856 Conductivity Module with Touch Control, including conductivity measuring cell (stainless steel)
2.856.0120
856 Conductivity Module with Touch Control, including conductivity measuring cell (stainless steel)
vi
2.856.0120
-
- Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)
- 6.0916.040
- Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP <645>.
- <p>Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.<br />This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP <645>.</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Conductivity standard 100 µS/cm, 5 x 30 mL
- 6.2324.110
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- USB Memory Stick for 900 Touch Control
- 6.6064.010
- PCS
- 1
-
- 856 Conductivity Module
- 1.856.0010
- Conductivity measuring module as supplement to an existing Titrando system or "stand-alone" in combination with a 900 Touch Control. With the 856 Conductivity Module, not only conductivity and temperature can be determined, but also TDS and salinity. It supports state-of-the-art conductivity measuring cells, i.e. 5-ring measuring cells. Thanks to the galvanically isolated measuring input, pH value and conductivity can be measured in the same beaker without interference.The Conductivity Module is equipped with two USB interfaces for connecting printers, barcode readers or sample changers and four MSB interfaces for stirrers or Dosinos.Both in conjunction with the 900 Touch Control as stand-alone instrument and also integrated in tiamo™ full (from 2.0), it is in compliance with GLP and FDA 21 CFR part 11 requirements.
- <p>Conductivity measuring module as supplement to an existing Titrando system or "stand-alone" in combination with a 900 Touch Control. With the 856 Conductivity Module, not only conductivity and temperature can be determined, but also TDS and salinity. It supports state-of-the-art conductivity measuring cells, i.e. 5-ring measuring cells. <br/>Thanks to the galvanically isolated measuring input, pH value and conductivity can be measured in the same beaker without interference.<br/><br/>The Conductivity Module is equipped with two USB interfaces for connecting printers, barcode readers or sample changers and four MSB interfaces for stirrers or Dosinos.<br/>Both in conjunction with the 900 Touch Control as stand-alone instrument and also integrated in <em><strong>tiamo</strong></em>™ full (from 2.0), it is in compliance with GLP and FDA 21 CFR part 11 requirements.</p>
- PCS
- 1
- 900 Touch Control
- 1.900.0010
- Operating unit for the Titrandos, USB Sample Processors, 856 Conductivity Module, 867 pH Module and 846 Dosing Interface. Touch-sensitive, high-resolution color display, simple and intuitive operation, thanks to Favorites for direct method access. With integrated Ethernet interface for direct connection to the Internet and USB interface for connecting USB printers or a USB memory stick.Dialog languages: German, English, Chinese, French, Spanish, Portuguese, Russian, Korean, Polish and Italian.
- <p>Operating unit for the Titrandos, USB Sample Processors, 856 Conductivity Module, 867 pH Module and 846 Dosing Interface. Touch-sensitive, high-resolution color display, simple and intuitive operation, thanks to Favorites for direct method access. With integrated Ethernet interface for direct connection to the Internet and USB interface for connecting USB printers or a USB memory stick.</p><p>Dialog languages: German, English, Chinese, French, Spanish, Portuguese, Russian, Korean, Polish and Italian.<br/> </p>
- PCS
- 1
- Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)
- 6.0916.040
- Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP <645>.
- <p>Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.<br />This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP <645>.</p>
- PCS
- 1
- Support stand without support rod
- 6.2001.060
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- To attach an 801, 804, 803 Stirrer to a Titrando, Titrino plus, Dosimat plus or 856 and 867.
- PCS
- 1
- Clamping ring
- 6.2013.010
- For support rods with a diameter of 10 mm.
- <p>For support rods with a diameter of 10 mm.</p>
- PCS
- 1
- Support rod / 400 mm
- 6.2016.070
- PCS
- 1
- Electrode holder
- 6.2021.020
- Electrode holder for 4 electrodes and 2 buret tips
- Electrode holder for 4 electrodes and 2 buret tips
- PCS
- 1
- Conductivity standard 100 µS/cm, 5 x 30 mL
- 6.2324.110
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
- PCS
- 1
- 5 mm hex key for IC Sample Processors
- 6.2621.070
- PCS
- 1
- Hexagon key 2 mm
- 6.2621.130
- 2 mm.
- 2 mm.
- PCS
- 1
- USB Memory Stick for 900 Touch Control
- 6.6064.010
- PCS
- 1
-
- 5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 2 m)
- 6.0920.100
- 5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer.This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:drinking water; surface water; wastewater;
- <p>5-ring conductivity measuring cell with cell constant c = 0.7 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer.<br />This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p> </p>
- PCS
- 1
- 5-ring conductivity measuring cell c = 1.0 cm-1 with Pt1000 (fixed cable 2 m)
- 6.0920.130
- 5-ring conductivity measuring cell with cell constant c = 1.0 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer. This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 100 mS/cm), e.g., in:drinking water; surface water; wastewater;
- <p>5-ring conductivity measuring cell with cell constant c = 1.0 cm<sup>-1 </sup>(guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer. <br />This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 100 mS/cm), e.g., in:</p><ul><li>drinking water</li><li>surface water</li><li>wastewater</li></ul><p> </p>
- PCS
- 1