Application Finder
- 410000005-BPortable Raman Instrumentation for SERS Applications
For SERS developers and end users of SERS for specific applications to investigate low concetation levels of compounds, the centerpiece of their technological platform must be a Raman setup that provides reliable lab grade performance and is affordable and portable, allowing them to tackle real world problems. The portable i-Raman Plus system coupled with a BAC151 video microscope sampling accessory provides an ideal setup. With the performance and flexibility of use with different laser spot size and power for SERS research.
- AN-RS-028SERS Detection of Brilliant Blue
Brilliant Blue (BB) FCF, more commonly known as FD&C Blue #1, is the most commonly used blue dye worldwide for food and beverages. It is generally accepted as safe and non-toxic. Aside from foods labelled as organic or as free from artificial dyes, there is little objection to the use of BB at levels at or exceeding 100 μg/g in foods.This application for Misa (Metrohm Instant SERS Analyzer) is unique. The benefit is twofold — successful detection of a fluorescent dye, and a unique sample cleanup technique that permits detection of a target that does not exhibit a strong SERS signal and is present in a complex matrix. While Misa successfully detects BB in direct sampling, this application describes a simple extraction method that improves detectability of BB with Misa.
- AN-RA-010SERS detection of pesticides using screen-printed electrodes
EC-SERS enhances Raman sensitivity using electrochemically activated gold SPEs, enabling rapid, simplified pesticide detection without complex prep or instrumentation.
- AN-RA-003In situ, fast and sensitive: Electrochemical SERS with screen-printed electrodes
Substrates for surface-enhanced Raman spectroscopy (SERS) are typically fabricated with complex (micro/nano)structures of noble metals, enabling trace level detection of analytes. Due to the high costs and reactivity of these SERS substrates, they often have a limited shelf life. Development of new substrate materials which minimize these issues yet maintain the same performance standards is a constant concern.Screen-printed electrodes can be easily fabricated using different metallic materials with the well-established screen-printing method, leading to mass production of versatile, cost-effective, and disposable devices. In this Application Note, the feasibility of using readily-available screen-printed metal electrodes as suitable substrates for the fast and sensitive detection of different chemical species by in situ electrochemical SERS (EC-SERS) is shown.
- WP-026Surface Enhanced Raman Scattering (SERS) – Expanding the Limits of Conventional Raman Analysis
Surface Enhanced Raman Scattering or SERS is an anomalous enhancement of Raman scattering when molecules are adsorbed to gold or silver nanoparticles – this enhancement can be as large as 107. The advantage of SERS for the analytical chemist lies in its ability to detect analyte concentrations of parts per million and even parts per billion levels, while classical Raman is limited to parts per thousand. Metrohm Raman produces P-SERS assays in the form of nanoparticles printed onto substrates using inkjet technology. This method produces inexpensive test strips that exhibit exceptional stability and sensitivity. There are two markets that can be easily addressed with P-SERS: forensic analysisand food safety. This white paper explains the mechanism of SERS and how it can be applied to handheld Raman analysis with Metrohm Raman Mira systems.
- AN-RA-008Easy detection of enzymes with the electrochemical-SERS effect
Low sensitivity has limited the use of Raman spectroscopy as a detection method. However, the surface-enhanced Raman scattering (SERS) effect has improved its effectivity for analytical use. Aldehyde dehydrogenase (ALDH) and cytochrome c are analyzed by Raman spectroelectrochemistry as a proof of concept in this Application Note.
- AN-RS-033Raman and SERS identification of YABA, a popular street drug
Yaba, produced in Southeast Asia, is a popular drug of abuse and is actively targeted by police squads. Two strong and highly addictive stimulants make up Yaba: caffeine, which comprises up to 60% of each tablet, and methamphetamine at approximately 20%. Identifying these two active ingredients in different proportions in a colorful tablet with other excipients could be an analytical nightmare. With handheld Raman, bulk material identification is achieved in seconds onsite with simple point-and-shoot analysis. SERS (surface-enhanced Raman spectroscopy) analysis is used to detect the minor component in mixtures without interference from fillers, dyes, and coatings. MIRA DS is uniquely capable of both analyses—Raman testing positively identifies caffeine in Yaba, while methamphetamine can be detected with SERS sampling. This application describes quick, dual analysis of Yaba tablets with MIRA DS.
- AN-RA-006New strategies for obtaining the SERS effect in organic solvents
Many electrochemical methods have been developed but are traditionally limited to aqueous media. Raman spectroelectrochemistry in organic solutions is an interesting alternative, but developing new EC-SERS procedures is still required. This Application Note demonstrates that the electrochemical activation of gold and silver electrodes enables the detection of dyes and pesticides in organic media.
- AN-RS-019SERS Detection of Metanil Yellow in Turmeric
Metanil yellow (MY) is an azo dye used in the manufacture of external-use products such as textiles; however, it is prohibited from use as a food additive in many countries. Toxicology studies demonstrate that ingestion of MY results in significant neurological and multi-organ damage. Despite these hazards, MY is commonly used as an illicit colorant for enhancing the visual appeal of spices and legumes, most notably turmeric. Ideal tests for such food adulterants feature methods that are selective and sensitive, yet portable and convenient.Misa (Metrohm Instant SERS Analyzer) achieves rapid and accurate detection of MY in a facile assay format.
- AN-RS-032Raman and SERS identification of a combination prescribed opioid
Handheld Raman spectrometers are valued for their ability to provide onsite material identification in seconds. In the case of combination pharmaceuticals, a single tablet contains more than one active ingredient in different proportions. MIRA DS is uniquely capable of identifying multiple compounds in such tablets by using Raman to identify the major component and SERS (surface-enhanced Raman spectroscopy) for the minor component. This application describes quick, dual analysis of a prescription medication containing acetaminophen and hydrocodone. The application is easily extrapolated to the study of street drugs.
- WP-085Improved antioxidant monitoring of in-service industrial lubricants
Voltammetry (VA) is a fast and established method for testing the remaining antioxidant content in industrial lubricants. The flexible and modular Metrohm VA system setup discussed in this White Paper delivers more repeatable and more reproducible results which fulfill all ASTM requirements. Additionally, users can automate the complete analysis process which makes it possible to run series of samples completely unattended.
- WP-022In situ SERS effect with screen-printed silver electrodes
In this work, time resolved Raman spectroelectrochemistry measurements with screen printed electrodes are shown. The instrument used combines in a totally integrated box: a 785 nm laser source, a high resolution Raman spectrometer and a bipotentiostat/galvanostat. Experiments are controlled with an excellent spectroelectrochemical software which allows real time data collection and useful data treatment.
- WP-097Why switch to OMNIS Client/Server (C/S)?
OMNIS Client/Server boosts business performance with scalable server management, cutting costs by reducing hardware, energy use, and maintenance across locations.
- 410000055-AThe Importance of Relative Intensity Correction of Raman Data and How to Utilize it for i-Raman Series Portable Raman Instruments in BWSpec Software
An important aspect of collecting Raman data to make it comparable across instruments is correcting for the spectrometer’s relative intensity, since the relative response for each Raman spectrometer is unique. Standard reference materials (SRMs) are optical glasses that emit a broadband luminescence spectrum when illuminated with a Raman laser at a specific wavelength. This spectrum is applied as the spectral-intensity response correction for a specific instrument, to remove instrumental artefacts. The standard software for i-Raman series portable instruments, BWSpec, has functions for applying this instrument-specific correction. This technical note explains the relative intensity correction, and how to apply it using BWSpec software.
- WP-040Benefits of Client-Server Systems for Quality Control with Vis-NIR Spectroscopy
Analyzer systems monitoring product quality can offer substantial advantages when organized in a client-server network compared to the more traditional local installation. This white paper presents different client-server setups and their benefits. Security aspects that need to be considered are discussed based on the example of the client-server Vis-NIR (visible near-infrared) spectroscopy software Vision Air, widely used for quality control in the chemical, polymer, pharmaceutical, and petrochemical industry.
- 410000048-AA-Mode: Customizable Library Capabilities for Advanced Users with the TacticID®-GP Plus Handheld Raman System
The TacticID®-GP Plus has multiple measurement modes to support safety and security users. A-Mode allows the user to create library Raman or SERS spectra customizable for spectral search range and hit quality index (HQI) threshold. A-mode is of beneficial use to forensics laboratories that would like to utilize expansion of SERS detection of designer drugs specific to their geographical regions or for food safety in perspective markets. In this example, A-Mode is used to create a SERS library of melamine to easily detect the presence of melamine in infant formula using a single indicator peak.
- AN-P-063Mannitol, rhamnose, lactulose and lactose in blood serum with pulsed amperometric detection (PAD)
The lactulose/rhamnose (L/R) intestinal permeability test is used for the diagnosis of dysfunctional intestinal permeabilities. This test comprises the determination of mannitol, rhamnose, lactose and lactulose in addition to the usual blood sugars, e.g. glucose, galactose and saccharose. This Application Note presents the analysis of a blood plasma sample enriched with the four sugars mentioned above.Key word: leaky gut syndrome
- AN-RS-036Trace Detection of Toxic Dye in Saffron
SERS (Surface-Enhanced Raman Scattering) detection of a toxic dye (Sudan 1) used to adulterate saffron demonstrates the power of MISA (Metrohm Instant SERS Analyzer) for simple, portable food authentication in this Application Note.
- AN-RS-051Rapid detection of illegal adulterants in dietary supplements with Raman
Undeclared drugs in dietary supplements pose serious health risks. Metrohm’s SERS solutions enable fast, sensitive, on-site detection of adulterants without matrix interference
- 410000012-A01Rapid Detection of the Low Dose API in Xanax Using Surface-Enhanced Raman Spectroscopy for Anti-Counterfeiting Purposes
The emergence of counterfeit prescription drugs has become a concern for the pharmaceutical industry. Because of the low concentrations of APIs found in pharmaceutical drugs, normal Raman spectroscopy is typically not sensitive enough to detect the API from the surface of a pill. In this study we develop a surface-enhanced Raman spectroscopy (SERS)-based approach to identify a low-dose of the API alprazolam in a Xanax tablet using a handheld Raman spectrometer. If no SERS peaks consistent with alprazolam are observed from a Xanax tablet, the pill is a suspected fake. The method demonstrates the power of SERS to quickly verify the presence of alprazolam in the tablet for anti-counterfeiting purposes.
- WP-034Determination of Heroin in Street Drug Samples
Printable Surface Enhanced Raman Scattering (P-SERS) silver substrates were used with Metrohm Raman’s Mira DS handheld Raman analyzer to successfully detect heroin in 18 crude street heroin samples. Detection of heroin with P-SERS was accomplished easily and very quickly, with minimal sample clean-up. Solvent studies were also implemented to determine the optimal solvent for crude sample extraction, with results included here.
- AN-RS-035Fentanyl in the Mail
Raman analysis of fentanyl-soaked paper, SERS detection range for fentanyl on paper, and real-world example of fentanyl identification.
- AN-RS-030Trace Detection of Fenthion in Olive Oil
Fenthion is a multi-purpose insecticide used in many countries for mosquito control. To minimize human exposure and the unintentional poisoning of wildlife, the US EPA has classified fenthion as a restricted-use insecticide. However, the widespread spraying of olive orchards in Mediterranean countries results in olive oils that occasionally exceed the maximum residue limits established for olives.Misa (Metrohm Instant SERS Analyzer) easily achieves sensitive trace detection of fenthion in spiked olive oil after a simple organic solvent extraction. This Application Note presents an excellent example of how the signal from SERS substrates can compete with the target signal at very low levels of detection.
- AN-RS-050Trace detection of mercaptans in fuel
Mercaptans in fuels are corrosive and regulated at trace levels. SERS enhances Raman signals to enable their accurate detection and quantification below standard LODs.
- AN-RS-029Trace Detection of Malathion on Corn
Malathion is an insecticide widely used on a broad spectrum of plant species. Several studies have implicated chronic exposure to malathion in the development of certain cancers. Maximum residue limits for malathion have been enacted by the regulatory agencies of several countries: the US Food and Drug Administration sets maximum residue limits at 8 μg/g in foods, while the EU has a considerably more stringent limit of 20 ng/g.SERS is an accepted method for detection of malathion on fruit and vegetable surfaces. Misa (Metrohm Instant SERS Analyzer), which requires minimal laboratory chemicals and consumables and provides an extremely user-friendly interface, is an excellent SERS solution for trace detection of food adulterants.
- 410000009-ARapid Identification of Heroin with Handheld Raman
Raman spectroscopy is used widely by law enforcement as a field screening tool due to its speed, selectivity and ease of use. The majority of materials can be identified by the Raman signature, as they exhibit sharp distinctive peaks serving as a molecular fingerprint. However, many street and real-world samples are dark in color and not pure. The dark color, often due to impurities, gives rise to fluorescence that interferes with the Raman measurement. One method to suppress the fluorescence of a sample and enhance the Raman activity / signal is by the use of Surface-Enhanced Raman Spectroscopy (SERS).
- AN-RS-039Trace Detection of Acetamiprid on Raisins
In this Application Note, MISA (Metrohm Instant SERS Analyzer) from Metrohm Raman excels in the detection of the pesticide acetamiprid on commercially sold raisins. MISA is a viable alternative to analytical laboratory testing in the quest to prevent contaminated foods from reaching and harming consumers.
- AN-RA-007Enhancement of Raman intensity for the detection of fentanyl
Fentanyl, a powerful synthetic opioid, is illegally distributed worldwide. Overdosing can be fatal, causing symptoms like stupor, pupil changes, cyanosis, and respiratory failure. Just 2 mg of fentanyl can be lethal, depending on factors like body size and past usage. Given its severe impact, identifying and detecting fentanyl is crucial, as it has become a major public health crisis. Combining electrochemical surface-enhanced Raman spectroscopy (EC-SERS) with screen-printed electrodes (SPEs) offers a fast, effective, and precise method for detecting fentanyl.
- AN-RS-016Trace Detection of Potassium Ferrocyanide in Table Salt
Potassium ferrocyanide (KFC) is an anti-caking compound added to table salt. Although this is a common non-toxic food additive, its spectroscopic response is representative of analogous cyanide compounds. Trace detection of other cyanides in food products is essential to the safety of consumers, as they can be toxic at oral consumption levels as low as 20 μg/g.This application demonstrates rapid trace analysis of potassium ferrocyanide in table salt with Misa (Metrohm Instant SERS Analyzer), in a simple assay format with minimal use of laboratory reagents.
- AN-RS-024Trace Detection of Pyrimethanil in Wine
Pyrimethanil is a broad-spectrum fungicide. As grapevines are susceptible to fungal pathogens, large-scale viticulture operations apply pyrimethanil as part of a mixed treatment. Although chemical analysis of wines post-fermentation finds low to undetectable amounts of residue, pyrimethanil is a suspected human carcinogen. The US FDA and EU have therefore established a maximum permissible level of 5 μg/mL pyrimethanil in finished wine products.In this application, trace detection of pyrimethanil in wine with Misa (Metrohm Instant SERS Analyzer) requires few laboratory supplies and minimal sample processing, yet returns rapid results.
- AN-RS-020Trace Detection of Auramine O in Curry Powder
Auramine O (AO) is an industrial dye used for a broad range of manufactured products and as a fluorescent stain for detecting acid-fast bacteria in clinical specimens. Due to its intense yellow coloration, AO is also prized as an additive for enhancing the visual appeal of illicitly processed food products. Despite bans on AO as a food additive, surveillance testing indicates its persistent use as an adulterant in foods and spices.Misa (Metrohm Instant SERS Analyzer) achieves the rapid and sensitive detection of AO in curry powder in a simple assay format.
- AN-RS-027Trace Detection of Thiram on Apples
Thiram is used extensively as a fungicide and parasiticide to prevent disease in crops and as an animal repellent to protect trees and ornamental plants. However, extensive toxicological studies conclude that chronic, high-level exposure can cause considerable organ damage to land and aquatic species. The US defines maximum residue limits that vary for different food crops. In contrast, the EU recently banned thiram and is moving to use pesticides that carry reduced health risks.Using Misa (Metrohm Instant SERS Analyzer), low level detection of thiram on apples is achieved with guided workflows adapted for use by diverse testers.
- AN-RS-014Trace Detection of Rhodamine B in Cayenne Powder
Rhodamine B is a dye utilized extensively in biotechnology and industrial applications and is one of several colorants banned for use as food additives in Europe and North America. The most common analytical methods for detection of illicit dyes in food products, GC/MS and HPLC, are laboratory-based instrumental methods that require specialized training.With Misa (Metrohm Instant SERS Analyzer), detection of trace amounts of Rhodamine B in ground cayenne pepper is quick and easy after a facile extraction procedure with minimal material consumption. Rhodamine B can be detected in cayenne powder at a concentrations as low as 10 µg/g.
- AN-RS-022Trace Detection of Carbendazim on Strawberries
Carbendazim (MBC) is a common fungicide approved for regulated use in agriculture globally, outside of the EU. Most MBC is found on fruits as surface contamination, the result of sprays applied prior to harvest. The US EPA has determined that a concentrations below 80 μg/mL in orange juice are not a health risk, while the EU restricts MBC levels to 10 ng/g (from imported produce) in foods intended for baby food production.This Application Note describes a very simple test for surface MBC and provides library spectra demonstrating the sensitive detection of MBC with Misa (Metrohm Instant SERS Analyzer).
- AN-RS-017Trace Detection of Thiabendazole on Bananas
Thiabendazole (TBZ) is a broad-spectrum pesticide used both as a fungicide in fruits and vegetables and for controlling parasites in animal feed. To ensure consumer safety, regulatory agencies establish maximum residue levels (MRL) for pesticide-treated crops based on their review of risk assessment studies. For bananas, which are either aerially sprayed or dipped in protectant solutions of TBZ, the US FDA reports a MRL of 3 μg/g, and the EU stipulates a MRL of 6 μg/g by weight.With Misa (Metrohm Instant SERS Analyzer), the rapid and sensitive detection of TBZ on bananas is demonstrated in formats easily adapted for food safety surveillance testing.
- AN-RS-015Trace Detection of Melamine in Dairy Products
In 2008, a scandal was discovered in China that melamine was being deliberately added to raw milk. Thousands of young children and infants that consumed formula produced from melamine-tainted milk experienced kidney damage and death. As a result, both daily intake limits and increased monitoring of melamine in dairy products were established globally.Misa (Metrohm Instant SERS Analyzer) provides quick, easy, and robust detection of melamine in a complex food matrix. As a direct test with no additional reagents, Misa’s assay format requires minimal user training, in contrast to standard analytical tests for detecting melamine, including capillary electrophoresis, GC-MS, LC-MS, and immune-based assays.
- AN-RS-021Trace Detection of Erythrosine B in Sugar
Erythrosine B (EB), also known as Red Dye #3, is a synthetic dye approved for use in candy in the US, and in pharmaceuticals and cosmetics in the EU and elsewhere. However, rodent studies suggest that ingestion of EB can promote thyroid tumor formation. EB may also be implicated as a dietary factor contributing to hyperkinesis in children. WHO recommends a daily intake of EB less than 0.1 mg/kg of body weight.The ability to obtain fast results with a portable test platform recommends Misa (Metrohm Instant SERS Analyzer) as a competitive and cost-effective alternative to laboratory technologies (e.g., CE, HPLC) currently employed for detecting EB in foodstuffs.
- AN-RS-018Trace Detection of Malachite Green in Stream Water
Malachite green (MG) is a textile dye with effective fungicidal properties, however it is acutely toxic and its metabolites persist in the flesh of fish and mammals, making it a threat to the human food chain. The EU has concluded that contaminated foods containing levels higher than 2 μg/g MG constitute a credible health risk, and several countries have banned malachite green as an aquaculture additive. Despite tight regulation, seafood products contaminated with MG continue to find their way to consumers.Using Misa (Metrohm Instant SERS Analyzer) to ensure food safety, the rapid and highly sensitive detection of malachite green is achieved in a facile assay format.
- AN-RS-023Trace Detection of Aspartame in Beverages
Some studies suggest that consumption of the artificial sweetener, aspartame, is correlated with increased risk for brain and hematopoietic cancers, however, others find it to be a safe food additive. Consequently, the US and EU approve aspartame as a multi-purpose sweetener with an acceptable daily intake of 40 mg/kg body weight/day. However, the clear health hazard to individuals suffering from phenlyketonuria and ongoing criticism by health food advocates continues to fuel the challenge against aspartame’s widespread use in the food industry.Using Misa (Metrohm Instant SERS Analyzer), beverage products are screened for aspartame levels with no sample preparation beyond simple dilution of a consumer product.
- BWT-4909The Use of Raman Spectroscopy in the Field of Cancer Diagnostics
Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are proving to be invaluable tools in the field of biomedical research and clinical diagnostics. Raman systems are also being developed for molecular diagnostic testing to detect and measure human cancer biomarkers. This review highlights two applications realting to breast cancer and pancreatic cancer diagnosis together with examples of the use of Raman spectrometry in biomedical research areas such as the identification of bacterial infections, showing that Raman is an important part of the medical toolbox, as we continually strive to improve diagnostic techniques and bring a better health care system to patients.
- AN-RS-026Trace Detection of Diphenylamine in Baby Food
Diphenylamine (DPA) is used as a dye fixative and antioxidant in industrial applications and as a produce preservative in agricultural operations. Food safety advocates are concerned that daily ingestion of DPA, particularly in foods meant for babies, could have negative effects on children’s health. To mitigate potentially toxic effects of DPA, both the US and EU stipulate a maximum residue limit (MRL) of 5 μg/g for whole pears and a stringent MRL of 10 ng/g for all processed baby foods.Misa (Metrohm Instant SERS Analyzer) provides a user-friendly and cost-effective alternative to traditional analytical methods used for detecting DPA in foods, such as GC-MS and GC-NPD.
- 410000054-ATechnical Note: Method Development with NanoRam®-1064
Although the process of building, validating and using a method is well-defined through software, the robustness of the method is dependent on proper practice of sampling, validation, and method maintenance. In this document, we will detail the recommended practices for using the multivariate method with NanoRam-1064. These practices are recommended for end users who are in the pharmaceutical environment, and can expand to other industries as well. This document aims to serve as a general reference for NanoRam-1064 users who would like to build an SOP for method development, validation and implementation.
- AN-C-158Column stability of the Metrosep C 6 - 250/4.0 with Inline Ultrafiltration and Inline Eluent Preparation
The column stability of the Metrosep C 6 - 250/4.0 was determined in long-term laboratory tests. Two injection series per day were run on each of six days in a row. Each series was comprised of nine tap water injections, three check standard injections and six tap water injections. The IC system was shut down on the seventh day of each series. As a whole, the system ran over 10 weeks and counted a total of 2,150 injections. The results show an outstanding reproducibility and verify the high column stability.
- AN-S-335Column stability of the Metrosep A Supp 5 - 250/4.0 after Inline Ultrafiltration and Inline Eluent Preparation
The stability of the Metrosep A Supp 5 - 250/4.0 column was determined in long-term laboratory tests. Two injection series each were run on six days in a row. Each series was comprised of nine tap water injections, three check standard injections and six tap water injections. The IC system was shut down on the seventh day of each series. As a whole, the IC system ran over 10 weeks and counted a total of 2,150 injections. The results show an outstanding reproducibility and verify the high column stability.
- AN-S-332Column stability of the Metrosep A Supp 5 - 250/2.0 with Inline Ultrafiltration and Inline Eluent Preparation
The column stability of the microbore version of the Metrosep A Supp 5 - 250/2.0 was determined in long-term laboratory tests. Two injection series each were run on six days in a row. Each series was comprised of nine tap water injections, three check standard injections and six tap water injections. The IC system was shut down on the seventh day of each series. As a whole, the IC system ran over 12 weeks and counted a total of 2,650 injections. The results show an outstanding reproducibility and verify the high column stability.
- AN-S-033Five anions in surface water (nitrite with ELCD)
Determination of fluoride, chloride, nitrate, phosphate, and sulfate in surface water using anion chromatography with conductivity detection after chemical suppression; nitrite with electrochemical detection (conductivity and ELCD detectors in series).
- AN-V-220Remaining Useful Life of lubricants
Testing of in-service lubricating oils for their remaining antioxidant content is critical for capital equipment uptime as well as reducing running costs and repair expenses. Test methodologies such as RPVOT (rotating pressure vessel oxidation test) are time consuming and expensive to perform. Remaining Useful Life is a proven voltammetric method for testing the remaining active antioxidant content in minutes. Depending on the electrolyte, aromatic amine and phenolic antioxidants or hindered phenolic antioxidants can be determined.For the first time, a fully automated system is demonstrated, showing dramatically improved repeatability of data for confidence in reporting. Operator time is saved during sample preparation and irreproducible manual interpretation is eliminated via completely autonomous software processing. The user adds the sample into the vials, then the determination process of the sample series (including sample preparation and result calculations) is carried out automatically. The system is based on methods ASTM D6810, ASTM D6971, ASTM D7527, and ASTM D7590.
- AN-S-267Anions in an E85 mixture (85% Ethanol and 15% gasoline) by means of Inline Matrix Elimination
Determination of fluoride, acetate, formate, chloride, nitrite, nitrate, phosphate and sulfate in an E85 mixture (85% ethanol and 15% gasoline) by means of anion chromatography with conductivity detection and sequential suppression. The Inline Matrix Elimination serves as sample preparation.
- AN-COR-010Electrochemical Corrosion Studies of Various Metals
Corrosion of metals is a problem seriously affecting not only many industrial sectors, but also private life, resulting in enormous costs. In this application note, the results gained during electrochemical corrosion studies on different metals are compared to literature data.
- AN-AUT-003Automated sample handling and analysis with NOVA: High-throughput electrochemistry
The Metrohm 858 Professional Sample Processor is a robotic liquid handling system capable of handling large series of samples automatically. This instrument provides a platform that can be directly controlled by the NOVA software and combined with the Autolab potentiostat/galvanostat for automated high-throughput electrochemical measurements.
- AN-P-072Carbohydrates in orange juice applying pulsed amperometric detection
Besides the typical sugar components, orange juice contains inositol. This sugar alcohol serves as an important signaling and messenger molecule. This Application Note shows the determination of inositol besides glucose, fructose, and sucrose in orange juice on a Metrosep Carb 2 - 150/4.0 column with pulsed amperometric detection (PAD).
- AB-213Determination of nicotinamide by polarography
This Application Bulletins describes the determination of nicotinamide (vitamin PP), a vitamin of the B series. Instructions for the determination in solutions (e.g. fruit juice), vitamin capsules and multivitamin tablets are given. The linearity range of the determination is also specified. The limit of detection is approximately 50 μg/L nicotinamide.
- WP-088Simplified analysis of dairy products with Metrohm Inline Dialysis
This White Paper compares automated Inline Ultrafiltration and Inline Dialysis to the traditional Carrez clarification procedure for the analysis of milk samples by ion chromatography (IC). A continuous test series over approximately six months proved Inline Dialysis to be a reliable and valuable alternative to treat dairy products prior to IC analysis.
- AB-215Determination of folic acid by polarography
This Application Bulletin describes the polarographic determination of folic acid, a vitamin of the B series, also known as vitamin B9 or vitamin BC. Instructions for the determination in solutions (e.g. fruit juice), vitamin capsules and multivitamin tablets are given. The linear range of the determination is also specified. The limit of detection is approx. 75 µg/L folic acid.
- WP-014High productivity and profitability in IC environmental analysis
Brad Meadows is Vice President and Lab Director at the US company BSK Labs, which runs a number of environmental laboratories and service centers. Brad is an analytical chemist and has been working in the management of analysis laboratories for 15 years. He shared his experiences with Metrohm ion chromatography with us in the form of some concrete facts and figures.
- AN-CS-021Sodium in sodium bicarbonate and sodium phosphates compounded injections
Compounded injections of sodium bicarbonate are sterile solutions for correcting metabolic acidosis and other conditions requiring systemic alkalinization. Compounded injections of sodium phosphates serve as a phosphate source to either prevent or correct hypophosphatemia in patients with restricted oral intake. Ion chromatography (IC) with suppressed conductivity detection is the standardized way to accurately quantify sodium in these solutions.
- AN-V-228Thallium in drinking water
Presence of thallium in surface water is an indicator of industrial effluents and poses a serious health hazard if imbibed. Monitoring of thallium concentration can easily be done with anodic stripping voltammetry on the silver film modified scTRACE Gold. This non-toxic method allows the determination of thallium concentrations between 10–250 µg/L and can be carried out with the 946 Portable VA Analyzer.
- AN-S-338Inline Ultrafiltration with Dosino backflush for highly contaminated tannery effluent
Inline Ultrafiltration is a proven sample preparation technique for samples that are slightly or massively contaminated with particles, algae or bacteria. Filtration and injection are coupled and fully automatic. As a rule, 100 or more samples can be filtered through a single membrane. Service life is extended – even with highly contaminated tannery effluent – to more than 300 injections because the filter membrane is rinsed again once more after the analysis with the aid of the Dosino backflush.
- AN-NIR-092Quality Control of PVC foils
PVC (polyvinyl chloride) foils with a PVDC (polyvinylidene chloride) coating are often used for high performance packaging films like pharmaceutical blister packs or in food packaging. In multi-layer blister films, the PVC serves as the thermoformable backbone structure, whereas the PVDC coating acts as a barrier against moisture and oxygen. The Water Vapor Transmission Rate (WVTR) and Oxygen Transmission Rate (OTR) are influenced by the composition and the thickness of the coating. A fast way to monitor PVDC coating thickness is with near-infrared spectroscopy. Results are provided in a few seconds, indicating when adjustments in the polymer production process are necessary.
- AN-T-086Vitamin C in orange juice
Vitamin C, also known as ascorbic acid or L-ascorbic acid, is an essential nutrient involved in the repair of tissues and the enzymatic production of certain neurotransmitters. It is required for the functioning of several enzymes and immune performance, and is also an important antioxidant. This nutrient is found in many foods and is often used as a dietary supplement.This Application Note describes the photometric determination of ascorbic acid according to the standard ISO 6557-2. To increase the objectivity on the determined equivalence point and the reproducibility of the results, an autotitrator equipped with a photometric sensor, the Optrode, is used. The titrant 2,6-Dichlorophenol-indophenol (DCIP or DPIP) simultaneously serves as titrant and indicator.
- 8.000.6045Trace-level aliphatic amines in cationic pharmaceutical ingredients
The analytical challenge treated by the present work consists in detecting sub-ppb concentrations of low-molecular-weight amines in the presence of strongly retained cationic drugs by using ion chromatography (IC) with upstream inline coupled-column matrix elimination (CCME). In contrast to direct-injection IC, where the late elution of strongly retained drugs requires eluents with added acetonitrile, the CCME technique uses two preconcentration columns in series. In an «inverse matrix elimination step, cationic drug and target amines are trapped on a high-capacity and a very-high-capacity preconcentration column, respectively. During amine determination, a rinsing solution flushes the drug to waste. This significantly shortens the analysis time and improves sensitivity as well as selectivity. Besides the determination of monomethylamine in Nebivolol hydrochloride discussed here, the CCME technique is a promising tool for detecting further low-molecular-weight amines in a wide range of drugs.
- AB-073Polarographic analysis – half-wave potentials of organic substances
This Bulletin is a supplement to Application Bulletin no. 36 (Half-wave potentials of inorganic substances) in the sense that the half-wave potentials of 100 different organic substances are listed. At the same time the supporting electrolytes used and the limits of determination are given.The various substances are listed in alphabetical order. The most important polarographically active functional groups are taken into consideration. This means that substances for related structures can also be determined polarographically in the same or similar supporting electrolytes, although they may not appear in the list.Unless otherwise stated, the half-wave potentials refer to a temperature of 20 °C, and the potentials are given in volts, measured with a sat. KCI-Ag/AgCl electrode assembly.The determination limits give the smallest concentrations which can be measured without risking serious errors in the results. In all cases, the limit of detection lies below the limit of determination.
- AN-T-096Acid number in lubricants with potentiometric titration
Fresh as well as used petroleum products may contain acidic components as additives or degradation products. The acid number (AN) is a measure for the relative amount of acids present expressed as mg KOH per g sample. Moreover, AN is used as a quality parameter of lubricating oils both for assessing the quality of new formulations and as an indicator for the degradation of such formulations during service. The use of a pH electrode suitable for non-aqueous titrations ensures the reliable determination of the equivalence point. A flexible sleeve diaphragm facilitates its cleaning especially after use in heavily contaminated samples, such as in used engine oils. Using the correct electrode greatly increases the precision and reliability of the results. This Application Note describes the potentiometric determination of the acid number according to ASTM D664 and IP 177 using the pH electrode Solvotrode easyClean.
- 8.000.6026Determination of the water content in tablets by automated Karl Fischer titration
The water content of tablets determines the release of their active ingredients as well as their chemical, physical, microbial and shelf-life properties. Accordingly, the water content is of crucial importance and has to be accurately determined. This paper describes the straightforward determination of the water content using automated volumetric Karl Fischer titration (KFT). Tedious sample preparation steps are eliminated by using a high-frequency homogenizer that additionally serves as a stirrer. Prior to titration, the homogenizer comminutes the tablets directly in the KF solution. As the comminution process takes place directly in the hermetically sealed titration vessels, interference from atmospheric humidity does not occur. Even after 24 h in the vessels, the moisture content of four different tablet type samples was within 93…108% of the initially determined values. With a coefficient of determination of 0.99993 the KF method is highly linear for water amounts between 4 and 215 mg. For all investigated tablet types, KFT provides results that lie within the range expected by the manufacturer.
- AN-H-103Determination of Calcium and Magnesium in Milk
A measured amount of milk is treated with trichloroacetic acid to coagulate milk solids and liberate calcium and magnesium as dissociated ion. The coagulated milk is filtered or centrifuged, and an aliquot of the clear serum is titrated with a standard solution of 1 mol/L tetra-sodium EDTA to thermometrically determined endpoints for Ca and Mg. Acetylacetone is added to alter the Ca- and Mg- EDTA stability constants for better endpoint sharpness.
- AB-250Polarographic determination of diazepam in body fluids and pharmaceutical preparations
Diazepam belongs to the 1,4-benzodiazepine group of compounds, which are used for medical purposes as tranquilizers and antidepressants. This Bulletin describes the determination of diazepam in tablets and body fluids (blood, serum, urine) by means of differential pulse polarography. If a Britton-Robinson buffer pH = 2.8 with a methanol volume fraction of 20% is used as the supporting electrolyte then a pronounced reduction peak is obtained at -0.73 V; this allows diazepam concentrations even below 0.05 µg/mL to be determined in blood. The necessary sample preparation steps are also dealt with in this Bulletin.
- 410000031-ARapid Field Testing of Ecstasy Pills Using a 1064-nm Handheld Raman Device
B&W Tek’s TacticID®-1064 is a field-ready handheld Raman system utilizing 1064-nm wavelength laser excitation. Designed for forensic analysis by safety personnel, first responders, and law enforcement personnel, the TacticID-1064 significantly reduces fluorescence, allowing users to identify tough street samples such as ecstasy tablets in a variety of colors and mixture forms.
- 410000001-CChoosing the Most Suitable Laser Wavelength For Your Raman Application
Raman instrumentation can use lasers of different laser excitation, giving the same Raman spectrum for a sample. This paper presents the specific strengths and weaknesses that different excitation wavelengths provide, allowing a user to optimize the measurement of different samples by their choice of Raman excitation laser wavelength.
- 410000014-BRaman Spectroscopy as a Tool for Process Analytical Technology
This article demonstrates the utility of portable Raman spectroscopy as a versatile tool for process analytical technology (PAT) for raw material identification, in-situ monitoring of reactions in developing active pharmaceutical ingredients (APIs), and for real-time process monitoring. Raw material identification is done for verification of starting materials as required by PIC/S and cGMP, and can be readily done with handheld Raman. Portable Raman systems allow users to make measurements to bring process understanding and also provide proof of concept for the Raman measurements to be implemented in pilot plants or large-scale production sites. For known reactions which are repetitively performed or for continuous online process monitoring of reactions, Raman provides a convenient solution for process understanding and the basis for process control.
- 410000035-AB&W Tek TacticID for Narcotics Identification
Forensics testing of samples encountered by law enforcement and customs agents is based on analytical techniques that are now being miniaturized and simplified and are making their way into field instrumentation. Field testing with Raman spectroscopy allows users to conduct reliable measurements at the point of arrest, reducing the burden on crime labs and accelerating the prosecution process.
- 410000047-ANanoRam-1064 Fast Fact: Raw Material Verification of Cellulose and its Derivatives
Cellulose is a common naturally-derived raw excipient found in the majority of pharmaceutical products. Raw material testing is required to ensure that consumers are receiving quality cellulose and its derivatives. The NanoRam®-1064 is an asset for pharmaceutical identity testing, minimizing fluorescence generated by typical handheld Raman systems with 785 nm lasers. As such, the NanoRam®-1064 is used here to identify cellulose derivatives that would normally fluoresce with a 785 nm laser.
- AB-264Titrimetric methods for the determination of betains
The two potentiometric titration methods described here allow the determination of the content of commercial betaine solutions. Neither method is suitable for determining the betaine content of formulations. The possibilities and limits of both methods are described and distinctive features and possible sources of interference are mentioned. The Bulletin explains the most important theoretical principles and is intended to help users to develop their own product-specific titration methods.
- AN-K-052Determination of the water content in sodium acetate with MATi 10
In this application note, Karl Fischer titration is used to determine water content in sodium acetate trihydrate. The MATi 10 allows this determination to be automated, saving users time in the laboratory.
- AN-NIR-112Intrinsic viscosity (IV) determination of recycled PET by NIR spectroscopy
Near-infrared (NIR) spectroscopy is able to determine the intrinsic viscosity of rPET in less than one minute without any sample preparation. This Application Note demonstrates that the Metrohm DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) offers users an easier way to perform this analysis without the use of toxic chemicals.
- AN-PAN-1040Ammonia in cooling water of thermal power plants
Thermal power plants require enormous amounts of water, using high purity steam at high pressure to rotate turbines. A separate cooling water circuit is implemented, which helps to form a vacuum when the steam condenses after the turbines. Maintaining this vacuum with optimal condensation parameters is critical for the power plant efficiency. The copper condensers are susceptible to corrosion by ammonia, leading to an upper limit of 2 mg/L NH3 set by EPRI in cooling water. Small cracks in the condenser combined with the large pressure differential between the steam circuit and the cooling water circuit will contaminate the high purity water in the boiler, causing major problems and necessitating a shutdown for plant maintenance. Monitoring NH3 online in cooling water with a process analyzer can signal early problems in a plant before significant intermediation is necessary.
- AN-RS-031Simplified RMID Model Building
Material verification models with complex algorithms such as Principal Component Analysis (PCA), quasi-infinite parameters, and preprocessing options can be incredibly complex. Each model must be rigorously built, evaluated, and validated before it can be put into routine use. Mira P simplifies material verification for all. With a short, defined user workflow, straightforward results, and a foolproof Operating Procedure-based design, Mira P is already one of the simplest RMID tools available. ModelExpert, in Mira Cal P, does a chemometrician’s work. ModelExpert automatically determines the best model parameters for robust method development. With Mira P and ModelExpert, even non-technical users can achieve better results in a fraction of the time.
- AN-T-100Chloride in acidic copper baths
Acid copper baths are mainly used for the copper deposition on semiconductor wafers. Small amounts of chloride increase the speed of deposition and reduce anode polarization. However, higher concentrations are undesired, as this will decrease the quality of the copper deposition. Therefore, it is quite important to monitor the amount of chloride to have an effective, yet high-quality copper deposition process.In this Application Note, a fully automated solution based on titration is presented. In comparison to ion chromatography, titration offers the benefit that no dilution of the sample is necessary, and the hardware is comparatively low-priced. Furthermore, the fully automated solution allows users to minimize handling errors, to reduce workloads, and to guarantee outstanding reproducibility.
- AN-V-239Iron speciation in LiFePO4 batteries
Lithium iron phosphate batteries offer users safety and durability. Polarographic speciation evaluates Fe(II) and Fe(III) in cathode material, useful for several tests.
- WP-043Instrument Calibration, System Verification, and Performance Validation for Metrohm Instant Raman Analyzers (Mira)
Analytical Instrument Qualification (AIQ) according to the United States Pharmacopeia (USP) ensures that instruments perform as intended and users may have confidence in data quality. As the Pharma industry adopts handheld Raman instruments for incoming materials identification and verification, producers of such systems must provide suitable calibration and validation routines. Upon completion of these tests, end users are assured that all measurements are in accordance with agreed standards at Metrohm Raman, we have sophisticated AIQ routines in place to confirm the quality of your results.
- WP-045When HPLC fails: IC in food, water, and pharmaceutical analysis
High-Performance Liquid Chromatography (HPLC) and Ion Chromatography (IC) are commonly used in the pharma, food, and environmental sectors to analyze samples for specific components and to verify compliance with norms and standards. However, users of HPLC may run into the limitations of this technique, e.g., when analyzing standard anions or certain pharmaceutical impurities. This white paper outlines how such challenges can be overcome with IC.
- 410000049-ANanoRam®-1064 Fast Facts: Botanical Verification
Botanicals are derived from plant materials and used for their medicinal and therapeutic properties in the nutraceuticals market. They are not as heavily regulated by the U.S. Food and Drug Administration (FDA) like the pharmaceuticals drug market, but they are required to follow Good Manufacturing Practice (GMP Requirements).The NanoRam®-1064 is an asset for pharmaceutical identity testing, minimizing fluorescence generated by typical handheld Raman systems with 785 nm lasers. As such, the NanoRam®-1064 is used here to identify botanicals that would normally fluoresce with a 785 nm laser.
- AN-NIR-124Polyethylene content determination in polypropylene pellets by NIRS
Polypropylene and polyethylene can pose recycling challenges. With near-infrared spectroscopy (NIRS), users receive polyolefin composition results in seconds.
- AN-RS-040Trace Detection of DMT in Plant Matter
Modern recreational use of DMT (N,N-Dimethyltryptamine) is growing and although it is legally protected in some countries, new legislation attempts to reduce its abuse and associated adverse health effects. MIRA XTR DS from Metrohm Raman provides rapid and sensitive detection of DMT in the field.
- AN-RS-034Orbital Raster Scan (ORS™)
This application note presents the Orbital Raster Scan (ORS) technology from Metrohm Raman to overcome low resolution, poor sensitivity, and sample degradation while still interrogating a large sample area.
- AN-RS-038Detection of LSD on blotter paper
With MISA and MIRA, easy-to-use test kits and flexible sampling allow rapid and accurate interrogation of suspect materials with minimal time, training, and expense.
- 410000013-AFast and Selective Detection of Trigonelline, a Coffee Quality Marker, Using a Portable Raman Spectrometer
Portable Raman is used to quantify trigonelline, an alkaloid that contributes to the health benefits of some foods. A simple method to quantify the presence of diluted trigonelline in solutions using surface enhanced Raman spectroscopy is described. Portable Raman is a tool that could be used in quality control of food items such as coffee and quinoa.
- AN-RS-025Trace Detection of Paraquat in Tea Leaves
Paraquat is a highly effective, yet exceptionally toxic herbicide used to manage weeds in agricultural operations. In recognition of paraquat’s danger, the EU and several other countries have banned its use for any application, though the US EPA permits its limited use by licensed applicators. Despite tight regulation, paraquat continues to be produced and is liberally used as an herbicide in over 100 countries without regulatory oversight.Testing for paraquat typically requires involved sample processing and analysis by trained chemists using expensive laboratory instruments such as HPLC, CE, and LC/MS. Misa achieves trace level detection of paraquat residue in tea leaves in a fully integrated, portable, smart system for easy on-site testing by non-technicians.
- AN-EC-033Utilizing hyphenated EC-Raman to study a model system
This Application Note presents a walkthrough of an experiment on 4-nitrothiophenol using hyphenated EC-Raman, a combination of Raman spectroscopy and electrochemistry.
- AN-RA-009Comparison of SPELEC RAMAN and standard Raman microscopes
This Application Note compares SPELEC RAMAN and a standard Raman instrument by analyzing their performance in measuring single-walled carbon nanotubes (SWCNT).
- AN-T-098Total base number according to IP test method 400
This Application Note describes the conductometric determination of the total base number in engine oil according to IP 400.
- AN-EC-041Studying nickel deposition with EQCM-D and EC-Raman
This application note demonstrates EQCM D for simultaneous mass and dissipation analysis of Ni(OH)₂ electrodeposition.
- AN-RS-044Optimize raw material identification and verification (RMID) with MIRA P
This Application Note explains how to scale MIRA P usage across an entire manufacturing operation by transferring models between different MIRA P instruments.
- EB-002NIR spectroscopy: The efficiency boost for QC labs
Enhance quality control in material and chemical production with NIRS. Fast, cost-effective, and no sample prep needed. Learn more in our eBook.
- AN-RS-045Transition RMID Operations Between Handheld Raman Devices
This application shows how to seamlessly transition from Metrohm’s NanoRam 785 to the newer MIRA P system, ensuring continuity in raw material identification (RMID).
- AN-PAN-1063Inline analysis of borate and sulfate solutions with Raman spectroscopy
Boric acid is growing in demand for various industrial applications, but requires a more cost-efficient and environmentally friendly production process. This Application Note describes the performance of a Raman process analyzer (PTRam) when measuring low-concentration boric acid and sodium sulfate solutions (<100 mg/L) during boric acid production.
- AN-EC-034Ion-selective electrodes based on screen-printed technology
Advances in polymeric membranes and screen-printed technologies have enabled miniaturized, portable potentiometric sensors ideal for point-of-care analysis.
- 410000029See-through ID with Raman technology
Metrohm’s ST Raman technology enables fast, contactless identification of substances through opaque packaging, expanding safe, field-ready use of Raman spectroscopy.
- 410000052-ASee-Through Measurements of Illicit Substances in Commercial Containers with the TacticID®-1064 ST
The TacticID®-1064 ST is a 1064 nm handheld Raman system designed for law enforcement officials, first responders, and customs and border protection officers for rapid field identification of illicit substances such as narcotics, explosives, and other suspicious materials.The TacticID-1064 ST is specially designed with see-through Raman functionality to measure materials through both transparent and opaque containers. These through-barrier measurements remove the need for active sampling of potentially dangerous compounds such as fentanyl, leading to safer operations and reduced wait time for clear results.
- AN-CIC-035Halogens and sulfur in solid samples according to EN 17813
Organic halides must be monitored in the environment. Combustion ion chromatography (CIC) is used for accurate halogen analysis in solids following EN 17813:2023.
- AN-DV-001DropView solutions for treatment of electrochemical and optical results
Electrochemistry, spectroscopy, and spectroelectrochemistry (SEC) are widely used techniques in many fields. However, the data curves obtained from these analyses are quite varied, and not all electrochemical peaks and spectroscopic bands can be measured with the same procedures. This Application Note examines four tools included in the DropView 8400 and DropView SPELEC softwares to facilitate the measurement and analysis of the collected curves and data. The following measurement options are explained in detail: automeasurement, set on curve measurement, set free measurement, and set step measurement.
- AN-EC-025Study of the hydrogen region at platinum electrodes with linear scan cyclic voltammetry
The study of the electrochemical behavior of platinum in acidic media is of crucial importance in fundamental electrochemistry and electrocatalysis. Most electrocatalytic processes occurring at Pt electrodes are highly sensitive to the structure of the platinum surface. Cyclic voltammetry (CV) is a widely used rapid measurement technique that provides both a qualitative and quantitative fingerprint of platinum surfaces. A comparison of results given by linear and staircase CVs is presented in this Application Note.
- AN-EC-026Comparison between linear and staircase cyclic voltammetry on a commercial capacitor
Capacitors are electronic components necessary for the success of the electronics industry. They have also become essential components of both electric and hybrid vehicles. Electrochemical tests, such as potentiostatic cyclic voltammetry, are used to check the performance of capacitors. VIONIC powered by INTELLO can perform both staircase and linear cyclic voltammetries (CV). This Application Note gives a comparison between the linear and the staircase potentiostatic cyclic voltammetries and highlights the necessity of using the linear CV to best study the performance of capacitors.
- AN-EC-032Hydrogen permeation with a single instrument according to ASTM G148
The Devanathan-Stachurski cell (or «H cell») is successfully used to evaluate the permeation of hydrogen through sheets or membranes. As small amounts of hydrogen pass through the sheet or membrane, a very sensitive potentiostat is required for its detection. A study of the hydrogen permeation properties of different iron sheets is discussed in this Application Note while taking the instrumental requirements into account.
- AN-FET-001Characterization and performance studies of field-effect transistors (FETs) using μStat-i 400
In recent years, field-effect transistors (FETs) have become more commonly used as a sensing platform for a multitude of electrochemical and biological applications. These devices are promising bioelectronic transducers that allow both low-potential operation and stable potentiometric measurements. FETs are now seen as an attractive alternative to using conventional electrochemical detection systems in the scientific community. This Application Note gives in-depth guidance about how to operate Metrohm DropSens bipotentiostat devices for the characterization of FETs and their use as transducers. A single μStat-i 400 device, a small and portable bipotentiostat and galvanostat, is used to demonstrate the experiments.
- AN-FLU-002Understanding the mechanism of a bioassay indicator by fluorescence
Alamar Blue is monitored with fluorescence spectroelectrochemistry during its irreversible reduction to resorufin and further reversible reduction to dihydroresorufin.
- AN-I-035Sodium content in food using an ion-selective electrode
Excess sodium intake increases the risk of health issues. Ion-selective electrodes (ISEs) offer a fast, accurate, and cost-effective method for measuring sodium in food.
- AN-I-036Sodium content in water using an ion-selective electrode
Groundwater contains many minerals, but can be contaminated by sodium-rich leachate from landfills. Accurate Na determination in water is possible following AOAC 976.25 using the Na-ISE.
- AN-NIR-073Determination of water activity in tablets with the OMNIS NIR Analyzer
Water activity is an important parameter to measure for non-sterile pharmaceutical quality and stability. The OMNIS NIR Analyzer provides this data within seconds.
- AN-NIR-103Quality control of chocolate bars by near-infrared spectroscopy
Near-infrared spectroscopy (NIRS) is a fast, chemical-free analysis method for various quality parameters of chocolate bars without sample preparation. The NIRS solution is easy to use and can be used atline or in a quality control lab.
- AN-NIR-108Measuring Brix and individual sugars in fruit juices with NIR spectroscopy
NIRS enables rapid, chemical-free analysis of glucose, fructose, sucrose, and Brix in fruit juices without sample prep, offering a fast alternative to traditional methods.
- AN-NIR-117Analysis of moisture, ash, carbon, and volatile content in coal by NIRS
Conventional methods used to analyze moisture, ash, fixed carbon, and volatile content in coal samples, are time consuming and costly. Near-infrared (NIR) spectroscopy is excellently suited to determine all parameters simultaneously in less than one minute without any sample preparation.
- AN-NIR-118Quantification of cotton content in textiles by near-infrared spectroscopy
This Application Note demonstrates how the OMNIS NIR Analyzer Solid quickly determines the cotton content in various textile products within just 30 seconds.
- AN-NIR-119Moisture content and rheology determination of fluorinated polyolefins using NIRS
Near-infrared spectroscopy streamlines ethylene tetrafluoroethylene production by offering rapid, chemical-free analysis of melt flow rate and moisture content.
- AN-NIR-122Quantification of water in lactose with the OMNIS NIRS Analyzer
This Application Note shows how easy it is to determine water content in the pharmaceutical excipient lactose with reagent-free near-infrared spectroscopy.
- AN-NIR-123Flour analysis by near-infrared spectroscopy (NIRS)
NIR spectroscopy offers fast, chemical-free analysis of ash, protein, moisture, and rheological properties in flour – ideal for routine lab or atline quality control.
- AN-NIR-130Multiparameter hops analysis by near-infrared spectroscopy (NIRS)
NIRS can simultaneously measure several quality parameters in hops like cohumulone, hop oils, and moisture content, the hop storage index (HSI), and alpha and beta acids.
- AN-NIR-132Almond analysis with near-infrared (NIR) spectroscopy
This Application Note shows how NIR spectroscopy is used to determine the water content (moisture content), protein content, and fat content in whole and ground almonds.
- AN-NIR-135Quality control of honey with NIR spectroscopy
NIR spectroscopy can measure several honey quality parameters simultaneously in just a few seconds without any sample preparation as shown in this Application Note.
- AN-PAN-1002Online monitoring of cyanide and gold in gold leaching solution
Gold leaching by cyanidation requires precise monitoring of cyanide and gold. Online process analyzers perform such measurements, improving safety and compliance.
- AN-PAN-1041Inline monitoring of free isocyanate (%NCO) content in polyurethane
Polyurethanes are a class of synthetic polymers formed by reacting liquid di/polyisocyanates and polyols with a catalyst and various additives in a reactor. Polymer properties are modified with stepwise additions of these chemicals at different points in time depending on whether the process has reached an equilibrium. NCO functional groups from unreacted isocyanates must be quenched at the end for a finished product, and this parameter must be known to determine the proper chemical mixing ratio. A fast, non-destructive real-time measurement of %NCO can be obtained by using NIR spectroscopy with a probe seated directly in the reactor.
- AN-PAN-1046Online Determination of Anions in 50% NaOH and 50% KOH by IC (ASTM E1787-16)
The basic chemicals industry is responsible for producing thousands of raw materials at very large scales. The industries downstream rely upon a certain level of chemical purity to manufacture their own goods, as certain impurities can cause major issues in various processes. During the production of the basic chemicals NaOH and KOH, electrolysis of saturated brine solutions with membrane-cells yield the product which is further concentrated by evaporation. Impurities from the salts used in the brine will also be concentrated. Typically, this impurity analysis is performed offline with various hazardous chemicals with varying shelf-lives. The Process Ion Chromatograph is able to perform the measurement described in ASTM E1787-16 online, ensuring quality product without the need for time-consuming, hazardous laboratory experiments.
- AN-RS-012Handheld Raman for Acid Attack Prevention
Acid throwing, a historical method for retribution against women, has become a modern threat of a different nature. Concentrated acids and other corrosive substances have emerged as modern tools of social violence. Aggressors use common plastic containers with openings that create a powerful directional spray, such as lemon juice squeeze bottles. Sulfuric and phosphoric acids were chosen for analysis here due to their highly corrosive nature- acid attacks in London most commonly use sulfuric, phosphoric, and nitric acids.2017 saw a remarkable number of acid attacks in the UK, with reported incidences averaging 2x a day. Detection and regulation of acids may contribute to prevention of this social scourge.
- AN-RS-013Determination of Container Contents
Identification of unknown materials in the field can be a complicated affair, especially in critical situations, where speed, safety, and ease-of-operation are essential. Mira DS, Metrohm Raman’s handheld Raman analyzer, and the intelligent Universal Attachment (iUA) give the user automated Content ID capabilities. Content ID achieves through container identification of unknown materials quickly, easily, and safely.
- AN-RS-037A Deeper Look at 785 nm Raman
Signal-to-noise ratio, spectrograph design, resolution of MIRA handheld Raman analyzers.
- AN-RS-046Through-container analysis with Raman spectroscopy
TacticID-1064 ST is a handheld Raman device that can identify materials through paper, plastic, glass, and multilayer packaging, reducing exposure risks and eliminating the need to open containers.
- AN-RS-047Rapid phenotypic identification of microorganisms with Raman
Raman spectroscopy offers a fast, nondestructive way to identify microorganisms and analyze metabolites directly from culture media, without complex genetic sequencing.
- AN-RS-048Phosphates speciation with Raman spectroscopy
Metrohm’s MIRA XTR handheld Raman spectrometer enables fast, reagent-free identification of phosphate species, enabling continuous monitoring of dynamic systems.
- AN-SEC-004Spectroelectrochemical analysis of electrochromic materials
Poly(3,4-ethylenedioxythiophene) (PEDOT) is one of the most promising ICPs due to its high conductivity, electrochemical stability, catalytic properties, high insolubility in almost all common solvents and interesting electrochromic properties (transparent in the doped state and colored in the neutral state). In this Application Note, PEDOT film is evaluated by spectroelectrochemical techniques.
- AN-SENS-002Detection of heavy metals with differential pulse voltammetry
This Application Note presents DPV as a sensitive, selective method for detecting heavy metals in water, detailing setup, parameters, and advantages over other techniques.
- AN-T-111Saponification value of edible oils
The saponification value evaluates edible oil quality by indicating the average molecular weight of fatty acids. Its titrimetric determination in canola and olive oil is described here.
- AN-T-192Determination of acid-neutralizing capacity according to USP<301>
This Application Note details the determination of acid-neutralizing capacity (ANC) in several pharmaceutical samples in compliance with USP<301> standards.
- AN-T-219pH value and TTA in flour, dough, and bread
In order to consistently manufacture high quality baked goods, it is critical to measure the pH value and acidity content in the raw materials and during the production steps. These factors have a major influence on the taste and storage lifetime of the final product. Consistent product quality is only possible with precise measurements during the process.This Application Note describes the measurement of pH value and the total titratable acidity in flour, dough, and bread using the Eco Titrator from Metrohm.
- AN-T-237Determination of phosphoric acid with sodium hydroxide
Phosphoric acid is a triprotic inorganic acid used for many purposes: as a raw material for the production of phosphate fertilizers, detergents, as an electrolyte in phosphoric acid fuel cells, rust removers, and for the passivation of iron and zinc to protect against corrosion. This Application Note presents an acid-base titration where the concentration of phosphoric acid is determined over all three of its dissociable protons by titrating it with sodium hydroxide.
- AN-T-238Determination of the alkalinity (p-value and m-value) in water
Alkalinity defines the acid-binding capacity of natural water. A distinction is made between total alkalinity (m-value) and carbonate alkalinity (p-value). This Application Note presents the determination of pH and alkalinity in water with a titration method conforming to EPA 310.1, Standard Methods 2320 B (Titration Method), ASTM D1067, EN ISO 9963-1, and EN ISO 9963-2.
- AN-T-239Nonaqueous titration of weak bases with perchloric acid
The amine value is an important parameter and quality indicator to determine in chemical processes and pharmaceuticals. This Application Note presents the nonaqueous perchloric acid titration of triethanolamine.
- AN-T-242Acidity in aviation turbine fuel according to ASTM D3242
This application presents the fully automated determination of acidity in jet fuel as per ASTM D3242 via photometric titration with an automatic titrator and the Optrode.
- AN-T-246Standardization of cationic surfactants by argentometric titration
The standardization of the cationic surfactant TEGOtrant is performed using potentiometric titration as well as near-infrared spectroscopy (NIRS) in this application.
- WP-082Measuring inorganic cations and amines with ion chromatography mass spectrometry (IC-MS)
This white paper presents IC-MS as powerful analysis technique. This multiparameter method determines various analytes such as inorganic cations and amines in one run.
- WP-092USP monograph modernization initiative leading to modern ion chromatography-based methods
The USP and FDA started to modernize several monographs and General Chapters. In many cases, IC-focused methods have replaced older, wet chemistry procedures. Learn more about the USP modernization initiative and the advantages of ion chromatography in this white paper.
- AN-EIS-004Electrochemical Impedance Spectroscopy (EIS) Part 4 – Equivalent Circuit Models
Explore how to construct simple and complex equivalent circuit models for fitting EIS data in this Application Note. Nyquist plots are shown for each example.
- AN-K-073Volumetric Karl Fischer titration with Scharlau Aquagent® reagents
Test measurements on water standards are performed with an OMNIS KF Titrator and Karl Fischer reagents Aquagent® Complet 5 and Methanol Fast from Scharlau.
- AN-EIS-001Electrochemical impedance Spectroscopy (EIS) Part 1 – Basic Principles
Electrochemical impedance spectroscopy (EIS) is a widely used multidisciplinary technique for characterizing the behavior of complex electrochemical systems. EIS is employed in the study of a range of complex systems including batteries, catalysis, and corrosion processes. This Application Note focuses on the basic principles of EIS measurements.
- AN-SENS-001Quantification of paracetamol with square wave voltammetry
This Application Note demonstrates square wave voltammetry for sensitive, reproducible quantification of paracetamol using a screen-printed electrode and INTELLO.
- AN-EIS-003Electrochemical Impedance Spectroscopy (EIS) Part 3 – Data Analysis
Here, the most common circuit elements for EIS are introduced which may be assembled in different configurations to obtain equivalent circuits used for data analysis.
- AB-405Total base number titration of petroleum products
This Application Bulletin shows the determination of the total base number in petroleum products by applying different titration types according to various standards.
- AN-S-404Water quality testing with EPA 300.1
The Metrosep A Supp 21 column and 948 Continuous IC Module, CEP enable efficient, automated single-run analysis of major anions and disinfection byproducts in water.
- AN-CIC-034Fast analysis of AOX in waters by CIC
Combustion ion chromatography (CIC) measures AOX (adsorbable organically bound halogens, i.e., AOCl, AOBr, AOI) and AOF as well as CIC AOX(Cl) according to DIN 38409-59 and ISO 18127.
- AN-C-193Alkyl amines in scrubber solutions
Harmful industrial flue gases like H2S and CO2 cause corrosion of pipes and damage the environment. Adding the correct amount of amines in scrubber solutions, e.g. ethanolamines and methylamines, will neutralize these gases («gas sweetening»). Non-suppressed cation analysis with direct conductivity detection is a straightforward and robust technique for the quantification of monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), monomethylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA) via ion chromatography. Thanks to the high capacity of the Metrosep C 6 column, large volumes can be injected without compromising the peak shapes. The analytical technique can be used at laboratory scale but also for process analysis.
- AN-P-085Iodine monitoring in natural sources
Iodine is an essential mineral for human health, where it is necessary for e.g., the production of thyroid hormones. The presented method describes the determination of free iodide in milk samples using Metrohm Low Volume Inline Dialysis for automated sample preparation prior to injection into an ion chromatograph (IC) and subsequent amperometric detection in direct current (DC) mode.
- AN-BAT-003Galvanostatic intermittent titration technique (GITT) for Li-ion batteries
This Application Note outlines GITT, a key technique for studying Li-ion battery kinetics, OCV, and diffusion, using INTELLO for streamlined control and analysis.
- AN-CIC-033Monitoring PFASs in water sources
AOF (adsorbable organic fluorine) is used to screen for per- and polyfluorinated alkyl substances in aqueous matrices via pyrohydrolytic combustion and ion chromatography.
- AN-EC-036Ohmic iR drop Part 3 – Measurement with EIS
This Application Note explains manual and automated iR drop correction with electrochemical impedance spectroscopy and cautions against using less accurate methods.
- AB-342Automated determination of calcium and magnesium in milk with thermometric titration
This bulletin deals with the automated determination of calcium and magnesium in commercially available finished milk products using a 859 Titrotherm and a 814 USB Sample Processor. Calcium and magnesium in milk can be rapidly and easily titrated thermometrically using a standard solution of Na4EDTA as titrant.Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamo (software) using the SLO command. Results are reported as mg Ca and Mg/100 mL.
- WP-050Manual titration vs. automatic titration: benefits and advantages to switching
This white paper summarizes the advantages and benefits of automated titration in comparison to manual titration. The increase in accuracy and precision of measurements as well as significant time and cost savings are discussed.
- WP-081Fast determination of AOX in waters according to DIN 38409-59
Monitor adsorbable organic halogens (AOX) in water using combustion ion chromatography (CIC) for precise analysis of AOCl, AOBr, AOI, and total AOX.
- EB-001Near-infrared spectroscopy for the analysis of petrochemicals
Improve petrochemical quality control with NIRS. Fast, cost-effective, and no sample prep needed. Learn more in our eBook.
- AN-M-017IC-MS/MS analysis of trifluoroacetic acid according to DIN 38407-53
The new DIN draft standard 38407-53 outlines TFA analysis in water using direct injection LC-MS/MS, enabling quantification from 0.1–3.0 μg/L as shown in this Application Note.
- AN-BAT-016EIS at different states of charge with INTELLO
This application shows how EIS, combined with INTELLO and NOVA, tracks changes in internal battery resistance across SOC levels to study performance and aging mechanisms.
- AN-NIR-078Automated moisture analysis in pharmaceutical peptides
The quantification of residual moisture in lyophilized pharmaceutical peptides is an important measure for quality control in the pharmaceutical industry. For development purposes, such measurements are necessary and routinely performed during stability studies and to optimize the freeze-drying process (lyophilization). Currently, Karl Fischer titration is widely used for moisture determination in routine analysis. However, this method is time consuming and destroys the sample during analysis. This Application Note shows that near-infrared spectroscopy (NIRS) is a fast, reagentless, non-destructive method to determine moisture content in lyophilized pharmaceutical products.
- AB-404Total acid number titration of petroleum products
The determination of the acid number plays a significant role in the analysis of petroleum products. This is manifested in the numerous standard procedures in use over the world (internal specifications of multinational companies, national and international specifications of ASTM, DIN, IP, ISO, etc.). These procedures differ mainly in the composition of the used solvents and titrants.This bulletin describes the determination of the acid number in petroleum products by applying different types of titration.The potentiometric determination is described according to ASTM D664, the photometric according to ASTM D974 and the thermometric titration according to ASTM D8045.
- AN-T-240Total acid number with conductometric titration
The total acid number (TAN) is an important parameter for assessing the acidity of oils and fuels. This Application Note determines TAN using conductometric titration.
- AN-T-243Sulfite determination in beet sugar
This study presents the automatic titration of low sulfite levels in beet crystal sugar using an OMNIS Titrator and a Pt Titrode as the potentiometric sensor.
- AN-V-222Iron determination in drinking water
The presence of iron in drinking water can lead to an unpleasant taste, stains, or even growth of «iron bacteria» that can clog plumbing and cause an offensive odor. Over a longer period, the formation of insoluble iron deposits is problematic in many industrial and agricultural applications. To avoid these problems, the U.S. Environmental Protection Agency (EPA) defines the Secondary Maximum Contaminant Level (SMCL) for water treatment and processing plants as 0.3 mg/L Fe in drinking water.The voltammetric determination of the iron triethanolamine complex on the non-toxic Bi drop electrode allows both the detection at very low levels (limit of detection of 0.005 mg/L) and measurements in a wide range of concentrations up to 0.5 mg/L.
- AN-V-223Nickel and cobalt in drinking water with a Bi drop electrode
The main sources of nickel pollution are electroplating, metallurgical operations, or leaching from pipes and fittings. Catalysts for the petroleum and chemical industries are major application fields for cobalt. In both cases, the metal is either released directly, or via the waste water-river pathway into the drinking water system. Therefore in the EU the legislation specifies 20 µg/L as the limit value for the Ni concentration in drinking water.The simultaneous and straightforward determination of nickel and cobalt is based on adsorptive stripping voltammetry (AdSV). The unique properties of the non-toxic Bi drop electrode combined with AdSV results in an excellent performance in terms of sensitivity.
- AN-V-227Chromium(VI) in drinking water with a glassy carbon electrode
The guideline value for chromium in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» is 50 µg/L. It should be noted here that chromium concentrations are often expressed as total chromium and not as chromium(III) or (VI). Chromium(VI) is responsible for changes in genetic material, and is found in significantly lower concentrations than Cr(III). Therefore an extremely sensitive method is required to monitor Cr(VI) in drinking water.The powerful adsorptive stripping voltammetry (AdSV) technique on the ex-situ mercury film modified glassy carbon electrode using DTPA as complexing agent can be used to determine such low concentrations.
- AN-V-237Lead stabilizer in an electroless Ni plating bath
Electroless nickel plating ensures low-cost wear and corrosion resistance. Monitoring lead stabilizer levels in Ni plating baths is possible with the Bi drop electrode.
- AN-K-07234433 HYDRANAL™ NEXTGEN Coulomat AG-FI
Karl Fischer reagents contain buffer substances (usually imidazole) since the reaction constant is dependent on the pH value. A constant pH therefore ensures the most repeatable results. In 2015, imidazole was classified by European Union the as a CMR (carcinogenic, mutagenic or toxic) substance and the statement H360D was added, stating possible harm to fertility or a fetus. Meanwhile, other reagents free of imidazole are available for purchase. This Application Note summarizes test measurements with 34433 HYDRANAL™ NEXTGEN Coulomat AG-FI.
- AN-T-236Determination of hydrochloric acid with sodium hydroxide
Hydrochloric acid is a strong, inorganic mineral acid with great significance in the chemical industry. The potentiometric titration of hydrochloric acid with sodium hydroxide is one of the most important and also most frequent analyses performed in the laboratory. In this Application Note, an acid-base titration is presented where the concentration of HCl is determined with NaOH using a pH electrode with an integrated Pt1000 temperature senor for the most accurate results
- AN-V-221Cadmium and lead in drinking water with a Bi drop electrode
To reduce the toxic effects of cadmium on the human body, as well as to limit the neurotoxic effects of lead, the provisional guideline values in the World Health Organization’s «Guidelines for Drinking-water Quality» are set to a maximum concentration of 3 µg/L for cadmium and 10 µg/L for lead. The completely mercury-free Bi drop electrode takes the next step towards converting voltammetric analysis into a non-toxic approach for heavy metal detection. Using this environmentally friendly sensor for anodic stripping voltammetry (ASV) allows the simultaneous determination of Cd and Pb in drinking water. The outstanding sensitivity is more than sufficient to monitor the provisional WHO guideline values.
- AN-V-225Cadmium and lead in drinking water with a glassy carbon electrode
To reduce the toxic effects of cadmium on the kidneys, skeleton, and the respiratory system, as well as the neurotoxic effects of lead, the provisional guideline values in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» are set to a maximum concentration of 3 µg/L for cadmium and 10 µg/L for lead.The powerful anodic stripping voltammetry (ASV) technique on the ex-situ mercury film modified glassy carbon electrode is more than sufficient to monitor the proposed WHO guidelines for Cd and Pb in drinking water.
- AN-V-224Nickel and cobalt in drinking water with a glassy carbon electrode
Due to the toxicity and the detrimental effects of nickel and cobalt on human health, their concentrations in drinking water must be controlled. Therefore, EU the legislation specifies 20 µg/L as the limit value for nickel in drinking water. The current provisional guideline value for Ni in the World Health Organization’s «Guidelines for Drinking-water Quality» is set to a maximum concentration of 70 µg/L. To monitor the concentrations of Ni and Co with the 884 Professional VA, a method for simultaneous determination on the glassy carbon electrode (GC-RDE) modified with a Bi film is used.
- AN-EC-010In-temperature ionic conductivity measurements with the Autolab Microcell HC setup
To improve the performance of electrochemical energy storage devices like batteries and supercapacitors, one can focus on enhancing the ion conductivity (ƠDC) of the electrolyte. It is a common method for obtaining ƠDC values of different electrolyte systems, to carry out electrochemical impedance spectroscopy (EIS) experiments, at different temperatures, in a 2-electrode setup.
- AN-T-247Photometric titration of acid value in biodiesel according to EN 14104
The acid value of fatty acid methyl esters (FAME) like biodiesel can be determined according to EN 14104 using photometric titration with OMNIS and the Optrode.
- AN-T-225Analysis of caffeine, pH, and acidity in coffee
Many of the key factors that influence coffee taste correlate with chemical properties that can be measured. These include pH, titratable acidity, refractive index, and caffeine. Historically, many of these analyses have included long, manual sample preparation processes using the time-consuming, liquid chromatography (LC) technique. This Application Note looks at a faster, simpler, alternative method for analysis of key quality parameters in coffee using a single titration platform: OMNIS.
- AN-R-009Oxidation stability of fatty acid methyl esters (FAME, biodiesel)
In this Application Note, the 893 Professional Biodiesel Rancimat measures the oxidation stability of biodiesel (or fatty acid methyl esters, FAME), an eco-friendly fuel.
- AN-PAN-1054Online monitoring of hydrogen peroxide during the CMP process
The planarity and smoothness of silicon wafers are fundamental to manufacture optimal semiconductor devices, and Chemical Mechanical Planarization (CMP) is the most common technology used to achieve ultra-flat surfaces. A slurry is used for this purpose, composed of deionized water, a colloidal silicon or alumina liquid dispersion, and hydrogen peroxide, which has to be constantly monitored at all times.Online monitoring of the CMP process is necessary to avoid chemical waste and enhance wafer production yields. Metrohm Process Analytics can measure not only the H2O2 concentration, but also pH, conductivity, and temperature using the multipurpose 2060 Process Analyzer.
- AN-R-034Oxidation stability of diesel, biodiesel, and blends
Sustainable biodiesel can be blended with petroleum diesel. The 893 Professional Biodiesel Rancimat measures the oxidation stability of biodiesel and its blends.
- AN-RS-056Quantification of methanol in contaminated spirits
Raman spectroscopy is ideally suited to rapidly screen for methanol contamination in spirits.
- AN-S-398Phosphate in sodium and potassium phosphates compounded injections
An ion chromatography (IC) assay with suppressed conductivity detection is the standardized way to accurately quantify phosphate in phosphates compounded injections.
- AN-S-401Nitrite in duloxetine hydrochloride API
Nitrosamine presence in medicines, even at trace level poses high safety risks to patients (carcinogenic). Nitrosamine formation can be avoided by controlling and monitoring the nitrite concentration in pharmaceutical products and substances. This Application Note describes the analysis of nitrite in duloxetine hydrochloride with ion chromatography (IC).
- AN-S-402Nitrite in hydroxypropyl methylcellulose
Nitrosamine formation can be avoided by controlling the nitrite concentration in pharmaceutical products and processes. To monitor nitrosamine formation, sensitive analytical methods such as ion chromatography for the determination of nitrite in pharmaceutical products and substances are essential.
- AN-PAN-1011Online analysis of permanganate absorption number (PAN)
Permanganate absorption number (PAN) analysis per ISO 8660 ensures caprolactam purity, a precursor of Nylon 6. This application describes real-time, continuous PAN monitoring.
- AN-R-033Determination of antioxidant content with PEG as carrier material
Higher antioxidant levels mean longer product viability. The 892 Professional Rancimat determines antioxidant content in many products using a linear regression method.
- AN-RS-007Identification of polymer masterbatches with Raman spectroscopy
Handheld Raman spectroscopy enables rapid polymer masterbatch analysis, while Metrohm’s XTR® algorithm mitigates fluorescence interference for accurate additive identification.
- AN-EC-038Measuring ionic conductivity using screen-printing technology
Using disposable 11COND screen printed electrodes and electrochemical impedance spectroscopy, conductivity in drinking water can be measured using only 100 µL samples.
- AN-SEC-001Spectroelectrochemistry: an autovalidated analytical technique
Spectroelectrochemical experiments not only provide outstanding qualitative information about samples, but also offer other quantitative data that can be considered when performing analyses. A single set of experiments allows analysts to obtain two calibration curves: one with the electrochemical data and another with the spectroscopic information. The concentration of tested samples is calculated by using both curves, confirming the obtained results by two different routes. In this Application Note, comparison between electrochemical and spectroscopic determinations demonstrates that the two methods measure uric acid (UA) indistinctively, with close agreement of the calculated values with empirical data.
- AN-PAN-1027Online monitoring of TBC in styrene storage tanks according to ASTM D4590
Reliable monitoring of TBC in styrene according to ASTM D4590 requires an explosion-proof solution like the 2060 TI Ex Proof Analyzer.
- AN-PAN-1065Inline monitoring of cell cultures with Raman spectroscopy
This Process Application Note presents a method to accurately monitor lactic acid and glucose inside a bioreactor in «real-time» with the 2060 Raman Analyzer from Metrohm Process Analytics.
- AN-S-403Anions in lithium-ion battery solvents
N-Methylpyrrolidone (NMP) is crucial for lithium-ion battery production. Metrohm’s intelligent Preconcentration Technique with Matrix Elimination enables µg/L-level anion analysis in NMP.
- AN-COR-019Determining the corrosion rate with INTELLO
Tafel analysis is an important electrochemical technique used to understand reaction kinetics. By studying the Tafel slope, it reveals the rate-determining steps in electrode reactions, aiding fields like corrosion and fuel cell research. This method helps industries optimize processes and improve device performance by tailoring materials and conditions for greater efficiency.
- AN-EC-031Monitoring ferrocyanide oxidation using hyphenated EC-Raman
This Application Note highlights the use of Metrohm Hyphenated EC-Raman Solutions to monitor the reversible oxidation of ferrocyanide at a gold electrode.
- AN-P-086Quality assurance of instant coffee
Application: Free and total carbohydrate determination in instant coffee with IC-PAD according to AOAC 996.04 and ISO 11292.
- AN-PAN-1064Monitoring complexing agents in galvanic baths inline with Raman spectroscopy
Accurate analysis of complexing agents in galvanic baths is possible with inline Raman spectroscopy. This Application Note shows an example using a 2060 Raman Analyzer.
- AN-U-080Nitrite and nitrate in meat products
Nitrite and nitrate salts are used as preservatives for meat and meat products. Nitrate salts (labeled E 251 or E 252) have a low toxicity but long-term exposure is of concern, as the lower gut reduces them to nitrite, a precursor of nitrosamines (classified as carcinogenic). Nitrite itself is classified as probably carcinogenic to humans. The European Food Safety Authority (EFSA) lists the MPL (maximum permitted levels) after the manufacturing process for nitrite (labeled E 249 or E 250) as between 50–180 mg/kg, and for nitrate between 150–300 mg/kg, depending on the product. The European Commission (Regulation (EC) No 1333/2008) limits nitrate and nitrite salts in processed meat to less than 150 mg/kg. Ion chromatography with UV detection offers a robust and universal method for quality control of nitrite and nitrate in different meat matrices. Additional sample preparation techniques like Inline Ultrafiltration help to save time and costs as well as overcome analysis issues with difficult sample matrices.
- 410000004-ARaman Spectroscopy in Archaeological Studies
Portable Raman spectroscopy is an invaluable tool in the study of archaeological sites, allowing for in situ analysis which minimizes the impact of such studies on important cultural sites. The flexibility of the use of a fiber optic probe and tripod-mounted video microscope with a light weight instrument reduces the need for sampling, and increases the ability to make representative measurements over what can be very large sample areas. The information content of Raman spectroscopy aids in the understanding of the materials used in the construction and restoration of important archaeological sites, and in understanding the degradation that is occurring which should aid in preservation and restoration work.
- AN-EIS-009Mott-Schottky Analysis
This Application Note presents the Mott-Schottky measurement, an extension of electrochemical impedance spectroscopy (EIS), on a popular semiconducting material.
- AN-RS-053Estimation of amine value in epoxies with Raman spectroscopy
Compared to potentiometric titration, Raman spectroscopy is a rapid, accurate, and reliable secondary method for estimating the amine value (AV) of epoxy hardeners.
- AN-EIS-002Electrochemical Impedance Spectroscopy (EIS) Part 2 – Experimental Setup
A typical electrochemical impedance spectroscopy (EIS) experimental setup consists of an electrochemical cell, a potentiostat/galvanostat, and a frequency response analyzer (FRA). This Application Note introduces common EIS experimental setups as well as details of the main experimental parameters.
- AN-P-089Lactose intolerance and reliance on accurate food labels
Worldwide, milk and dairy products are vital sources for human nutrition. A major component and energy source in dairy products is lactose. To efficiently metabolize lactose, the enzyme lactase is indispensable. However, globally nearly 70% of the population is lactose intolerant and they have difficulties to digest lactose. Lactose malabsorption leads to numerous gastrointestinal and extra-intestinal symptoms and other complaints with varying extents. Therefore, consumers rely on accurate food labels and for manufacturers appropriate sensitive analytical techniques are a must to comply with these demands. Ion chromatography with pulsed amperometric detection (IC-PAD) enables the determination of very low lactose contents. Validation according to AOAC requirements shows the high sensitivity and reliability of this method as a routine analysis.
- AN-RS-049Determining phosphate concentration with Raman spectroscopy
Raman spectroscopy with PLS modeling enables rapid, accurate, nondestructive quantification of the total phosphate content in solution with minimal sample preparation.