2.1001.6220
OMNIS Titrator Basic KFTThe OMNIS Titrator Basic KFT offers you the complete package for volumetric Karl Fischer titration. The package contains the OMNIS Titrator with magnetic stirrer for volumetric Karl Fischer titration, the Solvent Pump for manual reagent replacement, all necessary accessories for volumetric Karl Fischer titration, and one stand-alone OMNIS Software license. Titration can be carried out only with the internal buret of the OMNIS Titrator.
2.1001.4220
OMNIS Titrator KFThe OMNIS Titrator KF offers you the complete package for volumetric Karl Fischer titration. Included in the package is the OMNIS Basic Titrator with magnetic stirrer for potentiometric end point titration, the function license for KFT with conditioning, the OMNIS Solvent Module and the complete accessories for volumetric Karl Fischer titration.Benefit from the unique user-friendliness of an automatic start of titration after sample addition and maximum safety thanks to contact-free reagent handling with the 3S-Liquid Adapter and OMNIS Solvent Module.
2.860.0010
860 KF ThermoprepThe 860 KF Thermoprep is designed for thermal sample preparation in Karl Fischer titration.Numerous substances cannot be analysed by direct Karl Fischer titration as they are not soluble, react with the Karl Fischer reagent or release their water only very slowly or not until heated to high temperatures. Using tightly sealed sample vials, the sample is inserted in the oven. The samples can be subsequently analysed by any volumetric or coulometric KF titrator.
2.901.0010
901 TitrandoThe Karl Fischer Titrando for the modern titration laboratoryIn addition to the Karl Fischer mode (KFT), the high-end titrator is also equipped with the SET mode and can thus perform titrations to a predefined endpoint."iTrode ready": As a result of the high-resolution, galvanic measuring interface – now also for the first time with additional digital measuring input for the intelligent "iTrodes" electrodes – it is additionally possible to perform pH measurements with a maximum of precision.Thanks to the four MSB connectors, up to four Dosinos can be connected to the 901 Titrando. These can be used not only for titration, but also for the automated addition of sample, standard and auxiliary solutions such as solubility promoters. Furthermore, you have all of the Liquid Handling commands at your disposal, which means that the aspiration of exhausted reagent and the addition of fresh solvent can also be automated.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required
2.890.0110
890 Titrando with Touch ControlThe 890 Titrando is a high-end titrator for volumetric Karl Fischer titrations. The instrument is equipped with a built-in buret drive, four MSB connectors, a galvanically separated measuring interface and a USB connector. The Touch Control operating unit with touch-sensitive screen for controlling the Titrando, the 803 Ti Stand and a 10 mL exchange unit are included in the scope of delivery.
2.874.0120
874 Oven Sample ProcessorThe 874 Oven Sample Processor is used for automatic thermal sample preparation in Karl Fischer titration. The oven method is particularly suitable for samples that do not release their water until higher temperatures have been reached, for sparingly soluble samples, or those that react with the KF reagent.
2.875.9050
875 KF Gas Analyzer without monitorThe 875 KF Gas Analyzer is a completely configured analysis system. The instrument contains a computer with tiamo™ full titration software installed in addition to an 851 Titrando for automatic coulometric water content determination. Predefined methods for water content determination in liquefied and permanent gases facilitate work with the 875 KF Gas Analyzer.In addition to determining water content in gases, the system can also be used for determining water content in liquid and solid samples.Complies entirely with the requirements of the standard: ASTM D7995 - 19: Standard Test Method for Total Water in Liquid Butane by Liquefied Gas Sampler and Coulometric Karl Fischer Titration
2.874.0130
874 Oven Sample Processor special vialsThe 874 Oven Sample Processor is used for automatic thermal sample preparation in Karl Fischer titration. The oven method is particularly suitable for samples that do not release their water until higher temperatures have been reached, for sparingly soluble samples, or those that react with the KF reagent.This instrument can be modified to match customer-specific sample vessels. Please contact your Metrohm representative for further information.
2.1018.0010
OMNIS Coulometer without stirrerOMNIS Coulometer without magnetic stirrer for stand-alone operation or as the heart of an OMNIS titration system. The coulometer can be enhanced with additional titration, dosing or coulometer modules.Coulometry is the ideal method for water content determination in the trace range (10 μg to 10 mg absolute water content) in liquids, solids and gases. In addition, coulometric Karl Fischer titration is an absolute method making titer determination unnecessary.
2.1018.0020
OMNIS Coulometer with stirrerOMNIS Coulometer with magnetic stirrer for stand-alone operation or as the heart of an OMNIS titration system. The coulometer can be enhanced with additional titration, dosing or coulometer modules.Coulometry is the ideal method for water content determination in the trace range (10 μg to 10 mg absolute water content) in liquids, solids and gases. In addition, coulometric Karl Fischer titration is an absolute method making titer determination unnecessary.
2.915.0110
915 KF Ti-Touch"Reduce to the max" – that is the concept behind the 915 KF Ti-Touch. The new compact titrator for Karl Fischer titration from Metrohm offers the maximum in the class of stand-alone systems for routine analysis.Burets, stirrer, dosing unit and Touch Control are integrated in a single, compact system unit. This saves a great deal of space on the laboratory table.The 915 KF Ti-Touch now also fulfills FDA Regulation 21 CFR, Part 11. This means you are always on the safe side when it comes to audits.The package includes the 915 KF Ti-Touch, an 800 Dosino, a 10 mL dosing unit and additional accessories.
MATi 10
Automated volumetric KF titrationsFully automated system for volumetric Karl Fischer water content determination in up to 24 samples. The system is controlled with OMNIS software and consists of an 814 USB Sample Processor, a 901 Titrando and extensive accessories.The samples are weighed out into the beakers, sealed to protect against humidity and placed on the rack. Before the actual titration, they are dissolved in a defined volume of KF working medium, after which the water content is titrated.This method is particularly suitable for samples that dissolve readily in the KF working medium. In addition, solubility can be improved by using suitable solubility promoters.
MATi-11
Automated volumetric KF titration including sample preparationFully automated system for volumetric Karl Fischer water content determination in up to 53 samples. This system is controlled with OMNIS software and consists of an 815 Robotic USB Sample Processor XL, a 901 Titrando, a Polytron PT 1300 D and extensive accessories.The samples are weighed out into beakers, sealed to protect against humidity and placed on the rack. Before the actual titration, a defined volume of KF reagent is added and the sample is pulverized with the help of a Polytron. The water that is released is titrated afterwards. Even samples of poor solubility, e.g., tablets, can be analyzed without difficulty with this method. The use of solubility promoters can be avoided in this way.
2.917.0010
917 Coulometer with generator electrode with diaphragmThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.Recommended measuring range: 10 µg…200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.The 917 Coulometer now also fulfills FDA Regulation 21 CFR, Part 11. This means you are always on the safe side when it comes to audits.
2.917.0110
917 Coulometer with generator electrode without diaphragmThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.Recommended measuring range: 10 µg…200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.The 917 Coulometer now also fulfills FDA Regulation 21 CFR, Part 11. This means you are always on the safe side when it comes to audits.
2.852.0150
852 Titrando with generator electrode without diaphragmCoulometer including generator electrode without diaphragm and complete volumetric titration cellCoulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute water.The 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.852.0050
852 Titrando with generator electrode with diaphragmCoulometer including generator electrode with diaphragm, 801 Magnetic Stirrer, and complete volumetric titration cell.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute waterThe 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.760.0020
Sample changer KFT 760Complete system for automatic volumetric Karl Fischer titration.
2.906.0010
906 TitrandoHigh-end titrator for potentiometric and volumetric Karl Fischer titration with one measuring interface and internal buret drive. built-in buret drive; dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT); Measurement with ion-selective electrodes (MEAS CONC); "iTrode" intelligent electrodes; Dosing functions with monitoring, liquid handling; four MSB connectors for additional stirrers or dosing device systems; USB connector; For use with OMNIS Software, tiamo software, or Touch Control; Complies with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required;
2.906.0020
906 TitrandoHigh-end titrator for potentiometric and volumetric Karl Fischer titration with 2 measuring interfaces and internal dosing drive. built-in dosing drive; dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT); Measurement with ion-selective electrodes (MEAS CONC); Dosing functions with monitoring, liquid handling; 4 MSB connectors; 2 galvanically isolated measuring interfaces; USB connector; For use with OMNIS Software, tiamo software, or Touch Control; Complies with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required;
2.907.0010
907 TitrandoHigh-end titrator for potentiometric and volumetric Karl Fischer titration with one measuring interface and Dosino dosing units. up to four dosing device systems of the 800 Dosino type; dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT); Measurement with ion-selective electrodes (MEAS CONC); "iTrode" intelligent electrodes; Dosing functions with monitoring, liquid handling; four MSB connectors for additional stirrers or dosing device systems; USB connector; For use with OMNIS Software, tiamo software, or Touch Control; Complies with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required;
2.907.0020
907 TitrandoHigh-end titrator for potentiometric and volumetric Karl Fischer titration with two measuring interfaces and Dosino dosing units. up to four dosing device systems of the 800 Dosino type; dynamic (DET), monotonic (MET) and endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), Karl Fischer titration (KFT); "iTrode" intelligent electrodes; Measurement with ion-selective electrodes (MEAS CONC); Dosing functions with monitoring, liquid handling; four MSB connectors for additional stirrers or dosing device systems; USB connector; For use with OMNIS Software, tiamo software, or Touch Control; Complies with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required;
2.803.0010
803 TI Stand with stirrer and pumpCompact titration stand with magnetic stirrer and built-in pump for solvent addition and aspiration of the titration vessel contents. Suitable for Karl Fischer titrations with Titrandos. MSB connection.Including comprehensive accessories, solvent bottle and waste bottle.
2.917.1010
917 Coulometer with generator electrode with diaphragm and 860 KF ThermoprepThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer, and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.The 917 Coulometer now also fulfills FDA Regulation 21 CFR, Part 11. This means you are always on the safe side when it comes to audits.The 860 KF Thermoprep is used for thermal sample preparation. Many substances are not suitable for direct Karl Fischer titration because they are not soluble, react with the KF reagent, or because they only release their water content very slowly or only at high temperatures. Each of the samples is introduced into the oven in tightly sealed sample vessels and their water content is determined with the 917 Coulometer.
2.917.1110
917 Coulometer with generator electrode without diaphragm and 860 KF ThermoprepThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.The 917 Coulometer now also fulfills FDA Regulation 21 CFR, Part 11. This means you are always on the safe side when it comes to audits.The 860 KF Thermoprep is used for thermal sample preparation. Many substances are not suitable for direct Karl Fischer titration because they are not soluble, react with the KF reagent or because they release their water content only very slowly or only at high temperatures. Each of the samples is introduced into the oven in tightly sealed sample vessels and their water content is determined with the 917 Coulometer.
2.756.0010
756 KF Coulometer with generator electrode with diaphragmKF coulometer with built-in printer and titration cell with generator electrode with diaphragm for water content determination down to trace levels.This coulometer has become indispensable in many laboratories thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.756.0110
756 KF Coulometer with generator electrode without diaphragmKF coulometer with built-in printer and titration cell with generator electrode without diaphragm for water content determination down to trace levels.This coulometer has become indispensable in many laboratories thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.831.0010
831 KF Coulometer with generator electrode with diaphragmInexpensive coulometer including titration cell and generator electrode with diaphragm for water content determination down to trace levels.This coulometer has become indispensable in many laboratories, thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.831.0110
831 KF Coulometer with generator electrode without diaphragmInexpensive coulometer including titration cell with generator electrode without diaphragm for water content determination down to the trace range.This coulometer has become indispensable in many laboratories, thanks to its reliability, its backlit graphical display, the multi-language dialog and the simplicity of its operation. The clear display provides information regarding the relevant titration parameters and unambiguous indication of the progress of the titration in the form of a curve showing µg water over time.Recommended measuring range: 10 µg - 200 mg absolute water
2.1027.0010
Eco KF TitratorThe new Eco KF Titrator with integrated magnetic stirrer und touch-sensitive display is ideal for routine water content determination. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco KF Titrator also offers the option of connecting balances or of sending the determination data to a PC via PC / LIMS reports.
2.1029.0010
Solvent PumpSolvent Pump is used with an Eco Titrator / Eco KF Titrator / Eco Coulometer for reliably adding solvent and aspirating off titration vessel content without contact with the reagents.Device-independent use is also possible with optional 6.2164.010 power supply unit.
2.870.0010
870 KF Titrino plusThe inexpensive 870 KF Titrino plus is a KF titrator for volumetric water content determination. With it, water contents from a few ppm to 100% can be determined reliably and precisely in solid, liquid and gaseous samples.With its user interface, which is tailored to routine users, the 870 KF Titrino plus is so simple to operate that only brief orientation periods are required. It is the ideal titrator for routine determinations, also because of its robustness.Titration vessel and electrode are included in the scope of delivery.
2.899.0010
899 Coulometer with generator electrode with diaphragmThanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode and generator electrode with diaphragm are included in the scope of delivery.Recommended measuring range: 10 µg - 200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.
2.899.0110
899 Coulometer with generator electrode without diaphragmThanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode and generator electrode without diaphragm are included in the scope of delivery.Recommended measuring range: 10 µg - 200 mg absolute waterCoulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.
2.890.0010
890 TitrandoHigh-end titrator with built-in buret drive for volumetric Karl Fischer titrations.With four MSB connections, one galvanically isolated measuring interface and USB connector.Operation with 900 Touch Control or OMNIS SoftwareWith KF titration vessel und double Pt ring electrode for KFT, without 803 Ti-Stand and exchange unit.
2.888.0010
888 TitrandoHigh-end titrator with built-in buret driveWithout accessories; Operation with 900 Touch Control or OMNIS Software; Dynamic (DET), monotonic (MET), endpoint titration (SET), and Karl Fischer titration (KFT, only with operation with OMNIS SW); Four MSB connectors; one galvanically isolated measuring interface (also for intelligent "iTrodes" electrodes); USB connector;
2.1027.0100
Eco KF Titrator assemblyThe new Eco KF Titrator with integrated magnetic stirrer and touch-sensitive display is ideal for routine water content determination. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco KF Titrator also offers the option of connecting balances or of sending the determination data to a PC via PC / LIMS reports.Complete package including Solvent Pump for rapid reagent replacement without chemical contact.
2.1028.0010
Eco Coulometer with generator electrode with diaphragmThe Eco Coulometer with integrated magnetic stirrer and touch-sensitive display is ideal for water content determination in the 10 µg to 200 mg absolute water range. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco Coulometer also offers the option of being able to connect balances or send determination data to a PC via PC / LIMS reports. Indicator electrode and generator electrode with diaphragm are included in the scope of delivery.Coulometry is the ideal method for water content determination in the trace range in liquids, solids and gases. In addition, coulometry is an absolute method making titer determination unnecessary.
2.1028.0110
Eco Coulometer with generator electrode without diaphragmThe Eco Coulometer with integrated magnetic stirrer and touch-sensitive display is ideal for water content determination in the 10 µg to 200 mg absolute water range. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco Coulometer also offers the option of being able to connect balances or send determination data to a PC via PC / LIMS reports. Indicator electrode and generator electrode without diaphragm are included in the scope of delivery.Coulometry is the ideal method for water content determination in the trace range in liquids, solids and gases. In addition, coulometry is an absolute method making titer determination unnecessary.
2.824.0020
824 Easy Sample ChangerThe economic sample changer for routine use.Easy Sample Changer Micro: sample changer for titrations with smaller sample volumes. Up to 24 samples with a maximum volume of 75 mL can be processed in a single run. With the KFT equipment the Easy Sample Changer can be converted to a Karl Fischer sample changer.
2.885.0010
885 Compact Oven Sample ChangerThe 885 Compact Oven Sample Changer is used for thermal sample preparation in Karl Fischer titration. In the oven the samples can be heated up to 250°C. The moisture contained in the sample evaporates and is transported by a dry carrier gas into the titration cell, where the analysis takes place.
2.888.0310
888 Titrando with OMNIS SWHigh-end titrator with built-in buret drive• Includes OMNIS standalone license, 801 Stirrer magnetic stirrer, 20 mL exchange unit and combined "Ecotrode plus" pH glass electrode• Dynamic (DET), monotone (MET), end point titration (SET), Karl-Fischer Titration (KFT)• Four MSB connectors• Optional second buret for titration• A galvanically isolated measuring interface (also for intelligent electrodes "iTrodes")• USB connector
2.890.0310
KF Titrando with OMNIS SWThe 890 Titrando is a high-end titrator for volumetric Karl Fischer titrations. The instrument is equipped with a built-in buret drive, four MSB connectors, a galvanically separated measuring interface, and a USB connector. The OMNIS titration software for controlling the Titrando, the 803 Ti Stand and a 10 mL exchange unit are included in the scope of delivery
2.1040.6010
IONIC Titrator KFAs powerful as a computer! With its 10-inch display and its large internal database, the IONIC Titrator provides full convenience with respect to user-friendliness and data handling. Operate it like your mobile telephone or tablet and save thousands of determinations directly to the instrument.Thanks to the installed mobile communications module, you can upload your determination data directly into Metrohm Data Service, the new cloud data storage from Metrohm – without integration in your local network. This means that the data is available at all times and everywhere.pH, voltage, and temperature measurement; Volumetric Karl Fischer titration; Titration/dosing with up to 4 Dosino Modules (250,000 dosing steps); Report output on compact or network printers; Optional titration modes and additional functional enhancements:Function license for IONIC potentiometric titrator; Compliance with statutory regulations: 21 CFR Part 11; EudraLex, Volume 4, Annex 11; Option for second titration stand with magnetic or rod stirrer; Use of up to three analog or digital electrodes; Version with one digital and one measuring input each and with one magnetic stirrer (left). Complete package for volumetric Karl Fischer titration, including Dosino Module, 10 mL dosing unit, and double Pt ring electrode. Without pump.
2.1030.1020
OMNIS Sample Robot Oven 2 x 6 mLOMNIS Sample Robot Oven with 2 oven modules 6 mL and extensive accessories for the direct transition to fully automated thermal sample preparation with subsequent water determination in accordance with Karl Fischer. The system provides space in 2 sample racks for 100 sample beakers of 6 mL each. This modular system is supplied completely installed and can thus be put into operation in a very short time.
MATi 04
Automated coulometric KF titrationsMATi 4 is a fully automated system for coulometric KF titrations with high sample throughput. Up to 160 samples in 6 mL vials can be placed on the sample rack of the Sample Processor. The sample is pipetted into an external coulometric cell and then titrated there. The system is controlled with the OMNIS software.
ZBADI20162
Titrolyzer ADI2016 KF SS316The ADI 2016 Titrolyzer performs Volumetric Karl Fischer moisture/water determinations over a wide measurement range. Online closed loop sampling eliminates atmospheric moisture contamination when samples are taken manually and transported to the laboratory. Each step in analyzing the water content remains fixed and the same resulting in high repeatability. The analyzer is suitable for low ppm to percentage ranges of water content and equipped with all the features needed for 24/7 operation.
2.831.2110
831 KF Coulometer and 860 KF ThermoprepThis titration system is comprised of an 831 Coulometer and an 860 KF Thermoprep.This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 860 KF Thermoprep. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 831 Coulometer.
2.899.2110
899 Coulometer with generator electrode without diaphragm and 860 KF ThermoprepThis titration system is comprised of an 899 Coulometer and an 860 KF Thermoprep.This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 860 KF Thermoprep. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 899 Coulometer.
2.1001.0010
OMNIS Titrator without stirrer, without function licenseInnovative, modular potentiometric OMNIS Titrator. Thanks to 3S Liquid Adapter technology, handling chemicals is safer than ever before. The titrator can be freely configured with measuring modules and cylinder units and can have a stirrer added as needed. Thanks to various software function licenses, various measuring modes and functionalities are possible. Actuation via PC or local network; Connection option for up to four additional titration or dosing modules for additional applications or auxiliary solutions; Can be supplemented with magnetic stirrer and/or rod stirrer; Various cylinder sizes available: 5, 10, 20 or 50 mL; Liquid Adapter with 3S technology: Safe handling of chemicals and automatic transfer of the reagent dataMeasuring modes and software options:; Endpoint titration: "Basic" function license; Endpoint and equivalence point titration (monotonic/dynamic): "Advanced" function license; Endpoint and equivalence point titration (monotonic/dynamic) with parallel titration: "Professional" function license; Optional licenses for additional measuring, titration, and operating modes (e.g. volumetric Karl Fischer titration, conductometric or thermometric titration, coulometry, determination of the bromine index);
2.1019.0010
OMNIS Coulometer Module without stirrerCoulometer module without magnetic stirrer for connection to an OMNIS Titrator or to an OMNIS Coulometer as enhancement to include a measuring interface.
2.1019.0110
OMNIS Coulometer Module with stirrerCoulometer module with magnetic stirrer for connection to an OMNIS Titrator or to an OMNIS Coulometer as enhancement to include a measuring interface.
2.831.2010
831 KF Coulometer and 860 KF ThermoprepThis titration system is comprised of an 831 Coulometer (with generator electrode with diaphragm) and an 860 KF Thermoprep.This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 860 KF Thermoprep. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 831 Coulometer.
2.870.2010
870 KF Titrino plus and 860 KF ThermoprepThis titration system is comprised of an 870 KF Titrino plus and an 860 KF Thermoprep. This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 860 KF Thermoprep. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 870 KF Titrino plus.
2.1030.1010
OMNIS Sample Robot Oven 1 x 6 mLOMNIS Sample Robot Oven with 1 oven module 6 mL and extensive accessories for the direct transition to fully automated thermal sample preparation with subsequent water determination in accordance with Karl Fischer. The system provides space in 2 sample racks for 100 sample beakers of 6 mL each. This modular system is supplied completely installed and can thus be put into operation in a very short time. The system can also be extended upon request to include an additional oven module, thus doubling the throughput.
2.1030.1030
OMNIS Sample Robot Oven 1 x 8 mLOMNIS Sample Robot Oven with 1 oven module 8 mL and extensive accessories for the direct transition to fully automated thermal sample preparation with subsequent water determination in accordance with Karl Fischer. The system provides space in 2 sample racks for 100 sample beakers of 8 mL each. This modular system is supplied completely installed and can thus be put into operation in a very short time. The system can also be extended upon request to include an additional oven module, thus doubling the throughput.
2.851.0010
851 Titrando with generator electrode with diaphragmCoulometer including generator electrode with diaphragm and 801 Magnetic Stirrer.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Coulometric titrations are carried out easily and quickly with the 851 Titrando.Recommended measuring range: 10 µg - 200 mg absolute waterFor use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required
2.851.0110
851 Titrando with generator electrode without diaphragmCoulometer including generator electrode without diaphragm.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Coulometric titrations are carried out easily and quickly with the 851 Titrando.Recommended measuring range: 10 µg - 200 mg absolute water.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.810.0010
810 Sample ProcessorSample Processor for the automated analysis of routine samples using 916 Ti-Touch or 915 KF Ti-Touch.Sample Processor with one workstation and one built-in membrane pump for the automatic processing of potentiometric as well as Karl Fischer titrations, in series with small to medium quantities. In addition to the built-in pump, an additional one (membrane or peristaltic) and up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.
2.899.3110
899 Coulometer with generator electrode without diaphragm and 885 Compact Oven SCThis titration system is comprised of an 899 Coulometer and an 885 Compact Oven Sample Changer. It offers automated thermal sample preparation with subsequent water content determination in the smallest of spaces.This means that samples unsuitable for direct Karl Fischer titration can be analyzed. With the aid of tightly sealed sample vials, the samples are moved into the oven of the 885 Compact Oven Sample Changer. The sample is heated up, the water it contains is vaporized and channeled into the titration cell. The water content of the sample is then determined with the 899 Coulometer.
2.917.2010
917 Coulometer with generator electrode with diaphragm and 885 Compact Oven SCThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer, and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.The 885 Compact Oven SC is used for automatic thermal sample preparation. The samples are heated in the oven to a temperature of up to 250 °C. This causes the water to vaporize and then be transported with a dry carrier gas into the 917 Coulometer titration cell in which the analysis takes place.
2.917.2110
917 Coulometer with generator electrode without diaphragm and 885 Compact Oven SCThe 917 Coulometer is a compact titrator for coulometric water determination in accordance with Karl Fischer. ''Reduced to the max'' – operating module, stirrer and pump are integrated in the 917 Coulometer for rapid reagent replacement. This saves a great deal of space on the laboratory table.The 885 Compact Oven SC is used for automatic thermal sample preparation. The samples are heated in the oven to a temperature of up to 250 °C. This causes the water to vaporize and then be transported with a dry carrier gas into the 917 Coulometer titration cell in which the analysis takes place.
2.852.0060
852 Titrando with Touch Control and generator electrode with diaphragmCoulometer including generator electrode with diaphragm, Touch Control, 801 Magnetic Stirrer, and complete volumetric titration cell.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute waterThe 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
2.852.0160
852 Titrando with Touch Control and generator electrode without diaphragmCoulometer including generator electrode without diaphragm, complete volumetric titration cell, and Touch Control.Coulometry is the ideal method for water content determination in liquids, solids, and gases when it comes to water content determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.Recommended coulometry measuring range: 10 µg - 200 mg absolute waterThe 852 Titrando controls not only coulometric, but also volumetric Karl Fischer titration.For use with OMNIS Software, tiamo software, or Touch Control unit. Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required.
A302060041C
2060 TI Ex Proof Process AnalyzerThe 2060 TI Ex Proof Process Analyzer is an intrinsically safe wet chemistry process analyzer for process monitoring in gas or dust zoned hazardous environments rated as zone 0, 1 and 2, or 20, 21, and 22. It complies with EU Directives 94/9/EC (ATEX95) and is certified for Zone 1 and Zone 2 areas. Its design combines a purge and pressurization system with intrinsically safe electronic devices. The air purging phase and permanent overpressure prevent potentially explosive atmospheres from entering the analyzer enclosure.The analyzer’s design eliminates the need for purging large analyzer shelters, allowing for direct installation at the production line within hazardous zones. It supports various kinds of techniques, including titration, Karl Fischer titration, photometry, ion-selective electrode measurements, and direct measurements.
A302060041C
2060 TI Ex Proof Process AnalyzerThe 2060 TI Ex Proof Process Analyzer is an intrinsically safe wet chemistry process analyzer for process monitoring in gas or dust zoned hazardous environments rated as zone 0, 1 and 2, or 20, 21, and 22. It complies with EU Directives 94/9/EC (ATEX95) and is certified for Zone 1 and Zone 2 areas. Its design combines a purge and pressurization system with intrinsically safe electronic devices. The air purging phase and permanent overpressure prevent potentially explosive atmospheres from entering the analyzer enclosure.The analyzer’s design eliminates the need for purging large analyzer shelters, allowing for direct installation at the production line within hazardous zones. It supports various kinds of techniques, including titration, Karl Fischer titration, photometry, ion-selective electrode measurements, and direct measurements.
A252035011C
2035 Process Analyzer - PotentiometricThe 2035 Process Analyzer for Potentiometric Titration and Ion-Selective Measurements performs analyses with dedicated electrodes and titrants. Additionally, this version of the 2035 Process Analyzer is also suitable for Ion-Selective Analysis using Metrohm high performance electrodes. This accurate standard addition technique is ideal for more difficult sample matrices.The potentiometric version of the analyzer offers the most accurate results of all measuring techniques available on the market. With far more than 1000 applications already available, titration is also one of the most used methods for analysis in almost any industry for hundreds of components varying from acid/base analysis to metal concentrations in plating baths.Titration is one of the most widespread absolute chemical methods in use today. The technique is straightforward with no need for calibration.Some titration options available for this configuration:Potentiometric titration; Colorimetric titration with Fiber Optic Technology; Moisture determination based on the Karl Fischer titration method;
ADI2045010C
ADI 2045TI Process AnalyzerThe ADI 2045TI is a wet chemical analyzer. At its core lies an industrial PC with an industry standard Communication Logic Controller. Its modular wet part gives maximum flexibility to adapt the configuration to a specific application. The burettes or pumps can be chosen for all liquid handling and selection valves implemented for multiple sample streams.Simultaneous analysis between two streams and several methods gives faster response times. The control software on top of tiamo allows the user to program different sequences of analysis and set conditions and alarms. Remote access is achieved with a standard remote desktop tool for further diagnostics.The 2045TI is offering wet chem techniques: titration, Karl Fischer titration, colorimetry, direct measurement and standard additions methods. Data from external devices such as flow, density and turbidity can be imported and processed by the analyzer to compensate for results automatically and provide added monitoring value.
2.1040.0120
IONIC Titrator with 1 magnetic stirrerAs powerful as a computer! With its 10-inch display and its large internal database, the IONIC Titrator provides full convenience with respect to user-friendliness and data handling. Operate it like your mobile telephone or tablet and save thousands of determinations directly to the instrument.Thanks to the installed mobile communications module, you can upload your determination data directly into Metrohm Data Service, the new cloud data storage from Metrohm – without integration in your local network. This means that the data is available at all times and everywhere.pH, voltage, and temperature measurement; Endpoint titration; Monotonic equivalence point titration; Dynamic equivalence point titration; Over 30 method templates included for the most common potentiometric titrations in the areas of food, nonaqueous titration, and redox and surfactant titrations; Titration/dosing with up to 4 Dosino Modules (250,000 dosing steps) ; Report output on compact or network printers; Optional titration modes and additional functional enhancements:Volumetric Karl Fischer titration; Compliance with statutory regulations: 21 CFR Part 11; EudraLex, Volume 4, Annex 11; Option for second titration stand with magnetic or rod stirrer; Use of up to three analog or digital electrodes; Basic unit for potentiometric titration, version with one digital measuring input and one magnetic stirrer (left).
2.1040.0220
IONIC Titrator with 2 magnetic stirrersAs powerful as a computer! With its 10-inch display and its large internal database, the IONIC Titrator provides full convenience with respect to user-friendliness and data handling. Operate it like your mobile telephone or tablet and save thousands of determinations directly to the instrument.Thanks to the installed mobile communications module, you can upload your determination data directly into Metrohm Data Service, the new cloud data storage from Metrohm – without integration in your local network. This means that the data is available at all times and everywhere.pH, voltage, and temperature measurement; Endpoint titration; Monotonic equivalence point titration; Dynamic equivalence point titration; Over 30 method templates included for the most common potentiometric titrations in the areas of food, nonaqueous titration, and redox and surfactant titrations; Titration/dosing with up to 4 Dosino Modules (250,000 dosing steps) ; Report output on compact or network printers; Optional titration modes and additional functional enhancements:Volumetric Karl Fischer titration; Compliance with statutory regulations: 21 CFR Part 11; EudraLex, Volume 4, Annex 11; Option for second titration stand with magnetic or rod stirrer; Use of up to three analog or digital electrodes; Basic unit for potentiometric titration, version with one digital measuring input and two magnetic stirrers.
2.1040.2010
IONIC Titrator SaltAs powerful as a computer! With its 10-inch display and its large internal database, the IONIC Titrator provides full convenience with respect to user-friendliness and data handling. Operate it like your mobile telephone or tablet and save thousands of determinations directly to the instrument.Thanks to the installed mobile communications module, you can upload your determination data directly into Metrohm Data Service, the new cloud data storage from Metrohm – without integration in your local network. This means that the data is available at all times and everywhere.pH, voltage, and temperature measurement; Endpoint titration; Monotonic equivalence point titration; Dynamic equivalence point titration; Over 30 method templates included for the most common potentiometric titrations in the areas of aqueous titration, nonaqueous titration, and redox and surfactant titrations; Titration/dosing with up to 4 Dosino Modules (250,000 dosing steps); Report output on compact or network printers; Optional titration modes and additional functional enhancements:Volumetric Karl Fischer titration; Compliance with statutory regulations: 21 CFR Part 11; EudraLex, Volume 4, Annex 11; Option for second titration stand with magnetic or rod stirrer; Use of up to three analog or digital electrodes; Version with one digital measuring input and one magnetic stirrer (left). Complete package for argentometric titration, including Dosino Module, 10 mL dosing unit, and dAg Titrode.
2.1040.3010
IONIC Titrator OilAs powerful as a computer! With its 10-inch display and its large internal database, the IONIC Titrator provides full convenience with respect to user-friendliness and data handling. Operate it like your mobile telephone or tablet and save thousands of determinations directly to the instrument.Thanks to the installed mobile communications module, you can upload your determination data directly into Metrohm Data Service, the new cloud data storage from Metrohm – without integration in your local network. This means that the data is available at all times and everywhere.pH, voltage, and temperature measurement; Endpoint titration; Monotonic equivalence point titration; Dynamic equivalence point titration; Over 30 method templates included for the most common potentiometric titrations in the areas of aqueous titration, nonaqueous titration, and redox and surfactant titrations; Titration/dosing with up to 4 Dosino Modules (250,000 dosing steps); Report output on compact or network printers; Optional titration modes and additional functional enhancements:Volumetric Karl Fischer titration; Compliance with statutory regulations: 21 CFR Part 11; EudraLex, Volume 4, Annex 11; Option for second titration stand with magnetic or rod stirrer; Use of up to three analog or digital electrodes; Version with one digital measuring input and one magnetic stirrer (left). Complete package for nonaqueous acid-base titration, including Dosino Module, 20 mL dosing unit, and dSolvotrode.
2.1040.4010
IONIC Titrator Acid/BaseAs powerful as a computer! With its 10-inch display and its large internal database, the IONIC Titrator provides full convenience with respect to user-friendliness and data handling. Operate it like your mobile telephone or tablet and save thousands of determinations directly to the instrument.Thanks to the installed mobile communications module, you can upload your determination data directly into Metrohm Data Service, the new cloud data storage from Metrohm – without integration in your local network. This means that the data is available at all times and everywhere.pH, voltage, and temperature measurement; Endpoint titration; Monotonic equivalence point titration; Dynamic equivalence point titration; Over 30 method templates included for the most common potentiometric titrations in the areas of aqueous titration, nonaqueous titration, and redox and surfactant titrations; Titration/dosing with up to 4 Dosino Modules (250,000 dosing steps); Report output on compact or network printers; Optional titration modes and additional functional enhancements:Volumetric Karl Fischer titration; Compliance with statutory regulations: 21 CFR Part 11; EudraLex, Volume 4, Annex 11; Option for second titration stand with magnetic or rod stirrer; Use of up to three analog or digital electrodes; Version with one digital measuring input and one magnetic stirrer (left). Complete package for aqueous acid-base titration, including Dosino Module, 20 mL dosing unit, and dEcotrode Plus.
2.1040.5010
IONIC Titrator RedoxAs powerful as a computer! With its 10-inch display and its large internal database, the IONIC Titrator provides full convenience with respect to user-friendliness and data handling. Operate it like your mobile telephone or tablet and save thousands of determinations directly to the instrument.Thanks to the installed mobile communications module, you can upload your determination data directly into Metrohm Data Service, the new cloud data storage from Metrohm – without integration in your local network. This means that the data is available at all times and everywhere.pH, voltage, and temperature measurement; Endpoint titration; Monotonic equivalence point titration; Dynamic equivalence point titration; Over 30 method templates included for the most common potentiometric titrations in the areas of aqueous titration, nonaqueous titration, and redox and surfactant titrations; Titration/dosing with up to 4 Dosino Modules (250,000 dosing steps); Report output on compact or network printers; Optional titration modes and additional functional enhancements:Volumetric Karl Fischer titration; Compliance with statutory regulations: 21 CFR Part 11; EudraLex, Volume 4, Annex 11; Option for second titration stand with magnetic or rod stirrer; Use of up to three analog or digital electrodes; Version with one digital measuring input and one magnetic stirrer (left). Complete package for redox titrations, including Dosino Module, 20 mL dosing unit, and dPt Titrode.
A302060011C
2060 Process AnalyzerThe2060 Process Analyzer is an online wet chemistry analyzer that is suitable for countless applications. This process analyzer offers a new modularity concept consisting of a central platform, which is called a «basic cabinet».The basic cabinet consists of two parts. The upper part contains a touch screen and an industrial PC. The lower part contains the flexible wet part where the hardware for the actual analysis is housed. If the basic wet part capacity is not sufficient enough to solve an analytical challenge, then the basic cabinet can be expanded to up to four additional wet part cabinets to ensure enough space to solve even the most challenging applications. The additional cabinets can be configured in such a way that each wet part cabinet can be combined with a reagent cabinet with integrated (non-contact) level detection to increase analyzer uptime.The 2060 process analyzer offers different wet chem techniques: titration, Karl Fischer titration, photometry, direct measurement and standard additions methods.To meet all project requirements (or to meet all your needs) sample preconditioning systems can be provided to guarantee a robust analytical solution. We can provide any sample preconditioning system, such as cooling or heating, pressure reduction and degassing, filtration, and many more.