滴定/水分/イオンクロマトグラフィ/近赤外分析/ラマン分光/ポテンショスタット/ガルバノスタット/プロセス分析/pH/イオン/導電率/DO/酸化安定性試験/ボルタンメトリー/CVS
アプリケーション(技術資料)
イオンクロマトグラフィのお勧め技術情報!【コラム】ご隠居達のIC四方山話
※ 並び替えをz-a 順にすると、概要を日本語に訳したアプリケーションが上位に表示されやすくなります。
※ PDFドキュメントは英語版と日本語訳版の両方が混在しています。
※「日本語」というキーワードを入力すると、日本語訳版だけが表示されます。
- 410000061-AIdentification of Starting Materials in Pharmaceutical industry using STRam®-1064
100% starting materials identification testing is one of the FDA’s directives as per 211.84 for FDA regulated industries such as Pharmaceutical, Vaccines, Cosmetics, Tobacco, Animal veterinary products, Food, etc. STRam®-1064 is a Raman analyzer uniquely suited for this purpose. It measures samples through thick packaging materials such as plastics, multilayer kraft paper sacks, and HDPE containers. A long wavelength laser is used to suppress fluorescence. The ID algorithm isolates the sample signature by subtracting that of the packaging material and compares that with library spectra to achieve identification.
- AB-027Potentiometric titration of chloride and bromide in the presence of each other
If chloride and bromide are present in approximately equal molar concentrations they can be titrated directly with silver nitrate solution after addition of barium acetate. If, however, the molar ratio n(Br-) : n(Cl-) changes from 1 : 1 to 1 : 5, 1 : 10, 5 : 1 or 10 : 1 then greater relative errors must be expected with this method. The Bulletin describes an additional titration method that allows bromide to be determined in the presence of a large excess of chloride. The determination of small chloride concentrations in the presence of a large excess of bromide is not possible by titration.
- AB-082イオン選択性電極を用いたフッ化物の測定
本文では、フッ素イオン選択性電極 (F-ISE) を用いた、様々なマトリックス内のフッ化物の測定について説明します。F-ISE はフッ化ランタン単結晶で作られており、幅広いフッ素濃度範囲においてネルンスト効果を示します。本文の第一部には、電極の操作法や手入れに関して、および実際のフッ素測定における注記が記載されています。第二部では、食塩、歯磨き粉、洗口液における、標準添加技術によるフッ化物の直接的な測定について説明しています。
- AN-C-031Calcium and magnesium in high-purity sodium chloride
Determination of calcium and magnesium in high-purity sodium chloride using cation chromatography with direct conductivity detection.
- AN-C-063Five cations in lithium bromide using post-column reaction
Determination of nickel, zinc, cobalt, iron(II), and manganese in lithium bromide using cation chromatography with UV/VIS detection (520 nm) after post-column reaction with PAR.
- AN-C-071Choline in a saline solution
Determination of sodium, potassium, DMEA (dimethylethanolamine), calcium, choline, and magnesium in a saline solution using cation chromatography with direct conductivity detection.
- AN-C-181USPに則した酒石酸水素カリウム中のカリウム
USPモノグラフ近代化の範囲内では、カリウムは直接電気伝導度検出を伴う陽イオンクロマトグラフィーを用いて、酒石酸水素カリウム中で測定されます。「酒石酸水素カリウム」のためのUSP41 モノグラフでは、カリウムのアッセイにはまだ触れられていません。分離はMetrosep C 6 - 150/4.0カラム (L76) にて実施されます。カリウムのアッセイは、USPの定義に従って、市販の2つの製品を用いて実施されます。全ての認定基準を満たしています。
- AN-C-182USPに則した酒石酸ナトリウムカリウム中のカリウム
USPモノグラフ近代化の範囲内では、カリウムは直接電気伝導度検出を伴う陽イオンクロマトグラフィーを用いて、酒石酸ナトリウムカリウム中で測定されます。「酒石酸ナトリウムカリウム」のためのUSP41 モノグラフでは、カリウムのアッセイにはまだ触れられていません。分離はMetrosep C 6 - 150/4.0カラム (L76) にて実施されます。カリウムのアッセイは、USPの定義に従って、市販の2つの製品を用いて実施されます。全ての認定基準を満たしています。
- AN-C-191酢酸ランタン中のナトリウム
ランタン (La) は、空気中で酸化ランタン(III)へと酸化しやすい遷移金属です。この酸化物、並びにそれが酸に溶解し再結晶した結果の塩も、様々な触媒の構成成分です。ここでは、酢酸に酸化ランタン(III)を溶解して作られた酢酸ランタン(III)溶液は、ナトリウム汚染について検査されなければなりません。高濃度の La3+ は溶離液中のジピコリン酸によって錯体化し、陰イオン錯体を形成します。これらの錯体は前部で溶離され、そのためナトリウム不純物、およびアンモニウムやカルシウムといった他の陽イオンを干渉することがありません。
- AN-CS-011ヘキサフルオロリン酸リチウム(ヘキサフルオロリン酸リチウム︔LiPF6)に含まれる微量陽イオン
ヘキサフルオロリン酸リチウム(LiPF6)は、再充電可能なバッテリーにおいて電解質として使用されています。特に非極性溶媒中での高い溶解性と配位性ではない特性により、ヘキサフルオロリン酸リチウムはリチウムイオン電池に最適な塩です。この技術資料では、連続サプレッション後に電気伝導度検出器を備えたイオンクロマトグラフによるLiPF6中の微量陽イオンの測定について紹介しています。
- AN-EIS-009Mott-Schottky Analysis
This Application Note presents the Mott-Schottky measurement, an extension of electrochemical impedance spectroscopy (EIS), on a popular semiconducting material.
- AN-H-050Determination of sodium and potassium silicates
Determination of sodium, potassium, and silica values in sodium and potassium silicates.
- AN-H-055Analysis of sodium and phosphorus in sodium tripolyphosphate precursor solutions
Determination of Na, P, and [Na]/[P] in precursor solutions and solids in the manufacture of sodium tripolyphosphate.
- AN-H-061Direct titration of sodium
Determination of sodium in salts, process solutions, and foods.
- AN-H-092Analysis of zirconium acetate
Automated determination of the zirconium content of zirconium acetate, as well as other zirconium compounds which can be rendered soluble as zirconium acetate.
- AN-H-097Determination of calcium and magnesium in harvested salt
A measured amount of salt is titrated directly with a solution of 1 mol/L tetrasodium EDTA to thermometrically determined endpoints for Ca and Mg. Acetylacetone is added to alter the Ca and Mg EDTA stability constants for better endpoint sharpness.
- AN-H-111Determination of sulfate in harvested salt
Sulfate is precipitated as barium sulfate by reaction with an acidified barium chromate solution. The excess barium chromate is precipitated by basification with ammonia solution. Residual soluble chromate, equivalent to the sulfate content of the sample, is titrated with a solution of standard ferrous ion to a thermometrically determined endpoint.
- AN-H-130Determination of nitrite using sulfamic acid
This Application Note describes the determination of nitrite using thermometric endpoint titration with sulfamic acid. The nitrite content of a solution can be analyzed down to 0.2 mmol/L.
- AN-I-035イオン選択性電極を用いた食品中のナトリウム含有量の測定
ナトリウムの過剰摂取は、健康上のリスクを高める要因となります。イオン選択性電極(Na-ISE)は、食品中のナトリウムを迅速かつ正確、かつ経済的に測定する手法を提供します。
- AN-K-003ペルオキソ二硫酸アンモニウム (過硫酸アンモニウム) 中の水分
ペルオキソ二硫酸アンモニウムとカリウムの水分は、2液型のカールフィッシャー水分計を使用して測定します。副反応を防ぐために、測定は-20°Cで行います。カリウム塩は測定溶媒に不溶であるため、高周波ホモジナイザーを使用して塩粒子を粉砕してから水分測定します。
- AN-K-027石灰の水分測定
石灰の水分含有量は、カールフィッシャー水分計と気化装置を用いて150℃で測定されます。
- AN-K-030次硝酸ビスマスの水分測定
次硝酸ビスマスの水分含有量は、カールフィッシャー水分計により測定されます。
- AN-K-046炭酸カルシウムの水分測定
炭酸カルシウムの水分含有量は、容量法カールフィッシャー水分計により測定されます。
- AN-K-052酢酸ナトリウムの水分測定を自動化
この技術資料では、カールフィッシャー水分計を使用して酢酸ナトリウム三水和物の水分測定をおこなっています。 MATi 10システムを使用すると、多検体測定が完全自動化でき測定にかかる時間が削減できます。
- AN-N-007有機二ナトリウム塩中の酢酸塩およびメタンスルホン酸塩
陰イオンクロマトグラフィーおよび直接電気伝導度検出による有機塩中の酢酸塩およびメタンスルホン酸塩の定量を紹介します。
- AN-N-073アンペロメトリー検出を用いた塩化ナトリウムに含まれるヨウ化物の微量分析
純粋な塩化ナトリウムはのヨウ化物の含有量は、一般的に栄養価を高めるためにそれが添加されている食卓塩などに比べ、非常に低くなっています。ヨウ化物の微量測定は、アンペロメトリー検出を伴うイオンクロマトグラフィーを用いて容易に実行することができます。この検出モードは、とりわけ分離度と感度が高くなっています。実際の分離は Metrosep A Supp 5 - 250/4.0 カラムを用いて行われます。検出は、銀の作用電極にて行われます。LOQ は (溶液にて) およそ 1.0 μg/L、サンプルではおよそ 50 μg/kg です。より短いカラムを使うことにより、LOQ がさらに向上することがあります。
- AN-O-008Citric acid and tartaric acid in fruit salt
Determination of citric acid and tartaric acid in fruit salt using ion-exclusion chromatography with direct conductivity detection.
- AN-RA-007フェンタニル検出のためのラマン強度増強
強力な合成オピオイドであるフェンタニルは、世界中で違法に流通しています。過剰摂取は致命的となる可能性があり、昏睡、瞳孔変化、チアノーゼ、呼吸不全などの症状を引き起こします。体格や過去の使用状況などによっては、わずか2mgのフェンタニルでも致死的となる可能性があります。フェンタニルは深刻な影響を及ぼすため、深刻な公衆衛生上の危機となっており、その特定と検出は極めて重要です。電気化学表面増強ラマン分光法(EC-SERS)とスクリーン印刷電極(SPE)を組み合わせることで、フェンタニルを迅速かつ効果的かつ正確に検出することが可能になります。
- AN-RS-005ラマン分光法による無機塩類の識別
本アプリケーションノートでは、Mira M-1 などのハンドヘルドラマンスペクトロメーターが、炭酸塩、リン酸塩、硫酸塩などの無機塩類の識別および区別に適していることを示しております。本研究では、塩のラマン分光による識別における陽イオン成分および結晶水の影響評価に重点を説明します。
- AN-S-062Fluoride, chloride, bromide, and sulfate in bath salts (sea salt)
Determination of fluoride, chloride, bromide, and sulfate in bath salts (sea salt) using anion chromatography with conductivity detection after chemical suppression.
- AN-S-077Traces of iodide in common salt using amperometric detection
Determination of iodide in common salt using anion chromatography with amperometric detection at the silver electrode.
- AN-S-085Bromide in sodium chloride
Determination of bromide in NaCl crystals using anion chromatography with conductivity detection after chemical suppression.
- AN-S-101Chloride and sulfate in potassium tetraborate
Determination of chloride and sulfate in potassium tetraborate (KB4O7 * 4 H2O) using anion chromatography with conductivity detection after chemical suppression.
- AN-S-104Nitrate and sulfate in sodium phosphinate (sodium hypophosphite)
Determination of nitrate and sulfate in sodium phosphinate (sodium hypophosphite) using anion chromatography with conductivity detection after chemical suppression.
- AN-S-117Chloride, nitrate, and sulfate in sodium thiocyanate
Determination of chloride, nitrate, and sulfate in sodium thiocyanate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-148Anions in tetrasodium pyrophosphate
Determination of fluoride, chloride, nitrate, phosphate, sulfate, trimetaphosphate, and tripolyphosphate in tetrasodium pyrophosphate using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-149Anions in tripolyphosphate
Determination of chloride, nitrite, nitrate, phosphate, sulfate, trimeta-, and pyrophosphate in tripolyphosphate using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-174Iodide in table salt
Determination of iodide in a table salt using anion chromatography with conductivity detection after chemical suppression.
- AN-S-181Trace determination of chloride in quaternary ammonium hydroxide using inline cation exchange
Determination of traces of chloride in a quaternary ammonium hydroxide using anion chromatography with conductivity detection after chemical suppression and inline cation exchange to remove the matrix cations.
- AN-S-253Molybdate in 2.5% NaCl using inline matrix elimination by sample re-injection
Determination of molybdate in 2.5% NaCl using anion chromatography with conductivity detection after chemical suppression and inline matrix elimination by molybdate preconcentration after the first separation and subsequent reinjection.
- AN-SEC-004エレクトロクロミック材料の分光電気化学分析
真性導電性ポリマー (ICP) は、その優れた特性により大きな注目を集めています。 これらには、優れた化学的、熱的、酸化的安定性、調整可能な電気的特性、触媒能力、光学的および機械的特徴などが含まれます。 ICP は、センサー、帯電防止コーティング、発光ダイオード、トランジスタ、フレキシブルデバイス、および通過する光の量を調節する「スマート」ウィンドウなどのエレクトロクロミックデバイスの活性材料として、無数の用途に使用されています。 PEDOT としても知られるポリ(3,4-エチレンジオキシチオフェン) は、市場で最も有望な ICP の 1 つです。 その高い導電性、電気化学的安定性、触媒特性、ほとんどすべての一般的な溶媒に対する高い不溶性、および興味深いエレクトロクロミック特性 (例えば、ドープ状態では透明で、中性状態では着色) によるものです。 この技術資料では、分光電気化学的手法により PEDOT 膜を評価します。
- AN-T-039Free alkali in sodium hypochlorite
Determination of free alkali in sodium hypochlorite by potentiometric titration with hydrochloric acid using a combined glass electrode.
- AN-T-137Determination of sulfate in sodium sulfate according to Ph. Eur.
In accordance with the European Pharmacopoeia, sodium sulfate is determined with the PB ISE.
- AN-T-161Ph. Eur. 8.0 に則った下剤や去痰薬に含まれる硫酸塩
この技術資料では、硫酸塩の含有量をPh. Eur. 8.0に準拠して、自動滴定装置を用いて滴定液にEGTAを用いて測定しています。
- AN-T-210Assay of potassium carbonate and potassium bicarbonate
This Application Note presents a potentiometric titration method for a potassium bicarbonate and potassium carbonate assay meeting all USP General Chapter <1225> requirements.
- AN-T-215水酸化リチウムと炭酸リチウムの分析
リチウム塩(炭酸リチウムや水酸化リチウムなど)はリチウムイオン電池の電解質やカソード材料の製造など、様々なアプリケーションに使用されており、自動滴定装置を使用して製造工程の品質管理が行えます。 水酸化リチウムは、車や航空機の重要な潤滑剤であるステアリン酸リチウムの製造にも使用されています。さらに空気清浄剤としても使用されています。 炭酸リチウムは大半がアルミニウムの製造に使用されていますが、ガラスやセラミック業界でも使用されています。さらに鬱病や双極性障害などの精神疾患の治療薬にもなっています。 様々な製造工程で使用される高純度のリチウム塩の品質を把握しておくことが重要です。この資料ではOMNIS滴定装置を使用して水酸化リチウムおよび炭酸リチウムの測定例を紹介しています。
- AN-T-216硝酸リチウムの測定
硝酸リチウムは吸湿性の物質であるため、合成やその他の用途に使用する前に純度の検証が必要です。純度は全自動滴定システムを使用して簡単に測定できます。この分析は、エタノール溶液中でのリチウムとフッ化物の沈殿滴定によって行われます。滴定の利点は、ICP-MS などの他の技術のように、硝酸リチウムをエタノールに溶解した後に希釈する必要がないことです。
- AN-U-001Nickel, zinc, cobalt, iron(II), and manganese in lithium bromide using post-column reaction
Determination of nickel, zinc, iron(II), and manganese in lithium bromide using cation chromatography with UV/VIS detection (520 nm) after post-column reaction.
- AN-U-002Bromide and nitrate in 1% sodium chloride
Determination of bromide and nitrate in 1% sodium chloride solution using anion chromatography with UV/VIS detection (205 nm) after chemical suppression.
- AN-U-008Trace anions in magnesium chloride (MgCl2) using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection
Determination of traces of fluoride, bromide, nitrate, phosphate, and sulfate using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection.
- AN-U-014Bromide in calcium chloride using UV detection
Determination of bromide in calcium chloride using anion chromatography with UV/VIS detection.
- AN-U-023Nitrite, bromide, nitrate, and iodide in 10 g/L sodium chloride with UV detection
Determination of nitrite, bromide, nitrate, and iodide in 10 g/L sodium chloride using anion chromatography with UV detection.
- AN-U-032Sulfide in a raw sodium vanadate solution by UV detection
Determination of sulfide in a raw vanadate solution using anion chromatography with UV/VIS detection.
- AN-V-001Iron, cadmium, lead, and copper in cobalt acetate solution
Determination of Fe, Pb, Cd, and Cu in Co(Ac)2 solution using the MME.
- AN-V-030Zinc, cadmium, lead, nickel, and cobalt in iron(III) chloride solution (40%)
Determination of Zn, Cd, Pb, Ni, and Co in FeCl3 solution of 40%.
- AN-V-081Copper, iron, and vanadium in sodium chloride
Copper, iron, and vanadium can be determined in salt samples in the µg/kg concentration range by adsorptive stripping voltammetry (AdSV) at the HMDE. No sample preparation is necessary.
- AN-V-099Cadmium, lead, and copper in triphosphate
Cadmium, lead, and copper are determined by anodic stripping voltammetry (ASV) at the HMDE using aqueous nitric acid as supporting electrolyte.
- AN-V-100Nickel and cobalt in triphosphate
Ni and Co are determined in triphosphate by adsorptive stripping voltammetry (AdSV) in ammonia buffer at pH 9.5 with addition of dimethylglyoxime (DMG).
- AN-V-102三リン酸塩に含まれるマンガンの測定
三リン酸塩(トリホスフェート)中のマンガンは、HMDE の陽極ストリッピング ボルタンメトリー (ASV) で測定できます。 サンプルは最初に分解させ、次にアルカリ溶液中で測定します。
- AN-V-103Chromium in lime (CaCO3)
Cr(VI) is determined at the HMDE in an electrolyte containing ethylenediamine and acetate. Because Cr(III) is electrochemically inactive, all Cr has to be oxidised prior to analysis.
- AN-V-118Gold in ammonium thiosulfate solution
Gold can be determined by anodic stripping voltammetry (ASV) in the µg/l range at the Ultra Trace Graphite electrode. The solution should not contain halide ions.
- WP-046NIR分光電気化学における水性限界の克服
NIR分光法にはこれまで、このスペクトル範囲での吸水が原因での限界がありました。このように、よく知られた水分限界は、NIR分光電気化学のための新たなアプリケーションの開発を制限してきました。この文書では、このスペクトル範囲での水性の働きかけを最小化するか、あるいは除去までもできるいくつかの興味深い代替法を紹介します。
- WP-062イオンの測定における困難の克服: 標準添加と直接測定に関するヒント
イオン測定は、例えばイオンクロマトグラフィー (IC)、誘導結合プラズマ発光分光分析 (ICP-OES)、もしくは原子吸光分光法 (AAS) など、複数の異なる方法で実施することができます。これらはいずれも、分析研究所において幅広く用いられている、確立したメソッドです。しかしながら、比較的高い初期費用がかかります。 対照的に、イオン選択性電極 (ISE) を用いたイオン測定は、これらの高額な技術に対する有望な代替法です。このホワイトペーパーでは、標準添加または直接測定を適用した際に直面し得る難題と、分析者がこのようなタイプの分析でより高い信頼性を得るためにいかにその問題を克服するかについて説明されています。