NIO surfactant electrode
6.0507.010
NIO surfactant electrode
vi
6.0507.010
Tổng quan
This surfactant electrode has to be used in combination with a reference electrode and is suitable, e.g., for:
- titration of non-ionic surfactants in aqueous matrices
- titration of surfactants based on polyoxyethylene adducts
- titration of pharmaceutical ingredients using sodium tetraphenylborate
Thông số kỹ thuật
| Shaft material | PVC |
|---|---|
| Measuring range (theoretical) | tensidabhängig |
| Temperature range, long-term (°C) | 0 ... 40 |
| Temperature range, short-term (°C) | 0 ... 40 |
| pH range | 0...12 |
| Indicator electrode shape | Pin |
| Max. installation length (mm) | 125 |
| SGJ sleeve | Flexible SGJ sleeve |
| Shaft diameter top (mm) | 12 |
| Shaft diameter bottom (mm) | 2.5 |
| Min. immersion depth (mm) | 20 |
| Electrode plug-in head | Metrohm plug-in head G |
| Indicator electrode type | Non-ionic surfactants |
-
- Sleeve with SGJ 14/12 mm
- 6.1236.020
- Sleeve with SGJ 14/12 mm and O-ring.
- Sleeve with SGJ 14/12 mm and O-ring.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Sleeve with SGJ 14/12 mm
- 6.1236.020
- Sleeve with SGJ 14/12 mm and O-ring.
- Sleeve with SGJ 14/12 mm and O-ring.
- PCS
- 1
- Storage vessel
- 6.2008.040
- Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.
- <p>Together with 6.2008.050 storage vessel holder. it provides a support for the electrode on 807 Dosing Units.</p>
- PCS
- 1
-
- Ag/AgCl reference electrode (length 12.5 cm)
- 6.0726.100
- Silver/silver chloride reference electrode with Double-Junction System, installation length 10 cm.The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. This sensor is supplied without electrolyte filling.
- <p>Silver/silver chloride reference electrode with Double-Junction System, installation length 10 cm.<br/>The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. This sensor is supplied without electrolyte filling.</p>
- PCS
- 1
- LL ISE reference electrode
- 6.0750.100
- Silver / silver chloride reference electrode with double junction system.This reference electrode is well suited for:automated applications; ion measurements; surfactant titrations; The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.
- <p>Silver / silver chloride reference electrode with double junction system.<br/>This reference electrode is well suited for:</p><ul><li>automated applications</li><li>ion measurements</li><li>surfactant titrations</li></ul><p>The ground-joint diaphragm, which is insensitive to contamination, offers a constant and reproducible electrolyte outflow. Additionally, the reference electrolyte is gelified for even better signal stability. The sensor is delivered with c(KCl) = 3 mol/L as bridge electrolyte, which can be freely selected and exchanged as needed.</p>
- PCS
- 1
- Electrode cable / 1 m / F
- 6.2104.020
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).
- PCS
- 1