941 Eluent Production Module
2.941.0010
941 Eluent Production Module
en
2.941.0010
Feature overview
The 941 Eluent Production Module enables the automatic production of an eluent. It enables continuous working without manual intervention and guarantees stable retention times. It can be combined with all Metrohm IC instruments and is monitored by MagIC Net.
Product Family
- title
- Extension Modules
- description
- Complex applications with the most flexible IC – Upgrade your 940 Professional IC Vario with Extension Modules and additional detectors.
Documents
-
81025010
-
de
- title
- Prospekt: MagIC Net 4.2
- description
- MagIC Net ist eine Steuerungs- und Datenbanksoftware für Ionenchromatographiegeräte.Die Software steuert die intelligenten Metrohm Ionenchromatographiesysteme sowie deren Peripheriegeräte für Liquid-Handling und Automation.Mit MagIC Net können alle IC-Geräte gesteuert werden, von Eco- und Microbore-IC- oder Combustion IC-Systemen über verschiedene Detektoren (947 Professional UV/VIS Detector Vario, amperometrischer Detektor) bis hin zu Probenwechslern. MagIC Net unterstützt die Automation der Systeme, einschliesslich Inline-Probenvorbereitungstechniken, intelligenten Injektionstechniken sowie logischen Features.
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/1025/81025010
-
en
- title
- Brochure: MagIC Net 4.2
- description
- MagIC Net is a control and database software for ion chromatography instruments.The software controls the components of the intelligent Metrohm ion chromatography systems as well as their peripheral devices for Liquid Handling and automation.All IC instruments can be controlled by MagIC Net rising from Eco to the microbore IC systems or combustion IC, different detectors (947 Professional UV/VIS Detector Vario, Amperometric Detector), and Sample Changers. MagIC Net supports automation of the systems including Inline Sample Preparation Techniques, intelligent Injection Techniques as well as logical features.
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/1025/81025010
-
vi
- title
- Brochure: MagIC Net 4.2
- description
- MagIC Net is a control and database software for ion chromatography instruments.The software controls the components of the intelligent Metrohm ion chromatography systems as well as their peripheral devices for Liquid Handling and automation.All IC instruments can be controlled by MagIC Net rising from Eco to the microbore IC systems or combustion IC, different detectors (947 Professional UV/VIS Detector Vario, Amperometric Detector), and Sample Changers. MagIC Net supports automation of the systems including Inline Sample Preparation Techniques, intelligent Injection Techniques as well as logical features.
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/1025/81025010
-
de
-
81025011
-
en
- title
- Flyer: Peace of mind with MagIC Net - Compliance with the Data Integrity Guidelines made easy
- description
- Data integrity requires data to be complete, consistent, and accurate throughout their complete lifecycle, thus providing full transparency and traceability. Our chromatography software MagIC Net gives you peace of mind, as it ensures all data to have the following qualities stipulated by ALCOA and ALCOA+. This flyer porvides further information about data integrity for MagIC Net.
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/1025/81025011
-
vi
- title
- Flyer: Peace of mind with MagIC Net - Compliance with the Data Integrity Guidelines made easy
- description
- Data integrity requires data to be complete, consistent, and accurate throughout their complete lifecycle, thus providing full transparency and traceability. Our chromatography software MagIC Net gives you peace of mind, as it ensures all data to have the following qualities stipulated by ALCOA and ALCOA+. This flyer porvides further information about data integrity for MagIC Net.
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/1025/81025011
-
en
-
89413003
-
de
- title
- Konformitätserklärung 941 Eluent Production Module
- description
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/9413/89413003
-
en
- title
- Declaration of Conformity for 941 Eluent Production Module
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/9413/89413003
-
fr
- title
- Déclaration de conformité pour le 941 Eluent Production Module
- description
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/9413/89413003
-
ja
- title
- 941 Eluent Production Module の適合宣言
- description
- language
- ja
- documentpath
- /content/metrohm/shared/ja/products/8/9413/89413003
-
es
- title
- Declaración de conformidad para el 941 Eluent Production Module
- description
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/9413/89413003
-
zh
- title
- 941 Eluent Production Module 一致性声明
- description
- language
- zh
- documentpath
- /content/metrohm/shared/zh/products/8/9413/89413003
-
pt
- title
- EU declaration of Conformity for 941 Eluent Production Module
- description
- language
- pt
- documentpath
- /content/metrohm/shared/pt/products/8/9413/89413003
-
vi
- title
- Declaration of Conformity for 941 Eluent Production Module
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/9413/89413003
-
de
-
89415000
-
de
- title
- Prospekt: 941 Eluent Production Module – Inline-Eluentherstellung für die Ionenchromatographie
- description
- Mit dem 941 Eluent Production Module integriert Metrohm die Inline-Herstellung des Eluenten in die Ionenchromatographender Baureihen 940 Professional IC Vario und 930 Compact IC Flex sowie alle übrigen intelligenten Ionenchromatographen von Metrohm. Dieser Prospekt stellt Ihnen die Vorteile der Inline-Eluentherstellung vor.
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/9415/89415000
-
en
- title
- Brochure: 941 Eluent Production Module – Inline eluent production for ion chromatography
- description
- With the 941 Eluent Production Module, Metrohm integrates inline eluent production in the ion chromatographsof the 940 Professional IC Vario and 930 Compact IC Flex series, as well as in all of the other intelligent ion chromatographs from Metrohm. This brochure introduces you to the advantages of inline eluent production.
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/9415/89415000
-
fr
- title
- Prospectus : 941 Eluent Production Module – Fabrication d'éluants inline pour la chromatographie ionique
- description
- Avec le 941 Eluent Production Module, Metrohm intègre la fabrication d'éluants inline dans les chromatographes ioniquesdes séries 940 Professional IC Vario et 930 Compact IC Flex ainsi que dans tous les autres chromatographes ioniques intelligents de Metrohm. Ce prospectus vous présente les avantages de la fabrication d'éluants inline.
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/9415/89415000
-
es
- title
- Folleto: 941 Eluent Production Module – Elaboración de eluyentes inline para la cromatografía iónica
- description
- Con el 941 Eluent Production Module, Metrohm integra la elaboración inline del eluyente en los cromatógrafos iónicosde la serie 940 Professional IC Vario y 930 Compact IC Flex, así como todos los cromatógrafos iónicos inteligentes de Metrohm restantes. Este folleto le presenta las ventajas de la elaboración de eluyentes inline.
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/9415/89415000
-
vi
- title
- Brochure: 941 Eluent Production Module – Inline eluent production for ion chromatography
- description
- With the 941 Eluent Production Module, Metrohm integrates inline eluent production in the ion chromatographsof the 940 Professional IC Vario and 930 Compact IC Flex series, as well as in all of the other intelligent ion chromatographs from Metrohm. This brochure introduces you to the advantages of inline eluent production.
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/9415/89415000
-
de
-
80005455
-
en
- title
- Flyer: Order numbers for the 930/940 IC instruments
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/0005/80005455
-
vi
- title
- Flyer: Order numbers for the 930/940 IC instruments
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/0005/80005455
-
en
-
80005436
-
en
- title
- Flyer: Bring your USP methods up to date!
- description
- This flyer gives an overview of monographs recently updated by USP, and which now stipulate ion chromatography methods for numerous pharmaceutical assays of APIs, impurities, and excipients.
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/0005/80005436
-
vi
- title
- Flyer: Bring your USP methods up to date!
- description
- This flyer gives an overview of monographs recently updated by USP, and which now stipulate ion chromatography methods for numerous pharmaceutical assays of APIs, impurities, and excipients.
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/0005/80005436
-
en
-
89418001
-
de
- title
- Handbuch 29410010 Eluent Production Module
- description
- language
- de
- documentpath
- /content/metrohm/shared/de/products/8/9418/89418001
-
en
- title
- Manual for 29410010 Eluent Production Module
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/9418/89418001
-
fr
- title
- Mode d’emploi 29410010 Eluent Production Module
- description
- language
- fr
- documentpath
- /content/metrohm/shared/fr/products/8/9418/89418001
-
ja
- title
- ハンドブック 29410010 Eluent Production Module
- description
- language
- ja
- documentpath
- /content/metrohm/shared/ja/products/8/9418/89418001
-
es
- title
- Manual 29410010 Eluent Production Module
- description
- language
- es
- documentpath
- /content/metrohm/shared/es/products/8/9418/89418001
-
zh
- title
- 29410010 Eluent Production Module 手册
- description
- language
- zh
- documentpath
- /content/metrohm/shared/zh/products/8/9418/89418001
-
vi
- title
- Manual for 29410010 Eluent Production Module
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/9418/89418001
-
de
-
88568006
-
en
- title
- Release Notes for various instruments, USB 3.0 compatibility
- description
- language
- en
- documentpath
- /content/metrohm/shared/en/products/8/8568/88568006
-
vi
- title
- Release Notes for various instruments, USB 3.0 compatibility
- description
- language
- vi
- documentpath
- /content/metrohm/shared/vi/products/8/8568/88568006
-
en
-
- Piston tongs
- 6.1546.030
- For pistons for 807 Dosing Units or cylinder units OMNIS.
- <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
- PCS
- 1
- Bottle attachment GL 45 for eluents and reagents
- 6.1602.160
- For eluent, reagent, and rinsing bottles, with connectors for the adsorber tube and the aspiration tubing.
- <p>For eluent, reagent, and rinsing bottles, with connectors for the adsorber tube and the aspiration tubing.</p>
- PCS
- 1
- Eluent bottle / 2 L / GL 45
- 6.1608.070
- PCS
- 1
- Thread adapter 40 mm to GL 45
- 6.1618.050
- Adapter for bottles with 40 mm thread to GL45.
- Adapter for bottles with 40 mm thread to GL45.
- PCS
- 1
- Container 10 L
- 6.1621.000
- As rinsing or waste container in automated systems.
- As rinsing or waste container in automated systems.
- PCS
- 1
- Cap for 10-L container
- 6.1621.100
- Cap for 10-L container. For easy and safe transportation of filled containers.
- Cap for 10-L container. For easy and safe transportation of filled containers.
- PCS
- 1
- Adapter SGJ 14 for 6.1619.XXX Adsorber tube
- 6.1624.000
- Adapter SGJ 14. Part of 6.1619.010 for Dilution Sample Processor.
- <p>Adapter SGJ 14. Part of 6.1619.010 for Dilution Sample Processor.</p>
- PCS
- 1
- Bottle attachment GL 45 for level sensor
- 6.1626.000
- This bottle attachment, fitted with the 6.2769.XXX sensors, results in the level sensors EMPTY and FULL, respectively, for bottles and canisters.
- <p>This bottle attachment, fitted with the 6.2769.XXX sensors, results in the level sensors EMPTY and FULL, respectively, for bottles and canisters.</p>
- PCS
- 1
- FEP tubing / M6 / 2 m
- 6.1805.530
- With light and kink protection
- With light and kink protection
- PCS
- 4
- Adapter 807 Dosing Unit Port 4, M6 inner
- 6.1808.280
- Adapter for using Port 4 of the 807 dosing Unit for connection with an FEP tubing / M6.
- <p>Adapter for using Port 4 of the 807 dosing Unit for connection with an FEP tubing / M6.</p>
- PCS
- 1
- Spiral band 0.5 m
- 6.1815.010
- For holding together different cables or tubing.
- For holding together different cables or tubing.
- PCS
- 1
- FEP aspiration tubing to 2 L bottle
- 6.1819.100
- Aspiration tubing to bottle attachment with M6 connector. For the production of eluents.
- <p>Aspiration tubing to bottle attachment with M6 connector. For the production of eluents.</p>
- PCS
- 1
- FEP aspiration tubing to canister
- 6.1819.110
- Aspiration tubing to canister attachment with M6 connector. For the production of eluents.
- <p>Aspiration tubing to canister attachment with M6 connector. For the production of eluents.</p>
- PCS
- 1
- Cable USB A – mini-DIN 8-pin
- 6.2151.000
- Controller cable
- Controller cable
- PCS
- 1
- Cable for Level Control and Eluent Production Module
- 6.2151.060
- Connecting cable for sensor and Level Control or Eluent Production Module.
- <p>Connecting cable for sensor and Level Control or Eluent Production Module.</p>
- PCS
- 1
- Adapter UNF 10/32 outer / M6 inner
- 6.2744.200
- Connecting 1/16 in. PEEK capillaries and transfer tubing (M6)
- Connecting 1/16 in. PEEK capillaries and transfer tubing (M6)
- PCS
- 1
- FULL sensor for level sensor
- 6.2769.000
- This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor FULL for 1 L and 2 L bottles and for canisters. Included are two sensor rods, one inlet tubing and one holder for fixing the tubing to one of the sensor rods.
- <p>This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor FULL for 1 L and 2 L bottles and for canisters. Included are two sensor rods, one inlet tubing and one holder for fixing the tubing to one of the sensor rods.</p>
- PCS
- 1
- 807 Dosing Unit 50 mL
- 6.3032.250
- 807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 1
-
- 941 Eluent Production Module
- 1.941.0010
- The 941 Eluent Production Module enables the automatic production of an eluent. It enables continuous working without manual intervention and guarantees stable retention times. It can be combined with all Metrohm IC instruments and is monitored by MagIC Net.
- <p>The 941 Eluent Production Module enables the automatic production of an eluent. It enables continuous working without manual intervention and guarantees stable retention times. It can be combined with all Metrohm IC instruments and is monitored by MagIC Net.</p>
- PCS
- 1
- 800 Dosino (cable length 1.5 m)
- 1.800.0030
- Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).
- <p>Drive with write/read hardware for intelligent dosing units. With permanently attached cable (length 1.5 m).</p>
- PCS
- 1
- Piston tongs
- 6.1546.030
- For pistons for 807 Dosing Units or cylinder units OMNIS.
- <p>For pistons for 807 Dosing Units or cylinder units OMNIS.</p>
- PCS
- 1
- Bottle attachment GL 45 for eluents and reagents
- 6.1602.160
- For eluent, reagent, and rinsing bottles, with connectors for the adsorber tube and the aspiration tubing.
- <p>For eluent, reagent, and rinsing bottles, with connectors for the adsorber tube and the aspiration tubing.</p>
- PCS
- 1
- Eluent bottle / 2 L / GL 45
- 6.1608.070
- PCS
- 1
- Thread adapter 40 mm to GL 45
- 6.1618.050
- Adapter for bottles with 40 mm thread to GL45.
- Adapter for bottles with 40 mm thread to GL45.
- PCS
- 1
- Container 10 L
- 6.1621.000
- As rinsing or waste container in automated systems.
- As rinsing or waste container in automated systems.
- PCS
- 1
- Cap for 10-L container
- 6.1621.100
- Cap for 10-L container. For easy and safe transportation of filled containers.
- Cap for 10-L container. For easy and safe transportation of filled containers.
- PCS
- 1
- Adapter SGJ 14 for 6.1619.XXX Adsorber tube
- 6.1624.000
- Adapter SGJ 14. Part of 6.1619.010 for Dilution Sample Processor.
- <p>Adapter SGJ 14. Part of 6.1619.010 for Dilution Sample Processor.</p>
- PCS
- 1
- Bottle attachment GL 45 for level sensor
- 6.1626.000
- This bottle attachment, fitted with the 6.2769.XXX sensors, results in the level sensors EMPTY and FULL, respectively, for bottles and canisters.
- <p>This bottle attachment, fitted with the 6.2769.XXX sensors, results in the level sensors EMPTY and FULL, respectively, for bottles and canisters.</p>
- PCS
- 1
- FEP tubing / M6 / 2 m
- 6.1805.530
- With light and kink protection
- With light and kink protection
- PCS
- 4
- Adapter 807 Dosing Unit Port 4, M6 inner
- 6.1808.280
- Adapter for using Port 4 of the 807 dosing Unit for connection with an FEP tubing / M6.
- <p>Adapter for using Port 4 of the 807 dosing Unit for connection with an FEP tubing / M6.</p>
- PCS
- 1
- Spiral band 0.5 m
- 6.1815.010
- For holding together different cables or tubing.
- For holding together different cables or tubing.
- PCS
- 1
- FEP aspiration tubing to 2 L bottle
- 6.1819.100
- Aspiration tubing to bottle attachment with M6 connector. For the production of eluents.
- <p>Aspiration tubing to bottle attachment with M6 connector. For the production of eluents.</p>
- PCS
- 1
- FEP aspiration tubing to canister
- 6.1819.110
- Aspiration tubing to canister attachment with M6 connector. For the production of eluents.
- <p>Aspiration tubing to canister attachment with M6 connector. For the production of eluents.</p>
- PCS
- 1
- Cable USB A – mini-DIN 8-pin
- 6.2151.000
- Controller cable
- Controller cable
- PCS
- 1
- Cable for Level Control and Eluent Production Module
- 6.2151.060
- Connecting cable for sensor and Level Control or Eluent Production Module.
- <p>Connecting cable for sensor and Level Control or Eluent Production Module.</p>
- PCS
- 1
- Adapter UNF 10/32 outer / M6 inner
- 6.2744.200
- Connecting 1/16 in. PEEK capillaries and transfer tubing (M6)
- Connecting 1/16 in. PEEK capillaries and transfer tubing (M6)
- PCS
- 1
- FULL sensor for level sensor
- 6.2769.000
- This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor FULL for 1 L and 2 L bottles and for canisters. Included are two sensor rods, one inlet tubing and one holder for fixing the tubing to one of the sensor rods.
- <p>This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor FULL for 1 L and 2 L bottles and for canisters. Included are two sensor rods, one inlet tubing and one holder for fixing the tubing to one of the sensor rods.</p>
- PCS
- 1
- 807 Dosing Unit 50 mL
- 6.3032.250
- 807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.
- <p>807 Dosing Unit with integrated data chip with 50 mL glass cylinder and light protection, mountable to a reagent bottle with ISO/DIN GL 45 glass thread. FEP tubing connection, antidiffusion tip.</p>
- PCS
- 1
-
- EMPTY sensor for level sensor for 1 L bottles
- 6.2769.100
- This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor EMPTY for 1 L bottles. Included are two sensor rods, one aspiration tubing and two holders for fixing the tubing to one of the sensor rods.
- <p>This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor EMPTY for 1 L bottles. Included are two sensor rods, one aspiration tubing and two holders for fixing the tubing to one of the sensor rods.</p>
- PCS
- 1
- EMPTY sensor for level sensor for 2 L bottles
- 6.2769.110
- This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor EMPTY for 2 L bottles. Included are two sensor rods, one aspiration tubing and two holders for fixing the tubing to one of the sensor rods.
- <p>This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor EMPTY for 2 L bottles. Included are two sensor rods, one aspiration tubing and two holders for fixing the tubing to one of the sensor rods.</p>
- PCS
- 1
- EMPTY sensor for level sensor for 10 L canisters
- 6.2769.120
- This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor EMPTY for 10 L canisters. Included are two sensor rods, one aspiration tubing and two holders for fixing the tubing to one of the sensor rods.
- <p>This sensor, mounted in the 6.1626.000 bottle attachment, results in the level sensor EMPTY for 10 L canisters. Included are two sensor rods, one aspiration tubing and two holders for fixing the tubing to one of the sensor rods.</p>
- PCS
- 1
- IC equipment: Additional eluent on the Eluent Production Module
- 6.5330.090
- Accessory set for Eluent Production Module. Contains all parts necessary for expansion by one eluent. The level sensor must be ordered in accordance with the application.
- <p>Accessory set for Eluent Production Module. Contains all parts necessary for expansion by one eluent. The level sensor must be ordered in accordance with the application.</p>
- PCS
- 1
- Bottle attachment GL 45 for level sensor
- 6.1626.000
- This bottle attachment, fitted with the 6.2769.XXX sensors, results in the level sensors EMPTY and FULL, respectively, for bottles and canisters.
- <p>This bottle attachment, fitted with the 6.2769.XXX sensors, results in the level sensors EMPTY and FULL, respectively, for bottles and canisters.</p>
- PCS
- 1
- Cable for Level Control and Eluent Production Module
- 6.2151.060
- Connecting cable for sensor and Level Control or Eluent Production Module.
- <p>Connecting cable for sensor and Level Control or Eluent Production Module.</p>
- PCS
- 1