You have been redirected to your local version of the requested page
Titrasi Karl Fischer
Titrasi Karl Fischer

Titrasi Karl Fischer

Solusi lengkap untuk penentuan kadar air volumetrik dan koulometrik dengan titrasi Karl Fischer: Titrator, aksesoris, dan dukungan secara global

Titrasi Karl Fischer

in

Solusi lengkap untuk penentuan kadar air volumetrik dan koulometrik dengan titrasi Karl Fischer: Titrator, aksesoris, dan dukungan secara global

Apapun kebutuhan Anda – Kami memiliki Karl Fischer titrator untuk Anda

Portofolio titrator Karl Fischer kami mencakup opsi ringkas lengkap untuk penentuan kadar air rutin serta sistem Karl Fischer yang sepenuhnya otomatis untuk titrasi volumetrik dan koulometri Karl Fischer untuk kadar air dari 0,001 hingga 100%. Gunakan filter untuk mempersempit pencarian Anda dan menemukan titrator Karl Fischer yang tepat untuk Anda. Apakah Anda mencari titrator potensiometri?  Menuju ke halaman potensiometri titrator

Find applications for KF Titration

Temukan aplikasi untuk KF Titration

Pengukuran yang andal dan akurat  Komponen untuk KF titrator Anda

Mengapa titrator Metrohm Karl Fischer? – Sejarah kesuksesan yang panjang

Titrasi Karl Fischer adalah metode yang disukai untuk penentuan kadar air dalam farmakope dan norma yang tak terhitung jumlahnya, misalnya. ASTM atau DIN. Metrohm telah menawarkan solusi andal untuk titrasi Karl Fischer selama lebih dari 70 tahun. Sejak saat itu, instrumen terus ditingkatkan untuk memenuhi kebutuhan pengguna.

  • Dapatkan rangkaian lengkap mulai dari solusi benchtop ringkas hingga sistem otomatis modular termasuk aksesori dan perangkat lunak untuk titrasi Karl Fischer volumetrik dan koulometri dari satu pemasok.
  • Kualitas Swiss.
  • Manfaatkan kehadiran global kami di lebih dari 80 negara untuk dukungan lokal dari pakar layanan dan aplikasi kami.
  • Pelajari lebih lanjut tentang titrasi KF di lebih dari 100 catatan aplikasi yang ditulis oleh pakar aplikasi kami:

Menuju ke Pencarian Aplikasi

Selain titrator Karl Fischer, Metrohm juga menawarkan beragam titrator potensiometri dan solusi tangguh untuk analisis proses.

Potensiometrik titrator dari Metrohm

Titrasi process analyzer dari Metrohm

Karl Fischer titrator – Pertanyaan yang sering diajukan

Karl Fischer (KF) titrators are used for measuring both free and bound water content. With the KF method, you can, for instance, determine the surface water on crystals as well as the water contained within the crystals.

  • KF titrators can be used for moisture determination (i.e., water content determination) in all sample types: liquids, solids, slurries, and gases​
  • KF titrators are applied over a wide concentration range from ppm up to 100%​
  • KF titrators are fast and highly selective​
  • KF titrators supply reproducible and correct results​

A Karl Fischer (KF) titrator determines water content in samples using a specific chemical reaction. The process is based on two redox reactions involving classical alcohol-based Karl Fischer reagents. Methanol and sulfur dioxide form an alkyl sulfurous acid, which, in the presence of water and iodine, is oxidized in a water-consuming reaction. The reaction stops when all the water is consumed, and a small excess of iodine signals the endpoint of the titration

Manual or fully automated Karl Fischer instruments are available. Metrohm offers various solutions:​

  • The OMNIS KF titrator can be extended by an OMNIS Sample Robot to perform up to four fully automated titrations at the same time with automated sample changing for non-stop titration: Go to automation options for OMNIS KF titrators​ ​
  • The KF Titrando and the KF Ti-Touch offer the option to add automated thermal sample preparation for samples that cannot be titrated directly: Go to automation options for KF Titrando or KF Ti-Touch

 

 

When selecting a KF titrator, consider:

  • Water content range: Use coulometry for trace levels (ppm) and volumetry for higher concentrations.

  • Sample type: Liquids, solids, or gases may require different accessories (e.g., oven method for solids).

  • Throughput: For high sample volumes, automation (e.g., OMNIS Sample Robot) boosts efficiency.

  • Compliance needs: Ensure the system supports GMP/GLP, 21 CFR Part 11, and pharmacopeia standards.

  • Modularity: Metrohm’s OMNIS platform grows with your lab – start small and expand as needed.

Our Karl Fischer experts are happy to assist you with your questions:

Contact us

Metrohm is present in over 80 countries to ensure local training and support.

Metrohm offers:

  • On-site installation and training

  • Application support from our global network of experts

  • Webinars, tutorials, and documentation

The table below compares volumetric KF titration (volumetry) to coulometric KF titration (coulometry).

  Volumetric KF titration  Coulometric KF titration
Moisture 0,1% to 100% 0,001% to 1%
Sample addition

solid or pasty samples can be added directly into the titration vessel (opening a volumetric titration cell for a short period of time does not falsify the results)

liquid samples are added with syringe through a septum

liquids or gases are added with syringe through a septum: to avoid ambient humidity to enter the titration cell, never open a coulometric cell

Titer determination  regularly not necessary
lodine addition/generation iodine-containing titrant is added via buret produced by a generator electrode by anodic oxidation

 

To carry out volumetric titrations, you need a KF titrator with a completely equipped titration vessel, indicator electrode, dosing unit, and suitable reagents for volumetric KF titration.

For coulometric titrations, you need a coulometer, with a completely equipped titration cell, indicator electrode, a generator electrode with or without diaphragm, and a reagent suitable for coulometric KF titrations.

Low levels of water in the range of 0.001% up to 1% are analyzed best with a Coulometer.

Depending on the water content, you need to select the appropriate generator electrode. The generator electrode without diaphragm combines easy handling with reliable results. For the determination of trace level water contents, we recommend using the generator electrode with diaphragm.​

Metrohm offers various Coulometers, from basic stand-alone versions to high-end computer-controlled coulometric systems with automation and sample preparation options:

Go to coulometric Karl Fischer titrators

Trace levels of water in solvents and oils are analyzed best with a Coulometer.

Depending on the water content and which KF reagent you use, you have to select the appropriate generator electrode. With the generator electrode without diaphragm, only one reagent is required. The generator electrode with diaphragm is recommended for the determination of very low water contents and when using KF reagents containing solubilizers (e.g., chloroform).​

Metrohm offers various Coulometers:

Go to coulometric Karl Fischer titrators

There is no general answer to this question. The optimal KF method depends on the water content of the sample and not on the sample size.

Read our blog article to learn more about this topic:

Blog: Karl Fischer titration – When to use volumetry or coulometry

Low levels of water are analyzed best with a Coulometer. The coulometric method is very sensitive. Therefore, we do not recommend opening the titration cell to add a solid sample. Atmospheric moisture would falsify the results.

The oven method is the optimal solution for solids with low water content. Learn more about the oven method in our blog and application bulletin:

Blog: Oven method for sample preparation in Karl Fischer titration

Application Bulletin: Automatic Karl Fischer water content determination with the 874 Oven Sample Processor

Watch the following video to see the OMNIS Coulometer and OMNIS Sample Robot Oven in action.

Yes, it is possible to perform volumetric and coulometric Karl Fischer Titration  with one instrument.

The 852 Titrando offers the option to perform volumetric and coulometric KF titrations.

Explore the additional benefits of the KF Titrando product family:

See KF Titrando

The OMNIS Titrator or the OMNIS Coulometer can be upgraded with an OMNIS Coulometer Module or an OMNIS Dosing Module to allow volumetric and coulometric titrations with the same titration system.

Learn more about the modularity of the OMNIS platform:

See OMNIS platform

Yes, potentiometric and Karl Fischer (volumetric and coulometric) titrations can both be run on an OMNIS titrator. OMNIS titrators offer unparalleled modularity and allow adding functionality at any time. Additional titration modes can be combined and added whenever needed.

This modularity is unique to Metrohm's OMNIS platform, allowing laboratories to adjust quickly. Learn more about the modularity of OMNIS:

See OMNIS titrators

Yes, the OMNIS Coulometer allows coulometric bromine index determinations according to ASTM D1492-08.

See OMNIS Coulometer

Apakah itu titrasi Karl Fischer?

Titrasi Karl Fischer (KF) adalah salah satu metode yang paling teruji dan tepercaya untuk mengukur kadar air bebas dan terikat. Dengan metode KF, Anda dapat, misalnya, menentukan air permukaan pada kristal serta air yang terkandung di dalam kristal. Titrasi KF:

  • dapat digunakan untuk penentuan kadar air (yaitu penentuan kadar air) di semua jenis sampel: cairan, padatan, bubur, dan gas
  • bekerja pada rentang konsentrasi yang luas dari ppm hingga 100%
  • cepat dan sangat selektif
  • memberikan hasil yang dapat direproduksi dan benar

Bagaimana cara kerja titrasi Karl Fischer?

Titrasi KF didasarkan pada dua reaksi redoks. Menggunakan pereaksi Karl Fischer berbasis alkohol klasik, komponen metanol dan sulfur dioksida membentuk asam alkil sulfur. Dengan adanya air dan yodium, asam alkil sulfat dioksidasi dalam reaksi yang memakan air. Reaksi berhenti ketika semua air telah habis dan sedikit kelebihan yodium menunjukkan titik akhir titrasi.

Titrasi Karl Fischer dapat dilakukan secara manual atau otomatis sepenuhnya. Metrohm menawarkan berbagai solusi:

  • Tirator OMNIS KF dapat diperluas dengan Robot Sampel OMNIS untuk melakukan hingga empat titrasi otomatis secara bersamaan dengan penggantian sampel otomatis untuk titrasi tanpa henti: Menuju ke halaman automation options untuk OMNIS KF titrator
  • KF Titrando dan KF Ti-Touch menawarkan opsi untuk menambahkan preparasi sampel termal otomatis untuk sampel yang tidak dapat dititrasi secara langsung: Buka opsi otomatisasi untuk  KF Titrando atau KF Ti-Touch

Volumetrik dibandingkan dengan koulometrik Karl Fischer

Ada dua jenis titrasi Karl Fischer yang berbeda: metode volumetrik (volumetri) dan metode koulometri (koulometri). Tabel di bawah ini membandingkan kedua metode tersebut.

  Titrasi Volumetrik KF Titrasi Koulometrik KF
Moisture 0.1% hingga 100%
0.001% hingga 1%
Penambahan sample

sampel padat atau pucat dapat ditambahkan langsung ke dalam bejana titrasi (membuka sel titrasi volumetrik dalam waktu singkat tidak akan memalsukan hasil)

sampel cair ditambahkan dengan jarum suntik melalui septum

cairan atau gas ditambahkan dengan jarum suntik melalui septum: untuk menghindari kelembapan lingkungan memasuki sel titrasi, jangan sekali-kali membuka sel koulometri

Penentuan Titer secara berkala tidak perlu
Penambahan/pembentukan yodium titran yang mengandung yodium ditambahkan melalui buret dihasilkan oleh elektroda generator melalui oksidasi anodik

Langkah-langkah titrasi volumetrik:

  1. Masukan solvent pada vessel titrasi
  2. Pengkondisian (conditioning)
  3. Penambahan sampel ( atau water standar untuk penentuan titer)
  4. Titrasi menggunakan reagen KF

Tahapan untuk titrasi koulometrik:

  1. Masukan solvent ke dalam vessel titrasi
  2. Pengkondisian (conditioning)
  3. Penambahan sampel
  4. Titrasi menggunakan iodine

Informasi tambahan

Application bulletin: Volumetric water content determination according to Karl Fischer

Application bulletin: Titer determination in volumetric Karl Fischer titration

Application bulletin: Coulometric water content determination according to Karl Fischer

Learn more about coulometric Karl Fischer titrators

Blog: Titer determination in Karl Fischer titration

Blog: Best practice for electrodes in Karl Fischer titration

Blog: Frequently asked questions in Karl Fischer titration

Apa saja yang diperlukan untuk melakukan titrasi Karl Fischer?

Untuk melakukan titrasi volumetrik, Anda memerlukan titrator KF dengan wadah titrasi yang lengkap, elektroda indikator, unit takaran, dan reagen yang sesuai untuk titrasi KF volumetrik.

Untuk titrasi koulometri, Anda memerlukan koulometer, dengan sel titrasi yang lengkap, elektroda indikator, elektroda generator dengan atau tanpa diafragma, dan reagen yang sesuai untuk titrasi koulometri KF.

Ingin mempelajari lebih lanjut tentang titrasi KF?

Unduh monograf

Monograf "Penentuan air dengan titrasi Karl Fischer" mencakup aspek teoritis seperti, reagen, reaksi kimia, volumetri dan koulometri, metode deteksi, dan reaksi samping. Kemudian menyajikan penentuan air dalam berbagai matriks, seperti kosmetik, produk petrokimia, plastik, dan banyak lagi.