Foi redireccionado para a sua versão local da página solicitada.
884 Professional VA

884 Professional VA

2.884.0010

    • Wrench
    • 6.2739.000
    • For tightening connectors
    • For tightening connectors
    • PCS
    • 1
    • 884 Professional VA
    • 1.884.0010
    • 884 Professional VA is the universal entry-level instrument in the Professional VA/CVS instrument series. In conjunction with the compatible measuring head and compatible electrode set, you can perform trace analysis determinations, voltammetry with the Multi-Mode Electrode pro, or determinations of organic additives in electroplating baths, with "Cyclic Voltammetric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and chronopotentiometry (CP). The proven Metrohm electrode methods combined with a completely new design of potentiostat/galvanostat and the extremely high-performance viva software open up new perspectives. The potentiostat with a certified calibrator readjusts itself automatically before each measurement, thus guaranteeing maximum precision. The replaceable measuring head enables rapid changes between various applications with different electrodes.The viva software is required for control, data acquisition, and evaluation.The 884 Professional VA is supplied with reduced accessories, without measuring head and electrodes. Electrode set and viva license are to be ordered separately.  
    • <p>884 Professional VA is the universal entry-level instrument in the Professional VA/CVS instrument series. In conjunction with the compatible measuring head and compatible electrode set, you can perform trace analysis determinations, voltammetry with the Multi-Mode Electrode pro, or determinations of organic additives in electroplating baths, with &quot;Cyclic Voltammetric Stripping&quot; (CVS), &quot;Cyclic Pulse Voltammetric Stripping&quot; (CPVS), and chronopotentiometry (CP). The proven Metrohm electrode methods combined with a completely new design of potentiostat/galvanostat and the extremely high-performance <strong>viva</strong> software open up new perspectives. The potentiostat with a certified calibrator readjusts itself automatically before each measurement, thus guaranteeing maximum precision. The replaceable measuring head enables rapid changes between various applications with different electrodes.<br /><br />The <strong>viva</strong> software is required for control, data acquisition, and evaluation.<br /><br />The 884 Professional VA is supplied with reduced accessories, without measuring head and electrodes. Electrode set and <strong>viva</strong> license are to be ordered separately. &nbsp;</p>
    • PCS
    • 1
    • Wrench
    • 6.2739.000
    • For tightening connectors
    • For tightening connectors
    • PCS
    • 1
    • 800 Dosino
    • 2.800.0020
    • Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 0.65 m).
    • <p>Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 0.65 m).</p>
    • PCS
    • 1
    • 858 Professional Sample Processor VA for antioxidants
    • 2.858.0130
    • The 858 Professional Sample Processor VA for antioxidants enables the fully automatic processing of sample series of lubricants for determining the concentration of antioxidants in combination with Professional VA instruments and viva. The system is controlled directly with the viva software. The sample rack (supplied) holds 24 samples, which are extracted automatically on the sample changer for sample preparation prior to determination.The 858 Professional CVS Sample Processor VA for antioxidants is supplied with built-in robotic arm, together with accessories, sample rack, magnetic stirrer, and connection cable for setting up a complete workplace, although it does not come with rinsing equipment.
    • <p>The 858 Professional Sample Processor VA for antioxidants enables the fully automatic processing of sample series of lubricants for determining the concentration of antioxidants in combination with Professional VA instruments and <strong>viva</strong>. The system is controlled directly with the <strong>viva</strong> software. The sample rack (supplied) holds 24 samples, which are extracted automatically on the sample changer for sample preparation prior to determination.</p><p>The 858 Professional CVS Sample Processor VA for antioxidants is supplied with built-in robotic arm, together with accessories, sample rack, magnetic stirrer, and connection cable for setting up a complete workplace, although it does not come with rinsing equipment.</p>
    • PCS
    • 1
    • SPE measuring head for Professional VA instruments
    • 6.1256.030
    • Measuring head for operation with screen-printed electrodes (SPE) or the scTRACE Gold.
    • <p>Measuring head for operation with <em>screen-printed electrodes</em> (SPE) or the scTRACE Gold.</p>
    • PCS
    • 1
    • Electrode cable / 1 m / 2 x 2 mm
    • 6.2104.140
    • For connecting temperature sensors with Metrohm plug-in head G with 780, 781, 826, 827 pH/Ion meters and all Titrandos
    • For connecting temperature sensors with Metrohm plug-in head G with 780, 781, 826, 827 pH/Ion meters and all Titrandos
    • PCS
    • 1
    • CVS electrode equipment with 1 mm platinum electrode for Professional VA/CVS instruments
    • 6.5339.000
    • Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 1 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.
    • <p>Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 1 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.</p>
    • PCS
    • 1
    • CVS electrode equipment with 2 mm platinum electrode for Professional VA/CVS instruments
    • 6.5339.010
    • Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.
    • <p>Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions. </p>
    • PCS
    • 1
    • CVS electrode equipment with 3 mm platinum electrode for Professional VA/CVS instruments
    • 6.5339.020
    • Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 3 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions.
    • <p>Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 3 mm), reference electrode, platinum auxiliary electrode, measuring vessels and electrolyte solutions. </p>
    • PCS
    • 1
    • VA electrode equipment with Multi-Mode Electrode pro for Professional VA instruments
    • 6.5339.030
    • Complete electrode set for polarographic and voltammetric determinations. Includes Multi-Mode Electrode pro, reference electrode, platinum auxiliary electrode, measuring vessel, stirrer, electrolyte solution and additional accessories for setting up and operating the Multi-Mode Electrode.
    • <p>Complete electrode set for polarographic and voltammetric determinations. Includes Multi-Mode Electrode pro, reference electrode, platinum auxiliary electrode, measuring vessel, stirrer, electrolyte solution and additional accessories for setting up and operating the Multi-Mode Electrode.</p>
    • PCS
    • 1
    • VA electrode equipment with rotating disk electrode (RDE) made of glassy carbon for Professional VA instruments
    • 6.5339.040
    • Complete electrode set for voltammetric determinations, e.g. using mercury film method. Includes drive for rotating disk electrode, glassy carbon electrode tip, reference electrode, glassy carbon auxiliary electrode, measuring vessel, and electrolyte solution.  
    • <p>Complete electrode set for voltammetric determinations, e.g. using mercury film method. Includes drive for rotating disk electrode, glassy carbon electrode tip, reference electrode, glassy carbon auxiliary electrode, measuring vessel, and electrolyte solution.  </p>
    • PCS
    • 1
    • VA electrode equipment with scTRACE Gold for Professional VA instruments
    • 6.5339.050
    • Complete electrode set for the determination of arsenic or mercury. Includes holders for scTRACE Gold, scTRACE Gold, stirrer and measuring vessel.   
    • <p>Complete electrode set for the determination of arsenic or mercury. Includes holders for scTRACE Gold, scTRACE Gold, stirrer and measuring vessel.   </p>
    • PCS
    • 1
    • CVS electrode equipment with 2 mm platinum electrode for Professional VA/CVS instruments for intensive use
    • 6.5339.060
    • Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), driving axle with mercury contact, maintenance-free gel reference electrode, platinum auxiliary electrode, measuring vessels and KCl electrolyte solution.
    • <p>Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), driving axle with mercury contact, maintenance-free gel reference electrode, platinum auxiliary electrode, measuring vessels and KCl electrolyte solution.</p>
    • PCS
    • 1
    • VA accessory equipment with SPE electrode shaft for professional VA instruments
    • 6.5339.070
    • Accessory equipment for use with screen-printed electrodes (SPE). Contains electrode shaft for screen-printed electrodes, stirrer, and measuring vessel. Without electrodes.
    • <p>Accessory equipment for use with <em>screen-printed electrodes</em> (SPE). Contains electrode shaft for screen-printed electrodes, stirrer, and measuring vessel. Without electrodes.</p>
    • PCS
    • 1
    • VA electrode equipment with bismuth drop electrode for Professional VA instruments
    • 6.5339.080
    • Complete electrode set for voltammetric determinations of heavy metals. Contains bismuth drop electrode, reference electrode, glassy carbon auxiliary electrode, measuring vessel, stirrer, electrolyte solution, and additional accessories.
    • <p>Complete electrode set for voltammetric determinations of heavy metals. Contains bismuth drop electrode, reference electrode, glassy carbon auxiliary electrode, measuring vessel, stirrer, electrolyte solution, and additional accessories. </p>
    • PCS
    • 1
    • CVS electrode equipment with 2 mm platinum electrode, gel reference electrode and steel auxiliary electrode for Professional VA/CVS instruments
    • 6.5339.110
    • Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), driving axle with mercury contact, maintenance-free gel reference electrode, steel auxiliary electrode, measuring vessels and KCl electrolyte solution.
    • <p>Complete electrode set for the determination of organic additives in electroplating baths with CVS (Cyclic Voltammetric Stripping). Contains rotating platinum working electrode (electrode diameter: 2 mm), driving axle with mercury contact, maintenance-free gel reference electrode, steel auxiliary electrode, measuring vessels and KCl electrolyte solution.</p>
    • PCS
    • 1
    • Equipment with 2x 807 Dosing Units for VA and CVS measurements
    • 6.5339.500
    • Accessory set for 2 auxiliary solutions for expanding VA or CVS systems. Contains 2x 807 Dosing Units 2 mL, 2x 100 mL clear glass bottles, bottle holder for 2 bottles, and connector material. Without Dosinos.
    • <p>Accessory set for 2 auxiliary solutions for expanding VA or CVS systems. Contains 2x 807 Dosing Units 2 mL, 2x 100 mL clear glass bottles, bottle holder for 2 bottles, and connector material. Without Dosinos. </p>
    • PCS
    • 1
    • Basic equipment with 2x 807 Dosing Units for VA measurements for 884 Professional VA
    • 6.5339.510
    • Accessory set for 2 auxiliary solutions for expanding manual VA systems. Includes one 807 Dosing Unit 2 mL and one 807 Dosing Unit 5 mL, clear glass bottles 100 mL, 250 mL and 2 L, bottle holders for 2 bottles, one 4-way micro tip, and connector material. Without Dosinos.  
    • <p>Accessory set for 2 auxiliary solutions for expanding manual VA systems. Includes one 807 Dosing Unit 2 mL and one 807 Dosing Unit 5 mL, clear glass bottles 100 mL, 250 mL and 2 L, bottle holders for 2 bottles, one 4-way micro tip, and connector material. Without Dosinos.  </p>
    • PCS
    • 1
    • Equipment with two 807 Dosing Units (2 + 50 mL) for CVS measurements
    • 6.5339.520
    • Accessory set for two auxiliary solutions for expanding CVS systems. Includes one 2 mL and on 50 mL 807 Dosing Unit each, clear glass bottles 100 mL and 2 L, bottle holders for 2 bottles, one 2-way microtip, and connector material. Without Dosinos.
    • <p>Accessory set for two auxiliary solutions for expanding CVS systems. Includes one 2 mL and on 50 mL 807 Dosing Unit each, clear glass bottles 100 mL and 2 L, bottle holders for 2 bottles, one 2-way microtip, and connector material. Without Dosinos.</p>
    • PCS
    • 1
    • viva 4.0 Full: 1 license
    • 6.6065.402
    • Computer program for control and data management of Professional VA/CVS instruments. The software permits checks, data acquisition, evaluation, and monitoring, as well as generation of reports.Graphic user interface for routine operations, extensive database programs with reevaluation, graphic method editor with numerous templates, system configuration, very flexible user management, extensive data export functions, individually configurable report generator.Includes the "Differential Pulse" (DP), "Square Wave" (SQW), "Linear Sweep Voltammetry" (LSV), "Cyclic Voltammetry" (CV), "Cyclic Voltametric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and Chronopotentiometry (CP) measuring modes. The following calibration techniques are supported: Standard addition, external calibration, DT (Dilution Titration), LAT (Linear Approximation Technique), MLAT (Modified Linear Approximation Technique), RC (Response Curve).Dialog languages: German, English, Chinese, Japanese.The following instruments are supported: 884 Professional VA, 894 Professional CVS1 license for a maximum of 4 Professional VA/CVS instruments on a single computer. Contains USB flash drive and installation documentation.
    • <p>Computer program for control and data management of Professional VA/CVS instruments. The software permits checks, data acquisition, evaluation, and monitoring, as well as generation of reports.</p><p>Graphic user interface for routine operations, extensive database programs with reevaluation, graphic method editor with numerous templates, system configuration, very flexible user management, extensive data export functions, individually configurable report generator.</p><p>Includes the "Differential Pulse" (DP), "Square Wave" (SQW), "Linear Sweep Voltammetry" (LSV), "Cyclic Voltammetry" (CV), "Cyclic Voltametric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and Chronopotentiometry (CP) measuring modes. The following calibration techniques are supported: Standard addition, external calibration, DT (Dilution Titration), LAT (Linear Approximation Technique), MLAT (Modified Linear Approximation Technique), RC (Response Curve).</p><p>Dialog languages: German, English, Chinese, Japanese.</p><p>The following instruments are supported: 884 Professional VA, 894 Professional CVS</p><p>1 license for a maximum of 4 Professional VA/CVS instruments on a single computer. Contains USB flash drive and installation documentation.</p>
    • PCS
    • 1
    • viva 4.0 Multi: 3 licenses
    • 6.6065.403
    • Client/server-compatible computer program for control and data management of Professional VA/CVS instruments. The software permits checks, data acquisition, evaluation, and monitoring, as well as report generation.Graphic user interface for routine operations, extensive database programs with reevaluation, graphic method editor with numerous templates, system configuration, very flexible user management, extensive data export functions, individually configurable report generator.Includes the "Differential Pulse" (DP), "Square Wave" (SQW), "Linear Sweep Voltammetry" (LSV), "Cyclic Voltammetry" (CV), "Cyclic Voltametric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and Chronopotentiometry (CP) measuring modes. The following calibration techniques are supported: Standard addition, external calibration, DT (Dilution Titration), LAT (Linear Approximation Technique), MLAT (Modified Linear Approximation Technique), RC (Response Curve).Dialog languages: German, English, Chinese, Japanese.The following instruments are supported: 884 Professional VA, 894 Professional CVSClient/server version with 3 licenses for 3 computers with a max. of 4 Professional VA/CVS instruments per computer. Contains USB flash drive and installation documentation.
    • <p>Client/server-compatible computer program for control and data management of Professional VA/CVS instruments. The software permits checks, data acquisition, evaluation, and monitoring, as well as report generation.</p><p>Graphic user interface for routine operations, extensive database programs with reevaluation, graphic method editor with numerous templates, system configuration, very flexible user management, extensive data export functions, individually configurable report generator.</p><p>Includes the "Differential Pulse" (DP), "Square Wave" (SQW), "Linear Sweep Voltammetry" (LSV), "Cyclic Voltammetry" (CV), "Cyclic Voltametric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and Chronopotentiometry (CP) measuring modes. The following calibration techniques are supported: Standard addition, external calibration, DT (Dilution Titration), LAT (Linear Approximation Technique), MLAT (Modified Linear Approximation Technique), RC (Response Curve).</p><p>Dialog languages: German, English, Chinese, Japanese.</p><p>The following instruments are supported: 884 Professional VA, 894 Professional CVS</p><p>Client/server version with 3 licenses for 3 computers with a max. of 4 Professional VA/CVS instruments per computer. Contains USB flash drive and installation documentation.</p>
    • PCS
    • 1