Spectroelectrochemical Raman instrument (785 nm laser)
DRP-SPELECRAMAN
Spectroelectrochemical Raman instrument (785 nm laser)
en
DRP-SPELECRAMAN
Visão geral
SPELECRAMAN is an instrument for performing spectroelectrochemical Raman measurements. It combines in only one box a laser class 3B (785 nm ± 0.5), a bipotentiostat/galvanostat and a spectrometer (wavelength range 787 – 1027 nm and Raman shift 35 - 3000 cm-1) and includes a dedicated spectroelectrochemical software that allows optical and electrochemical experiments synchronization.
Especificações técnicas
| Operating modes | Bipotentiostat; Potentiostat; Galvanostat |
|---|---|
| PC interface | USB |
| Power | 5 V DC |
| Potential range in volt | ±4 V |
| Maximum current in Ampère | ±40 mA |
| Number of current ranges | 8 |
| Number of current ranges remarks | ±1 nA to ±10 mA |
| Number of potential ranges (galvanostat) | 2 |
| Number of potential ranges remarks (galvanostat) | ±100 mV to ±1 V |
| Multichannel instrument | NO |
| Maximum number of channels | 1 |
| Maximum number of WE sharing AUX and REF | 2 |
| Potential accuracy | ±0.2 % |
| Current accuracy | ≤0.5 % of current range at 100 nA to 10 mA |
| Potential resolution | 1 mV |
| Current resolution | 011 % of current output range |
| Measured potential resolution | 0.012 % of potential range |
| Measured current resolution | 0.025 % of current range (1 pA on lowest current range) |
| Spectrometer (SPM) Detector | 2D CDD Array, Back thinned TE Cooled |
| SPM Pixels | 1044 x 64 |
| SPM Wavelength range | 787 - 1028 nm |
| SPM Optical resolution | < 4 cm-1 |
| SPM Signal-to-noise ratio | 1000 : 1 (at full signal) |
| SPM A/D resolution | 18 bit |
| SPM Dynamic range | 85000 : 1 |
| SPM Integration time | 8 ms to 60 min |
| SPM Fiber optic connector | SMA 905 |
| Light Source (LS) wavelength range | 785 ± 0.5 nm |
| LS Stability | (15 to 45 °C) |
| LS Fiber optic connector | FC |
| Dimensions | 25 X 24 X 11 cm |
| Weight of the instrument in kg | 3.6 |
| Spectral line width | <0.1 nm FWHM |
| Optical power output | 500 mW |
| Output power stability | ± 1 % |
| Raman shift | 50 - 3000 cm-1 |
-
- μStat 8000(P)/4000(P) one node cable connector for conventional electrodes
- DRP-CABSTAT1
- Connects individual nodes of the μStat 8000(P)/4000(P) to conventional electrodes
- <p>Connects individual nodes of the μStat 8000(P)/4000(P) to conventional electrodes</p>
- PCS
- 1
- Raman Probe
- DRP-RAMANPROBE
- Reflection probe designed to be used with a single excitation 785 nm wavelength (up to 500 mW). Suitable to work with DropSens Raman Cell for Screen-Printed Electrodes or with any conventional Raman set-up.
- <p>Reflection probe designed to be used with a single excitation 785 nm wavelength (up to 500 mW). Suitable to work with DropSens Raman Cell for Screen-Printed Electrodes or with any conventional Raman set-up.</p>
- PCS
- 1
- DropView SPELEC Software
- DropView SPELEC
- DropView SPELEC is a Spectroelectrochemical software that controls SPELEC instrument, offering a perfect synchronization of the optical and electrochemical measurements, as well as advanced tools for data treatment.
- <p>DropView SPELEC is a Spectroelectrochemical software that controls SPELEC instrument, offering a perfect synchronization of the optical and electrochemical measurements, as well as advanced tools for data treatment.</p>
- PCS
- 1
-
- μStat 8000(P)/4000(P) one node cable connector for conventional electrodes
- DRP-CABSTAT1
- Connects individual nodes of the μStat 8000(P)/4000(P) to conventional electrodes
- <p>Connects individual nodes of the μStat 8000(P)/4000(P) to conventional electrodes</p>
- PCS
- 1
- Raman Probe
- DRP-RAMANPROBE
- Reflection probe designed to be used with a single excitation 785 nm wavelength (up to 500 mW). Suitable to work with DropSens Raman Cell for Screen-Printed Electrodes or with any conventional Raman set-up.
- <p>Reflection probe designed to be used with a single excitation 785 nm wavelength (up to 500 mW). Suitable to work with DropSens Raman Cell for Screen-Printed Electrodes or with any conventional Raman set-up.</p>
- PCS
- 1
- DropView SPELEC Software
- DropView SPELEC
- DropView SPELEC is a Spectroelectrochemical software that controls SPELEC instrument, offering a perfect synchronization of the optical and electrochemical measurements, as well as advanced tools for data treatment.
- <p>DropView SPELEC is a Spectroelectrochemical software that controls SPELEC instrument, offering a perfect synchronization of the optical and electrochemical measurements, as well as advanced tools for data treatment.</p>
- PCS
- 1
-
- Raman Cell for Screen-Printed Electrodes
- DRP-RAMANCELL
- Black teflon reflection cell for performing Raman Spectroelectrochemistry with screen-printed electrodes in combination with ref. RAMANPROBE.
- <p>Black teflon reflection cell for performing Raman Spectroelectrochemistry with screen-printed electrodes in combination with ref. RAMANPROBE.</p>
- PCS
- 1
- Raman spectroelectrochemical cell for conventional electrodes
- DRP-RAMANCELL-C
- Cell in PEEK for Raman spectroelectrochemical measurements. Designed be used with ref. RAMANPROBE and conventional Metrohm electrodes.
- <p>Cell in PEEK for Raman spectroelectrochemical measurements. Designed be used with ref. RAMANPROBE and conventional Metrohm electrodes.</p>
- PCS
- 1