滴定/水分/イオンクロマトグラフィ/近赤外分析/ラマン分光/ポテンショスタット/ガルバノスタット/プロセス分析/pH/イオン/導電率/DO/酸化安定性試験/ボルタンメトリー/CVS
アプリケーション(技術資料)
イオンクロマトグラフィのお勧め技術情報!【コラム】ご隠居達のIC四方山話
※ 並び替えをz-a 順にすると、概要を日本語に訳したアプリケーションが上位に表示されやすくなります。
※ PDFドキュメントは英語版と日本語訳版の両方が混在しています。
※「日本語」というキーワードを入力すると、日本語訳版だけが表示されます。
- 8.000.6043Automated dialysis as a sample preparation tool in ion chromatography
The analytical challenge treated in the present work consists in the determination of chloride, phosphate and sulfate in the presence of difficult sample matrices that interact with the stationary column phase or even render it unusable. Metrohm`s patented stopped-flow dialysis coupled to the new 881 Compact IC pro ion chromatograph overcomes these drawbacks. Two standard solutions covering the concentration ranges 1.0…3.6 mg/L and 10…36 mg/L as well as two samples, an ultra-high temperature (UHT) processed milk and a baby milk powder, were characterized in terms of analyte concentration, relative standard deviation, calibration quality, carryover and recovery rates. While the five-point calibration curves yielded correlation coefficients (R) better than 0.9999, carryover (between two subsequent injections of a concentrated sample and a blank) was less than 0.49%. Recoveries for the low (10…36 mg/L) and high standard concentrations (1.0…3.6 mg/L) were within 91…99% and 94…100%, respectively. Automated compact stopped-flow dialysis is a leading-edge sample preparation technique that ensures optimum separation performance by effectively protecting the column from detrimental matrix compounds.
- 8.000.6064Microbore columns: a contribution to green chemistry
Available sample size, mass sensitivity, efficiency and the detector type are important criteria in the selection of separation column dimensions. Compared to conventional 4 mm i.d. columns, microbore columns excel, above all, by their low eluent consumption. Once an eluent is prepared, it can be used for a long time. Additionally, the lower flow rates of microbore columns facilitate the hyphenation to mass spectrometers due to the improved ionization efficiency in the ion source.With the same injected sample amount, a halved column diameter involves a lower eluent flow and results in an approximate four-fold sensitivity increase. In a converse conclusion, this means that with less sample amount, microbore columns achieve the same chromatographic sensitivity and resolution than normal bore columns. This makes them ideally suited for samples of limited availability.
- 8.000.6065Automated ion chromatographic determinations over six orders of magnitude
Metrohm`s intelligent Preconcentration Technique with Matrix Elimination (MiPCT-ME) excels in its capacity to perform automatic ion chromatographic determinations over 6 orders of magnitude. Crucial requirements for this are the system`s intelligence and the exact measurement of the sample volume. While the intelligence allows to compare results and take decisions, the dosing device takes over the high-precision liquid handling of even single-digit microliter volumes to the preconcentration column. By using only one analytical setup and without additional rinsing, samples containing both ultratraces and high concentrations can be analyzed.As the other Metrohm Inline Techniques, the MiPCT-ME technique presented reduces the workload, ensures complete traceability, is free of carryover effects and significantly improves accuracy and reproducibility of the results.
- 8.000.6073Determination of anions in concentrated nitric acid by ion chromatography: the influence of temperature on column selectivity
Determination of chloride and sulfate in the presence of high nitrate concentrations. Optimization of the chromatographic separation by variation of the temperature and eluent composition.
- 8.000.6076Sequential suppression for conductivity detection in ion chromatography
The poster describes how different suppressors (MSM and MCS) work and mentions possible applications.
- 8.000.6086Semi-continuous determination of anions, cations, and heavy metals in aerosols using PILS-IC-VA
This poster presents an approach that couples a Particle-Into-Liquid-Sampler (PILS) to a dual-channel ion chromatograph (IC) for measurement of aerosol anions and cations and a voltammetric measuring stand (VA) to determine the heavy metals. Feasibility of the PILS-IC-VA online system was demonstrated by collecting aerosol samples in Herisau Switzerland, at defined time intervals; air pollution events were simulated by burning lead- and cadmium-coated sparklers.
- AB-127Polarographic determination of nitrite in waters, meat and sausage products
Nitrite can be determined polarographically after its conversion to diphenylnitrosamine (C6H5)2NNO. Potassium thiocyanate is used as a catalyst in order for the conversion to proceed rapidly and quantitatively. The reaction takes place in acid solution at a pH value of approx. 1.5. The limit of quantification is 5 μg/L NO2-.
- AB-265Hamilton PRP-X100 IC anion column (6.1005.000)
This Bulletin describes the determination by ion chromatography of anions, particularly fluoride, chloride, nitrite, bromide, nitrate, and sulfate using the Hamilton PRPX100 IC anion column without chemical suppression.
- AN-D-001Metrohm IC Driver for OpenLab CDS
This application focuses on the simultaneous analysis of cations and suppressed anions with a dual channel Metrohm IC operated by OpenLab CDS.
- AN-D-003Quality control of dialysis concentrates
Ion chromatography (IC) provides an automated, fast, and sensitive solution to accurately quantify cationic and anionic components including acetate simultaneously. This comprehensive approach makes IC an economic alternative to traditional techniques for the quality control of pharmaceutical solutions like haemodialysis concentrates. Ease-of use, accuracy, and the high-throughput of IC increase productivity and comply with the demands of modern routine and research labs.
- AN-H-130Determination of nitrite using sulfamic acid
This Application Note describes the determination of nitrite using thermometric endpoint titration with sulfamic acid. The nitrite content of a solution can be analyzed down to 0.2 mmol/L.
- AN-N-014Five anions in effluent water
Determination of fluoride, chloride, nitrite, nitrate, and sulfate in an effluent sample using anion chromatography with direct conductometric detetction.
- AN-N-025Traces of nitrite, thiosulfate, and iodide using amperometric detection
Determination of traces of nitrite, thiosulfate, and iodide using anion chromatography with amperometric detection at the carbon paste electrode.
- AN-O-038Separation of various sulfur/nitrogen compounds using ion-pair chromatography
Determination of sulfite, nitrite, nitrate, sulfate, imidodisulfonate, and peroxodisulfate using ion-pair chromatography with conductivity detection after suppression.
- AN-PAN-1009自治体の下水・工業廃水分析用オンライン分析計
下水・工業廃水処理プラントでは、多数のパラメータを常時監視していなければなりません。これには、たとえば、重金属のカドミウム、鉛、亜鉛、コバルトのほか、硝酸塩、アンモニウム塩、リン酸塩、硫酸塩などのアニオンが含まれます。メトロームプロセスアナリティクスでは各種アナライザーを取り揃え、これらのアプリケーションに対応しています。202X プロセスアナライザーは、幅広い物質およびパラメータに対応した設定が容易に行え、信頼性の高いオンラインモニタリングが行えます。
- AN-PAN-1042Online trace analysis of anions in the primary circuit of nuclear power plants
Measures to monitor or prevent corrosion are crucial in nuclear power plants, where significant risks to health and safety can occur if corrosion is left unchecked. Anions corrode metals under high temperature and pressure, therefore their concentrations must be monitored at all times. The analytical challenge in the primary circuit is detection of anions in the μg/L range alongside gram quantities of boric acid and lithium hydroxide. Precise, reliable trace analysis requires the method to be automated as much as possible. The 2060 IC Process Analyzer from Metrohm Process Analytics can measure several anions from a single injection, with combined Inline Preconcentration and Inline Matrix Elimination to measure low anion concentrations precisely and reliably time after time.
- AN-Q-006加圧水型原子炉(PWR)のホウ酸塩水中の微量アニオンのオンライン分析
この技術資料では、可変濃縮とInline Matrix Elimination ( MiPCT-ME ) を組み合わせたInline Neutralization( インライン中和 )を使用することにより、注入前にほう酸を自動除去してからイオンクロマトグラフで微量アニオンを直接分析しています。
- AN-Q-008イオンクロマトグラフィーによる、蒸留水中の微量成分のモニタリング
940 Professional IC Vario、942 Extension Module Vario LQH、941 Eluent Preparation Module の組み合わせにより、イオンクロマトグラフィーを使用したプロセス監視が可能となります。ProfIC Vario 12 Anion の名称を持つこの組み合わせは、Metrohm Process IC の陰イオンバージョンです。サンプル前処理には、マトリックス除去機能を備えたインテリジェント濃度調整技術が使用されます。ELGA PURELAB® Flex 6 の使用により、特にサンプル量が多い場合でも、最高品質の超純水の供給を保証します。
- AN-S-005Six anions in cooling water
Determination of fluoride, chloride, nitrite, nitrate, phosphate, and sulfate in cooling water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-008地表水に含まれる陰イオン6種の分析
電気伝導度検出器付きイオンクロマトグによる地表水中のフッ化物、塩化物、亜硝酸塩、臭化物、硝酸塩、硫酸塩の測定アプリケーションです。
- AN-S-009Six standard anions in soil eluate
Determination of fluoride, chloride, nitrite, nitrate, and sulfate in soil eluates using anion chromatography with conductivity detection after chemical suppression.
- AN-S-020Nitrite and nitrate in wastewater
Determination of nitrite and nitrate in wastewater using anion chromatography with conductivity detection after chemical suppression.
- AN-S-028ppb levels of anions
Determination of 1 (3) µg/L of chloride, nitrite, bromide, nitrate, phosphate, and sulfate after direct injection using anion chromatography with conductivity detection after chemical suppression.
- AN-S-040Five anions in cutting oil emulsions using dialysis for sample preparation
Determination of chloride, nitrite, nitrate, phosphate, and sulfate in cutting oil emulsion using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-052Anions in rainwater
Determination of fluoride, chloride, nitrite, nitrate, and sulfate in rainwater using anion chromatography with conductivity detection after chemical suppression.
- AN-S-055Reproducibility of 18 injections in the ppb range on the Metrohm IC system using the MSM
Reproducibility of fluoride, chloride, nitrite, bromide, nitrate, and sulfate in the ppb range using anion chromatography with conductivity detection after chemical suppression.
- AN-S-071Traces of chlorite and nitrite using amperometric detection
Determination of chlorite and nitrite using anion chromatography with amperometric detection at the carbon paste electrode after chemical suppression.
- AN-S-100Nine anions in colored liquors
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfite, sulfate, and thiosulfate in colored liquors using anion chromatography with conductivity detection after chemical suppression.
- AN-S-103Five anions in water for infusion solutions
Determination of chloride, nitrite, bromide, nitrate, and sulfate in water for infusion solution production using anion chromatography with conductivity detection after chemical suppression.
- AN-S-108Five anions in an electroplating bath after inline elimination of heavy metals
Determination of chloride, nitrite, nitrate, phosphate, and sulfate in an electroplating bath after inline elimination of heavy metals by cation exchange on the 793 IC Sample Prep Module using anion chromatography with conductivity detection after chemical suppression.
- AN-S-109Six anions in Schoeniger absorption solution using the column Metrosep A Supp 5 - 150/4.0
Determination of chloride, nitrite, bromide, nitrate, phosphate, and sulfate in Schoeniger absorption solution using anion chromatography with conductivity detection after chemical suppression.
- AN-S-123Five anions in meat extracts
Determination of chloride, nitrite, nitrate, phosphate, and sulfate in a meat extract (Na2B4O7) after Carrez clearing using anion chromatography with conductivity detection after chemical suppression.
- AN-S-130Six anions in PVC
Determination of fluoride, chloride, nitrite, nitrate, benzoate, and sulfate in PVC film using anion chromatography with conductivity detection after chemical suppression.
- AN-S-133Four anions in wastewater after inline removal of excess chloride
Determination of nitrite, nitrate, sulfite, and sulfate in wastewater containing high levels of chloride using anion chromatography with conductivity detection after chemical suppression and after inline chloride removal.
- AN-S-135Eight anions in river water
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfite, and sulfate in river water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-147Ten anions in an extract of explosives
Determination of chloride, nitrite, cyanate, azide, nitrate, chlorate, sulfate, thiocyanate, thiosulfate, and perchlorate in an extract of explosives using anion chromatography with conductivity detection after chemical suppression.
- AN-S-149Anions in tripolyphosphate
Determination of chloride, nitrite, nitrate, phosphate, sulfate, trimeta-, and pyrophosphate in tripolyphosphate using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-154Eleven anions with high pressure gradient elution
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate, oxalate, thiosulfate, iodide, and citrate in a standard solution using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-156Chloride, nitrite, nitrate, and sulfate in cooling lubricants (conductivity and UV detection)
Determination of chloride, nitrite, nitrate, and sulfate in cooling lubricants using anion chromatography with conductivity and UV detection (230 nm) after chemical suppression and inline sample preparation by dialysis.
- AN-S-173Nitrite and nitrate in a plant extract
Determination of nitrite and nitrate in a plant extract using anion chromatography with conductivity detection after chemical suppression.
- AN-S-176Four anions in betaine
Determination of chloride, nitrite, nitrate, and sulfate in betaine using anion chromatography with conductivity detection after chemical suppression.
- AN-S-177Five anions in inositol
Determination of chloride, nitrite, bromide, nitrate, and sulfate in inositol using anion chromatography with conductivity detection after chemical suppression.
- AN-S-186Anions in wastewater containing N-methylpyrrolidone using inline matrix elimination
Determination of fluoride, acetate, formate, chloride, nitrite, nitrate, phosphate, and sulfate in wastewater containing N-methylpyrrolidone using anion chromatography with conductivity detection after chemical suppression and inline matrix elimination.
- AN-S-187Iodide in the presence of the standard anions in mineral water
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate, and iodide in a mineral water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-190Five anions in a strongly alkaline solution containing 70 g/L vanadate
Determination of chloride, nitrite, nitrate, phosphate, and sulfate in a strongly alkaline solution using anion chromatography with conductivity detection after chemical suppression.
- AN-S-191Chloride, nitrite, and sulfate in a used zinc bath containing cooling lubricants
Determination of chloride, nitrite, and sulfate in a used zinc bath using anion chromatography with conductivity detection after chemical suppression.
- AN-S-196Anions in water from an agricultural irrigation systems
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate in water from an agricultural irrigation system using anion chromatography with conductivity detection after chemical suppression.
- AN-S-199Selenite and selenate in the presence of the standard anions
Determination of fluoride, chloride, nitrite, selenite, phosphate, nitrate, sulfate, and selenate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-201Eight anions separated on column Metrosep A Supp 1
Determination of formate, chloride, nitrite, phosphite, phosphate, sulfite, nitrate, and sulfate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-215Qualitative determination of anions in urine to verify adulteration
Qualitative determination of chloride, phosphate, and sulfate as well as chlorite, nitrite, chlorate, bromide, and chromate in urine using anion chromatography with conductivity detection after chemical suppression.
- AN-S-218Common anions in a closed cooling water system
Determination of fluoride, chloride, nitrite, nitrate, and sulfate in a closed cooling water system using anion chromatography with conductivity detection after chemical suppression.
- AN-S-219Anions and organic acids in engine coolant
Determination of glycolate, formate, chloride, nitrite, nitrate, phosphate, sulfate, and oxalate in engine coolant using anion chromatography with conductivity detection after chemical suppression.
- AN-S-236Drinking water quality by EPA 300.1
Fast and reliable analysis of drinking water by combining EPA method 300.1 Parts A and B in a single IC run.
- AN-S-242原子力発電所(PWR)の一次系冷却水における陰イオンの微量分析 — メトローム インラインサンプル前処理を用いて
加圧水型原子炉(PWR)一次冷却水中のフッ素イオン、グリコール酸イオン、酢酸イオン、蟻酸イオン、塩化物イオン、亜硝酸イオン、硝酸イオンおよび硫酸イオンを、化学抑制後の導電率検出法を用いた陰イオンクロマトグラフィーにより定量し、Metrohm インラインキャリブレーションにて校正を行った。
- AN-S-24914 anions in an industrial process water
Determination of fluoride, acetate, propionate, formate, butyrate, chloride, nitrite, bromide, nitrate, benzoate, phosphate, sulfate, malonate, and oxalate in an industrial process water using anion chromatography with conductivity detection after sequential suppression.
- AN-S-254MISP – Metrohm Inline-Ultrafiltration – Cross Contamination < 0.1%
Determination of the cross contamination of 100 mg/L of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate to ultrapure water using anion chromatography with conductivity detection after chemical suppression and inline ultrafiltration.
- AN-S-255Sixteen anions separated on the column Metrosep A Supp 7 - 250/4.0 using gradient elution
Determination of fluoride, hypophosphite, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphite, phosphate, sulfate, arsenate, iodide, chromate, and perchlorate using anion chromatography with conductivity detection after gradient elution and chemical suppression.
- AN-S-265Semi-continuous determination of anions in aerosol using PILS-IC
Determination of chloride, nitrite, nitrate, and sulfate in an ambient aerosol (PM2.5) using aerosol sampling with the PILS (Particle Into Liquid Sampler) and anion chromatography with conductivity detection after sequential suppression.
- AN-S-267インラインマトリックス除去を用いた混合燃料 E85 (エタノール 85% およびガソリン 15%) 中の陰イオン
電気伝導度検出およびシーケンシャルサプレッション付き陰イオンクロマトグラフィによる混合燃料 E85 (エタノール 85% およびガソリン 15%) 中のフッ化物、酢酸塩、ギ酸塩、塩化物、亜硝酸塩、硝酸塩、リン酸塩および硫酸塩の測定を紹介しています。インラインマトリックス除去はサンプル前処理の役割を果たします。
- AN-S-269Mi-PT-メトロームインテリジェントパーシャルループ インジェクション
メトロームインテリジェントパーシャルループ インジェクションの技術は、イオンクロマトグラフィにおいて、標準溶液のうち1:100(例えば、2μL~200μL注入容量に対応する1μg/L~100μg/L)の可変注入を可能にします。可変注入の全範囲をサンプルに適用すると、1つのキャリブレーションは100倍のサンプル濃度範囲をカバーします。
- AN-S-270Impurities in syringe filters – Anions
Determination of fluoride, acetate, formate, chloride, nitrite, nitrate, phosphate, and sulfate impurities in syringe filters using anion chromatography with conductivity detection after sequential suppression.
- AN-S-272Column-switching method for anions in water samples with two different analytical requirements
Determination of fluoride, chloride, nitrate, phosphate, and sulfate on a short column or the ions mentioned plus bromate and nitrite on a long column in water samples applying intelligent column-switching using anion chromatography with conductivity detection after sequential suppression.
- AN-S-274イオンクロマトグラフによるインライン透析後の冷却潤滑剤中の主な陰イオンの分析
冷却潤滑油に含まれる主要な陰イオンをサンプル自動前処理システム(インライン透析)を使用して、時間のかかる前処理工程を自動化し、イオンクロマトグラフで測定したアプリケーションです。
- AN-S-275Formate, acetate, oxalate, and molybdate in the presence of standard anions
Determination of fluoride, formate, acetate, chloride, nitrite, bromide, nitrate, sulfate, oxalate, and molybdate using anion chromatography with conductivity detection after chemical suppression and Metrohm Inline Dialysis.
- AN-S-280Ten anions in an offshore effluent
Determination of acetate, chloride, nitrite, bromide, nitrate, phosphate, sulfate, oxalate, fumarate, and molybdate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-285Anions in coolant after Metrohm Inline Dialysis
Determination of fluoride, formate, chloride, nitrite, bromide, nitrate, sulfate, oxalate, and molybdate in a coolant using anion chromatography with conductivity detection after chemical suppression and Metrohm Inline Dialysis.
- AN-S-291Reproducibility of the Metrohm Suppressor Module (MSM)
The state-of-the-art tri-chamber suppressor technology provides a fresh suppressor chamber for each measurement. The complete regeneration of the chamber after each sample ensures highly efficient cation exchange – today, tomorrow, and even after years of continuous operation.The chromatograms as well as the statistical data demonstrate the outstanding reproducibility of the measurements with the Metrohm Suppressor Module.
- AN-S-296Anion Inline Eluent Preparation using an 849 Level Control
Eluent preparation on demand (EPOD) is the convenient and flexible way of automatic eluent preparation. The 849 Level Control together with an 800 Dosino equipped with a 50 mL dosing unit are used to dilute an eluent concentrate to the final eluent concentration. The use of eluent concentrates is suitable for any type of eluent. This facilitates unattended operation of the system over several weeks (see AN C-134 for cation eluent preparation).
- AN-S-299Standard anions in an ionic liquid (1-butyl-1-methylpyrrolidinium bis(trifluoromethane) sulfonimide).
Ionic liquids, also denominated as «designer solvents», are organic salts that are liquid at low temperatures. They are powerful solvents, conduct the electric current, and are therefore used in many applications. Anions, in particular halogenides, are common byproducts in the manufacturing of ionic liquids. Therefore, their concentration has to be controlled.
- AN-S-301Comprehensive water analysis with VoltIC pro I
VoltIC pro I is the perfect combination of voltammetry and ion chromatography for the fully automated analysis of anions, cations, and heavy metals (e.g., Zn, Cd, Pb, Cu): comprehensive water analysis on a single system.
- AN-S-304微量陰イオン分析のためのマトリックス除去を含む可変インライン前濃縮 (MiPCT-ME)
メトローム可変インライン前濃縮 (MiPCT-ME) は、前濃縮、マトリックス除去、およびマルチレベル校正を組み合わせた強力なツールです。後者では、単一のマルチイオン標準溶液のみが必要です。800 Dosino はすべての液体処理タスクを引き継ぎます。このシステム設定では、0.1 µg/L から最大 1.0 mg/L までのサンプル分析が可能です。
- AN-S-313Dual detection of nitrite traces in the presence of excess chloride concentrations with the aid of the 940 Professional IC Vario (conductivity, UV/VIS)
The determination of low nitrite concentrations in the presence of excess sodium chloride is demanding due to the small retention time difference of these two anions. Dual detection – conductivity and UV/VIS – is a powerful method for determining nitrite traces in a 20 g/L sodium matrix. The UV/VIS chromatogram displays no chloride interferences. The determination of ammonium traces in the presence of excess sodium is described in AN-C-145.
- AN-S-317Determination of ions on surfaces of printed circuit boards
Cleanliness is indispensable in electronics production. Ionic contaminations in particular lead to a drastic worsening of the quality of the printed circuit boards. The present Application Note describes the determination of anions on printed circuit board surfaces. The intelligent Partial Loop Injection Technique (MiPT) used for this purpose permits the determination of cations and anions in the same sample. The determination of the cations is described in AN-C-149.
- AN-S-329Anions in FDG gypsum in accordance with VGB-M 701e (consultative document of European Technical Association for the Generation of Electricity and Heat)
FDG gypsum originates from flue gas desulfurization systems in power plants. VGB-M 701 E (2008) describes aqueous extraction methods for determining chloride in FDG gypsum using ion chromatography. The sample preparation described in the VGB permits the determination of other anions besides chloride.
- AN-S-331マイクロボア陰イオンカラム Metrosep A Supp 5 を用いた 7種の標準陰イオンからの分離
マイクロボア陰イオンカラム Metrosep A Supp 5 は、150mmと250mmのものがあります。7種標準イオンの分離時間は、それぞれ20分、29分となっています。マイクロボアカラムは分離に対する有利な特性を有し、分離時間が短い上に、消費する溶離剤の量は4mmの同等器具より約75%少ないものとなっています。
- AN-S-332インライン限界ろ過とインライン溶離剤調合を伴う Metrosep A Supp 5 - 250/2.0 のカラムの安定性
Metrosep A Supp 5 - 250/2.0 マイクロボアバージョンのカラムの安定性に関して、長期間に渡るラボ試験による調査が行われました。6日間連続で、それぞれ2セットのインジェクションが行われました。それぞれのセットは水道水のインジェクション9回、検査基準のインジェクションが3回、そして水道水のインジェクション6回から構成されています。それぞれ7日目には、イオンクロマトグラフィシステムをシャットダウンしました。ICシステムは計12週間以上稼働し、計2650回のインジェクションが行われました。その結果は傑出した再現性を示し、カラムの高度な安定性が立証されました。
- AN-S-335インライン限界ろ過とインライン溶離剤生成後の Metrosep A Supp 5 - 250/4.0 のカラムの安定性
カラム Metrosep A Supp 5 - 250/4.0 の安定性に関して、長期間に渡るラボ試験による調査が行われました。6日間連続で、それぞれ2セットのインジェクションが行われました。それぞれのセットは水道水のインジェクション9回、検査基準のインジェクション3回、そして水道水のインジェクション6回から構成されています。それぞれ7日目には、ICシステムをシャットダウンしました。ICシステムは計10週間以上稼働し、計2150回のインジェクションが行われました。その結果は傑出した再現性を示し、カラムの高度な安定性が立証されました。
- AN-S-341標準陰イオンおよび有機酸、並びに4-ヒドロキシ酪酸の測定
4-ヒドロキシ酪酸(GHB)はヒドロキシカルボン酸に属し、多くの国で違法な向精神薬として使用されています。GHBはサプレッションを伴う陰イオンクロマトグラフィによって測定することができます。カラムMetrosep A Supp 16 - 250/4.0を使用し、ここで示している条件で測定すると、イオンクロマトグラフィで、GHBを標準陰イオンおよびグリコール酸、酢酸塩、ギ酸塩などといった有機酸陰イオンから分離できます。
- AN-S-347VoltIC Professional 1を用いた包括的な水の分析
VoltIC Professional 1は、陰イオン、陽イオン、重金属(例えばZn、Cd、Pb、Cu)の完全自動同時分析のために、ボルタンメトリー(VA)とイオンクロマトグラフィを組み合わせた分析システムです。マルチパラメーター分析では、同じ「リキッドハンドリング」装置と共有のサンプルチェンジャーを用いて、スペースとコストを節約できます。
- AN-S-353Eco ICを使用した飲料水のアニオン分析
メトロームのイオンクロマトグラフ Eco ICは、水のルーチン分析に最適なエントリーモデルのイオンクロマトグラフです。伝導度検出器やケミカルサプレッサも標準装備されています(サプレッサは使用してもしなくても操作できます)。上記クロマトグラフでは、Metrosep A Supp 17 - 150/4.0カラムを使用してアニオン分析を行っています。カラムは、室温での水分析専用カラムになります。
- AN-S-361インラインマトリックス除去を使用したエルトロンボパグ中の亜硝酸塩の測定
エルトロンボパグは、血小板減少症におけるある一定の条件下において用いられる医薬品です。それ自体では希少疾病用医薬品です。エルトロンボパグの分子は、プロトン化芳香族カルボキシル化合物です。イオンクロマトグラフィの条件下 (アルカリ溶離液) では、脱プロトン化されるため、イオン交換体の位置を妨げることがあります。その結果、保持時間の低下における超過時間に繋がります。これを防ぐため、インラインマトリックス除去を使用し、プロトン化エルトロンボパグを注入前に濃縮カラムから洗い落とします。その後、シーケンシャルサプレッションを通して電気伝導度検出器により亜硝酸塩の分析が行われます。
- AN-S-364インライン限外ろ過を適用したEN ISO 10304-1に準じた水中の溶解陰イオン
EN ISO 10304-1は、水サンプル中の7つの標準陰イオンの測定にとって最も重要な規格の1つです。ICによる陰イオン測定が必要な場合は、他の多くの規格でEN ISO 10304-01を参照します。この規格は、必要に応じて、細菌および固形物を避けなければならないサンプルのために皮膜ろ過を求めるものです。このアプリケーションは、インライン限外ろ過を適用し、EN ISO 10304-1に準拠した陰イオンの測定について示しています。この設定は面倒な手作業のサンプルろ過を避け、どのサンプルも完全に自動で処理します。
- AN-S-365濃縮半導体級水酸化アンモニウム中の陰イオン不純物
この技術資料では、イオンクロマトグラフを使用した、半導体グレード28%水酸化アンモニウム溶液に含まれる陰イオン不純物の測定について紹介しています。サンプルマトリックスの妨害を避けるため、サンプルマトリックス除去を伴うインライン中和およびインライン予備濃縮を使用しています。
- AN-S-368MSM洗浄の最適な方法 STREAM – マトリックスに鉄およびアルミニウムが含まれる場合でも
イオンクロマトグラフィにおいて、STREAM (測定後の溶離液再利用によるサプレッサ処理) はかなり以前から用いられています。サプレッションを受けた溶離液によるサプレッサ洗浄は、超純水による洗浄よりも優れています: より小さいウォーターディップ、より速いMSMの平衡化、水の追加供給の回避は、ほんの数例です。硫酸の再生における、マトリックスに鉄を含むサンプルの注入により、ピーク領域の縮小、およびリン酸により広いピークが生じます。硫酸およびシュウ酸をベースとした再生溶液の切り替えにより、MSMの完全な再生が可能となります。上記のオーバーレイは、ひとつのMSMチャンバーに10 mg/Lの鉄(II)が300回以上注入された後に、後で記録された3つのクロマトグラムを示しています。ピーク形状またはピーク領域に違いは見られません。
- AN-S-377タンデム式の電気伝導度および UV 検知を用いた IC による高濃度イオン水中の陰イオンの測定
「高濃度イオン水」とは一般的に高濃度の塩素を含む水 (例えば海水や塩水など) を指しますが、これはまた、石油化学プロセスによって生じる水サンプルを指すこともあります。高濃度の塩化物の存在により、微量なイオン成分の電気伝導度測定は限定されます。したがって、亜硝酸塩、臭化物、および硝酸塩などといった微量な陰イオンは、大きな塩素ピークの下やその裾に沿って溶出するため、低濃度での検知が妨げられます。しかしながら、ASTM D8234 にて紹介されている電気伝導度と UV/VIS 検知の組み合わせにより、UV 活性の陰イオンの測定が可能となります。この状況では、塩化物が干渉することはありません。この手法により、高濃度の塩化含有物のほかに微量の陰イオンを干渉なく同時に測定することが可能となります。
- AN-S-378タンデム式電気伝導度および UV 検知を用いた 精製プロセス水中の陰イオンの測定
ASTM D8234 では、UV/VIS 検知の後続する抑制電気伝導度を用いた高濃度塩水中の陰イオンの測定について説明されています。この組み合わせは、UV 検知による亜硝酸塩などの測定が可能となります。電気伝導度検知により、この定量化は不可能となるか、あるいは塩化物ピークが非常に大きくなるために困難となります。この技術資料では、塩化物の含有量の高い精製プロセス液をサンプルとしています。サンプルには有機物をも含んでいるため、分離カラムを保護するためにインライン透析をおこなっています。2つの検知モードとインライン透析オプションの組み合わせにより、手動でのサンプル前処理は軽減され、分析精度は実質向上します。
- AN-S-382Metrohm IC Driver for OpenLab CDS: ソフトドリンクにおける陰イオンと陽イオンの分析
OpenLab CDS は、1つのソフトウェアプラットフォームにクロマトグラフィと質量分析法を組み合わせた Agilent 社によるクロマトグラフィーデータシステムの最新世代です。Metrohm IC Driver for OpenLab CDS は、全制御およびデータ取得のための Metrohm IC 装置を統合したものです。この技術資料では、デュアルチャンネル IC システムを用いたソフトドリンク中の陰イオンと陽イオンの同時分析について紹介しています。溶離液は、インライン溶離液製造を用いて準備されます。
- AN-S-383Metrohm IC Driver for OpenLab CDS: Dose-in グラジェントおよび Dosino 再生による陰イオンの測定
OpenLab CDS は、Agilent 社によるクロマトグラフィーデータシステムの最新世代です。Metrohm IC Driver 1.0 for OpenLab CDS は、全制御およびデータ取得のための OpenLab CDS における Metrohm イオンクロマトグラフを実行します。このアプリケーションでは、グラジェント (Dose-in グラジェント) の使用ならびに OpenLab CDS における Dosino 再生が示されています。標準液中のフッ化物、塩化物、亜硝酸、臭化物、硝酸塩、硫酸塩、リン酸塩、およびヨウ化物が分離され、測定されます。
- AN-S-391高度なインラインマトリックス除去を使用したディーゼル中の陰イオンの測定
ディーゼル燃料、特にバイオディーゼル燃料中のアニオンは、エンジンに有害な堆積物を引き起こす可能性があります。イオンクロマトグラフィを用いた定量には、ディーゼルのアニオンを水溶液に転移し、ICに注入可能な状態にする必要があります。アニオンを水に転移させる典型的な方法は、インライン抽出を行い、その後インラインダイアライシスを行い、注入前にアニオンを水溶液に転移させることです(関連する陽イオンの分析についてはAN-C-101を参照)。実際のマトリックス除去法では、イソプロパノールで希釈したディーゼルをイソプロパノール流に注入し、予備濃縮カラムを通過させます。イソプロパノールがディーゼルを洗い流し、その後の超純水での洗浄工程で余分なイソプロパノールを除去します。
- AN-S-392化学溶液中のヒドラミンと他の陰イオン、並びにスルファミン酸の測定
スルファミン酸は、脱スケール剤や、搾乳装置や醸造装置の洗浄に用いられる適度な強酸です。この技術資料では、スルファミン酸塩、塩化物、亜硝酸塩、硝酸塩、および硫酸塩について化学溶液がイオンクロマトグラフで分析されています。溶液にはヒドラミンが含まれることがあるため、対象のイオンからの効率的な分離が要されます。
- AN-S-393過酸化水素と水酸化アンモニウム中の陰イオンの測定
半導体の製造工程では超高純度の化学薬品が必要とされます。化学薬品の純度は、パーツの品質ならびに効率的な製造には欠かせません。この技術資料では、過酸化水素と水酸化アンモニウムが、超純水を使用した分解ならびに蒸発といった従来のサンプル前処理工程を行い分析されます。得られたサンプルは、インテリジェント濃縮テクニック (MiPCT) を用いて注入されます。
- AN-S-395法医学研究におけるイオンクロマトグラフィの応用例
サプレッサを伴った伝導度検出器を搭載したイオンクロマトグラフィ(IC)では、一般的な無機アニオンに加えて、塩酸塩、チオ硫酸塩、チオシアン酸塩、過塩素酸塩などの陰イオン汚染物質を広範囲の濃度範囲で感度良く、堅牢に定量することができます。
- AN-S-397溶液用塩化ナトリウム錠剤中の塩化ナトリウムの IC アッセイ
滴定の代わりに、導電率検出を抑制したイオンクロマトグラフィ (IC) が、溶液または経口用の NaCl 錠剤の塩化物含有量を定量する有効な方法として USP によって承認されています。
- AN-S-400亜硝酸ナトリウム中の亜硝酸塩の分析
シアン化物中毒の重症例では、治療のために亜硝酸ナトリウムがチオ硫酸ナトリウムとともに使用されます。この技術資料では、Metrosep A Supp 4 カラムと抑制された導電率検出を使用した亜硝酸イオン クロマトグラフィ アッセイについて説明します。このカラム同等性研究は、USP General Chapter <621> に従って USP と協力して行われました。
- AN-S-401イオンクロマトグラフィによるデュロキセチン塩酸塩 API 中の亜硝酸塩の測定
医薬品中のニトロソアミンの存在は、たとえ微量レベルであっても、患者に対して高い安全性リスク(発がん性)をもたらします。ニトロソアミンの生成は、医薬品および物質中の亜硝酸塩濃度を制御および監視することで回避できます。この技術資料では、イオンクロマトグラフィ (IC) を使用したデュロキセチン塩酸塩中の亜硝酸塩の分析について紹介しています。
- AN-S-402イオンクロマトグラフィによるヒドロキシプロピルメチルセルロース中の亜硝酸塩の測定
ニトロソアミンの生成は、医薬品およびプロセス中の亜硝酸塩濃度を制御することで回避できます。ニトロソアミンの生成をモニタリングするには、医薬品や物質中の亜硝酸塩を定量するためのイオンクロマトグラフィなどの高感度の分析方法が不可欠です。
- AN-S-403Anions in lithium-ion battery solvents
N-Methylpyrrolidone (NMP) is crucial for lithium-ion battery production. Metrohm’s intelligent Preconcentration Technique with Matrix Elimination enables µg/L-level anion analysis in NMP.
- AN-S-404EPA 300.1準拠によるイオンクロマトグラフを使用した水の品質管理試験
メトロームのイオンクロマトグラフは、Metrosep A Supp 21カラムと溶離液自動生成装置 948 Continuous IC module CEPを組み合わせることで、水中の主要アニオンと消毒副生成物を効率的に自動分析できます。
- AN-T-062亜硝酸塩溶液の分析
亜硝酸塩は、水溶液中での電位差逆滴定により定量します。過剰に加えた過マンガン酸カリウムを、硫酸第一鉄アンモニウム(モール塩)で滴定し、Pt-ティトロードを用いて測定します。
- AN-U-009Iodate, chlorite, bromate, and nitrite by suppressed ion chromatography using a post-column reaction (PCR) and UV/VIS detection
Determination of iodate, chlorite, bromate, and nitrite using suppressed anion chromatography with UV/VIS detection after post-column reaction.
- AN-U-010Nitrite, nitrate, and phosphate in seawater from a shrimp farm
Determination of nitrite, nitrate, and phosphate in seawater from a shrimp farm using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection.
- AN-U-022Traces of nitrite in mineral water with UV detection
Determination of nitrite in mineral water using anion chromatography with UV detection.
- AN-U-023Nitrite, bromide, nitrate, and iodide in 10 g/L sodium chloride with UV detection
Determination of nitrite, bromide, nitrate, and iodide in 10 g/L sodium chloride using anion chromatography with UV detection.
- AN-U-047サンプル自動前処理(インライン透析)を使用したイオンクロマトグラフィーによる冷却潤滑剤中の硝酸塩と亜硝酸塩の測定
イオンクロマトグラフでサンプル自動前処理システム(インライン透析)をを使用し、時間のかかるサンプル前処理工程を自動化して、冷却潤滑剤中の硝酸塩と亜硝酸塩を自動分析したアプリケーションです。
- AN-U-056Nitrite, bromide, and nitrate in artificial sea water applying direct UV/VIS detection
Seawater analysis with conductivity detection is difficult due to the high excess of chloride. Especially analyzing for nitrite and bromide, UV/VIS detection is preferred as chloride is not interfering with nitrite at 218 nm. This AN shows the determination of all three UV-absorbing anions in an artificial seawater.
- AN-U-071UV/VIS検出器を用いた人工海水に含まれる亜硝酸塩、臭化物、および硝酸塩の測定
海水中の陰イオンのイオンクロマトグラフによるトレース分析は、高濃度の塩化物のため困難です。塩化物とは対照的に、亜硝酸塩、臭化物および硝酸塩は、波長域の低いUV照射を吸収し、これら3つの陰イオンのUV検出を可能にします。 この Application Note は、塩化ナトリウム溶液によるカラム型Metrosep Carb 2 - 100/4.0における分離について説明しています。これは、過剰塩化物による影響を最小限に抑え、低い検出限界を実現します。
- AN-U-074UV/VIS検出を伴うイオンクロマトグラフィーによるタバコ中の亜硝酸塩および硝酸塩の測定
タバコに含まれる亜硝酸塩は、タバコ特有のニトロソアミンの解放を促進します。これらニトロソアミンの多くは発がん性を有します。そのため、タバコに含まれる亜硝酸塩の測定が必要とされます。この application では、タバコの酢酸抽出物における亜硝酸塩および硝酸塩の測定について説明しています。イオンクロマトグラフィーによる分離の後、連続サプレッションを伴うUV/VIS検出が実施されます。
- AN-U-080Nitrite and nitrate in meat products
Nitrite and nitrate salts are used as preservatives for meat and meat products. Nitrate salts (labeled E 251 or E 252) have a low toxicity but long-term exposure is of concern, as the lower gut reduces them to nitrite, a precursor of nitrosamines (classified as carcinogenic). Nitrite itself is classified as probably carcinogenic to humans. The European Food Safety Authority (EFSA) lists the MPL (maximum permitted levels) after the manufacturing process for nitrite (labeled E 249 or E 250) as between 50–180 mg/kg, and for nitrate between 150–300 mg/kg, depending on the product. The European Commission (Regulation (EC) No 1333/2008) limits nitrate and nitrite salts in processed meat to less than 150 mg/kg. Ion chromatography with UV detection offers a robust and universal method for quality control of nitrite and nitrate in different meat matrices. Additional sample preparation techniques like Inline Ultrafiltration help to save time and costs as well as overcome analysis issues with difficult sample matrices.
- TA-054Online monitoring of atmospheric inorganic gases and aerosols in the Southeast and Northwest of the United States
This article describes the composition of atmospheric inorganic gases and aerosols in the Southeast and Northwest of the United States during a time period of several weeks. The semicontinuous sampling in hourly cycles takes place using the MARGA system from Metrohm Applikon. The temporal resolution of the aerosol and gas composition makes it possible to generate statements regarding the chemical origin and hygroscopicity of the particles. These are fundamental for rating the influence of aerosols on the climate.
- WP-009US EPA メソッド 300(米国環境保護局)に準拠した水道水に含まれる陰イオンの測定
この技術資料は、US EPA Series Method 300 part A(米国環境保護局 300 part A)に準拠して、7種の標準陰イオン(フッ化物、塩化物、亜硝酸塩、臭化物、硝酸塩、リン酸塩、硫酸塩)測定用の簡単な測定方法について解説しています。このICシステムには、インラインウルトラフィルタレーションとインライン溶離剤生成オプションがついています。
- WP-045HPLC が失敗する場合: 食品、水、医薬品分析における IC
高速液体クロマトグラフィー (HPLC) およびイオンクロマトグラフィー (IC) は、サンプル中の特定の成分を分析したり、規格および基準への適合性を検証するため、医薬品、食品、環境分野で一般的に用いられます。しかしながら、標準陰イオンまたは特定の医薬品中の不純物の分析などにおいて、HPLC のユーザーはこの技術の限界に突き当たる場合があります。このホワイトペーパーでは、このような課題を IC を用いていかに克服できるかについて概説しています。
- WP-088Simplified analysis of dairy products with Metrohm Inline Dialysis
This White Paper compares automated Inline Ultrafiltration and Inline Dialysis to the traditional Carrez clarification procedure for the analysis of milk samples by ion chromatography (IC). A continuous test series over approximately six months proved Inline Dialysis to be a reliable and valuable alternative to treat dairy products prior to IC analysis.