Application Finder
- 8.000.6079Automated Karl Fischer titration for liquid samples using edible oils as an example
The poster describes the development of an automated Karl Fischer method for determining the water content in different edible oils.
- AN-PAN-1039Ortho- and total phosphate phosphorus analysis online according to EN ISO 6878
Phosphorus removal is essential in waste water treatment plants to ensure the environmental balance is not upset by discharged effluent. In the treatment facility it is important to know the bioavailable o-phosphate phosphorus (o-PO4-P) concentration in the influent stream either to feed bacteria or to calculate the amount of reagents needed for chemical treatment. For environmental compliance monitoring purposes, treated effluent is monitored for TP – the sum of all insoluble and dissolved phosphates present. With the Metrohm Process Analytics 2035 TP Analyzer (complete with integrated compact digestion cuvette photometer module), you can keep track of both o-PO4-P and TP according to DIN EN ISO 6878:2004-09 around the clock.
- AB-076Polarographic determination of nitrilotriacetic acid (NTA) and ethylenediaminetetraacetic acid (EDTA) according to DIN 38413 part 5
According to the described method, NTA and EDTA can be determined in mass concentrations of 0.05 mg/L up to 25 mg/L in polluted water and wastewater.At first NTA and EDTA are converted to the corresponding Bi complexes by addition of Bi3+ ions at a pH value of 2.0. As these Bi complexes have significantly different peak potentials, they can be determined simultaneously by DP polarography. The interfering anions nitrite, sulfite, and sulfide are removed from the sample by acidification and purging. Interfering cations are removed by cation exchange; any NTA or EDTA heavy metal complexes present in the sample are disintegrated during this procedure. To remove surfactants and other organic components interfering with the analysis, the sample solution is run through a column filled with non-polar adsorber resin.
- AN-C-192Cations in sodium rich wastewater
Wastewaters often contain high loads of sodium, making the determination of minor cations quite a challenge. In the present wastewater study, the determination of lithium, ammonium, zinc, strontium, and barium is requested. If the sodium concentration exceeds 2 g/L, this negatively influences the peak shape of closely eluting peaks. Applying a appropriate dilution factor to the sample enables the quantification of minor cations. Therefore zinc and barium can be properly quantified with a dilution ratio of 1:2, while lithium and ammonium require minimum dilution factors of at least 1:10 and 1:100, respectively.
- AN-NIR-095Quality Control of Hand Sanitizers
This application note presents near-infrared spectroscopy (NIRS) for the rapid and reliable simultaneous quantification of ethanol, glycerol, hydrogen peroxide, and water content in hand sanitizer formulations.
- AN-NIR-104Analysis of green coffee beans by near-infrared spectroscopy
Near-infrared spectroscopy (NIRS) is a fast, chemical-free analytical method for the simultaneous analysis of density, water activity, and moisture of green coffee beans.
- AN-C-158Column stability of the Metrosep C 6 - 250/4.0 with Inline Ultrafiltration and Inline Eluent Preparation
The column stability of the Metrosep C 6 - 250/4.0 was determined in long-term laboratory tests. Two injection series per day were run on each of six days in a row. Each series was comprised of nine tap water injections, three check standard injections and six tap water injections. The IC system was shut down on the seventh day of each series. As a whole, the system ran over 10 weeks and counted a total of 2,150 injections. The results show an outstanding reproducibility and verify the high column stability.
- WP-023Karl Fischer titration and near-infrared spectroscopy in perfect synergy
Metrohm has shaped moisture analysis for more than half a century. Find out about new developments in water analysis and learn how near-infrared spectroscopy in combination with Karl Fischer titration can increase your sample throughput and boost your productivity.
- AN-NIR-021Monitoring the purity of recovered solvents with NIRS
The purity of a recovered solvent (dichlormethane/methylene chloride) and two of its most important contaminants (methanol and water) are monitored with NIR spectroscopy.
- AN-V-125Iron traces with 1-nitroso-2-naphthol
The concentration of Fe is determined in water samples by adsorptive stripping voltammetry with 1-nitroso-2-naphthol as complexing agent. All reagents have to be added in the order as listed below. All reagents typically contain iron impurities. Therefore a subtraction of the reagent blank is recommended. Fe(II) and Fe(III) show different sensitivities. Therefore the sample should only contain one of the iron species. Ascorbic acid (Vitamin C) can be added to the measuring solution and to the Fe(III) standard solution if both Fe(II) and Fe(III) are present in the sample to determine the concentration of total iron. A final concentration of ascorbic acid of 0.002 mol/L is suitable.
- WP-066An introduction to ion chromatography mass spectrometry (IC-MS)
Ion chromatography mass spectrometry (IC-MS) is a powerful tool that can handle many challenging analytical tasks which cannot be performed adequately by IC alone. IC-MS is a robust, sensitive, and selective technique used for the determination of polar contaminants like inorganic anions, organic acids, haloacetic acids, oxyhalides, or alkali and alkaline earth metals. After separation of the sample components via IC, mass selective detection guarantees peak identity with low detection limits. The inclusion of automated Metrohm Inline Sample Preparation (MISP) allows not only water samples, but also chemicals, organic solvents, or post-explosion residues to be readily analyzed without need for extensive manual laboratory work. This White Paper explains the benefits of IC-MS over IC in certain cases, the hyphenation of IC and different MS systems, as well as related norms and standards.
- AN-NIR-132Almond analysis with near-infrared (NIR) spectroscopy
This Application Note shows how NIR spectroscopy is used to determine the water content (moisture content), protein content, and fat content in whole and ground almonds.
- AN-NIR-053Moisture analysis of ethanol-hydrocarbon blends by Vis-NIR spectroscopy
This Application Note shows that visible near-infrared spectroscopy (Vis-NIRS) can determine water content in ethanol-hydrocarbon blends. Vis-NIRS is a fast alternative to conventional lab methods: it accelerates raw material inspection, process monitoring, and final product control.
- AN-U-078Silicate in cooling agents
Scale formation is a critical issue in cooling systems leading to system damage, which generates enormous operational losses. One important component of scale forming is silica. Amorphous silica and metal silicates especially tend to build up scale. Therefore, it is crucial to know the silica concentration in cooling agents. By ion chromatography with UV/VIS detection and PCR, it is possible to determine both free and total silicate content. Sample dilution in ultrapure water and direct injection delivers the free silicate concentration. The total silicate content is determined after hydrolysis of amorphous silica by sample dilution in alkaline eluent, and injection after a reaction time (e.g. 4 hours) prior to the analysis.
- AN-NIR-134Paprika powder analysis with NIR spectroscopy
This study shows how NIR spectroscopy simultaneously measures capsaicin content, Scoville Heat Units, water activity, ASTA color, and ash content in paprika powder samples.
- AB-121Determination of nitrate with the ion-selective electrode
It has been known for years that consuming too much nitrates from foodstuffs can result in cyanosis, particularly for small children and susceptible adults. According to the WHO standard, the hazard level lies at a mass concentration c(NO3-) ≥ 50 mg/L. However, more recent studies have shown that when nitrate concentrations in the human body are too high, they can (via nitrite) result in the formation of carcinogenic and even more hazardous nitrosamines.Known photometric methods for the determination of the nitrate anion are time-consuming and prone to a wide range of interferences. With nitrate analysis continually increasing in importance, the demand for a selective, rapid, and relatively accurate method has also increased. Such a method is described in this Application Bulletin. The Appendix contains a cselection of application examples where nitrate concentrations have been determined in water samples, soil extracts, fertilizers, vegetables, and beverages.
- AN-NIR-079Moisture analysis in fertilizer products
Moisture content is one of the most commonly measured properties of fertilizers. Globally, regulations for different fertilizers vary, but local legal limits ensure that the maximum amount of water must not be exceeded. Next to gravimetric methods, Karl Fischer titration is often used for accurate moisture determination.Compared to these methods, near-infrared spectroscopy (NIRS) offers unique advantages: it generates reliable results within seconds, and at the same time does not create chemical waste. This Application Note explains how NIRS can offer fast, reagent-free analysis of moisture content in various fertilizer products.
- AB-069Titrimetric methods for the chemical analysis of pasta
The quality of egg-based pasta is primarily determined by its egg content. Also of importance, however, is the water content, which influences the storage life of the product, as well as the degree of acidity which, in the case of high values, indicates undesirable acidification during processing or drying. A check of the chloride content shows whether salt has been added to the pasta.
- AN-NIR-036Moisture content and pH value in crude tall oil (CTO)
This Application Note shows the fast and parallel determination of water content and pH value in crude tall oil samples using near-infrared spectroscopy (NIRS). Crude tall oil is an important byproduct of pulp production in the power process. NIRS is an efficient alternative to conventional laboratory methods: It permits rapid raw material inspection, process monitoring and final product checking.
- AN-NIR-143Semola and semolina quality control using NIR spectroscopy
This Application Note demonstrates the use of NIR spectroscopy for the rapid, simultaneous determination of key quality parameters in semola and semolina flours, including protein, moisture, ash content, gluten, and water absorption. Compared with conventional reference methods, NIRS provides a faster, simpler, and highly accurate alternative with excellent precision, enabling efficient quality control and consistent production of high-quality pasta products.
- AN-NIR-016Near-infrared spectroscopy for monitoring a single-pot granulator
This Application Note describes the utilization possibilities of a new sensor design that permits, in combination with an NIRS XDS Process Analyzer, the determination of solvent residues in a High-Shear Granulator during the drying phase. This system configuration reduces the scattering of the density distribution of the powder samples so that it is possible, directly in the process, to model the water and solvent content precisely.
- WP-061Moisture in petroleum products according to ASTM D6304
Knowledge of the water content in lubricating oils, additives, and similar products is important in the manufacturing, purchase, sale, or transfer of petroleum products to help estimate their quality and performance characteristics. Monitoring the water content in such products can prevent damage to infrastructure and ensure safe operation by avoiding corrosion processes and subsequent engine wear. This White Paper explains the easy determination of moisture in petroleum samples by coulometric Karl Fischer titration according to the three procedures outlined in ASTM Method D6304. A comparison is given between the procedures to determine which is most suitable for different sample types.
- AN-T-227Determination of sodium lactate
Sodium lactate is a salt form of lactic acid used in many regulated industries—therefore an accurate determination of the lactate content is required and is already covered in several norms. One such monograph by the US Pharmacopoeia (USP) results in high accuracies and well-defined titration curves but uses titrants and solvents that are more costly than necessary. In comparison, the presented modified method from Metrohm requires a 1:1 mixture of water and acetone and uses aqueous hydrochloric acid as titrant, resulting in an estimated cost reduction of 40% per titration compared to the USP method (USP–NF 2021, Issue 2). Furthermore, the time needed for each analysis is reduced to just 12% of the USP method (excluding blank determination). This Application Note presents both methods to determine lactate content and shows the results obtained on an OMNIS system.
- WP-071Improving the corn to ethanol fermentation process with near-infrared spectroscopy (NIRS)
The fermentation of corn starch to produce ethanol is a complex biochemical process that requires monitoring of many different parameters (e.g., solids, pH, sugar profile, glycerol, lactic and acetic acid, and water and ethanol content). Traditional laboratory analysis using primary methods (e.g. Karl Fischer titration) takes about an hour to complete and is a limiting step for increasing plant capacity and efficiency. As a fast and non-destructive analytical technique, near-infrared spectroscopy (NIRS) can replace routine laboratory analysis, decreasing operating costs and increasing plant efficiency and capacity. This White Paper describes the capabilities of the modern analytical method near-infrared (NIR) spectroscopy for monitoring and improving the fermentation process of corn to ethanol.
- AN-V-072NTA and EDTA in wastewater
NTA and EDTA can be determined as their bismuth complexes at the DME.
- AN-V-110Total chromium in wastewater after UV digestion (polarography method with ethylene diamine)
Cr(VI) is determined by polarography at the SMDE in acetate solution containing ethylene diamine to mask interfering copper ions.Only Cr(VI) is electrochemically active. It is for that reason that all chromium compounds must be present before the analysis as CR(VI), which is guaranteed by UV radiation with a pH > 4.
- AB-141Analysis of edible fats and oils – The seven most important parameters for quality control
As the determination of the exact content of individual glycerides in fats and oils is difficult and time-consuming, several fat sum parameters or fat indices are used for the characterization and quality control of fats and oils. Fats and oils are not only essential for cooking, they are also an important ingredient in pharmaceuticals and personal care products, such as ointments and creams. Consequently, several norms and standards describe the determination of the most important quality control parameters. This Application Bulletin describes eight important analytical methods for the following fat parameters in edible oils and fats:Determination of water content in accordance with the Karl Fischer method; Oxidation stability in accordance with the Rancimat method; Iodine value; Peroxide value; Saponification value; Acid value, free fatty acids (FFA); Hydroxyl number; Traces of nickel using polarography; Special care is taken to avoid chlorinated solvents in these methods. Also, as many of the mentioned methods as possible are automated.
- WP-004Electrochemistry in the environmental sciences
This Metrohm White Paper presents the important role of electrochemistry in the environmental sciences. The applications have to do with basic research for the fuel cell that yields energy from wastewater, the electrical clean-up of contaminated soil and electrochemical CO2 reduction of greenhouse gases for isolating chemical raw materials.
- AN-C-145Ammonium traces besides excess sodium using 940 Professional IC Vario and direct conductivity detection
The determination of low ammonium concentrations besides excess sodium is demanding due to the small retention time difference of these two cations. This Application Note shows direct conductivity detection as an ideal means to detect ammonium in a wastewater sample containing 400 mg/L sodium. AN-S-313 shows the analysis of nitrite traces.
- AN-M-013Chromium speciation by IC-ICP-MS
Differentiation between Cr(III) and Cr(VI) is possible following ISO 24384 guidelines by combining ion chromatography with inductively coupled plasma mass spectrometry.
- AB-119Potentiometric determination of trace bromide and iodide in chlorides
Bromide is removed from the sample as BrCN by distillation. The BrCN is absorbed in sodium hydroxide solution and decomposed with concentrated sulfuric acid, then the released bromide ions are determined by potentiometric titration with silver nitrate solution. Iodide does not interfere with the determination.Iodide is oxidized to iodate by hypobromite. After destruction of the excess hypobromite, the potentiometric titration (of the iodine released from iodate) is carried out with sodium thiosulfate solution. Bromide does not interfere, even in great excess.The described methods allow the determination of bromide and iodide in the presence of a large excess of chloride (e.g., in brine, seawater, sodium chloride, etc.).
- AN-RA-010SERS detection of pesticides using screen-printed electrodes
EC-SERS enhances Raman sensitivity using electrochemically activated gold SPEs, enabling rapid, simplified pesticide detection without complex prep or instrumentation.
- AN-PAN-1056Online monitoring of sodium in industrial power plants
In power plants, corrosion is the greatest enemy. If corrosive impurities are present in the circuit streams (e.g., chlorides and hydroxides), deposition of an insulating layer of scale on the heat transfer surfaces occurs, resulting in costly and critical downtimes. To ensure high throughput of power plants, online analysis of critical parameters such as sodium is highly advantageous for safety, protection, and process optimization. With the 2035 Process Analyzer from Metrohm Process Analytics, operators gain the information they need to accurately identify trends, reduce downtimes, and address operational issues before costly problems arise.
- AB-083Sodium analysis by ion-selective electrode
This document explains how to measure Na ion concentration in diverse matrices with a sodium ion-selective electrode (Na-ISE) using direct measurement and standard addition.
- AN-H-078Determination of total halides in brines
Determination of total halides (Cl- + Br- +I-) in seawater and similar brines. This procedure is suitable for the analysis of total halides in seawater contaminated with sodium aluminate solutions emanating from alumina refineries, and seawater which has been used for the neutralization of alumina refinery waste («red mud») slurries. Given the small concentration of bromine andiodine in seawater, the total halide content approximates the chloride concentration.
- 410000051-BIdentification of microplastics with Raman microscopy
Research laboratories must expand their capabilities to routinely analyze candidate microplastics from environmental samples to determine their origin and help predict biological impacts. Spectroscopic techniques are well suited to polymer identification. Laboratory Raman spectroscopy is an alternative to confocal Raman microscopes and Fourier transform infrared (FTIR) microscopes for quick identification of polymer materials. Raman microscopy was used to identify very small microplastic particles in this Application Note.
- AN-H-077Determination of sodium in brines by aluminum titration
Determination of sodium in seawater and similar brines. This procedure is suitable for the analysis of sodium in seawater contaminated with sodium aluminate solutions emanating from alumina refineries, and seawater which has been used for the neutralization of alumina refinery waste («red mud») slurries.
- TA-023Investigation of MRT contrast media containing gadolinium by means of IC-ICP/MS analysis
This article describes the investigation using ion chromatography and subsequent inductively coupled plasma mass spectronomy (ICP/MS) to determine the extent to which the iron(III) flocculation carried out in the context of wastewater treatment releases toxic gadolinium(III) ions as the result of recomplexing.
- AB-230Potentiometric determination of nonionic surfactants based on polyoxyethylene adducts with the NIO electrode
The titrimetric determination of nonionic surfactants on the basis of polyoxyethylene adducts (POE adducts) is described in the Bulletin. The basis for the determination is the transfer of the nonionic surfactant into a pseudo-cation compound and its precipitation titration with sodium tetraphenylborate (Na-TPB). The NIO electrode is used for the indication of the potentiometric titration. This Bulletin describes determinations in raw products, formulations and wastewater and draws attention to special features, possibilities, limits and disruptions.
- AN-S-349High-low calibration technique: large calibration range with intelligent Partial Loop Injection Technique
In ion chromatography with suppressed conductivity detection, calibration curves quite often are not really linear. Especially, if a calibration has to cover a large concentration range, results will be more accurate when multiple calibration curves for different concentration ranges are applied. The MagIC Net software allows to apply multiple calibration curves within one single determination. This means that for every ion the optimal calibration is applied, improving the accuracy of the results. This method is applied to rainwater samples.
- AN-C-195Cation quantification with increased performance using microbore IC
Microbore ion chromatography offers better sensitivity, shorter retention times, and consumes less eluent, increasing sample throughput and reducing running costs.
- AN-PAN-1029Monitoring peracetic acid (PAA) in a beverage bottling facility
Precise online monitoring of peracetic acid (PPA) for beverage bottling requires a reliable stainless steel process analyzer.
- AN-PAN-1042Online trace analysis of anions in the primary circuit of nuclear power plants
Measures to monitor or prevent corrosion are crucial in nuclear power plants, where significant risks to health and safety can occur if corrosion is left unchecked. Anions corrode metals under high temperature and pressure, therefore their concentrations must be monitored at all times. The analytical challenge in the primary circuit is detection of anions in the μg/L range alongside gram quantities of boric acid and lithium hydroxide. Precise, reliable trace analysis requires the method to be automated as much as possible. The 2060 IC Process Analyzer from Metrohm Process Analytics can measure several anions from a single injection, with combined Inline Preconcentration and Inline Matrix Elimination to measure low anion concentrations precisely and reliably time after time.
- AN-P-079Easily extractable carbohydrates in Italian pasta applying pulsed amperometric detection
Cooked Italian pasta consists of about 30% carbohydrates, mainly starch. Sugars are water soluble and therefore most of them are extracted into the cooking water. This application identifies and quantifies the extractable sugars after water extraction of pasta at 60 °C.
- AN-SENS-001Quantification of paracetamol with square wave voltammetry
This Application Note demonstrates square wave voltammetry for sensitive, reproducible quantification of paracetamol using a screen-printed electrode and INTELLO.
- AN-EC-034Ion-selective electrodes based on screen-printed technology
Advances in polymeric membranes and screen-printed technologies have enabled miniaturized, portable potentiometric sensors ideal for point-of-care analysis.
- AN-EC-043Studying PEDOT:PSS coatings with EQCM-D and Raman spectroscopy
PEDOT:PSS is a tunable, conductive coating whose properties depend on parameters such as counter-ion selection, secondary doping, and polymerization conditions. This Application Note demonstrates the combined use of EQCM-D, Raman spectroscopy, and electrochemical methods to monitor film growth, correlating frequency and dissipation changes across harmonics with in situ spectroscopic and electrochemical signals. The introduced probe-based EQCM-D platform enables simultaneous Raman acquisition, providing a powerful tool to design and optimize PEDOT:PSS coatings.
- AN-COR-019Determining the corrosion rate with INTELLO
Tafel analysis is an important electrochemical technique used to understand reaction kinetics. By studying the Tafel slope, it reveals the rate-determining steps in electrode reactions, aiding fields like corrosion and fuel cell research. This method helps industries optimize processes and improve device performance by tailoring materials and conditions for greater efficiency.
- AN-PAN-1002Online monitoring of cyanide and gold in gold leaching solution
Gold leaching by cyanidation requires precise monitoring of cyanide and gold. Online process analyzers perform such measurements, improving safety and compliance.
- AN-EC-041Studying nickel deposition with EQCM-D and EC-Raman
This application note demonstrates EQCM D for simultaneous mass and dissipation analysis of Ni(OH)₂ electrodeposition.
- AN-PAN-1031Effectively monitoring hydrogen peroxide online in salmon farms
Salmon farms are becoming ever more popular. Strong population growth increases the demand for salmon which has an effect on their cultivation. Ever more fish live in limited space in open net cages. Parasites such as salmon lice can multiply quickly due to the high density of fish. One possibility of fighting the lice is to use baths with weak concentrations of H2O2. The salmon are treated in these concentrations for up to 20 minutes until the lice fall away and die. While it is true that hydrogen peroxide decomposes relatively quickly, it is nonetheless deadly for salmon in higher concentrations. The concentration must therefore always lie within the specifications during treatment. Our process analyzer requires less than two minutes per titration. This means that it permits more concentration determinations per treatment and always guarantees the correct dosage.
- AN-PAN-1003Online analysis of amines concentration in carbon capture plants
Carbon capture systems strip carbon dioxide from flue gases. Online analysis of amines and carbon dioxide enhances amine usage efficiency and reduces operational costs.
- AN-T-103Fully automated determination of aluminum in aqueous solution
In many countries, the aluminum concentration in water is limited to 0.2 mg/L. This application note shows how the analysis of aluminum in water can be done fully automatically by complexometric titration with EDTA.
- AN-PAN-1060Inline process monitoring of moisture content in tetrahydrofuran
This Process Application Note presents a method to accurately monitor low levels of moisture in tetrahydrofuran (THF) in «real-time» safely, reliably, and optimally with a 2060 The NIR Analyzer from Metrohm Process Analytics. Due to the hazardous and hygroscopic nature of THF, a single explosion-proof inline process analyzer is the preferred solution for industries to reduce chemical treatment, improve product quality, and increase profits.
- AN-S-368STREAM – the perfect way of MSM rinsing – even with iron and aluminum in the matrix
The STREAM (suppressor treatment reusing eluent after measurement) is applied since quite some time. The suppressor rinsing with suppressed eluent is advantageous over ultrapure water rinsing: a smaller water dip, faster MSM equilibration, and the avoidance of an additional water supply are just a few. Injecting samples containing iron in the matrix under sulfuric acid regeneration yields reduced peak areas and broader peaks for phosphate. Switching to a regenerant based on sulfuric and oxalic acid allows full regeneration of the MSM. The overlay above shows three subsequently taken chromatograms after more than 300 injections of 10 mg/L iron(II) onto one single MSM chamber. No difference in peak shape or peak area is observed.
- WP-046Overcoming the aqueous limitation at NIR Spectroelectrochemistry
NIR spectroscopy has been traditionally limited due to the water absorption in this spectral range. In this way, the well-known water restriction has limited the development of new applications for NIR spectroelectrochemistry. In this work, several interesting alternatives are proposed in order to minimize or even to remove the aqueous contribution in this spectral range.
- AN-PAN-1051Inline process monitoring of the moisture content in propylene oxide
This Process Application Note presents a method to closely monitor low levels of moisture in propylene oxide safely and reliably by using a single explosion-proof inline process analyzer.
- AN-T-203Acidity in volatile solvents and chemical intermediates
The presence of acidic components in volatile solvents could be a result of contamination, decomposition during storage, distribution or manufacture. An increased acid content in solvents could lead to a variety of problems like shorter storage stability or chemical corrosion. Using the Optrode for indication, the acidity is determined by photometric titration with sodium hydroxide as titrant and phenolphthalein as indicator. If the volatile solvent is water soluble, it is dissolved in deionized water, if not, it is dissolved in carbon-dioxide free ethanol.
- AN-T-201pH value of engine coolants or antirust
Corrosion of metallic components is an inherent problem for engines, because metals naturally tend to oxidize in the presence of water and/or acids. Increased acid content is indicated by a low pH value, and could lead to a variety of problems like a shorter storage life (stability) or a reduced buffer capacity of the used engine coolant or antirust.In this Application Note, engine coolants or antirust samples are dissolved in water, and the pH measurement using the Profitrode is carried out according to ASTM D1287.
- AN-NIR-078Automated moisture analysis in pharmaceutical peptides
The quantification of residual moisture in lyophilized pharmaceutical peptides is an important measure for quality control in the pharmaceutical industry. For development purposes, such measurements are necessary and routinely performed during stability studies and to optimize the freeze-drying process (lyophilization). Currently, Karl Fischer titration is widely used for moisture determination in routine analysis. However, this method is time consuming and destroys the sample during analysis. This Application Note shows that near-infrared spectroscopy (NIRS) is a fast, reagentless, non-destructive method to determine moisture content in lyophilized pharmaceutical products.
- AN-K-07234433 HYDRANAL™ NEXTGEN Coulomat AG-FI
Karl Fischer reagents contain buffer substances (usually imidazole) since the reaction constant is dependent on the pH value. A constant pH therefore ensures the most repeatable results. In 2015, imidazole was classified by European Union the as a CMR (carcinogenic, mutagenic or toxic) substance and the statement H360D was added, stating possible harm to fertility or a fetus. Meanwhile, other reagents free of imidazole are available for purchase. This Application Note summarizes test measurements with 34433 HYDRANAL™ NEXTGEN Coulomat AG-FI.
- AN-NIR-064Quality control of ammonium nitrate
Specialty chemicals have to fulfill multiple quality requirements. One of these quality parameters, which can be found in almost all certificates of analysis and specifications, is the moisture content. The standard method for the determination of moisture content is Karl Fischer titration.This method requires reproducible sample preparation, chemicals, and waste disposal. Alternatively, near-infrared spectroscopy (NIR) can be used for the determination of moisture content. With this technique, samples can be analyzed without any preparation and without using any chemicals.
- AN-S-391Anions in diesel applying advanced Inline Matrix Elimination
Anions in diesel, especially biodiesel, may cause harmful deposits in the engine. Determination with ion chromatography requires the transfer of the diesel anions into an aqueous solution, injectable to the IC. A typical method to transfer the anions into water is via Inline Extraction with subsequent Inline Dialysis prior to the injection (see AN-C-101 for a respective analysis of cations). In the actual Matrix Elimination method, diesel diluted with isopropanol is injected into an isopropanol stream and passed through a preconcentration column. Isopropanol washes off the diesel, and a subsequent rinsing step with ultrapure water removes excess isopropanol.
- AN-I-031Dissolved oxygen in acrylic dispersion paint
Acrylic dispersion paints are made of pigment suspended in acrylic polymer emulsions, which also include other organic material such as plasticizers, defoamers, or stabilizers. Acrylic dispersion paints are water-soluble but become resistant to water when dry. Due to the fact that once dry, acrylic dispersion paints can no longer be used, they should be stored air-tight at room temperature. For research purposes, it is of interest to assess the dissolved oxygen (DO) concentration in such samples as it is assumed that the DO amount can be related to the storage life. This Application Note describes a fast and accurate determination of dissolved oxygen by using an optical sensor.
- AN-T-221SET titration of HPLC mobile phases
This Application Note shows the automatic pH adjustment of a mixture of acetonitrile, water and amine using a Metrohm titrator.
- AN-PAN-1050Inline moisture analysis in fluid bed dryers by near-infrared spectroscopy
In the pharmaceutical industry, the fluid bed granulator/dryer is an integral point in the manufacture of powdered materials. Residual moisture must be kept within certain specifications to avoid fracturing of particles or caking (stickiness) of the bulk material. Current methods are slow and cumbersome, which can lead to damaged or degraded product. The ability to monitor the residual moisture content inline after drying is possible with near-infrared spectroscopy (NIRS). The 2060 The NIR Analyzer offers fast, reagent-free, nondestructive analysis of residual moisture of powders with a fluid bed probe specifically designed for these applications.
- AN-T-196Assay of Vitamin C
Vitamin C, also known as ascorbic acid or L-ascorbic acid, is an essential nutrient involved in the repair of tissues and the enzymatic production of certain neurotransmitters. It is required for the functioning of several enzymes and immune performance, and is also an important antioxidant. This nutrient is found in many foods and is often used as a dietary supplement.USP general chapter <580> describes a titration technique to determine the assay of Vitamin C as ascorbic acid, sodium ascorbate, and calcium ascorbate dehydrate, or their mixture in finished dosage forms as capsules, tablets, and oral suspensions. This Application Note demonstrates the Vitamin C determination in water-soluble vitamin tablets. The methodology can also be applied for oil-soluble vitamin or mineral tablets, as well as oil- and water-soluble vitamin or mineral capsules.
- AN-NIR-151Moisture and protein content in corn starch with NIR spectroscopy
Corn starch serves as a gelling and thickening agent in the confectionary industry. It is also an ideal reusable molding and drying medium for starch-molded candies, where its moisture content is critical to monitor. Near-infrared spectroscopy (NIRS) provides a rapid, reagent-free method to determine moisture and protein content in corn starch. The technique is straightforward to operate and suitable for atline monitoring or routine quality control laboratories.
- AN-T-233Determination of pyrophosphates by titration
Titration is an accurate and precise method that can be used to determine the pyrophosphate content in aqueous products. The OMNIS Titrator equipped with a dUnitrode delivers reliable determinations.
- AN-NIR-148Fish meal analysis by near-infrared spectroscopy
Fish meal is a nutrient-rich feed ingredient requiring analysis of parameters such as protein, fat, fiber, moisture, and ash content. This Application Note demonstrates the feasibility of using near-infrared spectroscopy (NIRS) for rapid multiparameter fish meal analysis without chemical reagents. NIRS delivers results within seconds, reducing costs, improving laboratory safety, and increasing sample throughput compared with conventional wet-chemistry methods which can take hours to perform.
- AN-S-395Forensic examination analysis with IC
Forensic institutes examine terrorist attacks and warfare agents via trace detection analysis of the used explosives and their residuals. Of particular importance is the acquisition of «chemical fingerprints» for criminal investigation departments and governmental security agencies. Institutes for public health and environmental protection analyze such compounds that can contaminate the underlying soil and infiltrate ground water.Forensic investigation with ion chromatography (IC) using suppressed conductivity detection allows a sensitive and robust determination of anionic contaminants such as chlorate, thiosulfate, thiocyanate, and perchlorate next to the common inorganic anions over a broad concentration range.
- AN-NIR-115Multiparameter quality control of palm oil with NIR spectroscopy
Near-infrared spectroscopy (NIRS) quickly assesses key quality parameters in palm oil such as iodine value and fatty acid profile without sample preparation.
- AN-PAN-1035Online analysis of indigo, hydrosulfite, and other parameters in textile dye baths
The size of the indigo molecule makes it difficult to dye synthetic fibers, but the large pores of cellulose (such as in cotton) accept it readily. Indigo is insoluble in water, so it must first be reduced to the water-soluble leuco-indigo form by sodium hydrosulfite in a strong alkaline bath. Good circulation within the bath is imperative for consistent dye coverage, but care must be taken not to introduce any oxygen. Fabrics must be oxidized between dips in the dye bath in order to set the indigo within the pores of the fibers, but multiple dips are necessary for darker, uniform coverage. Many parameters need to be monitored and controlled to ensure high quality of the end product: the pH value for proper NaOH (alkali) dosage, the concentrations of both hydrosulfite and indigo, as well as the temperature of the bath and even the redox potential.
- AB-101Complexometric titrations with the copper-selective electrode
This document outlines complexometric and potentiometric determination of metal ions via EDTA titration using a copper-selective electrode (Cu-ISE) with a durable epoxy shaft and crystal membrane. Because the electrode is insensitive to complexing agents, a preformed Cu–metal complex must be introduced into the sample prior to analysis. The method, applicable to direct or back-titration, exploits EDTA–metal formation constants to define equivalence points and enables quantification in several different matrices.
- AN-T-135Chloride in cheese – Automation reduces sample preparation and increases throughput
The WHO recommends a maximum daily intake of 5 g salt for an adult. The chloride content in food correlates with the salt content, its determination is therefore described by various standards. In cheese and cheese products with a chloride content higher than 0.2%, chloride is usually determined by a precipitation titration with silver nitrate. However, time-consuming sample preparation is required, as the cheese has to be homogenized and the chloride extracted with hot water.This Application Note describes the fully automatic determination of chloride in cheese according to EN ISO 5943, ISO 21422, IDF 242 and IDF 88 including sample preparation with a Polytron homogenizer. This increases productivity due to a higher sample throughput and lower work load for the operator.
- AN-S-254MISP – Metrohm Inline-Ultrafiltration – Cross Contamination < 0.1%
Determination of the cross contamination of 100 mg/L of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate to ultrapure water using anion chromatography with conductivity detection after chemical suppression and inline ultrafiltration.
- AN-NIR-035Quality control of polyols with NIRS
Polyols are widely used as polyurethane feedstocks, where tight quality control of parameters such as hydroxyl value, acid number, moisture, and viscosity is essential. Conventional titration methods are standardized but slow and costly due to hazardous chemicals and waste handling. Near-infrared spectroscopy (NIRS), recognized by ASTM for hydroxyl value determination, enables rapid, reagent-free, multiparameter analysis of polyols with significantly lower operating costs.
- AN-COR-016ASTM G61: Standard test method for conducting cyclic potentiodynamic polarization
This Application Note details ASTM G61-compliant corrosion measurements performed with VIONIC powered by INTELLO using Metrohm’s ASTM-compliant corrosion cells.
- 8.000.6052Quality assurance of biofuels
This poster provides an overview of ion chromatographic methods combined with inline sample preparation for the determination of anions and water-extractable cations in biofuels. In addition, the determination of the oxidation stability is described.
- AN-NIR-117Analysis of moisture, ash, carbon, and volatile content in coal by NIRS
Conventional methods used to analyze moisture, ash, fixed carbon, and volatile content in coal samples, are time consuming and costly. Near-infrared (NIR) spectroscopy is excellently suited to determine all parameters simultaneously in less than one minute without any sample preparation.
- AN-PAN-1053Monitoring of DOTP production via esterification with inline analysis
This Process Application Note presents a way to closely monitor multiple parameters simultaneously during the dioctyl terephthalate production process with near-infrared spectroscopy.
- WP-014High productivity and profitability in IC environmental analysis
Brad Meadows is Vice President and Lab Director at the US company BSK Labs, which runs a number of environmental laboratories and service centers. Brad is an analytical chemist and has been working in the management of analysis laboratories for 15 years. He shared his experiences with Metrohm ion chromatography with us in the form of some concrete facts and figures.
- AN-RS-005Differentiation of inorganic salts using Raman spectroscopy
This Application Note documents the suitability of hand-held Raman spectrometers, e.g., the Mira M-1, for the identification and differentiation of salts such as carbonates, phosphates, and sulfates. The focus of the work was the rating of the influence of the cationic part and of the crystal water on the Raman spectroscopy identification of the salts.
- AN-T-169Determination of citrate in detergents in accordance with ASTM D4608
Citrate is used in detergents as a water softener for the prevention of lime deposits. The citrate or citric acid content is therefore an important parameter for the quality control of detergents that can be determined conveniently and precisely using titration with copper sulfate.
- 8.000.6011Ion chromatographic determination of anions, cations and organic acids in biofuels
Quality and process control of biofuels require straightforward, fast and accurate analysis methods. Ion chromatography (IC) is at the leading edge of this effort. Traces of anions in a gasoline/ethanol blend can accurately be determined in the sub-ppb range after Metrohm Inline Matrix Elimination using anion chromatography with conductivity detection after sequential suppression. While the analyte anions are retained on the preconcentration column, the interfering organic gasoline/bioethanol matrix is washed away.Detrimental alkali metals and water-extractable alkaline earth metals in biodiesel are determined in the sub-ppm range using cation chromatography with direct conductivity detection applying automated extraction with nitric acid and subsequent Metrohm Inline Dialysis. Unlike high-molecular substances, ions in the high-ionic strength matrix diffuse through a membrane into the low-ionic water acceptor solution. In biogas reactor samples, low-molecular-weight organic acids stem from the biodegradation of organic matter. Their profile allows important conclusions concerning conversion in the anaerobic digestion reaction. Volatile fatty acids and lactate can be accurately determined by using ion-exclusion chromatography with suppressed conductivity detection after inline dialysis or filtration.
- AN-T-168EDTA in liquid hand soap in accordance with ASTM D1767
Complexing agents such as EDTA are used in soaps and other detergents in order to remove unwanted metal ions and to lower water hardness. The EDTA content in soaps and detergents can be determined using potentiometric titration with copper sulfate as titrant and the Cu-ISE as electrode.
- AN-N-058LOD and LOQ for silicate and borate determination according to EPA (MDL procedure)
Determination of silicate and borate and their limits of determination (LOD) and quantification (LOQ) according to the EPA procedure for method detection limit (MDL) using anion chromatography with direct conductivity detection and Metrohm Inline Calibration.
- 8.000.6014Determination of anions and cations in aerosols by ion chromatography
The study of adverse effects of air pollution requires semi-continuous, rapid and accurate measurements of inorganic species in aerosols and their gas phase components in ambient air. The most promising instruments, often referred to as steam collecting devices, are the Particle-Into-Liquid-Sampler (PILS) coupled to wet-chemical analyzers such as a cation and/or anion chromatograph (IC) and the Monitoring instrument for AeRosols and GAses (MARGA) with two integrated ICs. Both instruments comprise gas denuders, a condensation particle growth sampler as well as pump and control devices. While PILS uses two consecutive fixed denuders and a downstream growth chamber, the MARGA system is composed of a Wet Rotating Denuder (WRD) and a Steam-Jet Aerosol Collector (SJAC). Although the aerosol samplers of PILS and MARGA use different assemblies, both apply the technique of growing aerosol particles into droplets in a supersaturated water vapor environment. Previously mixed with carrier water, the collected droplets are continuously fed into sample loops or preconcentration columns for on-line IC analysis. While PILS has been designed to sample aerosols only, MARGA additionally determines water-soluble gases. Compared to the classical denuders, which remove gases from the air sample upstream of the growth chamber, MARGA collects the gaseous species in a WRD for on-line analysis. In contrast to the gases, aerosols have low diffusion speeds and thus neither dissolve in the PILS denuders nor in the WRD. Proper selection of the ion chromatographic conditions of PILS-IC allows a precise determination, within 4 to 5 minutes, of seven major inorganic species (Na+, K+, Ca2+, Mg2+, Cl-, NO3- and SO4 2-) in fine aerosol particles. With longer analysis times (10-15 minutes) even airborne low-molecular-weight organic acids, such as acetate, formate and oxalate can be analyzed. MARGA additionally facilitates the simultaneous determination of HCl, HNO3, HNO2, SO2 and NH3.PILS and MARGA provide semi-continuous, long-term stand-alone measurements (1 week) and can measure particulate pollutants in the ng/m3 range.
- 8.000.6005Hyphenated techniques as modern detection systems in ion chromatography
The coupling of highly efficient ion chromatography (IC) to multi-dimensional detectors such as a mass spectrometer (MS) or an inductively coupled plasma mass spectrometer (ICP/MS) significantly increases sensitivity while simultaneously reducing possible matrix interference to the absolute minimum. By means of IC/MS several oxyhalides such as bromate and perchlorate can be detected in the sub-ppb range. Additionally, organic acids can be precisely quantified through mass-based determination even in the presence of high salt matrices. By means of IC-ICP/MS different valence states of the potentially hazardous chromium, arsenic and selenium in the form of inorganic and organic species can be sensitively and unambiguously identified in one single run.
- AN-P-057Polydextrose in cookies using pulsed amperometric detection in accordance with AOAC 2000.11
Polydextrose is a low-calorie, synthetic polymer made of glucose. It is a recognized additive for foodstuffs. Hot water is used to extract the polydextrose from the foodstuff, after which it is centrifuged. Subsequent fermentation removes maltooligomers and fructans. Afterwards, the polydextrose is quantified using anion-exchange chromatography with pulsed amperometric detection.
- AN-CIC-030Fluorine determination from fluorochemicals in fabrics applying Combustion IC
In textiles, the water-repelling effect may be introduced by different treatments, such as the application of fluorochemicals. These compounds, especially perfluoroorganic substances, are extremely persistent in the environment and are therefore listed as emergent contaminants. Combustion IC with pyrohydrolysis and subsequent ion chromatographic determination is applied to analyze the fluorine content in fabrics.
- WP-062Overcoming difficulties in ion measurement: Tips for standard addition and direct measurement
Ion measurement can be conducted in several different ways, e.g., ion chromatography (IC), inductively coupled plasma optical emission spectrometry (ICP-OES), or atom absorption spectroscopy (AAS). Each of these are well-established, widely used methods in analytical laboratories. However, the initial costs are relatively high. In contrast, ion measurement by the use of an ion-selective electrode (ISE) is a promising alternative to these costly techniques. This White Paper explains the challenges which may be encountered when applying standard addition or direct measurement, and how to overcome them in order for analysts to gain more confidence with this type of analysis.
- 8.000.6103Speciation of Cr(III) and Cr(VI) by IC-ICP-MS and Empower 3
This poster demonstrates the feasibility of coupling a Metrohm IC system to a PerkinElmer NexION ICP-MS, operated under Empower 3 Software.Using a Metrosep Carb 2 column, the chromatographic separation of both species was achieved with a high resolution. Low background and high sensitivity allow determination in the low ng/L range.Optimal separation and full complexation of Cr(III) is already possible with EDTA concentrations from 40 μmol/L in low matrix solutions and may need to be increased depending on the sample matrix.Handling of the system was easy and user friendly. It was shown that speciation of Cr(III) and Cr(VI) can be carried out on this system utilizing a professional data system for acquisition, processing, and reporting.
- AN-O-045Organic acids in monoethylene glycol by ion-exclusion chromatography with inverse suppression
Monoethylene glycol (MEG) is used to remove water from natural gas before further processing. Due to high temperatures applied, glycol degradation to glycolic, formic, and acetic acid may occur. These reactions are unwanted as the emerging acids are corrosive. The determination of the organic acids is achieved by ion-exclusion chromatography with conductivity detection after inverse suppression.
- AN-T-141Automatic photometric determination of manganese using the Optrode
Manganese is determined as Mn(II) in aqueous solutions at pH 10 with Eriochrome Black T as indicator. Ascorbic acid is added to ensure that manganese is present in its bivalent form. The precipitation of water-insoluble manganese hydroxide is prevented by adding triethanolamine (TEA). The Optrode is used for detection at a wavelength of 610 nm.
- AN-CIC-011Analysis of an ion exchanger using Metrohm Combustion IC
The manufacture of ultrapure water for the pharmaceuticals industry or the semiconductor industry requires high-quality ion exchangers. Metrohm Combustion Ion Chromatography is an indispensable tool in this connection for testing the purity of anion exchange material. The output sample was wet and had to be dried at 105 °C in a special oven with waste air evacuation.Keyword: pyrohydrolysis
- AN-I-023Fluoride in tea
One of the major sources of fluoride intake for humans comes from foodstuff, such as tea. Tea actually has one of the highest potentials to increase the daily fluoride intake. Excessive fluoride intake may lead to dental or skeletal fluorosis. The World Health Organization does not recommend consuming water with a fluoride content higher than 1.5 mg/L. In the presented method according to DIN 10807, the fluoride content can be assessed quickly with an ion selective electrode.
- 8.000.6074Influence of pH, temperature, and molybdate concentration on the performance of the triiodide method for the trace-level determination of bromate (EPA 326)
This poster discusses results showing the influence of pH, temperature of the post-column reactor, eluent composition, and iodide concentration on the sensitivity of the triiodide method.
- AN-T-170Nitrilotriacetate (NTA) in detergents in accordance with ASTM D4954
Nitrilotriacetate (NTA) is a complexing agent that is used in detergents as a water softener. NTA forms complexes with metal ions such as Ca2+, Cu2+ and Fe3+ and thus prevents the formation of lime and its deposits. The NTA content is therefore an important parameter for the quality of detergents and is determined using back titration of an excess of copper nitrate.
- AN-V-124Iron(III) traces in standard solution with solochrome violet RS
The concentration of Fe(III) is determined by adsorptive stripping voltammetry with solochrome violet RS as complexing agent. All reagents have to be added in the order as listed below. Fe(II) does not show any signal. All reagents typically contain iron impurities. Therefore a subtraction of the reagent blank is recommended.
- AN-CIC-024Organic chloride in naphtha fraction of crude oil distillation according to ASTM D8150
The content of organic chloride in crude oil is determined according to ASTM D8150 in the naphtha fraction after distillation. The naphtha fraction is washed with caustic and water, respectively, to remove hydrogen sulfide and inorganic halides. Here, the determination of organic chloride after inline combustion is presented. Although the sulfur content was of no interest in this application, the same setup allows sulfur quantification.
- AN-S-393Anions in hydrogen peroxide and ammonium hydroxide
The semiconductor industry requires high-purity or even ultrahigh-purity chemicals for the production of electronic components. The purity of the chemicals is crucial for the quality and efficient production of the parts. Here, hydrogen peroxide and ammonium hydroxide are analyzed applying traditional sample preparation methods like digestion and evaporation with subsequent reconstitution with ultrapure water. The received samples are injected applying intelligent Preconcentration Technique (MiPCT).
- AN-T-217Hypochlorite and sodium chloride in disinfectant
Sodium hypochlorite and sodium chloride can be effectively use as disinfectant for water and surfaces. The World Health Organization (WHO) recommends, depending on the application, concentrations in disinfectants of 1000 mg/L to 5000 mg/L NaOCl and up to 200 g/L NaCl.This Application Note demonstrates a reliable method to determine the hypochlorite and sodium chloride content in disinfectants by two subsequent argentometric titrations in the range recommended by the WHO.
- AN-H-034Determination of calcium and magnesium in process samples
Determination of calcium and magnesium in process solutions.
- AN-N-045Chromate using post-column reaction
Determination of chromate using anion chromatography with post-column reaction and UV/VIS detection.
- AN-N-027Traces of bromide and iodide using amperometric detection
Determination of traces of bromide and iodide using anion chromatography with amperometric detection at the silver electrode.
- TA-020IC-MS and IC-ICP/MS analysis in the environment
This article describes the coupling of ion chromatography with mass spectrometry (IC-MS) and plasma mass spectrometry (IC-ICP/MS) for the trace analysis of potentially hazardous compounds in the environment.
- AN-H-020Determination of chromium in leather waste solutions
Determination of chromium in leather waste solutions in the range between 1000 and 30,000 ppm.
- AN-N-065Borate in borate effluent
Determination of borate in a borate effluent using anion chromatography with direct conductivity detection.
- AB-226Determination of arsenic by stripping voltammetry at the rotating gold electrode
This Bulletin describes the determination of arsenic by anodic stripping voltammetry (ASV) at the rotating gold electrode. A determination limit of 0.5 μg/L can be achieved with 10 mL sample solution. A differentiation between the As(III) concentration and the total arsenic concentration can be made by appropriate selection of the deposition potential. The analyses are performed with a special gold electrode whose active surface is located laterally; c(HCl) = 5 mol/L is used as supporting electrolyte. For the determination of the total arsenic content, As(III) and As(V) are reduced at -1200 mV by nascent hydrogen to As0, which is preconcentrated on the electrode surface. If the deposition is carried out at -200 mV then only As(III) is reduced; this allows the differentiation between total arsenic and As(III). During the subsequent voltammetric determination the preconcentrated As0 is again oxidized to As(III).
- AB-110Determination of free cyanide by polarography
This Application Bulletin describes a polarographic method for the determination of cyanide that allows to determine free cyanide fast and accurately. The determination also succeeds in solutions containing sulfides, where other methods fail. Cyanide concentrations in the range b(CN–) = 0.01...10 mg/L cause no problems. Interference caused by anions and complexed cyanides has been investigated.
- AN-PAN-1041Inline monitoring of free isocyanate (%NCO) content in polyurethane
Polyurethanes are a class of synthetic polymers formed by reacting liquid di/polyisocyanates and polyols with a catalyst and various additives in a reactor. Polymer properties are modified with stepwise additions of these chemicals at different points in time depending on whether the process has reached an equilibrium. NCO functional groups from unreacted isocyanates must be quenched at the end for a finished product, and this parameter must be known to determine the proper chemical mixing ratio. A fast, non-destructive real-time measurement of %NCO can be obtained by using NIR spectroscopy with a probe seated directly in the reactor.
- AN-H-065Determination of salts of carboxylic acids by aqueous acidometric titration
Determination of sodium and potassium salts of carboxylic acids in aqueous media. May be used for analysis of reagent purity.
- AN-PAN-1015Calcium and sulfate in flue-gas desulfuration
This Process Application Note deals with the online monitoring of calcium and sulfate in flue gas scrubbing solutions using titration. Other contaminants that can be measured are sulfite, chloride, and chlorine. Low concentrations of heavy metals such as cadmium, zinc, copper, and lead can be measured in the ppb/ppm range with the ADI 2045VA Process Analyzer using voltammetry.
- AN-CIC-005Iodine in a pharmaceutical product using Combustion Ion Chromatography with Inline Matrix Elimination
The iodine content in numerous iodized X-ray contrast media (ICM) is around 50% and is determined with great accuracy using Combustion Ion Chromatography. Large quantities of H2O2 (1,000 mg/L) are required for complete absorption of the iodine. Similarly, the concentration of the internal standard should be 50 mg/L. The water content of the X-ray contrast media is determined by means of Metrohm's Karl Fischer oven method and incorporated in the final calculation.Keyword: pyrohydrolysis
- AN-CS-001Reproducibility of 10 µg/L injections after cation suppression
Cation chromatography with sequential suppression enables the determination of cations in their hydrogen carbonate form. The eluent – usually nitric acid – is converted into carbonic acid. Following its decomposition into carbon dioxide and water, the former is continuously removed by the CO2 suppressor. The reduction of baseline noise thus achieved permits the lowering of the detection limits and improves reproducibility, even at very low cation concentrations. This Note shows the reproducibilities determined for cation concentrations of 10 µg/L.
- AN-CS-017Metrosep C Supp 2 - 250/4.0: Ammonium in acidic absorption solution – proof of concept
Acidic solutions used as scrubber solutions for ammonium typically have a pH of 2 or lower. This pH value is too low for silica based IC columns typically applied in direct conductivity detection of cations. The Metrosep C Supp 2 - 250/4.0 is polymer based and allows injecting low pH samples. An acidified drinking water sample spiked with ammonium is analyzed. The results indicate that such acidic solutions can be analyzed with conductivity detection after sequential cation suppression.
- AN-NIR-155Salt content in pickled vegetables by near-infrared spectroscopy (NIRS)
This study demonstrates that near-infrared spectroscopy (NIRS) provides a fast, reagent-free method for determining salt content in ready-to-eat pickled foods. Salt content is a critical quality and safety parameter in the production of pickled vegetables and must be monitored throughout processing and in the final product. Although NaCl exhibits no characteristic NIR absorption bands, salt-induced changes in water absorbance bands enable its quantification by NIRS.
- AN-T-025Hydrogen peroxide content in aqueous solutions
Peroxides are often used for disinfection and water treatment purposes due to their antiseptic properties. Lower concentrations between 0.3–3% are used in households, while higher concentrations can be used for sterilization purposes. Additionally, peroxides are utilized as oxidizing and bleaching agents. Peroxides, perborates, and percarbonates can easily be determined by titration. This application note presents two titration methods for peroxide analysis: ASTM D2180 for concentrated hydrogen peroxide solutions, and a second method for trace determination of hydrogen peroxide, suitable for concentrations as low as 0.4 mg/L.
- AN-U-073Sulfur speciation in mining leachate by ion chromatography appling a perchlorate eluent and UV/VIS detection
In gold mining, there is a tendency to switch from cyanide leaching to the much less toxic thiosulfate leaching process. Thiosulfate leaching is a sensitive process that requires more optimization of the components of the leach reaction to maximize gold recovery and reagent loss. Sulfite, thiosulfate, thiocyanate, and tetrathionate are separated on a Metrosep A Supp 5 - 250/4.0 column. Perchlorate is choosen as an eluent as most of the metal perchlorates are soluble in water. This avoids metal precipitation in the IC System.
- AB-066Potentiometric and thermometric determination of boric acid
Boric acid is used in many primary circuits of nuclear power plants, in nickel plating baths, and in the production of optical glasses. Furthermore, boron compounds are found in washing powders and fertilizers. This bulletin describes the potentiometric and thermometric determination of boric acid. The determination also covers further boron compounds, when acidic digestion is applied.
- AN-T-004Chloride in meat products
In order to maintain product quality, the sodium chloride content in meat products must be monitored, as the limit values defined by the respective public health authorities must not be exceeded. The chloride content in food correlates with the salt content, its determination is therefore described in various norms and standards. However, preparation of meat samples is time consuming, as it requires homogenization with a mixer and a chloride extraction with water.In order to reduce workload and working hours, this Application Note describes a fully automatic potentiometric titration of chloride with silver nitrate in meat products based on ISO 1841-2, including fully automated sample preparation using a Polytron homogenizer.
- AB-241Determination of cadmium and lead by anodic stripping voltammetry at a mercury film electrode
This Application Bulletin describes the determination of cadmium and lead at a mercury film electrode (MFE) by anodic stripping voltammetry (ASV). The mercury film is plated ex situ on a glassy carbon electrode and can be used for up to one day. With a deposition time of 30 s, the limit of detection is ß(Cd2+) = 0.02 µg/L and ß(Pb2+) = 0.05 µg/L. The linear working range for both elements goes up to approx. 50 μg/L using the same deposition time.
- AB-254Determination of zinc, cadmium and lead by anodic stripping voltammetry at a mercury film electrode
This Application Bulletin describes the determination of zinc at a mercury film electrode (MFE). Zinc can also be determined simultaneously with cadmium and lead. The determination of copper at the MFE is not possible. The mercury film is plated ex-situ on a glassy carbon electrode and can be used for half a day up to one day.Zinc can be determined at the mercury film electrode by anodic stripping voltammetry (ASV). The presence of copper, which is naturally present in many samples, affects the determination of zinc due to the formation of an intermetallic compound. As a result the determined concentrations of zinc are too low. The addition of gallium can eliminate the interference to a certain extent since the intermetallic complex of gallium and copper is more stable than the complex of zinc and copper.With a deposition time of 10 s, the limit of detection is β(Zn2+) = 0.15 μg/L. The linear working range goes up to approx. 300 μg/L.With the deposition time of 10 s the method is suitable for samples between 10 μg/L and 150 μg/L Zn content. For samples with lower concentrations the results are more reliable if the deposition time is increased to e.g. 30 s. Samples with higher concentrations have to be diluted.
- AN-T-202Reserve alkalinity of engine coolants
Corrosion of metallic components is an inherent problem for engines, because metals naturally tend to oxidize in the presence of water and/or low pH value. The reserve alkalinity of engine coolants and antirusts is a measure of the buffering ability to absorb acidity. The reserve alkalinity is frequently used for quality control during production and often listed in the specifications of the coolants. A fast and accurate determination is therefore important.This Application Note describes the straightforward determination of reserve alkalinity according to ASTM D1121. Using a fully automated system allows an accurate and reliable determination due to the reduction of human errors. Furthermore, the operator is free to carry out other tasks increasing the efficiency of the laboratory.
- AB-251Polarographic determination of cinchocaine (dibucaine) in pharmaceutical preparations
Cinchocaine (dibucaine) is used in the form of ointments or injection solutions as a local anaesthetic. Its base is soluble in diethyl ether; its hydrochloride, on the other hand, is insoluble in diethyl ether but easily soluble in water. This Bulletin describes the determination of cinchocaine in ointments, creams and injection solutions by means of differential pulse polarography. An acetate buffer pH = 4.8 is used as the supporting electrolyte. The limit of quantitation and the linear working range of the method are given. The necessary sample preparation steps are also dealt with in this Bulletin.
- AN-U-013HEDPA, PBTC, and NTP
Determination of HEDPA, PBTC, and NTP using anion chromatography with UV/VIS detection after post column reaction (PCR).
- AB-036Half wave potentials of metal ions for the determination by polarography
In the following tables, the half-wave potentials or peak potentials of 90 metal ions are listed. The half-wave potentials (listed in volts) are measured at the dropping mercury electrode (DME) at 25 °C unless indicated otherwise.
- AN-N-046Determination of fosetyl-aluminum by non-suppressed ion chromatography
Determination of fosetyl-aluminum (aluminum tris(o-ethylphosphate)) using anion chromatography with direct conductivity detection.
- AB-441Assay of pyrithione complexes – Reliable determination by potentiometric titration
Pyrithione complexes, such as zinc pyrithione (ZnPT), copper pyrithione (CuPT), and sodium pyrithione (NaPT), are used as fungicides and bactericides. ZnPT is used in the treatment of skin conditions such as seborrheic dermatitis or dandruff. Furthermore, ZnPT is sometimes used as an antibacterial agent in paints to prevent algae and mildew growth. CuPT is primarily in use as a biocide to prevent biofouling of surfaces submerged in water. Meanwhile, NaPT is used as antifungal agent for treatment of mycosis, such as athlete’s foot. The different pyrithione complexes are determined by iodometric titration using a maintenance-free Pt Titrode for the indication.
- AB-114Determination of copper, nickel, cobalt, zinc, and iron in a single operation by polarography
Cu2+, Co2+, Ni2+, Zn2+, and Fe2+/Fe3+ are determined simultaneously. Interference due to the presence of other metals is mentioned, and methods given to eliminate it. The threshold of determination is ρ = 20 µg/L for Co and Ni, and ρ = 50 µg/L each for Cu, Zn, and Fe.
- AN-S-280Ten anions in an offshore effluent
Determination of acetate, chloride, nitrite, bromide, nitrate, phosphate, sulfate, oxalate, fumarate, and molybdate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-222Anions in borate effluent
Determination of fluoride, chloride, nitrate, phosphate, and sulfate in a borate effluent using anion chromatography with conductivity detection after chemical suppression.
- AN-C-130Cations in offshore effluent
Determination of lithium, sodium, ammonium, potassium, manganese, calcium, magnesium, strontium, and barium in an offshore effluent using cation chromatography with direct conductivity detection.
- AN-S-340Traces of organic acids in addition to standard anions with the aid of a dose-in gradient
Traces of organic acids can be determined only with difficulty in the presence of high concentrations of standard anions, because their small peaks generally disappear under the larger peaks of the standard anions. A simple dose-in-gradient improves the separation: acetate and formate are baseline-separated from fluoride. Furthermore, oxalate elutes considerably less than sulfate. The separation takes place on a column of the Metrosep A Supp 7 - 250/4.0 type with subsequent conductivity detection following sequential suppression.
- AB-053Determination of ammonium or Kjeldahl nitrogen
The potentiometric titration of Kjeldahl nitrogen is one of the most common analytic procedures. It is referenced in numerous standards, ranging from the food and animal feed industries through sewage and waste analysis and all the way to the fertilizer industry. As a rule, the samples are digested with concentrated sulfuric acid with the addition of a catalyst. The ammonium sulfate that is formed is distilled as ammonia in alkali solution, collected in an absorption solution and titrated there.This Bulletin provides a detailed description of potentiometric nitrogen determination following distillation of the digestion solution, followed by a discussion of the possibilities of coulometric titration (without distillation).
- AB-117Determination of selenium by cathodic stripping voltammetry
In the past, selenium determinations have always been either unreliable or have required complicated methods. However, as selenium is on the one hand an essential trace element (vegetable and animal tissues contain about 10 μg/kg), while on the other hand it is very toxic (threshold value 0.1 mg/m3), it is very important to cover determinations in the micro range. Cathodic stripping voltammetry (CSV) enables selenium to be determined in mass concentrations down to ρ(Se(IV)) = 0.3 μg/L.
- AN-NIR-076Quality control of polyvinyl alcohol
Polyvinyl alcohol (PVA) is a linear polymer, used in a variety of medical products (e.g. eye drops). Here, the degree of alcoholysis is an important index for the water solubility, viscosity, and adhesion of the product. The degree of alcoholysis is defined as the percentage of hydroxyl functional groups compared to the total functional groups accessible in the molecule. Conventional alcoholysis determination can take up to six hours per sample. Compared to the primary method, analysis with near-infrared spectroscopy (NIRS) only takes one minute. The following application note describes the determination of the degree of alcoholysis by NIRS.
- WP-048Utilizing online chemical analysis to optimize propylene oxide production
Propylene oxide (PO) is a major industrial product used in assorted industrial applications, mainly for the production of polyols (the building blocks for polyurethane plastics). Several production methods exist, with and without co-products. This white paper lays out opportunities to optimize PO production for safer and more efficient processes, higher quality products, and substantial time savings by using online process analysis instead of laboratory measurements.
- AN-S-028ppb levels of anions
Determination of 1 (3) µg/L of chloride, nitrite, bromide, nitrate, phosphate, and sulfate after direct injection using anion chromatography with conductivity detection after chemical suppression.
- AN-NIR-092Quality Control of PVC foils
PVC (polyvinyl chloride) foils with a PVDC (polyvinylidene chloride) coating are often used for high performance packaging films like pharmaceutical blister packs or in food packaging. In multi-layer blister films, the PVC serves as the thermoformable backbone structure, whereas the PVDC coating acts as a barrier against moisture and oxygen. The Water Vapor Transmission Rate (WVTR) and Oxygen Transmission Rate (OTR) are influenced by the composition and the thickness of the coating. A fast way to monitor PVDC coating thickness is with near-infrared spectroscopy. Results are provided in a few seconds, indicating when adjustments in the polymer production process are necessary.
- AN-P-051Cyanide and sulfide on Metrosep A Supp 10 - 100/2.0 using amperometric detection
The determination of cyanide and sulfide in the trace range requires an alkali eluent and amperometric detection. This Application Note describes a new column/eluent combination for optimized separation. The combination consists of the Metrosep A Supp 10 - 100/2.0 Microbore Column and a sodium hydroxide eluent that contains traces of EDTA for the complexation of the transition metals. This yields a better peak shape and detection limits below 0.05 µg/L.
- AB-143Determination of complexing agents in detergents
Application Bulletin AB-076 contains a description of the polarographic determination of low concentrations (1–100 mg/L) of NTA and EDTA in bodies of water. NTA, EDTA and citrate have gained in importance as complexing agents and builders due to the fact that the laws of some countries have made it necessary to find a substitute for phosphates in detergents.This Bulletin describes the determination of larger quantities of complexing agents in detergents using potentiometric titration. The ion-selective copper electrode (Cu-ISE) is used here as the indicator electrode. The determination of complexing agents is not disturbed by the other constituents often present in detergents.
- AN-N-069Chloride and sulfate in an emulsion using Metrohm Inline Dialysis
Determination of chloride and sulfate in effluent after Metrohm Inline Dialysis using anion chromatography with direct conductivity detection.
- AB-134Determination of potassium with an ion-selective electrode
Potassium is one of the most common elements and can be found in many different minerals and other potassium compounds. It is of importance for humans, animals and plants as it is an essential mineral nutrient and involved in many cellular functions like cell metabolism and cell growth. For these reasons, it is important to be able to declare the potassium content of food or soil to reduce problems that may arise by a potassium deficiency or extensive consumption.This bulletin describes an alternative to flame photometric method using an ion selective electrode and direct measurement or standard addition technique. Several potassium determinations in different matrices using the combined potassium ion-selective electrode (ISE) are presented here. Additionally, general hints, tips and tricks for best measurement practice are given.
- AN-S-125Determination of complexing agents
Determination of NTA, HEDP, and ATMP using anion chromatography with conductivity detection after chemical suppression.
- AN-PAN-1054Online monitoring of hydrogen peroxide during the CMP process
The planarity and smoothness of silicon wafers are fundamental to manufacture optimal semiconductor devices, and Chemical Mechanical Planarization (CMP) is the most common technology used to achieve ultra-flat surfaces. A slurry is used for this purpose, composed of deionized water, a colloidal silicon or alumina liquid dispersion, and hydrogen peroxide, which has to be constantly monitored at all times.Online monitoring of the CMP process is necessary to avoid chemical waste and enhance wafer production yields. Metrohm Process Analytics can measure not only the H2O2 concentration, but also pH, conductivity, and temperature using the multipurpose 2060 Process Analyzer.
- 8.000.6063Post-column chemistry for improved optical absorption detection
UV/VIS detection is one of the most sensitive detection techniques in trace-level chromatography. Sometimes, however, spectrophotometric detection lacks sensitivity, selectivity or reproducibility and chemical derivatizations are required. By using Metrohm`s rugged and versatile flow-through reactor, single- or multi-step derivatizations can be done fully automatically, in either pre- or post-column mode at any temperature between 25…120 °C. The variable reactor geometry allows to adjust the reactor residence time of the reactants according to derivatization kinetics. The flexibility of the reactor is demonstrated by optimizing four widespread post-column techniques: the relatively slow ninhydrin reaction with amino acids and the fast derivatizations of silicate, bromate and chromate(VI).
- AN-N-070Sulfide in effluent
Determination of sulfide in an effluent sample using anion chromatography with amperometric detection.
- AN-S-057Acetate and benzoate in the presence of the standard anions
Determination of acetate, chloride, nitrite, nitrate, benzoate, phosphate, and sulfate using anion chromatography with conductivity detection after chemical suppression.
- AB-050Determination of lead in petroleum products by stripping voltammetry
The determination of the lead content in engine fuels has gained considerable importance since the introduction of the catalytic converter technique. Even small contents of lead interfere with the effectiveness of the catalysts or may destroy them. On the other hand, there are still many vehicles on the roads which run on leaded fuel (addition of tetraalkyl lead). Here also the knowledge of the lead content is of interest.With reference to DIN 51769 and ASTM 0-1269 a simplified procedure for the determination of lead in petrochemical products is described. The products are digested with HCl and the lead compounds are converted to lead(II) chloride. After extraction with water, the inverse voltammetric Pb determination is carried out.
- AN-H-147Potassium in fertilizers – Rapid and reliable determination by thermometric titration
Potassium is a primary macronutrient for plants, as it plays an important role in water regulation as well as plant growth. In NPK fertilizers, potassium is present besides nitrogen and phosphorus, which are the other two primary macronutrients. Knowing the quality and content of a NPK fertilizer allows an optimal fertilizer management for a planned culture, saving costs and increasing profitability.Traditionally potassium is determined gravimetrically or by flame photometry. In this Application Note, an alternative method is presented, where potassium is determined a precipitation titration. Various solid and liquid NPK fertilizers with potassium contents between 10 and 27% were analyzed. After the removal of any present ammonia, the potassium can be determined reliably in about 5 minutes.
- AB-130Chloride titrations with potentiometric indication
Potentiometric titration is an accurate method for determining chloride content. For detailed instructions and troubleshooting tips, download our Application Bulletin.
- AN-T-133Chloride in milk and milk powder
In order to maintain product quality, the sodium chloride content in dairy products must be monitored and not exceed the limits defined by the respective public health authorities. The chloride content in food correlates with the salt content, its determination is therefore described in various norms and standards. However, preparation of such samples is time consuming, as it includes a chloride extraction with warm water. Whole milk powders in particular are difficult to handle as an inhomogeneous dispersion of fat in the titration suspension occurs.In order to reduce the workload, increase sample throughput, and eliminate the matrix challenges posed by high fat products, this Application Note presents a fully automatic potentiometric titration of chloride with silver nitrate in milk and milk powder based on ISO 21422, IDF 242, AOAC 2015.07, AOAC 2015.08 and AOAC 2016.03
- 8.000.6016Advantages of multidimensional ion chromatography for trace analysis
The analytical challenge treated in the present work consists in detecting trace concentrations (ppb) of bromide in the presence of a strong chloride matrix. This problem was overcome by separating the bromide ions from the main fraction of the early eluting chloride matrix (several g/L) by applying two sequential chromatographic separations on the same column. After the first separation, the main fraction of the interfering chloride matrix is flushed to waste, while the later eluting anions are diverted to an anion-retaining preconcentration column. After elution in counter flow, the bromide ions are efficiently separated from the marginal chloride residues. The four-point calibration curves for bromide and sulfate are linear in the range of 10…100 µg/L and 200…800 µg/L and yield correlation coefficients of 0.99988 and 0.99953 respectively. For the method shown here, a second injection valve and a preconcentration column are the only additional devices needed to master this demanding separation problem.
- AN-C-126Methylamines and ethanolamines (Metrosep C 4 - 150/4.0)
Determination of monomethylamine (MMA), dimethylamine (DMA), trimethylamine (TMA), monoethanolamine (MEA), diethanolamine (DEA), and triethanolamine (TEA) using cation chromatography with direct conductivity detection.
- AN-U-061Speciation of iron(II) and iron(III) applying post-column reaction and subsequent UV/VIS detection
Speciation analysis is an important tool in analytical chemistry giving information about the quantitative distribution of different oxidation states of one and the same metal ion. The speciation of iron(II) and iron(III) (Fe 2+/Fe 3+) is achieved by ion chromatographic separation of their anionic dipicolinic acid complexes. Afterwards, post-column reaction with 4-(2-)pyridylazo-resorcinol (PAR) allows VIS detection at 510 nm.
- AN-C-078Ethanolamines in the presence of alkali metal and alkaline earth cations
Determination of mono-, di-, and trimethanolamine (MMA, DMA, TMA respectively), in the presence of lithium, sodium, ammonium, potassium, magnesium, cesium, calcium, and strontium using cation chromatography with direct conductivity detection.
- AN-O-017Glycolic acid, formic acid, acetic acid and carbonic acid in a scrubber solution
Determination of glycolic acid, formic acid, acetic acid and carbonic acid in a scrubber solution using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-S-071Traces of chlorite and nitrite using amperometric detection
Determination of chlorite and nitrite using anion chromatography with amperometric detection at the carbon paste electrode after chemical suppression.
- AN-S-158Five anions in the presence of 2 g/L nitrate in an ion exchanger eluate
Determination of traces of fluoride, acetate, formate, chloride, and sulfate in an ion exchanger eluate containing 2 g/L nitrate using anion chromatography with a step gradient and conductivity detection after chemical suppression.
- AN-S-298Arsenate in high-chloride and high-sulfate matrix by sample reinjection technique
The anion column Metrosep A Supp 15 - 150/4.0 is a pretty high-capacity column. The direct determination of arsenate in a matrix of 180 mg/L chloride and 320 mg/L sulfate is not possible, as the arsenate is hardly detectable under the sulfate peak tail. Sample reinjection cuts off the majority of the matrix and therefore allows an accurate determination of the arsenate.
- TA-052IC-ICP-MS analysis of iodized X-ray contrast media
On the basis of the experiments that have been performed, it is possible to determine the effectiveness of the ozonization of iodized X-ray contrast media using IC-ICP-MS via the amount of iodate formed. Whereas a 120-minute ozonization guarantees a practically quantitative decomposition of amidotrizoic acid to iodate, approximately 16% of the Iomeprol is still present under the same ozonization conditions. Given that only 14% is present in iodate form in the absence of iodide anions and given that additional, not yet identified peaks occur in the ion chromatogram, the presence of additional decomposition products containing iodine must be assumed. Nonetheless, it is not possible to detect the intact iodized X-ray contrast media with the selected ion chromatographic conditions. Furthermore, the possibility exists of identifying the peak of the unknown decomposition product of the Iomeprol using IC-ESI-TOF-MS.
- AB-188pH measurement technique
This Bulletin, using practical examples, indicates how the user can achieve optimum pH measurements. As this Bulletin is intended for actual practice, the fundamentals - which can be found in numerous books and publications - are treated only briefly.
- 8.000.6017Determination of sulfide in mining leachates
Metal precipitation and cyanide recovery in the SART process (sulfidization, acidification, recycling, thickening) depend to a great extent on the sulfide concentration. Among the flow injection analysis methods coupled to wet-chemical analyzers, the combination of a gas diffusion cell with an ion chromatograph (IC) plus subsequent direct spectrophotometric detection has proven to be one of the most convenient methods of sulfide analysis.This paper deals with the determination of sulfide anions via the coupling of a gas diffusion cell to an IC with subsequent spectrophotometric detection.
- AN-EC-042Studying zinc coatings with EQCM-D and EIS
Zinc coatings are widely applied for medical devices and to protect steel against corrosion. Electrodeposition, modulated by electrochemical parameters and tailored additives such as polyethylene glycol (PEG), enables control over coating morphology, with PEG shown to delay deposition and promote smoother surfaces. This Application Note demonstrates that EQCM-D, integrated with electrochemical methods, provides detailed insight into Zn deposition and additive effects, supporting process optimization for coating performance.
- AN-O-035Acetate and formate in amine solutions
Determination of acetate and formate in an amine solution using anion chromatography with conductivity detection after suppression.
- AN-P-058Amines in gas scrubber solutions using IC and pulsed amperometric detection
Scrubber solutions for scrubbing flue gas often contain amines for absorbing acid gases, e.g., sulfur dioxide (SO2). 1-(2-hydroxyethyl)piperazine and 1,4- Bis(2-hydroxyethyl)piperazine from gas scrubber solutions are separated in the Metrosep Carb 2 - 150/4.0 column and then determined using pulsed amperometric detection.
- AN-S-313Dual detection of nitrite traces in the presence of excess chloride concentrations with the aid of the 940 Professional IC Vario (conductivity, UV/VIS)
The determination of low nitrite concentrations in the presence of excess sodium chloride is demanding due to the small retention time difference of these two anions. Dual detection – conductivity and UV/VIS – is a powerful method for determining nitrite traces in a 20 g/L sodium matrix. The UV/VIS chromatogram displays no chloride interferences. The determination of ammonium traces in the presence of excess sodium is described in AN-C-145.
- AN-C-144Variable Inline Preconcentration including matrix elimination for trace cation determination (MiPCT-ME)
Metrohm Inline Preconcentration Technique with matrix elimination (MiPCT-ME) is a powerful method that combines preconcentration, matrix elimination, and multilevel calibration. In this Application Note, the methodology is applied to the determination of traces of sodium in addition to 2 mg/L ammonia. The Metrosep C 6 - 250/4.0 column is used for selectivity reasons.
- AB-074Determination of antimony, bismuth, and copper by anodic stripping voltammetry
This Application Bulletin describes the voltammetric determination of the elements antimony, bismuth, and copper. The limit of detection for the three elements is 0.5 ... 1 µg/L.
- 8.000.6071Trace-level determination of anions in the primary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The poster presents the ion chromatographic determination of organic degradation products such as glycolate, formate and acetate besides the standard anions fluoride, chloride, nitrate and sulfate.
- AB-196Determination of formaldehyde by polarography
Formaldehyde can be determined reductively at the DME. Depending on the sample composition it may be possible to determine the formaldehyde directly in the sample. If interferences occur then sample preparation may be necessary, e.g. absorption, extraction, or distillation.Two methods are described. In the first method formaldehyde is reduced directly in alkaline solution. Higher concentrations of alkaline or alkaline earth metals interfere. In such cases the second method can be applied. Formaldehyde is derivatized with hydrazine forming the hydrazone, which can be measured polarographically in acidic solution.
- AN-EC-037Differential electrochemical mass spectrometry
Differential electrochemical mass spectrometry (DEMS) is used to monitor gaseous and volatile species during electrochemical reactions in situ.
- AN-S-338Inline Ultrafiltration with Dosino backflush for highly contaminated tannery effluent
Inline Ultrafiltration is a proven sample preparation technique for samples that are slightly or massively contaminated with particles, algae or bacteria. Filtration and injection are coupled and fully automatic. As a rule, 100 or more samples can be filtered through a single membrane. Service life is extended – even with highly contaminated tannery effluent – to more than 300 injections because the filter membrane is rinsed again once more after the analysis with the aid of the Dosino backflush.
- AN-T-057Calcium in aqueous solutions by photometric titration
Determination of calcium in aqueous solutions by photometric titration with EDTA using the 610 nm Spectrode.
- 8.000.6072Trace-level determination of cations in the secondary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The presented IC system with inline sample preparation allows the determination of traces of lithium and sodium (ppt) in the presence of ppm quantities of ammonium and ethanolamine.
- AB-129Potentiometric determination of orthophosphates, metaphosphates, and polyphosphates
After acid digestion, the sample solution is neutralized with sodium hydroxide to form sodium dihydrogen phosphate. An excess of lanthanum nitrate is added and the released nitric acid is then titrated with sodium hydroxide solution.NaH2PO4 + La(NO3)3 → LaPO4 + 2 HNO3 + NaNO3This determination method is suitable for higher phosphate concentrations.
- AN-C-172Cations in snow from an open field
Cation content in snow is greatly dependent on sampling site. Samples from remote areas are expected to exhibit lower cation concentrations. This application shows the analysis of a snow sample from an open field in an agricultural zone. Separation is performed on a microbore Metrosep C 6 - 100/2.0 column with direct conductivity detection. The relatively high ammonia content can be explained by animal husbandry in the vicinity of the sampling site.
- AN-C-173Cations in roadside snow
Cation content in snow is greatly dependent on sampling site. Roadside samples are likely to exhibit a high sodium content caused by the use of road salt. This application shows the analysis of a snow sample from a roadside. Separation is performed on a microbore Metrosep C 6 - 250/2.0 column with direct conductivity detection. The 250 mm column was selected due to the large difference in concentrations between sodium and ammonia. This condition enables a baseline separation of the two cations.
- AN-C-132Traces of lithium, sodium, and ammonium in the presence of ethanolamine (Metrosep C 4 - 250/4.0)
Determination of lithium, sodium, ammonium, and monoethanolamine (MEA) using cation chromatography with direct conductivity detection and Metrohm Inline Preconcentration and Inline Calibration.
- WP-039Ion chromatography – addressing the latest challenges in environmental analysis
The analytical challenges of environmental analysis increase in difficulty from year to year. As well as analysis of particularly toxic types of metals such as chromium(VI), highly diverse and partially persistent organic fluorine compounds (e.g., trifluoroacetic acid) are presently in focus. The analysis of toxic oxohalides such as bromate and perchlorate is also a current subject of investigation.
- AB-176Determination of lead and tin by anodic stripping voltammetry
In most electrolytes the peak potentials of lead and tin are so close together, that a voltammetric determination is impossible. Difficulties occur especially if one of the metals is present in excess.Method 1 describes the determination of Pb and Sn. Anodic stripping voltammetry (ASV) is used under addition of cetyltrimethylammonium bromide. This method is used when:• one is mainly interested in Pb• Pb is in excess• Sn/Pb ratio is not higher than 200:1According to method 1, Sn and Pb can be determined simultaneously if the difference in the concentrations is not too high and Cd is absent.Method 2 is applied when traces of Sn and Pb are found or interfering TI and/or Cd ions are present. This method also uses DPASV in an oxalate buffer with methylene blue addition.
- WP-086Measuring organic acids and inorganic anions with ion chromatography mass spectrometry
This White Paper focuses on selected IC-MS applications for the straightforward identification and quantification of organic acids and inorganic anions in different matrices.
- 8.000.6101Analysis of Anions and Oxoanions using Ion Chromatography Mass Spectrometry (IC-MS)
Ion chromatography tackles difficult separation problems of various ionic species and typically works with conductivity detection. Mass detection as a secondary independent detector significantly lowers the detection limits and confirms the identity of analytes even when coeluting. This poster describes how the combination of IC-MS and automated sample preparation techniques cope with the analysis of anions and oxoanions in challenging matrices such as soil or explosion residues.
- AN-PAN-1010Online analysis of sulfuric acid and zinc sulfate in the viscose process
Monitoring sulfuric acid and zinc sulfate in the viscose wet-spinning process is essential. Online potentiometric titration and colorimetric analysis are recommended for this purpose.
- TA-016Determination of mercury and arsenic using speciation analysis (IC-ICP/MS)
The combination of ion chromatography and inductively coupled plasma mass spectrometry (IC-ICP/MS) is ideally suited for the detection of species of arsenic and mercury in their various oxidation levels and forms of chemical bonding. However, some species – as in the case of mercury – are reciprocally converted into one another during sample preparation, thus making a determination of the initial concentrations of the heavy metal species impossible. This article shows how these interconversions can be calculated with isotope dilution analysis and IC-ICP/MS in accordance with EPA method 6800.
- 8.000.6048Fully automated determination of fluoride in blood samples
Sodium fluoride is used as a preservative in biological samples for alcohol analysis. All submitted blood samples, including those taken from vehicle drivers suspected of driving under the influence of liquor, have to be tested for adequate preservation prior to alcohol determination by gas chromatography. This is critical to ensure adequate sample preservation. Inadequate sample preservation may allow glycolysis and/or microorganism growth to produce ethanol.In the past this has been done by direct potentiometric measurement using a fluoride-selective electrode (F ISE), an ion meter and certified NaF standards. The sodium fluoride level was determined manually by dipping the electrode directly into the blood sample. Results were recorded manually. This poster describes two independent automated methods of analysis that allow the minimization of this tedious and time-consuming procedure.In the first one, the fluoride content in a blood aliquot is measured by direct potentiometric measurement after the addition of TISAB and deionized water. The second method employs the titration of the sample aliquot with La(NO3)3 after adding a buffer solution.
- AN-R-020Antioxidant content in wheat germ oil, vitamin C tablet and body lotion – Fast determination of the antioxidant content by standard addition
Some samples, such as cosmetics and food, cannot be measured directly with the Rancimat as no evaluable induction time is obtained. There are many reasons for this, for example a high water content, a too low fat content or various matrix effects. However, using polyethylene glycol (PEG) as carrier material, many of these samples can be directly and reproducibly measured without sample preparation. This is due to the antioxidants that are naturally present in the sample matrix, and which stabilize the induction time of the PEG. The induction time can therefore be directly related to the oxidation stability of the sample.Furthermore, with a standard addition it is possible to measure the content of antioxidants (AOC) such as vitamin E, vitamin C or an equivalent of it. The decrease of the antioxidants over time (for example, during storage of the sample) can thus be measured and evaluated. In addition, this method eliminates a costly sample preparation. A reproducible and accurate determination of the oxidation stability using the 892 Professional Rancimat can be realized.
- AB-220Determination of platinum and rhodium in the ultratrace range by adsorptive stripping voltammetry
This Application Bulletin describes …
- AN-EC-011Investigation of intermediates in the electrodeposition of copper using the Autolab rotating ring disc electrode (RRDE)
Copper is arguably one of the most technologically relevant metals, especially for the semiconductor industry. The deposition process used in this industry is known as the dual-damascene process and it involves the electrodeposition of copper from an acidic cupric compound, in the presence of additives.This Application Note illustrates the use of the Autolab rotating ring disc electrode (RRDE) for the study of electrodeposition of copper and the detection of the Cu+ intermediate.
- AN-R-021Oxidation stability of cosmetics and personal care products – Fast determination of oxidation stability without sample preparation
The oxidation stability is an important factor for the quality of cosmetics. It also provides information about the long-term and storage stability of the product. Most cosmetic formulations cannot be measured directly with the Rancimat as no evaluable induction time is obtained. There are many reasons for this, for example a high water content, a too low fat content or various matrix effects. However, using polyethylene glycol (PEG) as carrier material, many of these samples can be directly and reproducibly measured without sample preparation. This is due to the antioxidants that are naturally present in the sample matrix, and which stabilize the induction time of the PEG. The induction time can therefore be directly related to the oxidation stability of the sample.In addition, this method eliminates a costly sample preparation. A reproducible and accurate determination of the oxidation stability using the 892 Professional Rancimat can be realized. In this Application Notes the oxidation stability of body care cream, moisturizer, body milk, body lotion, and toothpaste is determined in this way. More information on the Rancimat method can be found on the Metrohm website.
- 8.000.6010Inline sample preparation – An effective tool for ion analysis in pharmaceutical products
By means of azide analysis in Irbesartan a simple, fast, precise and accurate ion chromatographic method for the determination of traces of inorganic contaminants in pharmaceuticals is described. Traces of toxic azides in pharmaceutical products can accurately be determined in the sub-ppb range after Metrohm Inline Matrix Elimination using isocratic ion chromatography (IC) with suppressed conductivity detection. While the azide anions are retained on the preconcentration column, the interfering pharmaceutical matrix is washed away by a transfer solution, ideally consisting of 70% methanol and 30% ultrapure water. The analytical setup provides a well-resolved azide peak and thus alleviates the common drawback of excipient interferences, especially from the nitrate anion. Calibration with azide standards is linear over the range of 5…80 ppb, providing a coefficient of determination of 0.9995. The limit of detection (LOD) and the limit of quantification (LOQ) of azide in Irbesartan are 5 and 30 µg/L respectively; the relative standard deviations (RSD) for the peak area, peak height and retention time being smaller than 3.9%. Robustness testing involved variation of column oven temperature and composition of the transfer solution and, in terms of peak area, provided RSDs smaller than 2.8% and 3.1% respectively.
- EB-004Near-infrared and Raman spectroscopy for polymer analysis: An introduction
This e-book explains how Raman and near-infrared (NIR) spectroscopy enable rapid, nondestructive polymer analysis, ensuring high quality while reducing costs and waste.
- AN-S-144Heat stable salts in a scrubber solution
Determination of chloride, bromide, nitrate, sulfite, sulfate, phosphate, oxalate, thiosulfate, and thiocyanate (heat stable salts) in scrubber solutions using anion chromatography with conductivity detection after chemical suppression.
- AN-EC-033Utilizing hyphenated EC-Raman to study a model system
This Application Note presents a walkthrough of an experiment on 4-nitrothiophenol using hyphenated EC-Raman, a combination of Raman spectroscopy and electrochemistry.
- AN-EC-039Spectro-electrochemiluminescence study of simultaneous emission from two luminophores
Spectro electrochemiluminescence experiments comparing photodiode and microspectrometer detectors, showing how each sensor captures ECL signals for the analysis of single and dual luminophore systems.
- AN-H-071Determination of ammonium ions by titration with hypochlorite
Determination of ammonium ions in ammonium salts and mixtures containing ammonium ion.
- AN-K-048Sample preparation with the oven technique – relative blank
Large sample sizes can lead to subtraction of too high blank values. This Application Note describes the calculation of a relative blank and thus helps to improve the accuracy of the method.
- AN-T-085Photometric determination of sulfate
This Application Note describes the photometric determination of sulfate using the Optrode (610 nm). Sulfate is titrated with a lead nitrate solution; dithizone is used as indicator.
Did you know?
We manufacture customized sensors for your electrochemical research.
Show another