FAQ Finder
261 FAQS
- FAQWhich adaptations and changes does the tiamo installer carry out during installation?// Instalacja
- FAQWhen is the status «last backup» entered in databases in tiamo?// Kopia zapasowa
- FAQMetrohm intelligent Pick-up Technique (MiPuT)// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQHow should I select user rights in the file system and the registry?// Ogólne (tiamo)
- FAQHow to recognize a side reaction?// Obsługa próbek, praca z roztworami
- FAQUntil now, I have always used diluted H2SO4 as a bridge electrolyte. Can I use another electrolyte instead of KNO3?// Konserwacja elektrod odniesienia// Elektroda referencyjna
- FAQThe titration curve shows an unstable measuring signal and/or significant outliers (peaks).// Ogólne
- FAQWhy do I need the parameter temperature correction (Delta T) in my method?// Związane z konfiguracją metody
- FAQMy sample foams and therefore gets into the measuring vessel. What should I do?// Problemy z przeprowadzeniem oznaczenia
- FAQI am getting an error message. The 800 Dosino cannot be actuated by the 894 Professional CVS.// Problemy ze sprzętem
- FAQPower failure with tiamo client/server// Klient serwer
- FAQThe measurement of the intercept value is taking a long time or is not completed.// Problemy z MLAT LAT (oznaczenie rozjaśniacza)
- FAQWhat are (logical) conditions?// Metoda
- FAQWhat nitrogen quality do I need for polarography/voltammetry?// Instalacja elektrody Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Instalacja elektrody Multi-Mode Electrode// Konserwacja elektrody Multi-Mode Electrode pro// Konserwacja elektrody Multi-Mode Electrode
- FAQIs there a risk of carryover if I use the Dosino for sample input?// Jednostki dozujące Dosino
- FAQI would like to determine the oxidation stability of a plant oil. Which method should I use and will I need any special accessories?// Związane z konfiguracją metody
- FAQCan MagIC Net databases be created, renamed, or deleted?// Oprogramowanie MagIC Net
- FAQWhat are "Common variables" and how are they used?// Metoda
- FAQHow do I clean my platinum electrode tip?// Konserwacja elektrod krążkowych// Obrotowa elektroda dyskowa
- FAQCan the limit of detection be calculated automatically in MagIC Net?// Oprogramowanie MagIC Net
- FAQWhat nitrogen pressure do I need to operate the Multi-Mode Electrode?// Instalacja elektrody Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Instalacja elektrody Multi-Mode Electrode// Konserwacja elektrody Multi-Mode Electrode pro// Konserwacja elektrody Multi-Mode Electrode
- FAQWhich data is global and which is client-specific?// Baza danych
- FAQWhere is the data to be found in tiamo?// Baza danych
- FAQIf I change a view in the database, close the database, and then reopen it, the old view comes up − not the new one.// Oznaczenia
- FAQThe pressure in the system has noticeably decreased.// Konserwacja i rozwiązywanie problemów
- FAQThe pressure in the system has noticeably increased.// Konserwacja i rozwiązywanie problemów
- FAQCan measurements made using other software be used in viva?// Ogólne problemy
- FAQWith Titrino, 700 Dosino is displayed as 685 but works perfectly// Ogólne (tiamo)
- FAQMeasuring the electrolyte value is taking a long time or is not completed.// Problemy z krzywą odpowiedzi (określenie niwelatora)
- FAQHow should the additives be stored?// Ogólne problemy
- FAQHow does the Reconnect work?// Klient serwer
- FAQHow do I know when something is wrong with my conductivity measuring cell?// Związane ze sprzętem// Przygotowanie naczynia pomiarowego
- FAQHow do I use the example methods supplied with MagIC Net?// Metoda
- FAQDoes Metrohm offer service agreements?// Konserwacja i rozwiązywanie problemów
- FAQPreparing the Dosinos is taking a long time. Is it possible to speed up this step?// Ogólne problemy
- FAQWhat does a "Method" contain?// Metoda
- FAQAn electrode connector on the electrode cable is broken.// Problemy ze sprzętem
- FAQHow do I store the IC column when it is not in use?// Kolumny
- FAQHow much mercury can I use to fill the Multi-Mode Electrode?// Instalacja elektrody Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Instalacja elektrody Multi-Mode Electrode// Konserwacja elektrody Multi-Mode Electrode pro// Konserwacja elektrody Multi-Mode Electrode
- FAQWhich standard solutions can be used in ion chromatography?// Eluent i wzorce
- FAQHow are the Metrohm Service technicians qualified?// Konserwacja i rozwiązywanie problemów
- FAQThe pump on my instrument is extremely loud. Is that normal?// Problemy z przeprowadzeniem oznaczenia
- FAQWith which Windows™ versions is MagIC Net compatible?// Oprogramowanie MagIC Net
- FAQThe curve obtained from the sample looks different to that from the calibration.// Problemy z rozcieńczaniem
- FAQHow can I polish my platinum RDE?// Elektrody krążkowe RDE (Rotating Disk Electrodes)// Konserwacja elektrod krążkowych Rotating Disk Electrodes
- FAQI always have Reconnect problems.// Klient serwer
- FAQThe membrane pumps of the 843 Pump Station are not operating at full pump capacity.// Problemy ze sprzętem
- FAQThe integration is marked as "Manual" in the determination. How can I find out which peak was integrated manually?// Baza danych
- FAQThe measuring signal in VMS is exceptionally small and conditioning in VMS is taking a long time. What is the reason for that?// Ogólne problemy
- FAQHow do I find out whether a particular separation column is suitable for my tasks?// Kolumny
- FAQHow often do I need to change the reference electrolyte?// Konserwacja elektrod odniesienia// Elektroda referencyjna
- FAQHow can I determine the reproducibility of a multiple injection?// Metoda
- FAQIf I select one or more determinations from the database, open the dialog window «Control chart» and move this window, this (sometimes) creates lines in parallel with the axes (either in the subwindow «Graphs» or even on the actual control card!).// Oznaczenia
- FAQWhich dosing unit should I choose?// Jednostki dozujące Dosino
- FAQHow to clean the indicator electrode?// Instalacja
- FAQInline Calibration// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQAfter [Stop] the Exit track is not run, and no data is entered into the database.// Proces
- FAQThe retention times are not reproducible.// Konserwacja i rozwiązywanie problemów
- FAQWhich maintenance work can I carry out myself?// Konserwacja i rozwiązywanie problemów
- FAQMetrohm Inline Matrix Elimination// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQWhat do I need to keep in mind when positioning the air tube in the reaction vessel?// Związane ze sprzętem// Przygotowanie naczynia reakcyjnego
- FAQI would like to determine the oxidation stability of a biodiesel blend. Which method should I use and will I need any special accessories?// Związane z konfiguracją metody
- FAQDo norms/standards exist for PVC samples?// Związane z konfiguracją metody
- FAQDeletion of data records does not make the database smaller.// Oznaczenia
- FAQRise in the values during titer determination with disodium tartrate dihydrate// Wyznaczanie miana
- FAQThe titration curve shows a flat line, i.e., no change in signal.// Ogólne
- FAQWhich MagIC Net versions are there?// Oprogramowanie MagIC Net
- FAQThe volumetric Karl Fischer titration is very slow// Obsługa próbek, praca z roztworami
- FAQIs the "Audit Trail" always active?// Konfiguracja zarządzanie użytkownikami
- FAQHow is the data transmitted?// Baza danych
- FAQWhat can I do to improve the reproducibility of the results?// Problemy z przeprowadzeniem oznaczenia
- FAQHow should the Titrino and the 756/831 KF Coulometer be set so that the equipment works perfectly with tiamo?// Ogólne (tiamo)
- FAQHow frequently do the electrodes need to be conditioned?// Ogólne problemy
- FAQThe following error occurs: «Restoration not possible (015-137). Problems copying the database. Restoration cannot be carried out at present. Try again later.»// Kopia zapasowa
- FAQVarious sample changers (e.g., 814 with 5.814.0023) cannot be updated (firmware).// Ogólne (tiamo)
- FAQCan I use a Dosino for eluent preparation (Eluent Dosino), for Liquid Handling, and for Suppressor Regeneration?// Jednostki dozujące Dosino
- FAQCan I inject samples from one sampler into two IC systems that are independent of one another?// Chromatografia
- FAQAfter installation user rights were different, in that the user logged on during installation has full (or special) rights.// Instalacja
- FAQHow to prevent side reactions?// Obsługa próbek, praca z roztworami
- FAQWhat are subprograms?// Metoda
- FAQSolution is leaking between the 894 Professional CVS and the measuring head.// Problemy ze sprzętem
- FAQHow should the electrodes be stored?// Ogólne problemy
- FAQHow do I use the MCS?// Supresja
- FAQCan registered users be deleted from MagIC Net?// Oprogramowanie MagIC Net
- FAQWith manual graph evaluation the EP is not plotted if I have selected ERC as the y1 axis.// Oznaczenia
- FAQHow do I treat fusible solid samples?// Związane z aplikacjami// Przygotowanie naczynia reakcyjnego
- FAQIs polishing the platinum pin of the auxiliary electrode allowed?// Konserwacja elektrod pomocniczych// Elektroda pomocnicza
- FAQThe measured values are widely scattered.// Problemy z pomiarem
- FAQHow can databases be backed up?// Baza danych
- FAQHow do I protect the column against particles and unwanted components?// Kolumny
- FAQTo what must I pay particular attention when using MagIC Net on my computer?// Oprogramowanie MagIC Net
- FAQHow can I retrospectively change the client ID?// Konfiguracja
- FAQCan I reuse the reaction vessel?// Związane ze sprzętem// Przygotowanie naczynia reakcyjnego
- FAQConditioning is taking a long time and a standard deviation < 0.5% cannot be achieved.// Problemy z rozcieńczaniem
- FAQIs the color indicator of the adsorption material harmful?// Supresja
- FAQEver since updating from tiamo 1.X to tiamo 2.X other Metrohm programs no longer work properly, and devices are no longer recognized.// Ogólne (tiamo)
- FAQWhat preparatory steps need to be taken before shutting down the measuring system?// Ogólne problemy
- FAQMetrohm Inline Dialysis// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQWhich precautions should I take when using peristaltic pumps?// Pompa perystaltyczna
- FAQI would like to take a measurement in a nonaqueous solution. Which electrolyte can I use in my reference electrode?// Instalacja elektrody odniesienia// Elektroda referencyjna
- FAQThe peristaltic pump on the sample changer is not transferring the entire sample to the measuring vessel.// Problemy ze sprzętem
- FAQCan users be restricted for making changes, e.g., to methods, sample data, integration, etc.?// Konfiguracja zarządzanie użytkownikami
- FAQHow can I check that my "Sample data" in a "Sample table" are complete?// Chromatografia
- FAQI am getting non-reproducible measurement curves (cyclic voltammogram).// Problemy z MLAT LAT (oznaczenie rozjaśniacza)
- FAQThe retention times change with each new eluent. What can I do?// Eluent i wzorce
- FAQWhen are the septum and the O-rings/PTFE sleeves to be changed?// Instalacja
- FAQHow is the Dosino assigned to a particular function?// Jednostki dozujące Dosino
- FAQWhat is the optimal substance weight for titer determination?// Wyznaczanie miana
- FAQMetrohm intelligent Partial Loop Injection Technique (MiPT)// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQWhat are the order numbers for the consumables?// Instalacja
- FAQHow temperature-resistant is the platinum electrode tip?// Obrotowa elektroda dyskowa
- FAQThe electrode surface of the platinum electrode tip is coated with a foreign metal (Cu, Sn, etc.). What can I do?// Konserwacja elektrod krążkowych// Obrotowa elektroda dyskowa
- FAQCan platinum electrode tips be polished// Konserwacja elektrod krążkowych// Obrotowa elektroda dyskowa
- FAQHow to service the Dosing and the Exchange Unit? (for volumetric KF titration)// Instalacja
- FAQPrinting does not work// Ogólne (tiamo)
- FAQWhere can I find information on spare parts for the Multi-Mode Electrode and the Multi-Mode Electrode pro?// Instalacja elektrody Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Instalacja elektrody Multi-Mode Electrode// Konserwacja elektrody Multi-Mode Electrode pro// Konserwacja elektrody Multi-Mode Electrode
- FAQThe retention times change during the use of an eluent. Why?// Eluent i wzorce
- FAQHow can I polish my gold RDE?// Elektrody krążkowe RDE (Rotating Disk Electrodes)// Konserwacja elektrod krążkowych Rotating Disk Electrodes
- FAQHow often is the molecular sieve to be changed?// Instalacja// Instalacja celi kulometrycznej
- FAQHow much sample to weigh in?// Obsługa próbek, praca z roztworami
- FAQThe status LED of the 800 Dosino is flashing quickly and the dosing unit is not being recognized.// Problemy ze sprzętem
- FAQHow do I make sure that my device is stopped at the end of a "Determination series"?// Chromatografia
- FAQHow often does the bridge electrolyte need changing?// Konserwacja elektrod odniesienia// Elektroda referencyjna
- FAQThe electrode test is failing.// Problemy z pomiarem
- FAQWhat do I need in order to prepare eluents?// Eluent i wzorce
- FAQWhere to buy KF reagents?// Odczynniki
- FAQHow is the database structured?// Baza danych
- FAQHow often should my KF titrator be validated?// Walidacja
- FAQThe peaks exhibit extreme broadening.// Konserwacja i rozwiązywanie problemów
- FAQInline Spiking// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQWhich reagents are used for KF titration?// Odczynniki
- FAQMy reference electrode has dried out. Can I regenerate it again?// Konserwacja elektrod odniesienia// Elektroda referencyjna// Elektroda referencyjna// Konserwacja elektrod referencyjnych
- FAQMetrohm Inline Ultrafiltration// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQI would like to determine the thermostability of PVC. Which method should I use and will I need any special accessories?// Związane z konfiguracją metody
- FAQAt what intervals should a dosing unit be cleaned?// Ogólne problemy
- FAQHow are the drift, noise, and, e.g., the current conductivity determined during a chromatogram?// Metoda
- FAQA different reference electrode is used in my application description. Can I use the Ag/AgCl reference electrode anyway?// Instalacja elektrody odniesienia// Elektroda referencyjna
- FAQWhen installing clients in client/server systems (tiamo multi) you must always be logged onto the server in Windows.// Klient serwer
- FAQHow often is the Dosing/Exchange Unit to be prepared (Preparing/«Prep» function)? (for volumetric KF titration)// Instalacja
- FAQMetrohm Inline Cation Removal// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQWhat to do if the drift is too high?// Obsługa próbek, praca z roztworami// Kondycjonowanie celki wolumetrycznej// Kondycjonowanie celki kulometrycznej
- FAQWhich types of subprograms are there?// Metoda
- FAQHow dangerous is handling mercury?// Instalacja elektrody Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Instalacja elektrody Multi-Mode Electrode// Postępowanie z rtęcią// Konserwacja elektrody Multi-Mode Electrode pro// Konserwacja elektrody Multi-Mode Electrode
- FAQI observe increased peak broadening although the column is new. What could be the cause?// Połączenia
- FAQCan the usual Windows patches and updates be installed without affecting the system?// Instalacja
- FAQWhat to do to improve the release of water?// Obsługa próbek, praca z roztworami
- FAQHow can I create a new calibration from already recorded standards in which the component assignment was not correct?// Baza danych
- FAQThe peak is no longer recognized.// Problemy z pomiarem
- FAQHow can the entire calibration be transferred to all standards?// Baza danych
- FAQThe measured values exhibit excessive scattering.// Konserwacja i rozwiązywanie problemów
- FAQIf I view a determination on two different PCs, different times (determination start, etc.) are displayed.// Oznaczenia
- FAQThe more data there is the slower tiamo becomes.// Baza danych
- FAQWhat is the smallest and what is the largest sample amount that I can use for the determination?// Związane z aplikacjami// Przygotowanie naczynia reakcyjnego
- FAQMetrohm Inline Neutralization// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQThe titration does not finish. What could be the cause?// Obsługa próbek, praca z roztworami
- FAQCan I determine the shelf life of my sample using the Rancimat?// Ogólne
- FAQJumps appear in the curve and sometimes also result in an incorrect evaluation of the curve. Why is that and can I do something to stop it?// Problemy z przeprowadzeniem oznaczenia
- FAQThe result is lower than expected.// Ogólne
- FAQCan I reuse the reaction vessel cover?// Związane ze sprzętem// Przygotowanie naczynia reakcyjnego
- FAQThe signal is not decreasing despite suppressor addition.// Problemy z pomiarem
- FAQDo norms/standards exist for oil and fat samples?// Związane z konfiguracją metody
- FAQHow can I start a sample table automatically?// Chromatografia
- FAQWhich mercury can I use for polarography?// Instalacja elektrody Multi-Mode Electrode pro// Multi-Mode Electrode, Multi-Mode Electrode pro// Instalacja elektrody Multi-Mode Electrode// Konserwacja elektrody Multi-Mode Electrode pro// Konserwacja elektrody Multi-Mode Electrode
- FAQIs it possible to delete a client in a client/server environment from the list of registered clients?// Klient serwer
- FAQWhat is an iColumn?// Kolumny
- FAQMetrohm Inline Dilution Technique (MIDT)// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQCan Metrohm polish platinum electrode tips?// Konserwacja elektrod krążkowych// Obrotowa elektroda dyskowa
- FAQHow are Dosinos used in ion chromatography?// Jednostki dozujące Dosino
- FAQStatistics series is reset, even though the series has not ended.// Proces
- FAQIndividual peaks are too large.// Konserwacja i rozwiązywanie problemów
- FAQHow can I check my "Method"?// Metoda
- FAQCan I set up backup as a service?// Kopia zapasowa
- FAQPoor reproducibility of the titer determination with water// Wyznaczanie miana
- FAQWhen the screen saver disappears, tiamo is grayed out, and I don't see any elements − just the window frame.// Ogólne (tiamo)
- FAQHow is the raw data of a determination handled? Is it always available?// Baza danych
- FAQI am getting an error message that the dosing unit data cannot be read.// Problemy ze sprzętem
- FAQMetrohm Inline Eluent Preparation// techniki MISIP (Metrohm Inline Sample Preparation)
- FAQWhich calibration option should I choose for "Reprocessing" of determinations?// Baza danych
- FAQIs it possible to regenerate IC separation columns?// Kolumny
- FAQThe measurement curves are noisy. What is the reason for that?// Ogólne problemy
- FAQTo what must I pay particular attention for the MSM?// Supresja
- FAQThe titration ends although no equivalence point – or at least not the expected equivalence point – has been found.// Ogólne
- FAQCan I use the Windows firewall, and how should I set it?// Ogólne (tiamo)
- FAQThe measurement curves are noisy.// Problemy z pomiarem
- FAQThe baseline is drifting excessively.// Konserwacja i rozwiązywanie problemów
- FAQPoor reproducibility of the results// Obsługa próbek, praca z roztworami
- FAQHow often should the titer be determined?// Wyznaczanie miana
- FAQHow do I protect the suppressor?// Supresja
- FAQHow often should the dosing units be prepared?// Ogólne problemy
- FAQCan a PC be used that is tied to a domain structure?// Instalacja
- FAQHow to regenerate the molecular sieve?// Instalacja// Instalacja celi kulometrycznej
- FAQIs MagIC Net FDA- and GMP-compliant?// Oprogramowanie MagIC Net
- FAQWhere can I find more information on the topic of mercury and health?// Multi-Mode Electrode, Multi-Mode Electrode pro// Postępowanie z rtęcią
- FAQCan an individual determination be exported?// Baza danych
- FAQHow can I restore the databases?// Kopia zapasowa
- FAQDoes the volume of the measuring solution play a role when determining the induction time?// Związane z aplikacjami// Przygotowanie naczynia pomiarowego
- FAQIt takes a long time to open databases or the database manager.// Oznaczenia
- FAQDoes the gas flow affect my result?// Związane z konfiguracją metody
- FAQPoor reproducibility of the titer determination with disodium tartrate dihydrate// Wyznaczanie miana
- FAQPotassium interferes with my determination. Can I use another electrolyte instead of KCl?// Instalacja elektrody odniesienia// Elektroda referencyjna