Întrebări Frecvente (FAQ)
261 FAQS
- FAQIs the color indicator of the adsorption material harmful?// Suppression
- FAQA standard for the calibration was recorded with the wrong sample type. What should I do?// Database
- FAQI would like to take a measurement in a nonaqueous solution. Which electrolyte can I use in my reference electrode?// Installation of reference electrode// Reference electrode
- FAQWhat preparatory steps need to be taken before shutting down the measuring system?// General problems
- FAQDo norms/standards exist for biodiesel and biodiesel blends?// Method setup-related
- FAQThe peristaltic pump on the sample changer is not transferring the entire sample to the measuring vessel.// Problems with the hardware
- FAQCan users be restricted for making changes, e.g., to methods, sample data, integration, etc.?// Configuration user management
- FAQThe baseline is noisy.// Maintenance Troubleshooting
- FAQThe retention times change with each new eluent. What can I do?// Eluent and standards
- FAQMetrohm Inline Extraction// MISP techniques (Metrohm Inline Sample Preparation)
- FAQWhat is the optimal substance weight for titer determination?// Titer determination
- FAQHow temperature-resistant is the platinum electrode tip?// Rotating disk electrode
- FAQMetrohm intelligent Preconcentration Technique with Matrix Elimination (MiPCT-ME)// MISP techniques (Metrohm Inline Sample Preparation)
- FAQPrinting does not work// General (tiamo)
- FAQCan platinum electrode tips be polished// Maintenance of Rotating Disk Electrodes// Rotating disk electrode
- FAQThe retention times change during the use of an eluent. Why?// Eluent and standards
- FAQHow can I polish my gold RDE?// RDE (Rotating Disk Electrodes)// Maintenance of Rotating Disk Electrodes
- FAQHow to validate my KF titrator?// Validation
- FAQHow often is the molecular sieve to be changed?// Installation// Installation of coulometric cell
- FAQHow do I make sure that my device is stopped at the end of a "Determination series"?// Chromatography
- FAQThe electrode test is failing.// Problems with the measurement
- FAQHow is the database structured?// Database
- FAQInline Spiking// MISP techniques (Metrohm Inline Sample Preparation)
- FAQThe peaks exhibit extreme broadening.// Maintenance Troubleshooting
- FAQWhich reagents are used for KF titration?// Reagents
- FAQMy reference electrode has dried out. Can I regenerate it again?// Maintenance of reference electrodes// Reference electrode// Reference electrode// Maintenance of the reference electrode
- FAQMetrohm Inline Ultrafiltration// MISP techniques (Metrohm Inline Sample Preparation)
- FAQOvertitration took place, i.e., the titrated solution is dark yellow to brown instead of light yellow. How to prevent this?// Sample handling, Sample processing
- FAQWhy are the values found too high?// Sample handling, Sample processing
- FAQHow are the drift, noise, and, e.g., the current conductivity determined during a chromatogram?// Method
- FAQThe evaluation criterion has been reached. However, no results are being displayed.// Problems with Dilution Titration (suppressor determination)
- FAQWhich types of subprograms are there?// Method
- FAQWhat to do to improve the release of water?// Sample handling, Sample processing
- FAQThe peak areas are smaller than expected.// Maintenance Troubleshooting
- FAQIf I view a determination on two different PCs, different times (determination start, etc.) are displayed.// Determinations
- FAQThe more data there is the slower tiamo becomes.// Database
- FAQWhat is the smallest and what is the largest sample amount that I can use for the determination?// Application-related// Preparing the reaction vessel
- FAQThe titration does not finish. What could be the cause?// Sample handling, Sample processing
- FAQJumps appear in the curve and sometimes also result in an incorrect evaluation of the curve. Why is that and can I do something to stop it?// Problems with the execution of a determination
- FAQThe signal is not decreasing despite suppressor addition.// Problems with the measurement
- FAQHow can I start a sample table automatically?// Chromatography
- FAQWhich mercury can I use for polarography?// Installation of Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Installation of Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode
- FAQWhat is an iColumn?// Columns
- FAQIs it possible to delete a client in a client/server environment from the list of registered clients?// Client server
- FAQCan Metrohm polish platinum electrode tips?// Maintenance of Rotating Disk Electrodes// Rotating disk electrode
- FAQStatistics series is reset, even though the series has not ended.// Process
- FAQWhat is "Dosino Regeneration"?// Suppression
- FAQIndividual peaks are too large.// Maintenance Troubleshooting
- FAQPoor reproducibility of the titer determination with water// Titer determination
- FAQCan I set up backup as a service?// Backup
- FAQWhen the screen saver disappears, tiamo is grayed out, and I don't see any elements − just the window frame.// General (tiamo)
- FAQI am getting an error message that the dosing unit data cannot be read.// Problems with the hardware
- FAQWhich calibration option should I choose for "Reprocessing" of determinations?// Database
- FAQI am getting negative or no results.// Problems with MLAT LAT (brightener determination)
- FAQMetrohm Inline Eluent Preparation// MISP techniques (Metrohm Inline Sample Preparation)
- FAQIs it possible to regenerate IC separation columns?// Columns
- FAQThe measurement curves are noisy. What is the reason for that?// General problems
- FAQThe titration ends although no equivalence point – or at least not the expected equivalence point – has been found.// General
- FAQThe measurement curves are noisy.// Problems with the measurement
- FAQThe baseline is drifting excessively.// Maintenance Troubleshooting
- FAQHow often should the titer be determined?// Titer determination
- FAQHow do I protect the suppressor?// Suppression
- FAQIs MagIC Net FDA- and GMP-compliant?// MagIC Net
- FAQCan a PC be used that is tied to a domain structure?// Installation
- FAQWhere can I find more information on the topic of mercury and health?// Multi-Mode Electrode, Multi-Mode Electrode pro// Mercury handling
- FAQDoes the Pt RDE diameter affect my analysis results?// Rotating disk electrode
- FAQDoes the gas flow affect my result?// Method setup-related
- FAQWhich adaptations and changes does the tiamo installer carry out during installation?// Installation
- FAQHow can I restore the databases?// Backup
- FAQIt takes a long time to open databases or the database manager.// Determinations
- FAQRenaming of a database fails, and an error message appears stating that the database is in use.// Database
- FAQWhen is the status «last backup» entered in databases in tiamo?// Backup
- FAQMetrohm intelligent Pick-up Technique (MiPuT)// MISP techniques (Metrohm Inline Sample Preparation)
- FAQHow should I select user rights in the file system and the registry?// General (tiamo)
- FAQWhy do I need the parameter temperature correction (Delta T) in my method?// Method setup-related
- FAQMy sample foams and therefore gets into the measuring vessel. What should I do?// Problems with the execution of a determination
- FAQPower failure with tiamo client/server// Client server
- FAQHow can I clean a blocked dosing unit?// Dosinos
- FAQWhat are (logical) conditions?// Method
- FAQWhat are "Common variables" and how are they used?// Method
- FAQI would like to determine the oxidation stability of a plant oil. Which method should I use and will I need any special accessories?// Method setup-related
- FAQWhich resolution should my balance have?// Installation
- FAQIs there a risk of carryover if I use the Dosino for sample input?// Dosinos
- FAQWhat nitrogen pressure do I need to operate the Multi-Mode Electrode?// Installation of Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Installation of Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode
- FAQThe dosing unit is blocked and/or leaking.// Problems with the hardware
- FAQCan the recovery rate be calculated automatically with MagIC Net?// Method
- FAQThe pressure in the system has noticeably decreased.// Maintenance Troubleshooting
- FAQIf I change a view in the database, close the database, and then reopen it, the old view comes up − not the new one.// Determinations
- FAQHow should the additives be stored?// General problems
- FAQHow does the Reconnect work?// Client server
- FAQMeasuring the electrolyte value is taking a long time or is not completed.// Problems with Response Curve (leveler determination)
- FAQWith Titrino, 700 Dosino is displayed as 685 but works perfectly// General (tiamo)
- FAQHow do I know when something is wrong with my conductivity measuring cell?// Hardware-related// Preparing the measuring vessel
- FAQHow can I find the correct electrode for my titration application?// General
- FAQThe result disappears after recalculation.// Determinations
- FAQBackup is not working as required.// Backup
- FAQConditioning is taking a long time.// Problems with the measurement
- FAQHow can I polish my Ultra-Trace RDE?// RDE (Rotating Disk Electrodes)// Maintenance of Rotating Disk Electrodes
- FAQHow do I use the example methods supplied with MagIC Net?// Method
- FAQChloride interferes with my determination. Can I use another electrolyte instead of KCl?// Installation of reference electrode// Reference electrode
- FAQHow do I register devices or modules in MagIC Net?// MagIC Net
- FAQTo what must I pay particular attention when using IC columns?// Columns
- FAQDoes Metrohm offer service agreements?// Maintenance Troubleshooting
- FAQWhat is actually installed during installation?// Installation
- FAQHow do I store the IC column when it is not in use?// Columns
- FAQHow much mercury can I use to fill the Multi-Mode Electrode?// Installation of Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Installation of Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode
- FAQPreparing the Dosinos is taking a long time. Is it possible to speed up this step?// General problems
- FAQCan I automate the injection of a check standard after a certain number of sample measurements (e.g., 10)?// Method
- FAQWhich standard solutions can be used in ion chromatography?// Eluent and standards
- FAQHow are the Metrohm Service technicians qualified?// Maintenance Troubleshooting
- FAQHow often is the KF working medium to be changed?// Sample handling, Sample processing
- FAQThe pump on my instrument is extremely loud. Is that normal?// Problems with the execution of a determination
- FAQWith which Windows™ versions is MagIC Net compatible?// MagIC Net
- FAQHow can I polish my platinum RDE?// RDE (Rotating Disk Electrodes)// Maintenance of Rotating Disk Electrodes
- FAQWhat measures are recommended when the volumetric Karl Fischer titrator will not be used or has not been used for a prolonged period?// Installation
- FAQThe membrane pumps of the 843 Pump Station are not operating at full pump capacity.// Problems with the hardware
- FAQThe integration is marked as "Manual" in the determination. How can I find out which peak was integrated manually?// Database
- FAQHow do I find out whether a particular separation column is suitable for my tasks?// Columns
- FAQHow often do I need to change the reference electrolyte?// Maintenance of reference electrodes// Reference electrode
- FAQHow can I determine the reproducibility of a multiple injection?// Method
- FAQIf I select one or more determinations from the database, open the dialog window «Control chart» and move this window, this (sometimes) creates lines in parallel with the axes (either in the subwindow «Graphs» or even on the actual control card!).// Determinations
- FAQWhich dosing unit should I choose?// Dosinos
- FAQInline Calibration// MISP techniques (Metrohm Inline Sample Preparation)
- FAQThe retention times are not reproducible.// Maintenance Troubleshooting
- FAQWhich maintenance work can I carry out myself?// Maintenance Troubleshooting
- FAQMagIC Net is slowing down. What can I do to prevent this?// MagIC Net
- FAQMetrohm intelligent Preconcentration Technique (MiPCT)// MISP techniques (Metrohm Inline Sample Preparation)
- FAQWhat do I need to keep in mind when positioning the air tube in the reaction vessel?// Hardware-related// Preparing the reaction vessel
- FAQI would like to determine the oxidation stability of a biodiesel blend. Which method should I use and will I need any special accessories?// Method setup-related
- FAQHow can I polish my glassy carbon RDE?// RDE (Rotating Disk Electrodes)// Maintenance of Rotating Disk Electrodes
- FAQWhat is actually stored in a determination?// Determinations
- FAQThe titration curve shows a flat line, i.e., no change in signal.// General
- FAQWhich MagIC Net versions are there?// MagIC Net
- FAQThe volumetric Karl Fischer titration is very slow// Sample handling, Sample processing
- FAQThe result is higher than expected.// General
- FAQHow is the data transmitted?// Database
- FAQThe electrode surface of the auxiliary electrode is coated with a foreign metal (Cu, Sn, etc.). What can I do?// Maintenance of auxiliary electrodes// Auxiliary electrode
- FAQHow frequently do the electrodes need to be conditioned?// General problems
- FAQCan I use a Dosino for eluent preparation (Eluent Dosino), for Liquid Handling, and for Suppressor Regeneration?// Dosinos
- FAQVarious sample changers (e.g., 814 with 5.814.0023) cannot be updated (firmware).// General (tiamo)
- FAQCan I inject samples from one sampler into two IC systems that are independent of one another?// Chromatography
- FAQAfter installation user rights were different, in that the user logged on during installation has full (or special) rights.// Installation
- FAQHow should the electrodes be stored?// General problems
- FAQHow do I use the MCS?// Suppression
- FAQCan registered users be deleted from MagIC Net?// MagIC Net
- FAQHow can databases be backed up?// Database
- FAQHow do I protect the column against particles and unwanted components?// Columns
- FAQWhich tiamo versions work with which Windows versions?// General (tiamo)
- FAQCan I reuse the reaction vessel?// Hardware-related// Preparing the reaction vessel
- FAQConditioning is taking a long time and a standard deviation < 0.5% cannot be achieved.// Problems with Dilution Titration (suppressor determination)
- FAQThe background conductivity is too high.// Maintenance Troubleshooting
- FAQMetrohm Inline Dialysis// MISP techniques (Metrohm Inline Sample Preparation)
- FAQI am getting non-reproducible measurement curves (cyclic voltammogram).// Problems with MLAT LAT (brightener determination)
- FAQHow can I check that my "Sample data" in a "Sample table" are complete?// Chromatography
- FAQMetrohm intelligent Partial Loop Injection Technique (MiPT)// MISP techniques (Metrohm Inline Sample Preparation)
- FAQThe electrode surface of the platinum electrode tip is coated with a foreign metal (Cu, Sn, etc.). What can I do?// Maintenance of Rotating Disk Electrodes// Rotating disk electrode
- FAQWhere to buy KF reagents?// Reagents
- FAQDoes the position of the PTFE tubing in the measuring vessel play a role?// Hardware-related// Preparing the measuring vessel
- FAQWhat to do if the pump is not working correctly?// Installation
- FAQHow much sample to weigh in?// Sample handling, Sample processing
- FAQThe status LED of the 800 Dosino is flashing quickly and the dosing unit is not being recognized.// Problems with the hardware
- FAQWhat do I need in order to prepare eluents?// Eluent and standards
- FAQHow often should my KF titrator be validated?// Validation
- FAQI would like to determine the thermostability of PVC. Which method should I use and will I need any special accessories?// Method setup-related
- FAQAt what intervals should a dosing unit be cleaned?// General problems
- FAQWhat to do if the drift is too high?// Sample handling, Sample processing// Conditioning the volumetric cell// Conditioning the coulometric cell
- FAQDoes a Metrohm IC system have a maintenance manual?// Maintenance Troubleshooting
- FAQHow dangerous is handling mercury?// Installation of Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Installation of Multi-Mode Electrode pro// Mercury handling// Maintenance of the Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode
- FAQHow can I create a new calibration from already recorded standards in which the component assignment was not correct?// Database
- FAQThe measured values exhibit excessive scattering.// Maintenance Troubleshooting
- FAQThe result is lower than expected.// General
- FAQDo norms/standards exist for oil and fat samples?// Method setup-related
- FAQMetrohm Inline Dilution Technique (MIDT)// MISP techniques (Metrohm Inline Sample Preparation)
- FAQHow are Dosinos used in ion chromatography?// Dosinos
- FAQHow is the MSM operated?// Suppression
- FAQHow is the raw data of a determination handled? Is it always available?// Database
- FAQI have adjusted the method under "Reprocessing", but the next determinations are still being recorded with the old parameters.// Chromatography
- FAQTo what must I pay particular attention for the MSM?// Suppression
- FAQCan I use a screen saver with MagIC Net?// MagIC Net
- FAQPoor reproducibility of the results// Sample handling, Sample processing
- FAQHow often should the dosing units be prepared?// General problems
- FAQHow to regenerate the molecular sieve?// Installation// Installation of coulometric cell
- FAQCan an individual determination be exported?// Database
- FAQDoes the volume of the measuring solution play a role when determining the induction time?// Application-related// Preparing the measuring vessel
- FAQThe reproducibility of results is worse than expected.// Problems with MLAT LAT (brightener determination)
- FAQHow can I check that my "Sample data" is complete?// Chromatography
- FAQHow to recognize a side reaction?// Sample handling, Sample processing
- FAQI am getting an error message. The 800 Dosino cannot be actuated by the 894 Professional CVS.// Problems with the hardware
- FAQWhat nitrogen quality do I need for polarography/voltammetry?// Installation of Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Installation of Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode pro// Maintenance of the Multi-Mode Electrode
- FAQCan MagIC Net databases be created, renamed, or deleted?// MagIC Net
- FAQHow do I clean my platinum electrode tip?// Maintenance of Rotating Disk Electrodes// Rotating disk electrode
- FAQCan the limit of detection be calculated automatically in MagIC Net?// MagIC Net
- FAQWhich data is global and which is client-specific?// Database
- FAQThe pressure in the system has noticeably increased.// Maintenance Troubleshooting
- FAQCan measurements made using other software be used in viva?// General problems
- FAQDoes the accuracy of the sample weight affect the result?// Application-related// Preparing the reaction vessel
- FAQDo I need to determine the cell constant of my conductivity measuring cell?// Hardware-related// Preparing the measuring vessel
- FAQDoes the sample temperature affect my result?// Method setup-related
- FAQWhat does a "Method" contain?// Method
- FAQAn electrode connector on the electrode cable is broken.// Problems with the hardware