant and is suitable for automated measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:</p><ul><li>Drinking water</li><li>Surface water</li><li>Waste water</li></ul><p> </p>
- PCS
- 1
- 5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 0.65 m)
- 6.00925.100
- 5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.This sensor is suitable for measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:Drinking water; Surface water; Waste water;
- <p>5-ring conductivity measuring cell with cell constant c = 0.7 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.<br />This sensor is suitable for measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:</p><ul><li>Drinking water</li><li>Surface water</li><li>Waste water</li></ul><p> </p>
- PCS
- 1
- Conductivity measuring cell c = 1.6 cm-1 with Pt1000 (fixed cable, 0.65 m)
- 6.00929.140
- 3-conductor conductivity measuring cell with cell constant c = 1.6 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.This sensor is suitable for measurements of high conductivities (0.1 to 1,000 mS/cm), e.g., in:Sea water; Flush water; Physiological solutions;
- <p>3-conductor conductivity measuring cell with cell constant c = 1.6 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (0.65 m) for connecting to the OMNIS Measuring Module Conductivity.<br />This sensor is suitable for measurements of high conductivities (0.1 to 1,000 mS/cm), e.g., in:</p><ul><li>Sea water</li><li>Flush water</li><li>Physiological solutions</li></ul><p> </p>
- PCS
- 1
- Conductivity measuring cell c = 1.6 cm-1 with Pt1000 (fixed cable, 2.0 m)
- 6.00930.140
- 3-conductor conductivity measuring cell with cell constant c = 1.6 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity.This sensor is suitable for automated measurements of high conductivities (0.1 to 1000 mS/cm), e.g., in:Sea water; Flush water; Physiological solutions;
- <p>3-conductor conductivity measuring cell with cell constant c = 1.6 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and with fixed cable (2.0 m) for connecting to the OMNIS Measuring Module Conductivity.<br/>This sensor is suitable for automated measurements of high conductivities (0.1 to 1000 mS/cm), e.g., in:</p><ul><li>Sea water</li><li>Flush water</li><li>Physiological solutions</li></ul>
- PCS
- 1
- Adapter 4 x socket B – plug N
- 6.2103.160
- Adapter box for the connection of classical Metrohm Conductivity measuring cells with 4 banana plugs to the 856 Conductivity Module.
- Adapter box for the connection of classical Metrohm Conductivity measuring cells with 4 banana plugs to the 856 Conductivity Module.
- PCS
- 1